TECHNICAL DATA
SUPPLY CIRCUIT
Terminals A1-A2
Duty-cycle 100%
CONTROL INPUT
Terminals A1-B1
DC min. 25 ms
Loadable yes
http://tele-online.com Page 1 of 8
V2ZM10 12-240V AC/DC
VEO
Art.Nr.: 125100
TIMING CIRCUIT
RANGE OF FUNCTIONS
STATUS INDICATION
Supply voltage / time lapse LED U/t (green) on supply voltage applied
OUTPUT CIRCUIT
Terminals 15-16-18
Rated voltage
250V
(IEC 60947-5-1)
DC-12 8 A / 24 V
http://tele-online.com Page 2 of 8
V2ZM10 12-240V AC/DC
VEO
Art.Nr.: 125100
ACCURACY
Voltage influence -
Frequency influence -
ENVIRONMENTAL CONDITIONS
Relative humidity 5 … 95 %
GENERAL DATA
terminals IP20
flexible without
wire end ferrule
0,5 … 4 mm² (20 AWG … 12 AWG)
Stripping length 8 mm
flexible with
plastic ferrule
0,25 … 0,75 mm² (24 AWG … 19 AWG)
flexible without
wire end ferrule
0,2 … 1,5 mm² (24 AWG … 16 AWG)
Stripping length 8 mm
http://tele-online.com Page 3 of 8
V2ZM10 12-240V AC/DC
VEO
Art.Nr.: 125100
GENERAL DATA
MTTF -
Weight 85 g
ISOLATION DATA
Pollution degree
2
(IEC 61812-1)
Overvoltage category
III
(IEC 61812-1)
STANDARDS
Approvals
http://tele-online.com Page 4 of 8
V2ZM10 12-240V AC/DC
VEO
Art.Nr.: 125100
FUNCTIONS
ON delay (E)
When the supply voltage U is applied, the set interval t begins
(green LED U/t flashes). After the interval t has expired (green U
LED U/t illuminated) the output relay R switches into on-po-
sition (yellow LED illuminated). This status remains until the LED U/t
supply voltage is interrupted. If the supply voltage is inter-
rupted before the expiry of the interval t, the interval already
R t <t
expired is erased and is restarted when the supply voltage is
next applied.
http://tele-online.com Page 5 of 8
V2ZM10 12-240V AC/DC
VEO
Art.Nr.: 125100
FUNCTIONS
ON delay with control input (Es)
The supply voltage U must be constantly applied to the device U
(green LED U/t illuminated). When the control contact S is clo-
sed, the set interval t begins (green LED U/t flashes). After the LED U/t
interval t has expired (green LED U/t illuminated) the output
relay R switches into on-position (yellow LED illuminated). This
status remains until the control contact is opened again. If the
S
control contact is opened before the interval t has expired ,
the interval already expired is erased and is restarted with the R t1 <t
next cycle.
http://tele-online.com Page 6 of 8
V2ZM10 12-240V AC/DC
VEO
Art.Nr.: 125100
CONNECTIONS
UN (+) UN (+)
(-) (-)
A1 A2 B1 A1 A2 B1
16 18 15 16 18 15
16 18 15 16 18 15
http://tele-online.com Page 7 of 8
V2ZM10 12-240V AC/DC
VEO
Art.Nr.: 125100
DIMENSIONS
67 mm
76 mm 22,5 mm
CONTACT