SVAN 958 Four Channels Sound & Vibration Analyser: Features

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SVAN 958

Four Channels Sound & Vibration Analyser


The SVAN 958 is all digital, four-channel 20-kHz-band signal analyser including
Type 1 sound level meter (meeting IEC 61672) and vibration meter (meeting
ISO 8041). It is an ideal choice for Human Vibration (according to the ISO 26311,2&5 and ISO 5349-1&2 standards) and noise measurements in the occupational
health and safety monitoring tasks. All required weighting filters, along with
necessary accessories for triaxial Whole-Body and triaxial Hand-Arm vibration
measurements are available with this instrument.
Each of four channels can work simultaneously with independently configured
input (transducer type), filters and RMS detector time-constants (e.g. simultaneous
three axis measurement of the Whole-Body vibration and noise dose).
Three profiles allow parallel measurements with independently defined filters
and RMS detector time-constants in each sound channel. Each profile/channel
provides "multidimensional" analysis of measured signal (e.g. for sound Leq,
LMax, LMin, LPeak, SPL, SEL or for vibration RMS, Peak, Peak-Peak, VDV, MTVV).
Advanced time-history logging, in non-volatile 32 MB internal memory,
provides very powerful measurement capability. USB memory stick extends
this facility almost unlimitedly. Results can be easily downloaded to any PC
using standard USB (or RS 232 or IrDA) interface and SvanPC+ software.

Using computational power of its digital signal processor the SVAN 958 instrument
can perform advanced frequency analysis simultaneously to the meter mode:
- real-time four-channel 1/1 octave or 1/3 octave analysis including statistical
calculations
- real-time four-channel FFT analysis including cross spectra
- sound intensity measurements.
Measurements of Reverberation Time, noise dose and rotation speed are also
available for SVAN 958.
The time-domain signal recording on the external USB memory stick is available
as well as an exceptional feature!
SVAN 958 with RS 232 interface (SV 55) can be offered with GPRS modem, LAN
& WLAN connection module. Together with SvanPC+_RC remote communication
software, these interfaces provide easy remote access to instrument settings
& data over internet and local area network.
Instrument is powered from four AA standard or rechargeable batteries as well as
from the external DC power source or USB interface.
Robust case and light weight design accomplish the exceptional features of this
new generation instrument.

FEATURES
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l

Four-channel, 20 kHz real-time, simultaneous sound and vibration measurements


FFT real-time analysis up to 1600 lines in 20.0 kHz band
1/1 and 1/3 octave real-time analysis
Human Vibration measurements meeting ISO 8041:2005
including VDV and MTVV
Noise measurements Type 1, IEC 61672:2002
Acoustic dose meter function
Sound Intensity measurements
Reverberation Time measurements
Time-domain signal recording
FFT cross spectra
Advanced data logger including spectral analysis
USB memory stick providing almost unlimited logging capability
Advanced trigger and alarm functions
USB 1.1 Client and USB Host interfaces
RS 232 for modems support (GPRS, Ethernet, WLAN)
Integration time programmable up to 24 h
Powered by four AA standard or rechargeable batteries
Easy in use, hand held, light weight and robust case

.com

INSTRUMENTATION FOR SOUND & VIBRATION


MEASUREMENTS

TECHNICAL SPECIFICATIONS
Standards
Meter Mode
Analyser (option)

Filters
RMS & RMQ Detectors
Accelerometer (option)
Measurement Range
Frequency Range

VIBRATION LEVEL METER & ANALYSER

ISO 8041:2005
RMS, VDV, MTVV or Max, Peak, Peak-Peak
Simultaneous measurement in up to four channels with independent set of filters and detector constants
X
1/1 octave real-time analysis, 15 filters with centre frequencies from 1 Hz to 16 kHz (Type 1, IEC 61260)
X
1/3 octave real-time analysis, 45 filters with centre frequencies from 0.8 Hz to 20 kHz (Type 1, IEC 61260)
X
FFT real-time analysis up to 1600 lines with Hanning, Kaiser-Bessel or Flat Top window
X
FFT cross spectra measurements
X
RPM rotation speed measurements parallel to the vibration measurement (1 99999)
and more
Wd, Wk, Wc, Wj, Wm, Wb, Wg (ISO 2631), Wh (ISO 5349), HP1, HP3, HP10, Vel1, Vel3, Vel10,
VelMF, Dil1, Dil3, Dil10, KB (DIN 4150)
Digital true RMS & RMQ detectors with Peak detection, resolution 0.1 dB
Time constants: from 100 ms to 10 s
SV 39A/L seat accelerometer (100 mV/g sensitivity) for Whole-Body measurements
SV 38 low cost triaxial accelerometers for Whole-Body measurements (1 V/g MEMS type)
SV 50 set for Hand-Arm measurements (Dytran 3023M2 accelerometer, 10 mV/g sensitivity)
Accelerometer dependent, SV 39A/L seat accelerometer: 0.003 ms-2 RMS 500 ms-2 Peak
0.5 Hz 20 kHz; accelerometer dependent, with Dytran 3023M2: 2 Hz 10 kHz

SOUND LEVEL METER & ANALYSER


Standards
Meter Mode
Analyser (option)

Weighting Filters
RMS Detector
Microphone (option)
Measurement Range
Frequency Range

Type 1: IEC 61672-1:2002


SPL, Leq, SEL, Lden, Ltm3, Ltm5, Statistics - Ln (L1-L99), LMax, LMin, LPeak
Simultaneous measurement in three profiles per channel (up to four channels)
with independent set of filters and detector time-constants
X
1/1 octave real-time analysis, 15 filters with centre frequencies from 1 Hz to 16 kHz (Type 1, IEC 61260)
X
1/3 octave real-time analysis, 45 filters with centre frequencies from 0.8 Hz to 20 kHz (Type 1, IEC 61260)
Reverberation Time analysis in 1/3 octave bands (RT 60)
X
FFT real-time analysis up to 1600 lines with Hanning, Kaiser-Bessel or Flat Top window
X
FFT cross spectra measurements
Sound Intensity measurements
and more
Standard: A, C, Z and G
Digital true RMS detector with Peak detection, resolution 0.1 dB
Time constants: Slow, Fast, Impulse
SV 22, Type 1, 50 mV/Pa, prepolarised 1/2" condenser microphone with SV 12L preamplifier
SV 25, Type 2, dose meter, ceramic 1/2" microphone with integrated preamplifier
Total Dynamic Range: 16 dBA RMS 140 dBA Peak
Linearity Range (IEC 61672): 26 dBA RMS 140 dBA Peak
0.5 Hz 20 kHz; microphone dependent, with SV 22 microphone: 10 Hz 20 kHz

BASIC DATA
Input
Dynamic Range
Frequency Range
X
Data Logger
Display
Memory
Interfaces
Power Supply

Environmental Conditions
Dimensions
Weight
X

IEPE type (channels 1, 2, 3 - LEMO 4-pin & channel 4 - TNC connector)


100 dB, 4 x 20 bits A/D converters
0.5 Hz 20 kHz, sampling rate 48 kHz
Time-history logging to internal memory or USB memory stick
Time-domain signal recording on USB memory stick (option)
LCD 128 x 64 pixels plus icons with backlighting
32 MB non-volatile flash type, external USB memory stick (not included)
USB 1.1 Client, USB 1.1 Host, RS 232 (option: SV 55 required), IrDA (option)
Extended I/O - AC output (1 V Peak) or Digital Input/Output (Trigger / Pulse)
XX
Four AA batteries (alkaline)
operation time > 10 h (6.0 V / 1.6 Ah)
XX
Four AA rechargeable batteries (not included)
operation time > 14 h (4.8 V / 2.6 Ah)
XX
SA 17A external battery pack (option)
operation time > 24 h
External power supply
6 V DC 24 V DC (1.5 W)
USB interface
500 mA HUB
Temperature
from -10 oC to 50 oC
Humidity
up to 90 % RH, non-condensed
140 x 82 x 42 mm
510 grams with batteries

each function parallel to the meter mode

XX

with USB 1.1 Host function not active and backlight off

Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice.

DISTRIBUTOR:

01
90 ED
ISO RTIFI
CE

SVANTEK Sp. z o. o.
ul. Strzygowska 81
04-872 WARSAW, POLAND
phone/fax (+48) 22 51 88 320, (+48) 22 51 88 312
http://www.svantek.com e-mail: [email protected]