Dual-Channel Acoustic Dosimeter


The SV 102 dual-channel instrument presents completely new approach to occupational or earmuffs (Hearing Protection Device - HPD) using MIRE technique (Microphone-In-Real-
health and safety acoustic monitoring task. The binaural dose measurements Ear). With special adapter, it can be also calibrated with available acoustic calibrators.
and the 1/1 octave analysis are simultaneously performed. Octave analysis provides direct The SV 102 together with SV 25S are designed for individual real-world test of the earmuffs
data for the design of the ear-protectors. Together with Audio Events Recording (AER) option, noise reduction ratio.
these functionalities show the new reference standard on acoustic dose measurement field, The SV 102 can be also used as a dual-channel type 2 sound level meter and real-time
now commonly available in compact size instrument. 1/1 octave analyser. Three acoustic profiles per channel allow parallel measurements
Dosimeter is offered with one or two dedicated SV 25D ceramic microphones assembled with independently defined filters and RMS detector time constants. Advanced time-history
in 1/2” housing. It ensures the very easy calibration by direct usage of commonly available logging for each profile, together with spectra saving and audio-events recording provide
acoustic calibrators. Moreover, SV 25D smart sensor, with built-in TEDS (Transducer complete information about measured signal, which is saved in non-volatile internal
Electronic Data Sheet), offers automatic calibration function. memory up to 64 MB. Data files are easily downloaded to any PC using USB interface and
The very robust casing of the SV 25D, together with the special mounting clip and dedicated SvanPC+ software.
headband, make that microphones can be very easily attached in extremely short distance Instrument is powered from two AA standard or rechargeable batteries (separate charger
from the human ears. is required) as well as the USB interface.
SV 25S smart sensor with TEDS, is dedicated for the measurements under headphones

FEATURES

l Dual-channel Acoustic Dosimeter conforming to IEC 61252 and ANSI S1.25-1991


l Dual-channel Sound Level Meter conforming to Type 2: IEC 61672
l Dual-channel 1/1 octave analysis
l Single measurement range
l Measurement range 45 dBA RMS ÷ 141 dBA Peak
l MIRE measurement technique with SV 25S
l Individual evaluation of the HPDs attenuation in real-world
l Three parallel independent profiles
l Advanced data logger, up to 12 results per channel logged
simultaneously including spectral analysis
l Audio Events Recording
l Automatic calibration thanks to the TEDS technology
l Built-in non-volatile memory up to 64 MB
l USB 1.1 interface
l Large LCD with backlight
l Integration time programmable up to 24 h

l Power supply by two AA rechargeable or standard batteries


(operational time > 24 h)
l Easy operation
l Extremely compact, light weight (260 grams with batteries)
and robust case (volume comparable to PDA devices)

.com INSTRUMENTATION FOR SOUND & VIBRATION


MEASUREMENTS
TECHNICAL SPECIFICATIONS
DOSIMETER / SLM / ANALYSER
Standards IEC 61252; ANSI S1.25-1991; Type 2: IEC 61672:2002
Acoustic Dosimeter Mode Leq, Spl, Peak, SEL, DOSE, D_8h, LAV, SEL8, PSEL, E, E_8h, “Peaks Counter” and more
Measurement simultaneous to the 1/1 octave analysis
SLM Mode Leq, Spl, SEL, LEPd, Lden, Ltm3, Ltm5, statistics - Ln (L1- L99), LMax, LMin, LPeak
Simultaneous measurement in three profiles with independent set of filters and detectors
Weighting Filters A, C and Z
RMS Detector Digital True RMS detector with Peak detection, resolution 0.1 dB
Time constants: Slow, Fast, Impulse
Microphone SV 25D, Type 2, ceramic microphone, 1/2" hausing with built-in preamplifier & integrated cable
SV 25S, Type 2, ceramic microphone, special version of the SV 25D for measurements based on
Microphone-In-Real-Ear technique (option)
SV 25D and SV 25S have built-in TEDS functionality for the automatic calibration
Measurement Range 45 dBA RMS ÷ 141 dBA Peak
Frequency Range 20 Hz ÷ 8 kHz, sampling rate 24 kHz
Dynamic Range 100 dB
X
Data Logger Time-history logging of RMS/Max/Min/Peak results to internal memory with time step down to 1 second,
up to 24 measurement results logged simultaneously
X
Audio Recorder Time-domain signal events recorder (option)
Dual Channel Mode Dual-channel measurement mode with second microphone SV 25D or SV 25S (option)
X
1/1 Octave Dual-channel 1/1 octave real-time analysis and spectra logging,
9 filters with centre frequencies from 31.5 Hz to 8 kHz, Type 1: IEC 61260 (option)

BASIC DATA
Input 2 x LEMO 2-pins
Display LCD 128 x 64 pixels plus icons with backlighting
Memory Up to 64 MB non-volatile flash type
Interfaces USB 1.1 Client,
Extended I/O - AC output (1 V Peak) / Digital Output (Alarm trigger) / Digital Input (Input trigger)
Power Supply XX
Two AA batteries (alkaline) operation time > 20 h (3.0 V / 1.6 Ah)
XX
Two rechargeable batteries (not included) operation time > 24 h (2.4 V / 2.6 Ah)
USB interface 150 mA HUB
Environmental Conditions
Temperature from -10 oC to 50 oC
Humidity up to 90 % RH, non-condensed
Dimensions 95 x 83 x 33 mm (without microphones)
Weight 260 grams with batteries (without microphones)

X
function parallel to the acoustic dosimeter mode or meter mode
XX
in single-channel dosimeter mode and backlight off

Acoustic dose measurements SLM results in 3-profiles view 1/1 octave analysis

Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice.

DISTRIBUTOR:

01
90 ED
SVANTEK Sp. z o. o. ISO RTIFI
Pl. Inwalidów 3/62 CE
PL 01-514 WARSAW, POLAND