Grundfos Inline Circulator Pumps - TP-TPD-TPE-TPED

Download as pdf or txt
Download as pdf or txt
You are on page 1of 144

GRUNDFOS DATA BOOKLET

TP, TPD, TPE, TPED

In-line circulator pumps


50 Hz
Contents

Pump data TPE Series 1000 pumps


Introduction 4 Technical data 28
TP, mains-operated pumps 4 Construction 28
TPE, speed-controlled pumps 4 Applications 28
Type key 5 Operating modes of twin-head pumps 29
Codes for shaft seal 5 Control options 29

Performance range TPE Series 2000 pumps


Performance range, 2-pole, PN 6, 10, 16 6 Technical data 30
Performance range, 4-pole, PN 6, 10, 16 7 Construction 30
Performance range, 6-pole, PN 16 8 Applications 30
Performance range, 2-pole, PN 25 9 Operating modes of twin-head pumps 31
Performance range, 4-pole, PN 25 10 Control options 31

Product range Communication


Product range, 2-pole, 6, 10, 16 11 Communication with TPE, TPED pumps 32
Product range, 4-pole, PN 6, 10, 16 13
Product range, 6-pole, PN 16 15
Product range, 2-pole, PN 25 15 Speed regulation of TPE pumps
Product range, 4-pole, PN 25 16 Affinity equations 33

Operating conditions TP, TPE pumps in parallel


Pressure conditions 17 Control of TP, TPE pumps connected in parallel 34
Ambient temperature 17 Alternation / standby function for TPED pumps 34
TP, TPE pumps connected to Control MPC 34
TPE Series 2000 pumps connected to
Pumped liquids Control MPC Series 2000 35
Pumped liquids 18
Liquid temperature 18
List of pumped liquids 19 Grundfos CUE
TP pumps connected to Grundfos CUE,
external frequency converters 36
TP Series 100 and 200 pumps Functions 36
Technical data 22
Construction 22
Materials 22 Motor data
Mechanical shaft seal 23 Motors 37
Connections 23 Motor protection 38
Features and benefits 23 Electrical data, mains-operated motors 39
Electrical data, speed-controlled motors 40

TP Series 300 pumps


Technical data 24 Installation
Construction 24 Mechanical installation 41
Materials 24 Electrical installation 46
Mechanical shaft seal 24
Connections 25
Features and benefits 25 Flanges for TP pumps
Flange dimensions 48

TP Series 400 pumps


Technical data 26 Curve charts
Construction 26 How to read the curve charts 49
Materials 26 Curve conditions 50
Mechanical shaft seal 27
Connections 27
Features and benefits 27

2
Contents

Technical data/performance
curves
TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16 52
TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16 74
TP, TPD, TPE, TPED, 6-pole, PN 16 100
TP, 2-pole, PN 25 104
TP, 4-pole, PN 25 106

Weights and shipping volume


TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16 120
TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16 121
TP, TPD, 6-pole, PN 6, 10, 16 123
TP, 2-pole, PN 25 123
TP, 4-pole, PN 25 123

Accessories
Unions and valves 125
Counter flanges 126
Base plates 129
Blanking flanges 131
Insulating kits 135
Sensors 136
Potentiometer 137
R100 137
G10-LON interface 137
EMC filter 137

Minimum inlet pressure - NPSH


TP, TPD 2-pole, PN 6, 10, 16 139
TP, TPD 4-pole, PN 6, 10, 16 140
TP, TPD 6-pole, PN 16 140
TP Series 400, 2-pole, PN 25 140
TP Series 400, 4-pole, PN 25 141

Further product documentation


WebCAPS 142
WinCAPS 143

3
Pump data TP, TPD, TPE, TPED

Introduction TPE Series 1000 pumps


The difference between the TP and the TPE Series
TP pumps are designed for applications such as
1000 pump range is the motor. The motors of TPE
• district heating systems Series 1000 pumps have built-in frequency converter.
• heating systems
Via an external signal (from a sensor or a controller),
• air-conditioning systems TPE Series 1000 pumps allow for any configuration and
• district cooling systems control method required: Constant pressure,
• water supply temperature or flow.
• industrial processes For further information, see page 28.
• industrial cooling.
TPE Series 2000 pumps
The pumps are available with either mains-operated
The main differences between the TP and the TPE
motors (TP and TPD) or electronically speed-controlled
Series 2000 pumps are the motor and the factory-fitted
motors (TPE and TPED).
differential-pressure sensor.
The pumps are all single-stage, in-line centrifugal TPE Series 2000 pumps are factory-set to proportional-
pumps with mechanical shaft seal. The pumps are of pressure control.
the close-coupled type, i.e. pump and motor are
The motors of TPE Series 2000 pumps have built-in
separate units. Consequently, the pumps are less
frequency converter for continuous adjustment of the
sensitive to impurities in the pumped liquid than similar
pressure to the flow rate.
pumps of the canned rotor type.
The TPE Series 2000 range is recognized as a preset
TP, mains-operated pumps solution for quick and safe installation.
The TP range is divided into the following four groups
For further information, see page 30.
based on their construction: TP Series 100, 200, 300
and 400. Why select a TPE pump?
A TPE pump with electronic speed control offers these
TP Series 100 with union or flange connection
obvious benefits:
Rp 1 (DN 25) to Rp 1¼ (DN 32) and motor sizes from
0.12 to 0.25 kW. • energy savings
• increased comfort
For further information, see page 22.
• control and monitoring of pump performance
TP Series 200 with flange connection • communication with the pump.
DN 32 to DN 100 and motor sizes from 0.12 to 2.2 kW.
ATEX-approved TP pumps
For further information, see page 22.
On request, Grundfos offers TP and TPD pumps with
TP Series 300 with flange connection ATEX-approval.
DN 32 to DN 200 and motor sizes from 0.25 to 132 kW. All ATEX-approved TP pumps are in accordance with
For further information, see page 24. Council directive 94/9/EC (Group II, category 3). If an
ATEX-approved dry-running protection is installed, the
TP Series 400 with flange connection pump can be upgraded to category 2G.
Grundfos offers two TP Series 400 versions:
High-efficiency motors
• 10 bar version with DN 250 flange and motor sizes TP pumps are fitted with high-efficiency motors.
from 45 to 75 kW.
• 25 bar version with DN 100 to DN 400 and motor 2- and 4-pole TP pumps with motor sizes from 1.1 to
sizes from 5.5 to 630 kW. 90 kW are fitted with high-efficiency motors (EFF1).
EFF1 is the highest efficiency class defined by CEMEP.
For further information, see page 26.

TPE, speed-controlled pumps


Based on the construction and choice of material of TP
pumps, Grundfos offers the following two series of
speed-controlled TPE pumps:
• TPE Series 1000 pumps
(without factory-fitted differential-pressure sensor)
• TPE Series 2000 pumps
(with factory-fitted differential-pressure sensor)

4
Pump data TP, TPD, TPE, TPED

Type key
Example TP E D 65 -120 /2 -S -A -F -A -AUUE
Pump range
Electronically speed-controlled pump (Series 1000, 2000)
Twin-head pump
Nominal diameter of suction and discharge ports (DN)
Maximum head [dm]
Pole number
S = TPE Series 2000 (with factory-fitted differential pressure sensor)
Code for pump version:
A = Basic version
I = PN 6 flange
X = Special version
Code for pipework connection:
F = DIN flange
O = Union
Code for materials:
A = Basic version
Z = Bronze pump housing and pump head
B = Bronze impeller
Code for shaft seal
(incl. other plastic and rubber pump parts, except the neck ring)

Codes for shaft seal


Example B B U E
Grundfos type designation
A = O-ring seal with fixed seal driver
B = Rubber bellows seal
D = O-ring seal, balanced
G = Bellows seal with reduced seal faces
R = O-ring seal with reduced seal faces
Material of rotating face
A = Carbon, antimony-impregnated
B = Carbon, resin-impregnated
Q = Silicon carbide
U = Tungsten carbide
Material of stationary seat
B = Carbon, resin-impregnated
Q = Silicon carbide
U = Tungsten carbide
Material of secondary seal
E = EPDM
P = NBR rubber
V = FKM

5
6
p H
[kPa] [m] TP(D), TPE(D)
50-900 65-720
800 80
PN 6/10/16, 2-pole, 50 Hz 65-9
50-830 30
700
50-710
600 60 80-700
65-
66
500 32-580 0
50 40- 80 10
580 50-570 65 -5 70 0-4
-55
32-460 50-440 0 80-
520
80
400 40
40 5
32-380 -47 0-430 65-4
10 65-460
0
(See page 52 for performance curves)

40-270 80-400 10
300 30 50-290 50
- 0-
39
32-320 40- 36 65-3
0 40 80-250 0
360 10
80-330 0-
36
40-30 0
40-230 0 65-
32-250 260 80-240 10
10 0-
Performance range

200 20 40-2 0 31
0

The hatched area shows the performance range of TPE pumps.


40 50- -24
32-230
240 6
5-2 0
32-200 30 80 -21
0 10
0 -20 10
15 50-190 65 0 0-
32-180
-19 2
0 10
0-
50
40-190 80-180 16
Performance range, 2-pole, PN 6, 10, 16

0
50-160
32-150 80-140
100 40-180
10
90 32-120 50-180
65-180
80 8
70 40-90 40
25-90 R - 12 50-120
60 0
6
50 5
80-120 100-120
50-60

Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 50.
32-
40 4

90
R
25-50 R 65-120
32
-6
30 3 40-50 0
40-60 65
32-50 R -6
0

20 2
1 2 3 4 5 6 8 10 15 20 30 40 50 60 80 100 150 200 300
Q [m³/h]
1 2 3 4 5 6 7 8 9 10 20 30 40 50 Q [l/s]

TM02 7550 0206


2-pole, PN 6, 10, 16
TP, TPD, TPE, TPED
p H
[kPa] [m] TP(D), TPE(D)
60 200-660
PN 6/10/16, 4-pole, 50 Hz 200-590
500 50 125-420 100-410 125-320 125-360 200-530
200-470
400 40
200-4
150-39 0 0
100-370 0
300 250-390
30 80-340 125-250 15
20 20
0-3 0 -3 0
100-250 40 20 60 -4
10
100 15 0-
80-270 -33
0 0 -28
33
0 20
0-
0 32
20 0
200 50-230 15 0-
20 80-
240 150
-
0 -2
27
0
5 0 20
65-240 12 220 0-
(See page 74 for performance curves)

50-190
5- 2 25
10 10 0
0 -2
65-170 100-1 00 150 20
70 0-
15 80-170 -20
0 22
40-160 0
15 150-260
65-150
250-310
125- 0-
80 160 16
50 65-130 -1 10 0
-16 50
0 0- 200-180
32-120 13 250-280
0
Performance range

40 -
100 10 130 50-130 12

The hatched area shows the performance range of TPE pumps.


5-1

15
90 65 3 0
80-110

0-
-1

13
10
32-100
0
50 10 0- 12
80 8 -1 1
0 11 5-
65 -
90 0 11
70 80-90 0
32-80 40-100
100-90
Performance range, 4-pole, PN 6, 10, 16

60 6 50-90
80-70
50 5

10
0-
70
40 4 32-60
40-90 40-60 50-60 65-60 80-60 100-60

30 3
32-40 100-30

20 2

Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 50.
32-30 40-30 50-30 65-30 80-30

10 1
1 2 3 4 5 6 8 10 15 20 30 40 50 60 80 100 150 200 300 400 600 1000
Q [m³/h]
1 2 3 4 5 6 7 8 910
10 20 30 40 50 60 80 100 Q [l/s]

TM02 7551 4008


4-pole, PN 6, 10, 16
TP, TPD, TPE, TPED

7
8
p H
[kPa] [m] TP(D)
200 PN 16, 6-pole, 50 Hz
20

125-170/6
15

125-140/6
(See page 100 for performance curves)

12

125-110/6
100
Performance range

Performance range, 6-pole, PN 16

90
125-90/6
150-110/6
80 8

70 150-90/6

60 6 125-70/6

50 5
125-60/6 150-70/6

Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 50.
40 4
150-60/6

30 3
20 30 40 50 60 80 100 150 200 250
Q [m³/h]
6 7 8 9 10 20 30 40 50 Q [l/s]

TM02 8768 0904


TP, TPD
6-pole, PN 16
p H
[kPa] [m] TP
2000 PN 25, 2-pole, 50 Hz
200

100-1680
150
100-1530

100-1400
(See page 104 for performance curves)

100-1180
1000 100 100-1050
Performance range

Performance range, 2-pole, PN 25

900 90
100-960
800 80
100-820
700 70

600 60 100-700

500 50
100-620

400 40

300 30
20 30 40 50 60 70 80 100 150 200 300 400
Q [m³/h]
6 7 8 9 10 20 30 40 50 60 70 80 90 Q [l/s]

TM02 6868 3006


TP
2-pole, PN 25

9
10
p H
[kPa] [m] TP
PN 25, 4-pole, 50 Hz
700 70
400
- 76
600 0
60 300-750 400
-720

150-650
200-620 25
0 -6
500 6 0 300-670
50
200
-56 400-670
150-530 0
(See page 106 for performance curves)

250
400

-60
40

0
100-420 300-590
40

250
0-

20
0
54

-5
-54
0

15
0

0
40

0-
12

250
20

43
5-4
0 -5

0
Performance range

0 0-

-49
100-380
10

45

0
Performance range, 4-pole, PN 25

0
300 30 15
0 -3
5 0
100-320

25

20
15

0-
0

12
0-
-3

37

5-
400-470

0
20

38
20

37
0
0
0
125

-42
0
- 28
0 125
-31
100-270 0

200 20 1 25
-240

15
250-270

0 -27
0
250

200
100-220

-2 8
-320

10
125

0-2
-20

60
0
15

100-190 150-240
12
5-1
50 200-260

100 10
20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000 5000
Q [m³/h]
6 7 8 9 10 20 30 40 50 60 70 80 100 200 300 400 500 600 800 Q [l/s]

TM02 6869 1304


TP
4-pole, PN 25
Product range TP, TPD, TPE, TPED

Product range, 2-pole, 6, 10, 16


Electronically
Pressure Mains-operated
Design Shaft seal Materials speed-controlled
stage motor
motor
Pump housing Impeller Voltage [V] Voltage [V]

1 x 220-230 ΔV/

3 x 220-240 ΔV/

3 x 380-415 ΔV/

1 x 220-240 V

3 x 380-480 V
660-690 YV (2
TPE Series 2000 (3

Nodular cast iron

Nodular cast iron


Pump type

380-415 YV
TPE Series 1000

EN-GJS-400-18

EN-GJS-400-15
Stainless steel
TP Series 100
TP Series 200
TP Series 300
TP Series 400

240 YV
EN-GJL-250

Bronze (1
Cast iron

Cast iron

Bronze
GQQE
BQQE
BAQE
BUBE
AUUE
RUUE

DBUE

PN 10
PN 16
PN 25
PN 6
P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW]
TP 25-50/2 R z z z z z z z z z 0.12 0.12 0.37
TP 25-90/2 R z z z z z z z z z 0.25 0.25 0.37
TP 32-50 /2 R z z z z z z z z z 0.12 0.12 0.37
TP 32-90/2 R z z z z z z z z z 0.25 0.25 0.37
TP, TPD 32-60/2 z z z z z z z z z z z 0.25 0.18 0.37
TP, TPD 32-120/2 z z z z z z z z z z z 0.25 0.37 0.37
TP, TPD 32-150/2 z z z z z z z z z z z 0.37 0.37 0.37
TP, TPD 32-180/2 z z z z z z z z z z z 0.55 0.55 0.55
TP, TPD 32-230/2 z z z z z z z z z z z 0.75 0.75 0.75 0.75
TP, TPD 32-200/2 z z z z z z z z z z 1.1 1.1 1.1 1.1
TP, TPD 32-250/2 z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 32-320/2 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 32-380/2 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 32-460/2 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 32-580/2 z z z z z z z z z z 5.5 5.5 5.5
TP 40-50/2 z z z z z z z z z z 0.12 0.12 0.37
TP, TPD 40-60/2 z z z z z z z z z z z 0.25 0.25 0.37
TP 40-90/2 z z z z z z z z z z 0.25 0.25 0.37
TP, TPD 40-120/2 z z z z z z z z z z z 0.37 0.37 0.37
TP 40-180/2 z z z z z z z z z z z 0.55 0.55 0.55
TP, TPD 40-190/2 z z z z z z z z z z 0.75 0.75 0.75 0.75
TP, TPD 40-230/2 z z z z z z z z z z 1.1 1.1 1.1 1.1
TP, TPD 40-270/2 z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 40-240/2 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 40-300/2 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 40-360/2 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 40-470/2 z z z z z z z z z z 5.5 5.5 5.5
TP, TPD 40-580/2 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 50-60/2 z z z z z z z z z z z 0.25 0.37 0.37
TP, TPD 50-120/2 z z z z z z z z z z z 0.55 0.75 0.75 0.75
TP, TPD 50-180/2 z z z z z z z z z z z 0.75 0.75 0.75 0.75
TP, TPD 50-160/2 z z z z z z z z z z 1.1 1.1 1.1 1.1
TP, TPD 50-190/2 z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 50-240/2 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 50-290/2 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 50-360/2 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 50-430/2 z z z z z z z z z z 5.5 5.5 5.5
TP, TPD 50-440/2 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 50-570/2 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 50-710/2 z z z z z z z z z z 15.0 15.0 15.0
TP, TPD 50-830/2 z z z z z z z z z z 18.5 18.5 18.5
TP, TPD 50-900/2 z z z z z z z z z z 22.0 22.0 22.0
TP, TPD 65-60/2 z z z z z z z z z z z 0.55 0.55 0.55
TP, TPD 65-120/2 z z z z z z z z z z z 1.1 1.1 1.1 1.1
TP, TPD 65-180/2 z z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 65-190/2 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 65-230/2 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 65-260/2 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 65-340/2 z z z z z z z z z z 5.5 5.5 5.5

11
Product range TP, TPD, TPE, TPED

Electronically
Pressure Mains-operated
Design Shaft seal Materials speed-controlled
stage motor
motor
Pump housing Impeller Voltage [V] Voltage [V]

1 x 220-230 ΔV/

3 x 220-240 ΔV/

3 x 380-415 ΔV/

1 x 220-240 V

3 x 380-480 V
660-690 YV (2
TPE Series 2000 (3

Nodular cast iron

Nodular cast iron


Pump type

380-415 YV
TPE Series 1000

EN-GJS-400-18

EN-GJS-400-15
Stainless steel
TP Series 100
TP Series 200
TP Series 300
TP Series 400

240 YV
EN-GJL-250

Bronze (1
Cast iron

Cast iron

Bronze
GQQE
BQQE
BAQE
BUBE
AUUE
RUUE

DBUE

PN 10
PN 16
PN 25
PN 6
P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW]
TP, TPD 65-410/2 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 65-460/2 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 65-550/2 z z z z z z z z z z 15.0 15.0 15.0
TP, TPD 65-660/2 z z z z z z z z z z 18.5 18.5 18.5
TP, TPD 65-720/2 z z z z z z z z z z 22.0 22.0 22.0
TP, TPD 65-930/2 z z z z z z z z 30.0 30.0
TP, TPD 80-120/2 z z z z z z z z z z z 1.1 1.5 1.5
TP, TPD 80-140/2 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 80-180/2 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 80-210/2 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 80-240/2 z z z z z z z z z z 5.5 5.5 5.5
TP, TPD 80-250/2 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 80-330/2 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 80-400/2 z z z z z z z z z z 15.0 15.0 15.0
TP, TPD 80-520/2 z z z z z z z z z z 18.5 18.5 18.5
TP, TPD 80-570/2 z z z z z z z z z z 22.0 22.0 22.0
TP, TPD 80-700/2 z z z z z z z z 30.0 30.0
TP, TPD 100-120/2 z z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 100-160/2 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 100-200/2 z z z z z z z z z z 5.5 5.5 5.5
TP, TPD 100-240/2 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 100-250/2 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 100-310/2 z z z z z z z z z z 15.0 15.0 15.0
TP, TPD 100-360/2 z z z z z z z z z z 18.5 18.5 18.5
TP, TPD 100-390/2 z z z z z z z z z z 22.0 22.0 22.0
TP, TPD 100-480/2 z z z z z z z z 30.0 30.0
z Standard.
1)
Bronze versions are only available as single-head pumps.
2)
2-pole motors above 11 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot.
3) 2-pole TPE Series 2000 pumps with MGE motors from and including 11 to 22 kW are not available as twin-head pumps.

12
Product range TP, TPD, TPE, TPED

Product range, 4-pole, PN 6, 10, 16


Electronically
Pressure Mains-operated
Design Shaft seal Materials speed-controlled
stage motor
motor
Pump housing Impeller Voltage [V] Voltage [V]

1 x 220-230 ΔV/

3 x 220-240 ΔV/

3 x 380-415 ΔV/

1 x 220-240 V

3 x 380-480 V
660-690 YV (2
TPE Series 2000 (3

Nodular cast iron


Nodular cast iron
Pump type

380-415 YV
TPE Series 1000

EN-GJS-400-18

EN-GJS-400-15
Stainless steel
TP Series 100
TP Series 200
TP Series 300
TP Series 400

240 YV
EN-GJL-250

Bronze (1
Cast iron

Cast iron

Bronze
GQQE
BQQE
BAQE
BUBE
AUUE
RUUE

DBUE

PN 10
PN 16
PN 25
PN 6
P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW]
TP, TPD 32-30/4 z z z z z z z z z z 0.12 0.12 0.37
TP, TPD 32-40/4 z z z z z z z z z z 0.18 0.25 0.37
TP, TPD 32-60/4 z z z z z z z z z z 0.18 0.25 0.37
TP, TPD 32-80/4 z z z z z z z z z z 0.25 0.25 0.37
TP, TPD 32-100/4 z z z z z z z z z z 0.37 0.37 0.37
TP, TPD 32-120/4 z z z z z z z z z z 0.55 0.55 0.55
TP, TPD 40-30/4 z z z z z z z z z z 0.12 0.12 0.37
TP 40-60/4 z z z z z z z z z z 0.25 0.25 0.37
TP, TPD 40-90/4 z z z z z z z z z z 0.18 0.25 0.37
TP, TPD 40-100/4 z z z z z z z z z z 0.55 0.55 0.55 0.55
TP, TPD 40-130/4 z z z z z z z z z z 0.75 0.75 0.75 0.75
TP, TPD 40-160/4 z z z z z z z z z z 1.1 1.1 1.1
TP, TPD 50-30/4 z z z z z z z z z z 0.18 0.25 0.37
TP, TPD 50-60/4 z z z z z z z z z z 0.37 0.37 0.37
TP, TPD 50-90/4 z z z z z z z z z z 0.55 0.55 0.55 0.55
TP, TPD 50-110/4 z z z z z z z z z z 0.75 0.75 0.75 0.75
TP, TPD 50-130/4 z z z z z z z z z z 1.1 1.1 1.1
TP, TPD 50-160/4 z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 50-190/4 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 50-230/4 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 65-30/4 z z z z z z z z z z 0.25 0.25 0.37
TP, TPD 65-60/4 z z z z z z z z z z 0.55 0.55 0.55 0.55
TP, TPD 65-90/4 z z z z z z z z z z 0.75 0.75 0.75 0.75
TP, TPD 65-110/4 z z z z z z z z z z 1.1 1.1 1.1
TP, TPD 65-130/4 z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 65-150/4 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 65-170/4 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 65-240/4 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 80-30/4 z z z z z z z z z z z 0.37 0.37 0.37
TP, TPD 80-60/4 z z z z z z z z z z z 0.75 0.75 0.75 0.75
TP, TPD 80-70/4 z z z z z z z z z z 1.1 1.1 1.1
TP, TPD 80-90/4 z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 80-110/4 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 80-150/4 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 80-170/4 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 80-240/4 z z z z z z z z z z 5.5 5.5 5.5
TP, TPD 80-270/4 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 80-340/4 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 100-30/4 z z z z z z z z z z z 0.55 0.55 0.55 0.55
TP, TPD 100-60/4 z z z z z z z z z z z 1.1 1.1 1.1
TP, TPD 100-70/4 z z z z z z z z z z 1.5 1.5 1.5
TP, TPD 100-90/4 z z z z z z z z z z 2.2 2.2 2.2
TP, TPD 100-110/4 z z z z z z z z z z 3.0 3.0 3.0
TP, TPD 100-130/4 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 100-170/4 z z z z z z z z z z 5.5 5.5 5.5
TP, TPD 100-200/4 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 100-250/4 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 100-330/4 z z z z z z z z z z 15.0 15.0 15.0
TP, TPD 100-370/4 z z z z z z z z z z 18.5 18.5 18.5
TP, TPD 100-410/4 z z z z z z z z 22.0 22.0

13
Product range TP, TPD, TPE, TPED

Electronically
Pressure Mains-operated
Design Shaft seal Materials speed-controlled
stage motor
motor
Pump housing Impeller Voltage [V] Voltage [V]

1 x 220-230 ΔV/

3 x 220-240 ΔV/

3 x 380-415 ΔV/

1 x 220-240 V

3 x 380-480 V
660-690 YV (2
TPE Series 2000 (3

Nodular cast iron


Nodular cast iron
Pump type

380-415 YV
TPE Series 1000

EN-GJS-400-18

EN-GJS-400-15
Stainless steel
TP Series 100
TP Series 200
TP Series 300
TP Series 400

240 YV
EN-GJL-250

Bronze (1
Cast iron

Cast iron

Bronze
GQQE
BQQE
BAQE
BUBE
AUUE
RUUE

DBUE

PN 10
PN 16
PN 25
PN 6
P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW]
TP, TPD 125-110/4 z z z z z z z z z z 4.0 4.0 4.0
TP, TPD 125-130/4 z z z z z z z z z z 5.5 5.5 5.5
TP, TPD 125-160/4 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 125-210/4 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 125-250/4 z z z z z z z z z z 15.0 15.0 15.0
TP, TPD 125-320/4 z z z z z z z z z z 18.5 18.5 18.5
TP, TPD 125-360/4 z z z z z z z z 22.0 22.0
TP, TPD 125-420/4 z z z z z z z z 30.0 30.0
TP, TPD 150-130/4 z z z z z z z z z z 7.5 7.5 7.5
TP, TPD 150-160/4 z z z z z z z z z z 11.0 11.0 11.0
TP, TPD 150-200/4 z z z z z z z z z z 15.0 15.0 15.0
TP, TPD 150-220/4 z z z z z z z z z z 18.5 18.5 18.5
TP, TPD 150-250/4 z z z z z z z z 22.0 22.0
TP 150-260/4 z z z z z z z z z 18.5 18.5 18.5
TP 150-280/4 z z z z z z z z 22.0 22.0
TP 150-340/4 z z z z z z z 30.0 30.0
TP 150-390/4 z z z z z z z 37.0
TP 200-180/4 z z z z z z z 22.0 22.0
TP 200-220/4 z z z z z z z 30.0 30.0
TP 200-250/4 z z z z z z z 37.0
TP 200-270/4 z z z z z z z 45.0
TP 200-320/4 z z z z z z z 55.0
TP 200-330/4 z z z z z z z 37.0
TP 200-360/4 z z z z z z z 45.0
TP 200-400/4 z z z z z z z 55.0
TP 200-410/4 z z z z z z z 75.0
TP 200-470/4 z z z z z z z 75.0
TP 200-530/4 z z z z z z z z 90
TP 200-590/4 z z z z z z z z 110
TP 200-660/4 z z z z z z z z 132
TP 250-280/4 z z z z z z z z 45.0
TP 250-310/4 z z z z z z z z 55.0
TP 250-390/4 z z z z z z z z 75.0
z Standard.
1)
Bronze versions are only available as single-head pumps.
2)
4-pole motors above 4 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot.
3) 4-pole TPE Series 2000 pumps with MGE motors from and including 7.5 to 18.5 kW are not available as twin-head pumps..

14
Product range TP, TPD, TPE, TPED

Product range, 6-pole, PN 16


Electronically
Pressure Mains-operated
Design Shaft seal Materials speed-controlled
stage motor
motor
Pump housing Impeller Voltage [V] Voltage [V]

1 x 220-230 ΔV/

3 x 220-240 ΔV/

3 x 380-415 ΔV/

1 x 220-240 V

3 x 380-480 V

3 x 380-415 V
Nodular cast iron
Nodular cast iron
Pump type

380-415 YV

660-690 YV
TPE Series 1000
TPE Series 2000

EN-GJS-400-18

EN-GJS-400-15
Stainless steel
TP Series 100
TP Series 200
TP Series 300
TP Series 400

240 YV
EN-GJL-250

Bronze (1
Cast iron

Cast iron

Bronze
GQQE
BQQE
BAQE
BUBE
AUUE
RUUE

DBUE

PN 10
PN 16
PN 25
PN 6
P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP, TPD 125-60/6 z z z z z z z z 1.5
TP, TPD 125-70/6 z z z z z z z z 2.2 2.2
TP, TPD 125-90/6 z z z z z z z z 3.0 3.0
TP, TPD 125-110/6 z z z z z z z z 4.0 4.0
TP, TPD 125-140/6 z z z z z z z z 5.5 5.5
TP, TPD 125-170/6 z z z z z z z z 7.5 7.5
TP, TPD 150-60/6 z z z z z z z z 2.2 2.2
TP, TPD 150-70/6 z z z z z z z z 3.0 3.0
TP, TPD 150-90/6 z z z z z z z z 4.0 4.0
TP, TPD 150-110/6 z z z z z z z z 5.5 5.5
z Standard.
1
Bronze versions are only available as single-head pumps.

Product range, 2-pole, PN 25


Electronically
Pressure Mains-operated
Design Shaft seal Materials speed-controlled
stage motor
motor
Pump housing Impeller Voltage [V] Voltage [V]
1 x 220-230 ΔV/

3 x 220-240 ΔV/

3 x 380-415 ΔV/

1 x 220-240 V

3 x 380-480 V

3 x 380-415 V
Nodular cast iron

Nodular cast iron

Pump type
380-415 YV

660-690 YV
TPE Series 1000
TPE Series 2000

EN- GJS-400-15
EN-GJS-400-18

Stainless steel
TP Series 100
TP Series 200
TP Series 300
TP Series 400

240 YV
EN-GJL-250
Cast iron

Cast iron
Bronze

Bronze
GQQE
BQQE
BAQE
BUBE
AUUE
RUUE

DBUE

PN 10
PN 16
PN 25
PN 6

P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP 100-620/2 z z z z z z 37.0
TP 100-700/2 z z z z z z 45.0
TP 100-820/2 z z z z z z 55.0
TP 100-960/2 z z z z z z 75.0
TP 100-1050/2 z z z z z z 75.0
TP 100-1180/2 z z z z z z 90.0
TP 100-1400/2 z z z z z z 110.0
TP 100-1530/2 z z z z z z 132.0
TP 100-1680/2 z z z z z z 160.0
z Standard.

15
Product range TP, TPD, TPE, TPED

Product range, 4-pole, PN 25


Electronically
Pressure Mains-operated
Design Shaft seal Materials speed-controlled
stage motor
motor
Pump housing Impeller Voltage [V] Voltage [V]

1 x 220-230 ΔV/

3 x 220-240 ΔV/

3 x 380-415 ΔV/

1 x 220-240 V

3 x 380-480 V
Nodular cast iron

Nodular cast iron


Pump type

380-415 YV

660-690 YV
TPE Series 1000
TPE Series 2000

EN- GJS-400-15
EN-GJS-400-18

Stainless steel
TP Series 100
TP Series 200
TP Series 300
TP Series 400

240 YV
EN-GJL-250
Cast iron

Cast iron
Bronze

Bronze
GQQE
BQQE
BAQE
BUBE
AUUE
RUUE

DBUE

PN 10
PN 16
PN 25
PN 6
P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW]
TP 100-190/4 z z z z z z 5.5
TP 100-220/4 z z z z z z 7.5
TP 100-260/4 z z z z z z 11.0
TP 100-270/4 z z z z z z 11.0
TP 100-320/4 z z z z z z 15.0
TP 100-380/4 z z z z z z 18.5
TP 100-420/4 z z z z z z 22.0
TP 125-150/4 z z z z z z 7.5
TP 125-200/4 z z z z z z 11.0
TP 125-240/4 z z z z z z 15.0
TP 125-280/4 z z z z z z 15.0
TP 125-310/4 z z z z z z 18.5
TP 125-370/4 z z z z z z 22.0
TP 125-430/4 z z z z z z 30.0
TP 150-240/4 z z z z z z 18.5
TP 150-270/4 z z z z z z 22.0
TP 150-320/4 z z z z z z 30.0
TP 150-350/4 z z z z z z 37.0
TP 150-430/4 z z z z z z 45.0
TP 150-530/4 z z z z z z 55.0
TP 150-650/4 z z z z z z 75.0
TP 200-260/4 z z z z z z 30.0
TP 200-280/4 z z z z z z 37.0
TP 200-380/4 z z z z z z 45.0
TP 200-420/4 z z z z z z 55.0
TP 200-450/4 z z z z z z 55.0
TP 200-510/4 z z z z z z 75.0
TP 200-560/4 z z z z z z 90.0
TP 200-620/4 z z z z z z 110.0
TP 250-270/4 z z z z z z 45.0
TP 250-320/4 z z z z z z 55.0
TP 250-370/4 z z z z z z 75.0
TP 250-490/4 z z z z z z 90.0
TP 250-540/4 z z z z z z 110.0
TP 250-600/4 z z z z z z 132.0
TP 250-660/4 z z z z z z 160.0
TP 300-590/4 z z z z z z 200.0
TP 300-670/4 z z z z z z 250.0
TP 300-750/4 z z z z z z 315.0
TP 400-470/4 z z z z z z 315.0
TP 400-510/4 z z z z z z 355.0
TP 400-540/4 z z z z z z 400.0
TP 400-670/4 z z z z z z 500.0
TP 400-720/4 z z z z z z 560.0
TP 400-760/4 z z z z z z 630.0
z Standard.

16
Operating conditions TP, TPD, TPE, TPED

Pressure conditions Ambient temperature


System and test pressures MG – EFF1-motors:
1.1-11 kW motors, 2-pole –30 to +60 °C
System pressure Test pressure 1.1-4 kW, 4-pole
Pressure
[bar] [MPa] [bar] [MPa] Siemens – EFF1-motors:
15-90 kW motors, 2-pole –30 to +55 °C
PN 6 6 0.6 10 1.0 5.5-90 kW motors, 4-pole
PN 10 10 1.0 16 1.6 MGE and other motor sizes: –30 to +40 °C
PN 16 16 1.6 24 2.4 Storage: Down to –30 °C
PN 25 25 2.5 38 3.8
If the ambient temperature exceeds above maximum
Sound pressure level values or if the motor is located more than 1000 metres
Single-phase: Max. 70 dB(A). above sea level, the motor output (P2) must be reduced
Three-phase: See table below. due to the low density and consequent low cooling
effect of the air. In such cases, it may be necessary to
Maximum sound pressure level [dB(A)] - ISO 3743 use an oversize motor with a higher rated output.
Motor
Three-phase motors
[kW]
2-pole 4-pole 6-pole
0.12 - - - P2
[%] 1
0.18 - - -
100 2
0.25 56 41 -
90
0.37 56 45 - 3
80
0.55 57 42 - 70

TM03 2479 4405


0.75 56 42 - 60
1.1 59 50 - 50
1.5 58 50 47 20 25 30 35 40 45 50 55 60 65 70 75 80
t [°C]
2.2 60 52 52
1000 2250 3500 4750 m
3.0 59 52 63
4.0 63 54 63 Fig. 1 Relationship between motor output (P2) and
5.5 63 62 63 altitude
7.5 68 62 66
11.0 70 66 -
Key
15.0 70 66 - Pos Description
18.5 70 63 - Siemens – EFF1-motors:
22.0 70 63 - 1 15-90 kW motors, 2-pole
30.0 71 65 - 5.5-90 kW motors, 4-pole
37.0 71 66 - MG – EFF1-motors:
2 1.1-11 kW motors, 2-pole
45.0 71 66 - 1.1-4 kW, 4-pole
55.0 71 67 - 3 MGE and other motor sizes
75.0 73 70 -
90.0 73 70 -
110.0 76 70 -
132.0 76 70 -
160.0 76 70 -
200.0 - 70 -
250.0 - 73 -
315.0 - 73 -
355.0 - 75 -
400.0 - 75 -
500.0 - 75 -
560.0 - 78 -
630.0 - 78 -
Note: The values apply only to MG and Siemens motors.

The audible noise from TP pumps is primarily noise


from the motor fan. The selection of TPE pumps will
reduce the noise at partial load, as the motor, and
consequently, the motor fan runs at a lower speed.
Possible flow noise from control valves is also reduced
at partial load in the case of the TPE pump.

17
Pumped liquids TP, TPD, TPE, TPED

Pumped liquids Liquid temperature


Thin, clean, non-aggressive and non-explosive liquids, Liquid temperature: –25 °C to +150 °C.
not containing solid particles or fibres that may
Please note that shaft seals operating close to their
mechanically or chemically attack the pump, please
maximum temperature will require regular
see "List of pumped liquids" on page 19.
maintenance, i.e. replacement.
Examples of liquids:
Pump type Shaft seal Temperature
• central heating system water (the water should
BUBE 0 °C to +110 °C
meet the requirements of accepted standards on
TP Series 100 BQQE 0 °C to +90 °C
water quality in heating systems)
GQQE –25 °C to +90 °C
• cooling liquids BUBE 0 °C to +140 °C
• domestic hot water TP Series 200 AUUE 0 °C to +90 °C
• industrial liquids RUUE –25 °C to +90 °C
BAQE 0 °C to +120 °C (140 °C) 1)
• softened water.
TP Series 300 BQQE 0 °C to +90 °C
If glycol or another antifreeze agent is added to the GQQE –25 °C to +90 °C (60 °C) 2)
pumped liquid, the pump must have a shaft seal of the BAQE 0 °C to +120 °C
type RUUE or GQQE. TP Series 400,
BQQE 0 °C to +90 °C
10 bar version
The pumping of liquids with densities or kinematic GQQE –25 °C to +90 °C
TP Series 400,
viscosities higher than those of water can cause DBUE 0 °C to +150 °C 3)
25 bar version
• a considerable pressure drop 1)
TP Series 300 pumps are designed for a maximum operating
temperature of 140 °C. For operation above 120 °C, an alternative
• a drop in the hydraulic performance shaft seal is to be selected. Contact Grundfos.
• a rise in the power consumption. 2) The below listed TP Series 300 pumps with GQQE shaft seals are
designed for a maximum operating temperature of 60 °C.
In these situations, equip the pump with an oversize
motor. If in doubt, contact Grundfos. TP 150-260/4 TP 200-180/4
TP 150-280/4 TP 200-220/4
If the water contains mineral oils or chemicals, or if TP 150-340/4 TP 200-250/4
other liquids than water are pumped, the O-rings should TP 150-390/4 TP 200-270/4
be chosen accordingly. TP 200-320/4
TP 200-330/4
TP 200-360/4
TP 200-400/4
TP 200-410/4
TP 200-470/4
TP 200-530/4
TP 200-590/4
TP 200-660/4
3)
At +120 to +150 °C, the maximum operating pressure ≤23 bar.

Depending on the type of cast iron used and the pump


application, the maximum liquid temperature may be
limited by local regulations and laws.

18
Pumped liquids TP, TPD, TPE, TPED

List of pumped liquids


Grundfos TP and TPD pumps are designed for
circulation systems with constant flow; TPE and TPED
pumps for systems with variable flow.
Thanks to their design, the pumps can be used in a
wider liquid temperature range than pumps of the
canned rotor type.
A number of typical liquids are listed below.
Other pump versions may be used, but we consider the Legend
ones stated in the list to be the best choices.
May contain additives or impurities that may cause shaft seal
The list is intended as a general guide only, and it A
problems.
cannot replace actual testing of the pumped liquids and The density and/or viscosity differ from those of water. Consider
B
pump materials under specific working conditions. If in this when calculating motor and pump performance.
C The liquid must be oxygen-free (anaerobic).
doubt, contact Grundfos.
D Risk of crystallisation/precipitation in the shaft seal.
Use the list with some caution, as factors such as E Insoluble in water.
concentration of the pumped liquid, liquid temperature F The shaft seal rubber parts must be replaced with FKM rubber.
or pressure may affect the chemical resistance of a G Bronze housing/impeller required.
specific pump version. Risk of formation of ice on the standby pump.
H
(The risk only applies to TP, TPE Series 200 pumps.)

Shaft seal
Additional
Pumped liquids Notes TP Series 400 TP Series 400
information TP Series 100 TP Series 200 TP Series 300
PN 10 PN 25
Water
<+90 °C BQQE AUUE BQQE
Groundwater BAQE 1) BAQE DBUE
>+90 °C BUBE BUBE
BBQE 3)
<+120 °C BUBE 4) BUBE BAQE BAQE DBUE
Boiler-feed water <+140 °C BUBE BQBE/DAQF 3) DBUE
<+150 °C DBUE
District heating water <+120 °C BUBE BUBE BAQE BAQE DBUE
<+90 °C BQQE AUUE BQQE
Condensate BAQE DBUE
>+90 °C BUBE BUBE BAQE
<+90 °C BQQE AUUE BQQE
Softened water C BAQE DBUE
>+90 °C BUBE BUBE BAQE
pH>6.5, +40 °C, BUBE BUBE
Brackish water G BQQE BQQE DBUE
1000 ppm Cl- BQQE AUUE
Coolants

BQQE AUUE BAQE2)


Ethylene glycol B, D, H <+50 °C, 50 %
GQQE RUUE BQQE GQQE DQQE3)
GQQE
BQQE AUUE BQQE
Glycerine (glycerol) B, D, H <+50 °C, 50 %
GQQE RUUE GQQE
GQQE DQQE3)

BQQE AUUE BQQE


Potassium acetate B, D, C, H <+50°C, 50%
GQQE RUUE GQQE
GQQE DQQE3)

BQQE AUUE BQQE


Potassium formate B, D, C, H <+50 °C, 50 %
GQQE RUUE GQQE
GQQE DQQE3)

BQQE AUUE BAQE2)


Propylene glycol B, D, H
GQQE RUUE BQQE GQQE DQQE3)
GQQE
BQQE AUUE BQQE
Brine-sodium chloride B, D, C, H <+5 °C, 30 %
GQQE RUUE GQQE
GQQE DQQE3)

Synthetic oils
BUBE BUBE BAQE
Silicone oil B, E BAQE DBUE
BQQE AUUE BQQE
(To be continued)

19
Pumped liquids TP, TPD, TPE, TPED

Shaft seal
Additional
Pumped liquids Notes TP Series 400 TP Series 400
information TP Series 100 TP Series 200 TP Series 300
PN 10 PN 25

Vegetable oils
BUBV 3) BUBV 3) BAQV 3)
Corn oil B, F, E BAQV 3) DBUV 3)
BQQV 3) AUUV 3) BQQV 3)
BUBV 3) BUBV 3) BAQV 3)
Olive oil B, F, E <+80 °C BAQV 3) DBUV 3)
BQQV 3) AUUV 3) BQQV 3)
BUBV 3) BUBV 3) BAQV 3)
Peanut oil B, F, E BAQV 3) DBUV 3)
BQQV 3) AUUV 3) BQQV 3)
BUBV 3) BUBV 3) BAQV 3)
Rape seed oil D, B, F, E BAQV 3) DBUV 3)
BQQV 3) AUUV 3) BQQV 3)
BUBV 3) BUBV 3) BAQV 3)
Soya bean oil B, F, E BAQV 3) DBUV 3)
BQQV 3) AUUV 3) BQQV 3)
Cleaning agents
BQQE AUUE BQQE
Soap (salts of fatty acids) A, E, (F) <+80 °C GQQE DQQE 3)
(BQQV) 3) (AUUV) 3) (BQQV) 3)
BQQE AUUE BQQE
Alkaline degreasing agent A, E, (F) <+80 °C GQQE DQQE 3)
(BQQV) 3) (AUUV) 3) (BQQV) 3)
Oxidants
BUBE BUBE
Hydrogen peroxide <+40 °C, <2 %
BQQE AUUE
BQQE BQQV 3) DQQE 3)

Salts
Ammonium bicarbonate A <+20 °C, <15 % BQQE AUUE BQQE GQQE DQQE 3)
Calcium acetate A, B <+20 °C, <30 % BQQE AUUE BQQE GQQE DQQE 3)
Potassium bicarbonate A <+20 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
Potassium carbonate A <+20 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
Potassium permanganate A <+20 °C, <10 % BQQE AUUE BQQE GQQE DQQE 3)
Potassium sulphate A <+20 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium acetate A <+20 °C, <100 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium bicarbonate A <+20 °C, <2 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium carbonate A <+20 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium nitrate A <+20 °C, <40 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium nitrite A <+20 °C, <40 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium phosphate (di) A <+100 °C, <30 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium phosphate (tri) A <+90 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium sulphate A <+20 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium sulphite A <+20 °C, < 1% BQQE AUUE BQQE GQQE DQQE 3)
Alkalis
Ammonium hydroxide <+100 °C, <30 % BQQE AUUE BQQE GQQE DQQE 3)
Calcium hydroxide A <+100 °C, <10 % BQQE AUUE BQQE GQQE DQQE 3)
Potassium hydroxide A <+20 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
Sodium hydroxide A <+40 °C, <20 % BQQE AUUE BQQE GQQE DQQE 3)
1)
BAQE must not be used for potable water. For potable water, Grundfos recommends a BBQE shaft seal.
2)
BAQE can be used in air-condition applications at temperatures above 0 °C.
3)
The shaft seal is not standard, but available on request.
4) Maximum +110 °C.

20
21
TP Series 100 and 200 pumps TP, TPD, TPE, TPED

Materials
TP Series 100

GR8262 - GR8261
5
4
3

TM03 1210 1405


2
Fig. 2 TP Series 100 and TP Series 200
1

Technical data
Flow rate: Up to 90 m3/h
Head: Up to 27 m Fig. 3 Sectional drawing of TP Series 100 (with union
Liquid temperature (TP Series 100): –25 to +110 °C connection)
Liquid temperature (TP Series 200): –25 to +140 °C Material specification of Series 100
Maximum operating pressure: Up to 16 bar
Pos. Component Material EN/DIN
Direction of rotation: Counter-clockwise
Cast iron EN-GJL-200, EN-JL 1030
1 Pump housing
bronze CuSn10 2.1093
Construction 2 Impeller Stainless steel 1.4301
Grundfos TP Series 100 and Series 200 pumps are 3 Shaft Stainless steel 1.4057
single-stage, close-coupled pumps with in-line suction 4 Coupling Cast iron EN-GJL-400 0.7040
and discharge ports of identical diameter. Cast iron EN-GJL-250, 0.6025
5 Pump head
bronze 2.1093
The pumps are equipped with a fan-cooled
Secondary
asynchronous motor. Motor and pump shafts are seals
EPDM
connected via a rigid two-part coupling. Rotating seal Tungsten carbide
face Silicon carbide
TP Series 100 pumps with union connection are
Carbon (resin-impregnated)
available as single-head (TP) pumps. Stationary seat
Silicon carbide

TP Series 200 pumps are available as single-head (TP) TP, TPE Series 200
and twin-head (TPD) pumps.
TP Series 200 pumps have PN 6 or PN 10 flanges.
The pumps are equipped with an unbalanced
mechanical shaft seal.
The pumps are of the top-pull-out design, i.e. the power
5 4
head (motor, pump head and impeller) can be removed
3
for maintenance or service while the pump housing
TM03 1211 1405

remains in the pipework.


2
The twin-head pumps are designed with two parallel 1
power heads. A non-return flap valve in the common
discharge port is opened by the flow of the pumped
liquid and prevents backflow of liquid into the idle pump Fig. 4 Sectional drawing of TP Series 200 (with flange
head. connection)
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
TP, TPD Series 100 and 200 pumps are equipped with
high-efficiency motors.
Pumps with bronze pump housing (version B) are
suitable for circulation of domestic hot water.

22
TP Series 100 and 200 pumps TP, TPD, TPE, TPED

Material specification of Series 200 Connections


TP Series 100 pumps with union connection have
Pos. Component Material EN/DIN
suction and discharge union threads to ISO 228-1.
Cast iron EN-GJL-250, EN-JL 1040
1 Pump housing
bronze CuSn10 2.1093 TP Series 200 pumps up to DN 65 are equipped with
2 Impeller Stainless steel 1.4301 combination flanges PN 6/PN 10. DN 80 or DN 100
3 Shaft Stainless steel 1.4305 pumps have either PN 6 or PN 10 flanges. All flanges
4 Coupling Cast iron EN-GJL-400 0.7040 can be connected to flanges in accordance with
Cast iron EN-GJL-250, 0.6025 EN 1092-2 and ISO 7005-2.
5 Pump head
bronze 2.1093
Secondary
seals
EPDM Features and benefits
Rotating seal TP Series 100 and Series 200 pumps have these
Tungsten carbide
face features and benefits:
Carbon (resin-impregnated)
Stationary seat
Tungsten carbide
Optimised hydraulics for high efficiency
Mechanical shaft seal - Reduced power consumption.
Three types of unbalanced mechanical shaft seal are High-efficiency motors
available as standard: - TP pumps are fitted with high-efficiency motors.
High-efficiency motors offer reduced energy
• BUBE
The BUBE shaft seal is a Grundfos rubber bellows consumption. 2-pole and 4-pole TP pumps from
seal with tungsten carbide/carbon seal faces and 1.1 kW have EFF1 motors.
secondary seals of EPDM. Top-pull-out design
• RUUE/GQQE - Easy dismantling in case of service.
The RUUE shaft seal is a Grundfos O-ring seal with In-line design
reduced tungsten carbide/tungsten carbide seal - Contrary to end-suction pumps, in-line pumps
faces and secondary seals of EPDM. allow a straight pipework and thus often reduced
The GQQE shaft seal is a Grundfos rubber bellows installation costs.
seal with reduced silicon carbide/silicon carbide
Pump housing and pump head are electrocoated to
seal faces and secondary seals of EPDM.
improve the corrosion resistance
• AUUE/BQQE
- Electrocoating includes:
The AUUE shaft seal is a Grundfos O-ring seal with
fixed seal driver, tungsten carbide/tungsten carbide 1. Alkaline cleaning.
seal faces and secondary seals of EPDM. 2. Pretreatment with zinc phosphate coating.
The BQQE shaft seal is a Grundfos rubber bellows
3. Cathodic electrocoating (epoxy).
seal with silicon carbide/silicon carbide seal faces
and secondary seals of EPDM. 4. Curing of paint film at 200-250 °C.
Information on a selection of common pumped liquids For low-temperature applications at a high
with recommended shaft seals is shown on page 19. humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion. These
Shaft seal specification pumps are available on request.
Version KU according to Stainless steel impeller and neck ring
TP Series 100
EN 12756 - Wear-free operation with high efficiency.
Unbalanced shaft seal
TP, TPD Version NU according to
Series 200 EN 12756
TPE, TPED - pumps with built-in frequency converter
Shaft diameter 12 and 16 mm - 2-pole and 4-pole TP pumps from 0.37 and
Rubber bellows EPDM upwards are available as TPE pumps with built-in
Tungsten carbide/carbon frequency converter. For further information, see
Tungsten carbide/tungsten pages 4 and 11-14.
Seal faces carbide
Silicon carbide/silicon
carbide

Special shaft seals are available for partly conditioned


water or other liquids containing abrasive or
crystallising particles. See page 19.

23
TP Series 300 pumps TP, TPD, TPE, TPED

TP Series 300 pumps with bronze impeller are suitable


for pumping brine.

Materials

4
3
2
1

TM03 1212 1405


GR8259

Fig. 5 TP Series 300

Technical data Fig. 6 Sectional drawing of TP Series 300


Flow rate: Up to 825 m3/h
Material specification
Head: Up to 93 m
Liquid temperature: –25 to +140 °C Pos. Component Material EN/DIN
Maximum operating pressure: 16 bar 1 Pump housing Cast iron EN-GJL-250 EN-JL 1040
Cast iron EN-GJL-200, EN-JL 1030
Direction of rotation: Clockwise 2 Impeller
bronze CuSn5Zn5Pb 2.1096.01
Stub shaft Stainless steel 1.4301
3
Construction 2 part stub shaft Stainless steel/steel 1.4301/1.0301
Grundfos TP, TPD Series 300 pumps are single-stage, 4
Pump head/
Cast iron EN-GJL-250 EN-JL 1040
motor stool
close-coupled pumps with in-line suction and discharge
Secondary seals EPDM
ports of identical diameter.
Metal-impregnated
Rotating seal
The pumps are equipped with a fan-cooled face
carbon
Silicon carbide
asynchronous motor. Motor and pump shafts are
Stationary seat Silicon carbide
connected via a rigid sleeve coupling.
Most TP Series 300 pumps are available as single- Mechanical shaft seal
head (TP) and twin-head (TPD) pumps. Three types of unbalanced mechanical shaft seal are
available as standard:
TP Series 300 pumps have PN 16 flanges.
• BAQE
The pumps are equipped with an unbalanced
The BAQE shaft seal is a Grundfos rubber bellows
mechanical shaft seal. seal with carbon/silicon carbide seal faces and
The pumps are of the top-pull-out design, i.e. the power secondary seals of EPDM.
head (motor, pump head and/or motor stool and • GQQE
impeller) can be removed for maintenance or service The GQQE shaft seal is a Grundfos rubber bellows
while the pump housing remains in the pipework. seal with reduced silicon carbide/silicon carbide
seal faces and secondary seals of EPDM.
The twin-head pumps are designed with two parallel
• BQQE
power heads. A non-return flap valve in the common
The BQQE shaft seal is a Grundfos rubber bellows
discharge port is opened by the flow of the pumped seal with silicon carbide/silicon carbide seal faces
liquid and prevents backflow of liquid into the idle pump and secondary seals of EPDM.
head.
Information on a selection of common pumped liquids
As radial and axial forces are absorbed by the fixed with recommended shaft seals is shown on page 19.
bearing in the motor drive-end, the pump requires no
Shaft seal specification
bearing.
The impeller is hydraulically balanced to minimize axial Unbalanced shaft seal Version NU according to EN 12756
forces. Shaft diameter 28, 38, 48 and 55 mm

TP, TPD Series 300 pumps are equipped with high- Rubber bellows EPDM

efficiency motors. Carbon/silicon carbide


Seal faces
Silicon carbide/silicon carbide

24
TP Series 300 pumps TP, TPD, TPE, TPED

Special shaft seals are available for partly conditioned


water or other liquids containing abrasive or
crystallising particles. See page 19.

Connections
TP Series 300 pumps have PN 16 flanges. All
dimensions are according to ISO 7005-2 or EN 1092-2.

Features and benefits


TP Series 300 pumps have these features and benefits:

Optimised hydraulics for high efficiency


- Reduced power consumption.
High-efficiency motors
- TP pumps are fitted with high-efficiency motors.
High-efficiency motors offer reduced energy
consumption. 2-pole and 4-pole TP pumps from
1.1 kW to 90 kW have EFF1 motors.
Top-pull-out design
- Easy dismantling in case of service.
In-line design
- Contrary to end-suction pumps, in-line pumps
allow a straight pipework and thus often reduced
installation costs.
Motor-pump shaft with sleeve coupling
- Stable and quiet operation.
- Easy dismantling in case of service.
Hydraulically and mechanically balanced impeller
- The impeller is hydraulically and mechanically
balanced to increase the life of motor bearings and
shaft seal.
Pump housing and pump head/motor stool are
electrocoated to improve the corrosion resistance
- Electrocoating includes:
1. Alkaline cleaning.
2. Pretreatment with zinc phosphate coating.
3. Cathodic electrocoating (epoxy).
4. Curing of paint film at 200-250 °C.
For low-temperature applications at a high
humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion. These
pumps are available on request.
TPE, TPED - pumps with built-in frequency converter
- 2 pole TP pumps from 0.37 to 22 kW and 4 pole TP
pumps from 0.37 to 18.5 kW are available as TPE
pumps with built-in frequency converter. For
further information, see page 4 and 11-14.

25
TP Series 400 pumps TP, TPD, TPE, TPED

Materials

5
3
4
2
1

TM02 8492 0204


Fig. 8 Sectional drawing of TP Series 400

GR7539 Material specification


Fig. 7 TP Series 400 TP Series 400, PN 10

Pos. Component Material EN/DIN


Technical data
1 Pump housing Cast iron EN-GJL-250 EN-JL1040
Flow rate: PN 10 version: Up to 950 m3/h Ductile cast iron EN-GJS-400 EN-JL1030
2 Impeller
Bronze 2.1096.01
PN 25 version: Up to 4500 m3/h
3 Pump shaft Stainless steel 1.4436
Head: PN 10 version: Up to 38 m 4 Coupling Cast iron EN-GJL-250 EN-JL1040
PN 25 version: Up to 170 m 5 Motor stool Cast iron EN-GJL-250 EN-JL1040
Liquid temperature: Secondary seals EPDM rubber
PN 10 version: –25 to +120 °C Rotating seal face
Metal-impregnated carbon
Silicon carbide
PN 25 version: 0 to +150 °C *
Stationary seat Silicon carbide
* From +120 to +150 °C, max. 23 bar
Maximum operating pressure: TP Series 400, PN 25
10 bar version: 10 bar Pos. Component Material EN/DIN
25 bar version: 25 bar Ductile cast iron
1 Pump housing EN-JS1020
Direction of rotation: Clockwise EN-GJS-400-18 (A-LT)
Impeller Ductile cast iron EN-GJS-400 EN-JS1030
2
Construction Bronze 2.1096.01
Grundfos TP Series 400 pumps are single-stage, close- 3 Pump shaft Stainless steel 1.4436
coupled pumps with in-line suction and discharge ports. 4 Coupling Cast iron EN-GJL-250 EN-JL1040
5 Motor stool Cast iron EN-GJL-250 EN-JL1040
The pumps are equipped with a fan-cooled Secondary seals EPDM rubber
asynchronous motor. Motor and pump shafts are Rotating seal face Resin-impregnated carbon
connected via a rigid flange coupling. Stationary seat Tungsten carbide

TP Series 400 pumps are available as single-head (TP)


pumps.
All TP Series 400 pumps have PN 10 or PN 25 flanges.
The largest pumps have DN 400, PN 40 discharge
flanges and a maximum operating pressure of 25 bar.
The pumps are equipped with an unbalanced
mechanical shaft seal.
The pumps are of the top-pull-out design, i.e. the power
head (motor, motor stool and impeller) can be removed
for maintenance or service while the pump housing
remains in the pipework.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
TP Series 400 pumps are equipped with high-efficiency
motors.

26
TP Series 400 pumps TP, TPD, TPE, TPED

Mechanical shaft seal Features and benefits


For 10 bar versions, the following three types of TP Series 400 pumps have the following features and
unbalanced mechanical shaft seal are available as benefits:
standard:
Optimised hydraulics for high efficiency
• BAQE
The BAQE shaft seal is a Grundfos rubber bellows - Reduced power consumption.
seal with carbon/silicon carbide seal faces and High-efficiency motors
secondary seals of EPDM. - TP pumps are fitted with high-efficiency motors.
• GQQE High-efficiency motors offer reduced energy
The GQQE shaft seal is a Grundfos rubber bellows consumption. 2-pole and 4-pole TP pumps from
seal with reduced silicon carbide/silicon carbide 1.1 to 90 kW have EFF1 motors.
seal faces and secondary seals of EPDM. Top-pull-out design
• BQQE - Easy dismantling in case of service.
The BQQE shaft seal is a Grundfos rubber bellows In-line design
seal with silicon carbide/silicon carbide seal faces
- Contrary to end-suction pumps, in-line pumps
and secondary seals of EPDM.
allow a straight pipework and thus often reduced
For 25 bar versions, the following mechanical shaft seal
installation costs.
is available as standard:
Motor-pump shaft with flange coupling
• DBUE - Stable and quiet operation.
The DBUE shaft seal is a Grundfos balanced O-ring - Easy dismantling in case of service.
seal with carbon/tungsten carbide seal faces and
Supported flange connection
secondary seals of EPDM.
- Pump housing flanges have integrated feet in
Information on a selection of common pumped liquids
order to stabilise the pump.
with recommended shaft seals is shown on page 19.
Surface treatment
Special shaft seals are available for partly conditioned TP Series 400 pumps are given the following
water or other liquids containing abrasive or surface treatment:
crystallising particles. See page 19.
Pump type Electrocoating Spray painting
Connections TP Series 400 (from DN
x x
100 to DN 300)
TP Series 400 pumps are the only TP pumps with
TP Series 400 (DN 400) 2x
suction and discharge ports of different diameters. The
suction port is one dimension larger than the discharge Electrocoating includes:
port in order to obtain a low inlet velocity. This reduces 1. Alkaline cleaning
risk of cavitation and noise.
2. Pretreatment with zinc phosphate coating
From DN 100 to DN 300 TP Series 400 pumps have 3. Cathodic electrocoating (epoxy)
flanges according to ISO 7005-2 or EN 1092-2.
4. Curing of paint film at 200-250 °C.
For low-temperature applications at a high
humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion. These
pumps are available on request.

27
TPE Series 1000 pumps TP, TPD, TPE, TPED

Applications
TPE Series 1000 pumps have integrated speed control
for automatic adaptation of performance to current
conditions.
This ensures that the energy consumption is kept at a
minimum.
TPE Series 1000 pumps can operate in any duty point
within the range between 25 % and 100 % speed.

TM03 0347 4904


HH
[m]
[m]

100 %
Fig. 9 TPE and TPED Series 1000

Technical data
Flow rate: Up to 340 m3/h

TM01 4916 1099


Head: Up to 90 m
Liquid temperature: –25 to +140 °C
25 %
Max. operating pressure: 16 bar 0
3
Motor sizes (single-phase): 0.37 to 1.1 kW 0 QQ[m
[m³/h]
h]

Motor sizes (three-phase): 0.55 to 22 kW Fig. 10 Duty range of TPE Series 1000 pumps

Construction The 100 % curve corresponds to the curve of a pump


TPE, TPED Series 1000 pumps are based on TP, with a mains-operated motor.
TPD Series 100, 200 and 300 pumps. Depending on the application, TPE Series 1000 pumps
The main difference between the TP and the offer energy-savings, increased comfort or improved
TPE Series 1000 pump range is the motor. The motor processing.
of TPE Series 1000 pumps a has built-in frequency The pumps can be fitted with sensor types meeting the
converter for continuous adjustment of the pressure to requirements mentioned in the data booklet titled
the flow rate. ‘Grundfos E-pumps’.
TPE Series 1000 pumps are suitable for applications
where the pressure, temperature, flow rate or another
parameter is to be controlled on the basis of signals
from a sensor at some point in the system.
Note: TPE Series 1000 pumps are not fitted with a
sensor from factory.
For further information on construction and materials of
TPE Series 1000 pumps, see pages 22 to 25.

28
TPE Series 1000 pumps TP, TPD, TPE, TPED

The charts below show possible control modes of TPE Control options
Series 1000 pumps in different applications. Communication with TPE, TPED Series 1000 pumps is
possible via
Control mode Application
Constant curve
• a central building management system
Single-pipe heating systems. • a remote control (Grundfos R100) or
Systems with three-way valves. • a control panel.
Heating and cooling surfaces.
The purpose of controlling a TPE, TPED Series 1000
Chiller pumps.
pump is to monitor and control the pressure,
temperature, flow rate and liquid level of the system.
Constant differential pressure For further information on control options of TPE
Systems with two-way valves. pumps, see page 32.
(Sensor is needed.)

Temperature control
Single-pipe heating systems.
Systems with three-way valves.
Cooling towers.
Chiller pumps.
Domestic hot water recirculation systems.
(Sensor is needed.)
Constant flow rate
Heating and cooling surfaces.
Cooling towers.
Flow filters.
(Sensor is needed.)

Proportional differential pressure (measured)


System with two-way valves.
(The differential pressure sensor is located
in the system.)

Operating modes of twin-head pumps


The following operating modes are available for twin-
head pumps:

Alternating operation
The two pumps run alternately for 24 operating hours.
In case of fault in the operating pump, the other pump
will start.

Standby operation
One pump is in constant operation. Every 24 operating
hours the standby pump will start and run for a short
period to prevent it from seizing up. In case of fault in
the operating pump, the standby pump will start.
The operating mode is selected by means of a selector
switch in each terminal box.
In case of sensor fault, the operating pump will switch
to maximum operation.

29
TPE Series 2000 pumps TP, TPD, TPE, TPED

Applications
TPE Series 2000 pumps have integrated speed control
for automatic adaptation of performance to current
conditions.
This ensures that the energy consumption is kept at a
minimum.
TPE Series 2000 pumps can operate in any duty point
within the range between 25 % and 100 % speed.

TM03 0348 4904


H
H
[m]
[m]

100 %
Fig. 11 TPE Series 2000

Technical data
Flow rate: Up to 340 m3/h
Head: Up to 90 m

TM01 4916 1099


Liquid temperature: –25 to +140 °C
Max. operating pressure: 16 bar 25 %
Motor sizes (single-phase): 0.37 to 1.1 kW 0
Motor sizes (three-phase): 0.55 to 22 kW 0 Q
3
Q [m³/h]
[m h]

Construction Fig. 12 Duty range of TPE Series 2000 pumps


TPE, TPED Series 2000 pumps are based on TP, TPD The 100 % curve corresponds to the curve of a pump
Series 200 and 300 pumps. with a mains-operated motor.
The main differences between the TP and the TPE Depending on the application, TPE Series 2000 pumps
Series 2000 pumps are the motor and the factory-fitted offer energy-savings, increased comfort or improved
differential pressure sensor. processing.
The motor of TPE Series 2000 pumps has built-in TPE Series 2000 pumps are suitable for applications
frequency converter for continuous adjustment of the requiring pressure control.
pressure to the flow rate.
Proportional pressure
The TPE Series 2000 range is a preset solution for
TPE Series 2000 pumps are factory-set to proportional
quick and safe installation.
pressure control. We recommend proportional pressure
For further information on construction and materials of control in systems with relatively large pressure losses,
TPE Series 2000 pumps, see pages 22 to 25. as it is the most economical control mode.
TPE Series 2000 pumps set to proportional pressure
control continuously adjust the pump head to the water
requirement of the system. The setpoint is factory-set to
50 % of the maximum pump head.
The pumps can be retrofitted with sensor types meeting
the requirements mentioned in the data booklet titled
‘Grundfos E-pumps’.

30
TPE Series 2000 pumps TP, TPD, TPE, TPED

The charts below show possible control modes of TPE Operating modes of twin-head pumps
Series 2000 pumps in different applications. The following operating modes are available for twin-
head pumps:
Control mode Application
Proportional pressure Alternating operation
Systems with two-way valves. The two pumps run alternately for 24 operating hours.
– The head against a closed valve is 50 % In case of fault in the operating pump, the other pump
of the setpoint.
will start.

Standby operation
One pump is in constant operation. Every 24 operating
hours the standby pump will start and run for a short
Constant pressure
period to prevent it from seizing up. In case of fault in
Systems with two-way valves.
the operating pump, the standby pump will start.
The operating mode is selected by means of a selector
switch in each terminal box.
In case of sensor fault, the operating pump will switch
Constant curve to maximum operation.
Single-pipe heating system.
Systems with three-way valves. Control options
Heating and cooling surfaces. Communication with TPE, TPED Series 2000 pumps is
Chiller pumps. possible via
• a central building management system
• a remote control (Grundfos R100) or
• a control panel.
The purpose of controlling TPE, TPED Series 2000
pumps is to monitor and control the pressure,
temperature, flow rate and liquid level of the system.
For further information on control options of TPE
pumps, see page 32.

31
Communication TP, TPD, TPE, TPED

Communication with TPE, TPED Remote control


The R100 remote control produced by Grundfos is
pumps available as an accessory.
Communication with TPE, TPED pumps is possible via
a central building management system, remote control The operator can communicate with the TPE, TPED
(Grundfos R100) or control panel. pump by pointing the IR-signal transmitter at the control
panel of the terminal box.
Central building management system
The operator can communicate with a TPE, TPED
pump at a distance. Communication can take place via
a central building management system allowing the
operator to monitor and change control modes and
setpoint settings.

TM03 0141 4104


Fig. 14 R100 remote control
The operator can monitor and change control modes
and settings of the TPE, TPED pump via the R100
display.
LON-bus connection
Control panel
The operator can change the setpoint settings manually
on the control panel of the TPE, TPED pump terminal
box.
G10-LON
interface

TM00 7600 0404


GENIbus connection
TM02 6592 1103

TPE pump
Fig. 15 Control panel of a TPE pump

Fig. 13 Structure of a central building management


system

32
Speed regulation of TP, TPD, TPE, TPED

TPE pumps

Affinity equations
Normally, TPE, TPED pumps are used in applications H
Q n
characterised by a variable flow. Consequently, it is not n n
-------- = ------
Q n
possible to select a pump that is constantly operating at Hn
x x
its optimum efficiency.
In order to achieve optimum operating economy, the Hx nn
H
n ⎛ n n⎞ 2
------- = ⎜ ------⎟
H ⎝ n x⎠
duty point should be close to the optimum efficiency nx x
(eta) for most operating hours.
Between the min. and max. performance curves, TPE,
Q
TPED pumps have an infinite number of performance Eta
Qx Qn
curves each representing a specific speed. It may η
----n- ≈ 1
therefore not be possible to select a duty point close to ηx
the max. curve.

nx nn
H
H
[m]
[m]

Max. curve
Q
P Qx Qn
Pn ⎛ n n⎞ 3
------- = ⎜ ------⎟
nn Px ⎝ n x⎠
Pn

Min. curve nx
Px

TM00 8720 3496


TM01 4916 4803

Q
0
0 Q
Q [m³/h]
[m3h]
Fig. 17 Affinity equations
Fig. 16 Min. and max. performance curves
Legend
In situations where it is not possible to select a duty
point close to the max. curve, use the affinity equations Hn Rated head in metres
below. The head (H), the flow rate (Q) and the input Hx Current head in metres
power (P) are the appropriate variables you need for Qn Rated flow rate in m3/h
calculating the motor speed (n). Qx Current flow rate in m3/h
Note: The approximated formulas apply on condition nn Rated motor speed in min -1
that the system characteristic remains unchanged for nx Current motor speed in min-1
nn and nx, and that it is based on the formula H = k x Q2 ηn Rated efficiency in %
where k is a constant. ηx Current efficiency in %
The power equation implies that the pump efficiency is WinCAPS and WebCAPS
unchanged at the two speeds. In practice this is not WinCAPS and WebCAPS are selection programs
quite correct. offered by Grundfos.
Finally, it is worth noting that the efficiency of the The two programs make it possible to calculate the
frequency converter and the motor must be taken into specific duty point and energy consumption of a TPE
account if a precise calculation of the power saving pump.
resulting from a reduction of the pump speed is wanted.
When you enter the dimensions of the pump, WinCAPS
and WebCAPS can calculate the exact duty point and
energy consumption. For further information, see
page 142.

33
TP, TPE pumps in parallel TP, TPD, TPE, TPED

Control of TP, TPE pumps connected TP, TPE pumps connected to Control MPC
TP, TPE-pumps can be connected directly to Grundfos
in parallel Control MPC.
In some applications parallel pump operation is
required for one or more of the following reasons: Control MPC incorporates among others a CU 351
controller that can control up to 6 pumps.
• One pump cannot achieve the required performance
(flow). By means of an external sensor Control MPC can
ensure optimum adaptation of the performance to the
• Standby capacity is required to ensure reliability of
supply. demand by closed-loop control of:

• Overall efficiency needs to be improved in case of • proportional differential pressure


big variations in the flow demand. • constant differential pressure.
The table below lists the different possibilities of • differential pressure (remote)
controlling TP, TPE-pumps connected in parallel. • flow
TPE Series • temperature.
Parallel operation control possibilities TP, TPE
2000
CU 351 incorporates features such as:
Built-in alternating/standby function
Start-up wizard
z 1) z1)
Correct installation and commissioning is a prerequisite
for attaining optimum performance of the system and
trouble-free operation year in and year out.

Control MPC During commissioning of the system a start-up wizard


is shown on the display of the CU 351. The wizard will
guide the operator through the various steps via a
series of dialogue boxes to ensure that all settings are
z
done in the correct sequence.

Application optimized software


CU 351 incorporates application optimized software
Control MPC Series 2000 which helps you set up your system to the application
in question.
Furthermore, navigating through the menus of the
z controller is done in a user friendly way - you do not
need any training to be able to set and monitor the
system.

Ethernet connection
z Available
CU 351 incorporates an Ethernet connection which
1) Aplies only to TPED pumps
makes it possible to get full and unlimited access to the
Alternation / standby function for TPED setting and monitoring of the system via a remote PC.
pumps Service port (GENI TTL)
All TPED pumps have built-in alternation/standby
The service port of the CU 351 enables easy access to
function. The pumps are supplied with a special cable
updating software and data logging in service
for the communication between the two power heads.
situations.
The function is activated from factory and "alternating"
mode is selected as default, see page 29 and page 31. External communication
Control MPC enables communication with other
fieldbus protocols. In order to communicate with other
TM03 0413 5004

fieldbus protocols a GENIbus module and a gateway is


needed.
Control MPC can communicate with PROFIbus,
Interbus-S, radio/modem/PLC via G100 gateway and
Fig. 18 TPED Series 2000 LON bus via G10 LON gateway.

34
TP, TPE pumps in parallel TP, TPD, TPE, TPED

TPE Series 2000 pumps connected to


Control MPC Series 2000
TPE Series 2000 pumps are connected directly to
Grundfos Control MPC Series 2000 via GENIbus.
Control MPC Series 2000 incorporates among others a
CU 351 controller that can control up to 6 pumps.
All pumps must be of the same pump type and size.
Control MPC Series 2000 is used for controlling
circulator pumps in heating and air-conditioning
applications.
Control MPC Series 2000 ensures optimal adaptation
of the performance to the demand by closed-loop
control of:
• proportional differential pressure
• constant differential pressure.
By means of an external sensor Control MPC Series
2000 can also ensure optimum adaptation of the
performance to the demand by closed-loop control of:
• differential pressure (remote)
• flow
• temperature.
Note: For further information about Control MPC and
Control MPC Series 2000, see the data booklet titled
Control MPC. The data booklet is available in
WebCAPS, on www.grundfos.com. For further
information on WebCAPS, see page 142

35
Grundfos CUE TP, TPD, TPE, TPED

TP pumps connected to Functions


Grundfos CUE, external frequency Intuitive start-up guide
converters The start-up guide enables easy installation and
commissioning as well as plug-and-pump convenience.
Few settings need to be made by the installer as the
rest is done automatically or preset from the factory.

Smart user interface

TM04 3283 4108


GrA 4404

Fig. 19 Grundfos CUE product range


Grundfos CUE is a complete range of wall-mounted Fig. 20 Grundfos CUE user interface
frequency converters for pump control in a wide range
Grundfos CUE features a unique user-friendly control
of applications.
panel with graphic display and easy-to-use buttons.
Grundfos CUE provides a variety of benefits to the end- Panel layout resembles the well-known Grundfos R100
user. remote control, which is used with Grundfos E-pumps.
The benefits include: Controlling the value you choose
• Grundfos E-pump functionality and user interface. Grundfos CUE has a built-in PI controller offering
• Application- and pump family-related functions. closed-loop control of a desired value.
• Increased comfort compared to fixed-speed pump The values include:
solutions.
• constant differential pressure
• Simple installation and commissioning compared to
• proportional pressure
standard frequency converters.
• constant temperature
• Enables speed control of pumps up to 250 kW.
• constant differential pressure
• constant flow.

Wide product range


The CUE product range is quite comprehensive,
covering five different voltage ranges, enclosure
classes IP20/21 (Nema 1) and IP54/55 (Nema 12),
and a wide range of output powers.
The table below provides a general overview.

Input voltage [V] Output voltage [V] Motor [kW]


1 x 200-240 3 x 200-240 1.1 - 7.5
3 x 200-240 3 x 200-240 0.75 - 45
3 x 380-500 3 x 380-500 0.55 -250
3 x 525-600 3 x 525-600 0.75 -7.5
3 x 525-690 3 x 525-690 11 - 250

36
Motor data TP, TPD, TPE, TPED

Motors Motor range

Motors fitted on TP pumps are totally enclosed, fan- Electronically speed-


Mains-operated motors
cooled motors with main dimensions to IEC and DIN kW controlled motors
2-pole 4-pole 6-pole 2-pole 4-pole
standards. Electrical tolerances to IEC 34.
0.12 MEZ
Mounting designation 0.18 MEZ
0.25
Pump type Mounting designation - IEC 34-7 0.37
TP Series 100 0.55
IM 3601 (IM B 14) / IM 3611 (IM V 18)
TP Series 200
0.75
TP Series 300 IM 3001 (IM B 5) / IM 3011 (IM V 1) MG
1.1
TP Series 400 IM 3001 (IM B 5) / IM 3011 (IM V 1)
1.5
Relative humidity: Max. 95 % 2.2 MG
Enclosure class: IP 55 3.0 MGE
Siemens MGE
Insulation class: F, to IEC 85 4.0
Ambient temperature: Max. +55 °C (EFF1 motors) 5.5
Max. +40 °C (other motors) 7.5

Min. –30 °C 11.0


15.0
If the pump is installed in humid locations, open the 18.5
lowest drain hole in the motor. This will reduce the 22.0
motor enclosure class to IP 44. 30.0
37.0
45.0
Siemens
55.0
75.0
90.0 Siemens
110.0
132.0
160.0
200.0
250.0
315.0
355.0
400.0
500.0
560.0
630.0
MG and MGE are Grundfos motor brands.
Siemens is a sourced high-quality motor brands.
The grey-shaded areas indicate non-available motors.

High-efficiency motors
TP pumps are fitted with high-efficiency motors.
TP, TPD pumps with 2- and 4-pole three-phase motors
from 1.1 to 90 kW are equipped with EFF1 motors.
TPE, TPED pumps with three-phase motors, 2-pole
from 1.1 to 22 kW and 4-pole from 1.1 to 15 kW, are
equipped with motors equivalent to EFF1.
EFF1 is the highest efficiency class defined by CEMEP
(European Committee of Manufacturers of Electrical
Machines and Power Electronics).

37
Motor data TP, TPD, TPE, TPED

Motor protection
MG, Siemens
Single-phase motors have integrated, interconnected
thermal switches.
Three-phase motors must be connected to a motor-
protective circuit breaker.
All three-phase mains-operated motors can be
connected to an external frequency converter.
If you connect a frequency converter, the motor
insulation system will often be overloaded, and the
motor will be more noisy than in normal operation. In
addition, large motors will be exposed to bearing
currents caused by the frequency converter.
If you operate the motor via a frequency converter,
consider the following:
• In 2-, 4- and 6-pole motors of 45 kW (frame size
225) and upwards, isolate one of the motor bearings
electrically to prevent damaging currents from
passing through the motor bearings.
• If you have noise-sensitive applications, you can
reduce the motor noise by fitting a dU/dt filter
between the motor and the frequency converter.
For particularly noise-sensitive applications, we
recommend a sinusoidal filter.
• The length of the cable between motor and
frequency converter affects the motor load.
Therefore, check that the cable length meets the
specifications laid down by the frequency converter
supplier.
• For supply voltages between 500 and 690 V, fit
either a dU/dt filter to reduce voltage peaks, or use
a motor with reinforced insulation.
• For supply voltages of 690 V, use a motor with
reinforced insulation, and fit a dU/dt filter.

MGE
MGE motors with built-in frequency converter do not
require protection by a motor-protective circuit breaker.

38
Motor data TP, TPD, TPE, TPED

Electrical data, mains-operated motors


Electrical data, 2-pole 1 x 220-230/240 V Electrical data, 4-pole 1 x 220-230/240 V

Motor IStart Motor IStart


I1/1 [A] Cos ϕ 1/1 η [%] n [min-1] ------------ I1/1 [A] Cos ϕ 1/1 η [%] n [min-1] ------------
[kW] I 1/1 [kW] I 1/1
0.12 1.05 1.0 65 2800-2840 3.2-3.6 0.12 0.99 0.99 53.1 1434 2.58
0.25 2.05/2 0.99 58 2800 - 0.18 1.62 0.97 54 1350-1370 2.0
0.37 2.95/2.7 0.99 60 2770 2.8 0.25 2.14 0.97 57 1350-1370 2.2
0.55 4/3.65 0.99 66 2750 2.8 0.37 2.85 0.97 62 1350-1370 2.4
0.75 5.1/4.75 0.99 69 2780 3.0 0.55 4 0.97 66 1350-1370 2.6
1.1 7.4/6.7 0.98-0.99 - 2770 3.9/3.9 0.75 5.45 0.96 71 1390-1410 3.2
1.5 9.9/8.9 0.98-0.99 72-74 2750-2740 3.9/3.9 1.1 7 0.96 75 1420-1430 3.9

Electrical data, 2-pole 3 x 220-240/380-415 V Electrical data, 4-pole 3 x 220-240/380-415 V

IStart Motor IStart


Motor [kW] I1/1 [A] Cos ϕ 1/1 η [%] n [min-1] ------------ I1/1 [A] Cos ϕ 1/1 η [%] n [min-1] ------------
I 1/1 [kW] I 1/1
0.12 0.59/0.34 0.8-0.72 71 2800 -2850 4.2-4.6 0.12 0.78/0.45 0.67 54 1380 3.2
0.18 0.9/0.52 0.79-0.71 67 2800-2850 4.5 0.25 1.48/0.85 0.75-0.65 69 1400-1420 4.0-4.4
0.25 1.18/0.68 0.81-0.72 73 2800 -2850 4.0-4.4 0.37 1.9/1.1 0.77-0.67 71 1400-1420 4.0-4.4
0.37 1.74/1 0.8-0.7 77.5-77.5 2850-2880 - 0.55 2.6/1.5 0.79-0.7 77 1390-1410 4.3-4.7
0.55 2.5/1.44 0.8-0.7 79-79 2830-2850 - 0.75 3.3/1.9 0.79-0.7 78 1390-1410 4.3-4.7
0.75 3.3/1.9 0.81-0.71 80-80 2840-2870 - 1.1 4.3/2.5 0.76 83.8 1430 6.1
1.1 4.10/2.35 0.87-0.82 84 2890-2910 7.4-8.0 1.5 5.9/3.4 0.76 85 1430 6.4
1.5 5.45/3.15 0.87-0.82 85.5 2890-2910 8.5-9.3 2.2 9/5.2 0.71 86.4 1450 6.0
2.2 7.70/4.45 0.89-0.87 87.5 2890-2910 8.5-9.5 3.0 11.8/6.75 0.81-0.73 87.5 1450-1460 6.7-7.3
3.0 10.4/5.95 0.88-0.85 88-88 2910-2930 - 4.0 14.7/8.5 0.77 88.3 1450 6.1
4.0 13.8/8 0.88-0.84 89 2910-2930 11.2-12.3 5.5 18.4/10.6 0.84 89.5 1460 7.0
5.5 19.4/11.2 0.88-0.84 90 2910-2930 10.7-11.7 7.5 24.8/14.4 0.84 90.3 1460 7.0
7.5 26.5/15.2 0.87-0.8 89.5 2900-2920 10.0-11.1 11.0 35.5/20.4 0.85 91.5 1460 6.9
11.0 33.6/19.4 0.90 91 2950 7.0 15.0 47.5/27.5 0.86 92 1460 7.0
15.0 45.6/26.3 0.90 91.5 2950 7.0 18.5 60/35.5 0.84 92.5 1470 7.0
18.5 54.6/31.5 0.92 92.3 2940 7.0 22.0 70/40.5 0.84 93 1470 7.3
22.0 65.8/38 0.89 93 2950 7.2 30.0 92/53 0.87 93.5 1470 7.0
30.0 90.1/52 0.89 93.5 2950 7.0

Electrical data, 2-pole 3 x 380-415/660-690 V

Motor IStart
I1/1 [A] Cos ϕ 1/1 η [%] n [min-1] ------------
[kW] I 1/1
2.2 4.45 0.89-0.87 87.5-87.5 2890-2910 -
3.0 5.95 0.88-0.85 88-88 2910-2930 -
4.0 8 0.88-0.84 89-89 2910-2930 -
5.5 11.2 0.88-0.84 90-90 2910-2930 -
7.5 15.2 0.87-0.80 89.5-89.5 2900-2920 -
11.0 19.4/11.2 0.90 91 2950 7.0
15.0 26.3/15.2 0.90 91.5 2950 7.0
18.5 31.5/18.2 0.92 92.3 2940 7.0
22.0 38.0/21.9 0.89 93 2950 7.2
30.0 52/30 0.89 93.5 2950 7.0
37.0 64/37 0.89 94 2950 7.0
45.0 77/44.5 0.89 94.9 2970 7.3
55.0 93/53.7 0.9 95.3 2980 6.8
75.0 128/73.9 0.89 95.2 2980 7.0
90.0 150/86.6 0.9 95.6 2980 7.6
110.0 182/105 0.91 95.8 2980 6.9
132.0 220/127 0.91 96.0 2980 7.1
160.0 260/150 0.92 96.4 2980 7.1

39
Motor data TP, TPD, TPE, TPED

Electrical data, 4-pole 3 x 380-415/660-690 V Electrical data, speed-controlled


Motor IStart
motors
I1/1 [A] Cos ϕ 1/1 η [%] n [min-1] ------------
[kW] I 1/1
2.2 5.2/3.0 0.71 86.4 1450 6.0 Electrical data, 2-pole 1 x 220-240 V, 2900 min-1
3.0 6.5/3.8 0.77 87.4 1440 6.3
Motor [kW] I1/1 [A]
4.0 8.5/4.9 0.77 88.3 1450 6.1
0.37 2.7-2.5
5.5 10.6/6.1 0.84 89.5 1460 7.0
0.55 3.9-3.6
7.5 14.4/8.3 0.84 90.3 1460 7.0
0.75 5.1-4.7
11.0 20.6/11.8 0.85 91.5 1460 6.9
1.1 7.1-6.6
15.0 27.5/16 0.96 92 1460 7.0
18.5 34.5/20 0.84 92.5 1470 7.0 Electrical data, 2-pole 3 x 380-480 V, 2900 min-1
22.0 40.5/23.4 0.84 93 1470 7.3
30.0 53.0/30.5 0.87 93.5 1470 7.0 Motor [kW] I1/1 [A]
37.0 67.0/38.5 0.85 94 1480 6.8 0.75 2.0-1.8
45.0 81.0/47.0 0.85 94.5 1480 6.9 1.1 2.6-2.3
55.0 96.0/55.5 0.87 95.1 1490 7.5 1.5 3.3-2.7
75.0 130.0/75.0 0.87 95.1 1490 6.8 2.2 4.6-3.8
90.0 158.0/91.0 0.86 95.4 1490 7.5 3.0 6.2-5.0
110.0 190.0/110.0 0.87 95.9 1490 7.1 4.0 8.1-6.6
132.0 225.0/130.0 0.88 96.1 1490 7.3 5.5 11.0-8.8
160.0 275.0/160.0 0.88 96.3 1490 7.4 7.5 14.8-11.6
200.0 340.0/196.0 0.88 96.4 1490 7.6 11.0 22.5-18.8
250.0 425.0/245.0 0.88 - 1488 - 15.0 30-26.0
315.0 540.0/312.0 0.88 - 1488 - 18.5 37-31.0
355.0 610.0/350.0 0.87 - 1488 - 22.0 43.5-35.0
400.0 690.0/400.0 0.87 - 1488 -
500.0 850.0/490.0 0.88 - 1488 - Electrical data, 4-pole 1 x 220-240 V, 1450 min-1
560.0 950.0/550.0 0.88 - 1492 -
Motor [kW] I1/1 [A]
630.0 1060.0/610.0 0.88 - 1492 -
0.37 2.8-2.6
Electrical data, 6-pole 3 x 220-240/380-415 V 0.55 4.0-3.6
0.75 5.3-4.85
Motor IStart
I1/1 [A] Cos ϕ 1/1 η [%] n [min-1]
[kW] ------------
I 1/1 Electrical data, 4-pole 3 x 380-480 V, 1450 min-1
1.5 6.30/3.65 0.70 85 950 6.2
Motor [kW] I1/1 [A]
2.2 9.35/5.4 0.70 84 955 6.2
0.55 1.5-1.6
3.0 10.5/6.1 0.85 84 955 6.6
0.75 1.8-1.9
4.0 14.8/8.5 0.81 84 950 6.3
1.1 2.5-2.2
5.5 20.8/12.0 0.77 86 960 7.3
1.5 3.3-2.9
7.5 29.5/17.2 0.72 88 965 5.5
2.2 4.6-3.8
Electrical data, 6-pole 3 x 380-415/660-690 V 3.0 6.2-5.0
4.0 8.1-6.6
Motor IStart 5.5 11-9.0
I1/1 [A] Cos ϕ 1/1 η [%] n [min ]-1
------------
[kW] I 1/1 7.5 15.0-12.0
2.2 5.40/3.10 0.70 84 955 6.2 11.0 22.0-17.8
3.0 6.10/3.50 0.84 84 955 6.9 15.0 30.0-25.4
4.0 8.50/4.90 0.81 84 950 6.3 18.5 37.0-30.0
5.5 12.0/6.95 0.77 96 960 7.3
7.5 17.2/9.85 0.72 88 965 5.5

40
Installation TP, TPD, TPE, TPED

Mechanical installation Twin-head pump housings have two Rp 1/4 tappings


(TP Series 200) or four Rp 1/8 tappings (TP Series 300)
TP, TPD, TPE, TPED pumps with motors smaller than
for mounting of automatic air vents.
11 kW can be installed in horizontal or vertical
pipework.

TM02 7533 3703


TM00 3734 0897
Fig. 24 Tappings for mounting of automatic air vents in TP
Series 200 and TP Series 300
Fig. 21 Installation of motor sizes smaller than 11 kW
For further information about identification of
TP, TPD, TPE, TPED pumps with motors of 11 kW and TP Series 200 and TP Series 300 models, see page 22
up may only be installed in horizontal pipes with the to 24.
motor in vertical position.
If the liquid temperature falls below the ambient
temperature, condensation may form in the motor
during inactivity. In this case, the drain hole in the motor
flange must be open and points downwards.
See fig. 25.
TM00 3735 0897

TM00 9831 3202


Fig. 22 Installation of motor sizes of 11 kW and up
Note: The motor must never point downwards.
Install the pumps in such a way that strain from the
pipework is not transferred to the pump housing.
Fig. 25 Drain hole
Pumps with motors smaller than 11 kW may be
If twin-head pumps are used for pumping liquids with a
suspended direct in the pipes, provided the pipework
temperature below 0 °C/32 °F, condensed water may
can support the pump. If not, install the pump on a
freeze and cause the coupling to get stuck. The
mounting bracket or base plate.
problem can be remedied by installing heating
Pumps with motors of 11 kW and up may only be elements. Whenever possible, pumps with motors
installed in horizontal pipes with the motor placed in smaller than 11 kW should be installed with horizontal
vertical position. Always install the pump on an even motor shaft. See fig. 23.
and rigid foundation.
When installing a twin-head pump in a horizontal pipe
and with horizontal shaft, fit the upper pump housing
with an automatic air vent.
TM03 8127 0507

Fig. 23 Twin-head pumps with automatic air vent

41
Installation TP, TPD, TPE, TPED

Cooling Elimination of noise and vibrations


To ensure sufficient cooling of motor and electronics, In order to achieve optimum operation and minimum
observe the following: noise and vibration, consider vibration dampening of
the pump. Generally, always consider this for pumps
• Place the pump in such a way that sufficient cooling
is ensured. with motors of 11 kW and up, but for motors of 90 kW
and up vibration dampening should be considered as
• Make sure that the temperature of the cooling air
mandatory. Smaller motor sizes, however, may also
does not exceed +40 °C.
cause undesirable noise and vibration.
• Keep the motor cooling fins, holes in fan cover and
fan blades clean. Noise and vibration are generated by the revolutions of
• Make sure the frequency for the motor is at least the motor and pump and by the flow in pipes and
6 Hz (12 % of maximum speed). The shaft seal fittings. The effect on the environment is subjective and
could make noise at speeds below 25% of depends on correct installation and the state of the
maximum speed. remaining system.

Condensation cover for TPE pumps Elimination of noise and vibrations is best achieved by
When installing TPE pumps outdoors, provide the means of a concrete foundation, vibration dampers and
motor with a suitable cover to avoid condensation on expansion joints.
the electronic components and to protect the pump and
motor against the direct effects of the elements.
When mounting the condensation cover on top of the
motor, make sure to leave enough space for the air to Concrete foundation Expansion joint
cool the motor.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

TM02 4993 2102


••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•• • • • • •••••••••••••••••••••
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••••••••••••••••••••••
•••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
•••••••••••••••••••• ••••••••••••••••••••

Vibration dampers
TM02 8514 0304

Fig. 27 Foundation of TP pump

Concrete foundation
Install the pump on a plane and rigid concrete
Fig. 26 Speed-controlled motors with condensation cover
foundation. This is the optimum solution for vibration
dampening. As a rule of thumb, the weight of a concrete
foundation should be 1.5 times the pump weight.

42
Installation TP, TPD, TPE, TPED

Recommended concrete foundations for


TP(D )Series 300 pumps Vibration dampers
For TP Series 300 pumps with weights of 150 kg or To prevent the transmission of vibrations to buildings,
more, it is recommended to mount the pump on a we recommend you to isolate the pump foundation from
concrete foundation with the dimensions stated in the building parts by means of vibration dampers.
table below. The same recommendation applies for The selection of the right vibration damper requires the
TPD Series 300 pumps with weights of 300 kg or more. following data:
• forces transmitted through the damper
• motor speed considering speed control, if any
• required dampening in % (suggested value is 70 %).
Which is the right damper varies from installation to
installation, and a wrong damper may increase the
vibration level. Vibration dampers should therefore be
sized by the supplier.
TM03 9190 3507

If you install the pump on a foundation with vibration


dampers, always fit expansion joints on the pump
flanges. This is important to prevent the pump from
"hanging" in the flanges.
Fig. 28 Foundation for TP(D) Series 300 pumps

Concrete foundation dimensions


Pump mass Y (Height) Z (Length) X (Width)
[kg] [mm] [mm] [mm]
150 280 565 565
200 310 620 620
250 330 670 670
300 360 710 710
350 375 750 750
400 390 780 780
450 410 810 810
500 420 840 840
550 440 870 870
600 450 900 900
650 460 920 920
700 470 940 940
750 480 970 970
800 490 990 990
850 500 1010 1010
900 510 1030 1030
950 520 1050 1050
1000 530 1060 1060
1050 540 1080 1080
1100 550 1100 1100
1150 560 1100 1100
1200 560 1130 1130
1250 570 1150 1150
1300 580 1160 1160
1350 590 1180 1180
1400 600 1190 1190
1450 600 1200 1200
1500 610 1220 1220
1550 620 1230 1230
1600 620 1250 1250
1650 630 1250 1250
1700 635 1270 1270

43
Installation TP, TPD, TPE, TPED

Expansion joints Due to the risk of rupture of the rubber bellows, metal
Install expansion joints to bellows expansion joints may be preferred at
temperatures above +100 °C combined with high
• absorb expansions/contractions in the pipework
pressure.
caused by changing liquid temperature.
• reduce mechanical strains in connection with Terminal box positions
pressure surges in the pipework.
TP single-head pumps
• isolate mechanical structure-borne noise in the
As standard, the terminal boxes of TP and TPE pumps
pipework (only rubber bellows expansion joints).
are mounted in position 9 o’clock.
Note: Do not install expansion joints to compensate for
The possible terminal box positions are shown below.
inaccuracies in the pipework such as centre
displacement of flanges.
Fit expansion joints at a distance of minimum 1 to 11/2
times the nominal flange diameter away from the pump
on the suction as well as on the discharge side. This will
prevent the development of turbulence in the expansion
joints, resulting in better suction conditions and a

TM03 0565 2005


minimum pressure loss on the pressure side. At high
Position
Stellung 3 Position
Stellung 6 Position
Stellung 9 Position
Stellung 12
water velocities (> 5 m/s) we recommend you to install 3 o’clock 6 o’clock 9 o’clock 12 o’clock
larger expansion joints corresponding to the pipework. Standard

The illustration below shows examples of rubber


Fig. 31 Possible terminal box positions
bellows expansion joints with or without limit rods.
Note: Due to the motor construction the terminal boxes
of some TP pumps with motor sizes above 250 kW are
TM02 4979 1902 - TM02 4981 1902

mounted in position 10:30.

Fig. 29 Examples of rubber bellows expansion joints


Expansion joints with limit rods can be used to reduce
the effects of the expansion/contraction forces on the
pipework. We always recommend expansion joints with
limit rods for flanges larger than DN 100.
Anchor the pipes in such a way that they do not stress
the expansion joints and the pump. Follow the
supplier’s instructions and pass them on to advisers or
pipe installers.
The illustration below shows an example of a metal
bellows expansion joint with limit rods.
TM02 4980 1902

Fig. 30 Example of metal expansion joint

44
Installation TP, TPD, TPE, TPED

TPD twin-head pumps


TPED pumps with terminal boxes in position 10:30 and 13:30
As standard, the terminal boxes of all TPD and most Single-phase [kW] Three-phase [kW]
TPED pumps are mounted in position 12 o’clock, see TPED 32-60/2 0.37 TPED 32-230/2 0.75
fig. 31. The TPED pumps with terminal boxes in TPED 32-120/2 0.37 TPED 32-200/2 1.1
position 10:30 and 13:30 are listed in the table. TPED 40-60/2 0.37 TPED 32-250/2 1.5
TPED 40-120/2 0.37 TPED 32-320/2 2.2
TPED 50-60/2 0.37 TPED 32-380/2 3.0
TPED 32-30/4 0.37 TPED 32-460/2 4.0
TPED 40-30/4 0.37 TPED 32-580/2 5.5
TPED 50-30/4 0.37 TPED 40-190/2 0.75
TPED 40-230/2 1.1
TPED 40-270/2 1.5
TPED 40-240/2 2.2

TM02 8630 0604


TPED 40-300/2 3.0
TPED 40-360/2 4.0
TPED 40-470/2 5.5
B4 B4
TPED 40-580/2 7.5
TPED 50-120/2 0.75
Fig. 32 Terminal box positions of TPED pumps
TPED 50-160/2 1.1
Note: The B4 dimension can be seen in the tables of TPED 50-180/2 0.75
technical data of the individual pump. See the sections TPED 50-190/2 1.5
on performance curves and technical data. TPED 50-240/2 2.2
TPED 50-290/2 3.0
TPED 50-360/2 4.0
TPED 50-430/2 5.5
TPED 50-570/2 11
TPED 50-710/2 15
TPED 50-830/2 18.5
TPED 50-900/2 22
TPED 65-120/2 1.1
TPED 65-180/2 1.5
TPED 65-190/2 2.2
TPED 65-230/2 3.0
TPED 65-260/2 4.0
TPED 65-340/2 5.5
TPED 65-410/2 7.5
TPED 65-460/2 11
TPED 65-550/2 15
TPED 65-660/2 18.5
TPED 65-720/2 22
TPED 80-120/2 1.5
TPED 80-210/2 4.0
TPED 80-240/2 5.5
TPED 80-330/2 11
TPED 80-400/2 15
TPED 80-520/2 18.5
TPED 80-570/2 22
TPED 100-120/2 2.2
TPED 65-60/4 0.55
TPED 65-90/4 0.75
TPED 80-60/4 0.75
TPED 100-30/4 0.55
TPED 100-60/4 1.1

45
Installation TP, TPD, TPE, TPED

Electrical installation Protection against voltage peaks


If you use speed controllers or frequency converters of
Electrical connection other makes than Grundfos, you may have the following
Carry out electrical connection and protection in problems:
accordance with local regulations.
• increased motor noise
• The pump must be connected to an external mains • detrimental voltage peaks
switch with a minimum contact gap of 3 mm in all
• additional motor losses.
poles.
Pumps with voltage peaks exceeding 650 V (maximum
• Electronically speed-controlled pumps must always
be correctly earthed. value) must therefore be protected. The voltage
Note: The 4.0 - 22 kW motors must be connected to increase rate dU/dt must not exceed 500 Vμs. Noise
especially reliable/sturdy earth connections to avoid and detrimental voltage peaks can be prevented by
earth leakage currents above 3.5 mA. fitting an LC filter between the speed controller and the
• Single-phase motors incorporate thermal protection motor.
and require no additional motor protection.
Communication cables for TPE, TPED
• Three-phase mains-operated motors must be Use screened cables (min. 0.5 mm2) for external on/off
connected to a motor-protective circuit breaker.
switch, digital input, sensor and setpoint signals. The
• Motors as from 3 kW incorporate thermistors (PTC). screens of the cables should be connected to frame at
The thermistors are designed according to both ends.
DIN 44082.
• When the pump is switched on via the mains, the The screen of the cable must have good frame
pump will start after approx. 5 seconds. connection which must be as close as possible to the
terminals.
Note: Carry out the mains connection of the pump as
shown in the diagram inside the terminal box cover.
Do not start the pump until it has been filled with liquid
and vented. Screen

TM02 1325 0901


Protection

Protection against fault currents


If the pump is connected to an electric installation
where an earth leakage circuit breaker (ELCB) is used
Fig. 33 External start/stop cable connection of TPE,
as additional protection, the earth leakage circuit
TPED
breaker must be marked with the following symbols.
Use a screened 2-core cable for the bus connection.
• Single-phase:
Connect the screen to terminal Y at both ends.

The earth leakage circuit breaker must trip out


when earth fault currents with DC content
(pulsating DC) occur. Screen
TM02 1343 1001

• Three-phase:
Y

The earth leakage circuit breaker must trip out


when earth fault currents with DC content (pulsating
DC) and smooth DC earth fault currents occur. Fig. 34 Bus connection of TPE, TPED

46
Installation TP, TPD, TPE, TPED

Other connections, TPE, TPED Wiring diagram, three-phase, 0.75 - 7.5 kW


See the wiring diagrams for instructions on how to
connect external potential-free contacts for start/stop

Group 2

Group 3
and digital function, external setpoint signal and fault
signal. NC C NO L1 L2 L3

Connect the wires to the following terminal groups:

Group 1: Inputs (external start/stop, digital function,


setpoint and sensor signals, terminals 1-9
and bus connection, A, Y, B).
All inputs are separated from the mains
conducting parts by reinforced insulation.

Group 2: Output (signal relay). 0-10 V


0/4-20 mA 4-20 mA
The output, terminals C, NO and NC, are
galvanically separated from other circuits. 1/0

Group 1
Therefore, the supply voltage or protective
extra-low voltage can be connected to the 1 9 8 7 B Y A

output as desired.
STOP

TM02 8414 5103


RUN

Group 3: Mains supply. 0/4-20 mA 0-10 V


10K

Note:
• As a precaution, separate the wires from each other 6 5 4 3 2

by reinforced insulation in their entire lengths.


• If no external on/off switch is connected, maintain Fig. 36 Wiring diagram, three-phase TPE pumps
the connection across terminals 2 and 3. Wiring diagram, three-phase, 11 - 22 kW
Wiring diagram, single-phase
Group 2

Signal relay Mains connection Group 3


Group 2

Group 3

NC C NO N PE L

0-10 V
0/4-20 mA 4-20 mA

0/1

1 9 8 7 B Y A
Group 1
Group 1

STOP

RUN
TM03 8608 2007

0/4-20 mA 0-10 V
TM02 0795 0101

10K

6 5 4 3 2

Fig. 37 Wiring diagram, three-phase TPE pumps


Fig. 35 Wiring diagram, single-phase TPE pumps

47
Flanges for TP pumps TP, TPD, TPE, TPED

Flange dimensions
PN 6 and PN 10 flanges

EN 1092-2 PN 6 (0.6 MPa) EN 1092-2 PN 10 (1.0 MPa)


D1 Nominal diameter (DN) Nominal diameter (DN)
S

32 40 50 65 80 100 32 40 50 65 80 100 125 150 200 250


D1 32 40 50 65 80 100 32 40 50 65 80 100 125 150 200 250
TM02 7720 3803

D2 90 100 110 130 150 170 100 110 125 145 160 180 210 240 295 350
D3 120 130 140 160 190 210 140 150 165 185 200 220 250 285 340 395
D2
D3 S 4x14 4x14 4x14 4x14 4x19 4x19 4x19 4x19 4x19 4x19 8x19 8x19 8x19 8x23 8x23 12x23

PN 16 and PN 25 flanges

EN 1092-2 PN 16 (1.6 MPa) EN 1092-2 PN 25 (2.5 MPa)


D1
Nominal diameter (DN) Nominal diameter (DN)
S

32 40 50 65 80 100 125 150 200 100 125 150 200 250 300 350
D1
TM02 7720 3803

32 40 50 65 80 100 125 150 200 100 125 150 200 250 300 350
D2 100 110 125 145 160 180 210 240 295 190 220 250 310 370 430 490
D3 140 150 165 185 200 220 250 285 340 235 270 300 360 425 485 555
D2
D3 S 4x19 4x19 4x19 4x19 8x19 8x19 8x19 8x23 12x23 8x23 8x28 8x28 12x28 12x31 16x31 16x34

PN 40 flanges

EN/DIN 2635 PN 40
D1 (4.0 MPa)
S

Nominal diameter (DN)


400 500
D1
TM02 7720 3803

400 500
D2 585 585
D2 D3 660 660
D3
S 16x42 20x42

48
Curve charts TP, TPD, TPE, TPED

How to read the curve charts

H
[m]
60 TP, TPE 32
-580/2 Pump type and frequency
50 Hz
55
50
-460/2
45 QH curve for the individual single-head pump.
40 -380/2 The bold curve indicates the recommended
35 performance range.
-320/2
30
-250/2
25
-200/2
20
15
10
0 4 8 12 16 20 24 Q [m³/h]
P2
[kW]
6
-580/2
5

4 -460/2 The power curve indicates pump


input power [P2].
3 -380/2
-320/2
2
-250/2
1 -200/2

0
0 4 8 12 16 20 24 Q [m³/h]
NPSH
[m]

16
The NPSH (3 %) curve shows the
12 required net positive suction head
(NPSH) to ensure that the pump head
8 is not reduced by more than 3 %. The
available system pressure at the
4
pump inlet must be according to the
0 NPSH(3%) curve + a safety margin of
0 4 8 12 16 20 24 Q [m³/h] at least 0.5 m.
Eta
[%]
-250/2
60 -200/2 -320/2

55 -380/2

50 -580/2
-460/2
45 The eta curve shows the pump
40 efficiency.

35

30
0 4 8 12 16 20 24 Q [m³/h]
TM02 5017 2102

0 2 4 6 Q [l/s]

0 2 4 6 v [m/s]

49
Curve charts TP, TPD, TPE, TPED

Curve conditions
The guidelines below apply to the curves shown on the
following pages:
1. Tolerances to ISO 9906, Annex A.
2. The curves apply to the performance of single-
head three-phase pumps. For other pump
versions, please see the exact curves in WinCAPS
or WebCAPS. For other pump versions, the
performance may differ for the following reasons:
- The valve in twin-head pumps may cause losses.
- Single-phase motors run at lower speed.
Note: Grundfos does not recommend continuous
parallel operation of twin-head pumps due to the
increased flow in the pump. A too high flow results
in noisy operation, increased wear of the impeller
due to cavitation, etc.
3. QH curves of the individual single-head pumps are
shown with expected speed of a three-phase mains-
operated motor. For further information, see the
tables of technical data on the following pages.
The performance of the single-phase motor is
slightly reduced. Please refer to WinCAPS or
WebCAPS for the exact single-phase curves.
4. Curves of TPE Series 1000 pumps and TPE Series
2000 pumps are shown as max. curves (100 %
curves) only. Please refer to WinCAPS for the exact
curves.
5. Measurements have been made with airless water
at a temperature of +20 °C.
6. The curves apply to a kinematic viscosity of
υ = 1 mm2/s (1 cSt).
7. Due to the risk overheating, the pump must not run
constantly below the minimum flow rate indicated by
the bold curves.
8. If the pumped liquid density and/or viscosity are
higher than those of water, it may be necessary to
use a motor with a higher performance.

50
51
Technical data/ G 1 1/2
2-pole, PN 6, 10, 16
performance curves
TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16
TP, TPE 25-XX /2 R

H
[m]
9
-90/2 R TP, TPE 25
50 Hz
8

6
-50/2 R

1
0 1 2 3 4 5 6 7 8 Q [m³/h]
P2
[kW]
0.20

0.16
-90/2 R
0.12

0.08 -50/2 R

0.04

0.00
0 1 2 3 4 5 6 7 8 Q [m³/h]
NPSH
[m]

4
-50/2 R, -90/2 R
3

0
0 1 2 3 4 5 6 7 8 Q [m³/h]
Eta
[%]
50

45

40
-90/2 R
35
-50/2 R
30

25

20
0 1 2 3 4 5 6 7 8 Q [m³/h]
TM02 5014 0504

0.0 0.5 1.0 1.5 2.0 Q [l/s]

0 1 2 3 4 v [m/s]

52
Technical data G 1 1/2
2-pole, PN 6, 10, 16

B4 B4
AC
AC
AD
AD

H3
H3
H2

G
H1
B1 B2 L1

TM02 8348 3307


AF
AE

Technical data

TP 25 -50/2 R -90/2 R
TPD - -
TPE z z
TPED - -
Series 100 100
1-phase TP 63 71
3-phase TP 63 63
IEC size
1-phase TPE 71 71
3-phase TPE - -
1-/3-phase TP [kW] 0.12/0.12 0.25/0.25
P2
1-/3-phase TPE [kW] 0.37/- 0.37/-
PN 10 10
Tmin ; Tmax [°C] [-25;110] [-25;110]
G G1½ G1½
1-/3-phase TP [mm] 118/118 139/118
AC
1-/3-phase TPE [mm] 141/- 141/-
1-/3-phase TP [mm] 101/101 111/101
AD
1-/3-phase TPE [mm] 140/- 140/-
AE 1-/3-phase TPE [mm] 105/- 105/-
AF 1-/3-phase TPE [mm] 105/- 105/-
B1 [mm] 54 54
B2 [mm] 52 52
1-/3-phase TP [mm] 101/- 111/-
B4
1-/3-phase TPE [mm] 140/- 140/-
L1 [mm] 180 180
H1 [mm] 25 25
H2 [mm] 118 118
1-/3-phase TP [mm] 323/323 353/323
H3
1-/3-phase TPE [mm] 334/- 334/-

53
Performance curves G2
2-pole, PN 6, 10, 16

TP, TPE 32-XX/2

H
[m]
9
TP, TPE 32
-90/2 R
50 Hz
8

6
-50/2 R
5

1
0 1 2 3 4 5 6 7 8 9Q [m³/h]
P2
[kW]
-90/2 R
0.20

0.16

0.12 -50/2 R

0.08

0.04

0.00
0 1 2 3 4 5 6 7 8 9Q [m³/h]
NPSH
[m]
3.0 -90/2 R

2.5

2.0

1.5

1.0
-50/2 R
0.5

0.0
0 1 2 3 4 5 6 7 8 9Q [m³/h]
Eta
[%]
55
50 -90/2 R
45
40 -50/2 R
35
30
25
20
0 1 2 3 4 5 6 7 8 9Q [m³/h]
TM02 5015 0504

0.0 0.5 1.0 1.5 2.0 2.5 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 v [m/s]

54
Technical data G2
2-pole, PN 6, 10, 16

B4 B4
AC
AC
AD
AD

H3
H3
H2

G
H1
B1 B2 L1

TM02 8348 5004


AF
AE

Technical data

TP 32 -50/2 R -90/2 R
TPD - -
TPE z z
TPED - -
Series 100 100
1-phase TP 63 71
3-phase TP 63 63
IEC size
1-phase TPE 71 71
3-phase TPE - -
1-/3-phase TP [kW] 0.12/0.12 0.25/0.25
P2
1-/3-phase TPE [kW] 0.37/- 0.37/-
PN 10 10
Tmin ; Tmax [°C] [-25;110] [-25;110]
G G2 G2
1-/3-phase TP [mm] 118/118 139/118
AC
1-/3-phase TPE [mm] 141/- 141/-
1-/3-phase TP [mm] 101/101 111/101
AD
1-/3-phase TPE [mm] 140/- 140/-
AE 1-/3-phase TPE [mm] 105/- 105/-
AF 1-/3-phase TPE [mm] 105/- 105/-
B1 [mm] 51 51
B2 [mm] 60 60
1-/3-phase TP [mm] 101/- 111/-
B4
1-/3-phase TPE [mm] 140/- 140/-
L1 [mm] 180 180
H1 [mm] 40 40
H2 [mm] 118 118
1-/3-phase TP [mm] 338/338 368/338
H3
1-/3-phase TPE [mm] 334/- 334/-

55
Performance curves DN 32
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 32-XX/2

H H
[m] [m]
24 -230/2 TP, TPE 32 60 TP, TPE 32
-580/2
22 50 Hz 50 Hz
55
20
50
18 -460/2
-180/2 45
16
14 40 -380/2

12 -150/2 35 -320/2
-120/2
10 30
8 -250/2
25
6 -60/2 -200/2
20
4
2 15
0 10
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h] 0 4 8 12 16 20 24 Q [m³/h]
P2 P2
[kW] [kW]
0.7 -230/2 6
-580/2
0.6
5
0.5
4 -460/2
-180/2
0.4
-150/2 -120/2 3 -380/2
0.3
-320/2
2
0.2 -250/2
-60/2 1 -200/2
0.1
0.0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h] 0 4 8 12 16 20 24 Q [m³/h]
NPSH NPSH
[m] [m]
10 -150/2, -180/2, -230/2
16
8
12
-120/2
6
8
4 -60/2

2 4

0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h] 0 4 8 12 16 20 24 Q [m³/h]
Eta Eta
[%] [%]
65 -250/2
60 -200/2 -320/2
60
55 55 -380/2
50 -150/2 50 -580/2
45 -460/2
40 -60/2
45
-120/2
35 -230/2 40
30 -180/2
35
25
20 30
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h] 0 4 8 12 16 20 24 Q [m³/h]
TM02 5016 0504

TM02 5017 0504

0.0 0.5 1.0 1.5 2.0 2.5 3.0 Q [l/s] 0 2 4 6 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 v [m/s] 0 2 4 6 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

56
Technical data DN 32
2-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 3307 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 32 -60/2 -120/2 -150/2 -180/2 -230/2 -200/2 -250/2 -320/2 -380/2 -460/2 -580/2
TPD z z z z z z z z z z z
TPE z z z z z z z z z z z
TPED z z z z z z z z z z z
Series 200 200 200 200 200 300 300 300 300 300 300
1-phase TP 71 71 71 80 80 - - - - - -
3-phase TP 63 71 71 71 80 80 90 90 100 112 132
IEC size
1-phase TPE 71 71 71 71 80 80 - - - - -
3-phase TPE - - - - 90 90 90 90 100 112 132
1-/3-phase TP★ [kW] 0.25/0.18 0.25/0.37 0.37/0.37 0.55/0.55 0.75/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5
P2
1-/3-phase TPE [kW] 0.37/- 0.37/- 0.37/- 0.55/- 0.75/0.75 1.1/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5
PN PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 32 32 32 32 32 32 32 32 32 32 32
1-/3-phase TP [mm] 139/118 141/141 141/141 141/141 141/141 -/178 -/178 -/178 -/198 -/220 -/220
AC
1-/3-phase TPE [mm] 141/- 141/- 141/- 141/- 141/178 141/178 -/178 -/178 -/198 -/220 -/220
1-/3-phase TP [mm] 111/101 133/109 133/109 133/109 133/109 -/110 -/110 -/110 -/120 -/134 -/134
AD
1-/3-phase TPE [mm] 140/- 140/- 140/- 140/- 140/167 140/167 -/167 -/167 -/177 -/188 -/188
AE 1-/3-phase TPE [mm] 105/- 105/- 105/- 105/- 105/132 105/105 -/132 -/132 -/132 -/145 -/145
AF 1-/3-phase TPE [mm] 105/- 105/- 105/- 105/- 105/132 105/105 -/132 -/132 -/132 -/145 -/145
P [mm] - - - - - 200 200 200 250 250 300
B1★★ [mm] 75/180 75/180 102/222 102/222 102/222 125/260 125/260 125/260 125/260 144/321 144/321

B2★★ [mm] 75/180 75/180 102/222 102/222 102/222 117/257 117/257 117/257 117/257 144/321 144/321
B3 [mm] 200 200 240 240 240 276 276 276 276 355 355
TP [mm] 111/180 133/180 133/222 133/222 133/222 125/260 125/260 125/260 125/263 144/321 150/328
B4★★ 1-phase TPE [mm] 140/264 140/264 140/225 140/225 140/225 140/338 - - - - -
3-phase TPE [mm] - - - - 167/320 140/338 167/338 167/338 177/344 188/403 188/403
C1★★ [mm] 80/200 80/200 80/240 80/240 80/240 144/356 144/356 144/356 144/356 144/435 144/435
★★ [mm] 110/52 110/52 140/82 140/82 140/82 170/45 170/45 170/45 170/45 220/46 220/46
C5
C6 [mm] 103 103 103 103 103 175 175 175 175 175 175
L1 [mm] 220 220 280 280 280 340 340 340 340 440 440
H1 [mm] 68 68 79 79 79 100 100 100 100 100 100
H2 [mm] 140 126 125 125 137 154 154 154 183 184 223
1-/3-phase TP [mm] 419/388 385/385 395/395 447/395 447/447 -/535 -/535 -/575 -/618 -/656 -/714
H3
1-/3-phase TPE [mm] 407/- 385/- 395/- 395/- 447/497 485/535 -/535 -/575 -/618 -/656 -/714
H4 [mm] - - - - - - - - - - -
M M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

57
Performance curves DN 40
2-pole, PN 6, 10, 16

TP, TPE 40-XX/2

H H
[m] [m]

9
-90/2 TP, TPE 40 28 -270/2 TP, TPE 40
50 Hz 26
-230/2
50 Hz
8 24
22
7
20 -190/2
6 18
-50/2 16
5 14 -180/2

12
4
-120/2
10
3 8
-60/2
6
2
4
1 2
0 1 2 3 4 5 6 7 8 9 Q [m³/h] 0 2 4 6 8 10 12 14 16 Q [m³/h]
P2 P2
[kW] [kW]
-270/2
0.20 1.2
-230/2
-90/2 1.0
0.16
0.8
0.12 -190/2
-50/2 0.6 -180/2
0.08
0.4 -120/2
0.04 0.2 -60/2

0.00 0.0
0 1 2 3 4 5 6 7 8 9 Q [m³/h] 0 2 4 6 8 10 12 14 16 Q [m³/h]
NPSH NPSH
[m] [m]
3.0 -90/2
10 -190/2, -230/2, -270/2

2.5
8 -120/2 -180/2
2.0
-50/2 6
1.5
4
1.0

0.5 2
-60/2
0.0 0
0 1 2 3 4 5 6 7 8 9 Q [m³/h] 0 2 4 6 8 10 12 14 16 Q [m³/h]
Eta Eta
[%] [%]
60 75
-60/2
55 70
-120/2
-50/2 65
50 -180/2
60
45
55
40
50
35 45 -190/2
-90/2
30 40 -270/2
25 35 -230/2
20 30
0 1 2 3 4 5 6 7 8 9 Q [m³/h] 0 2 4 6 8 10 12 14 16 Q [m³/h]
TM02 5018 0504

TM02 5019 0504

0.0 0.5 1.0 1.5 2.0 2.5 Q [l/s] 0 1 2 3 4 5 Q [l/s]

0.0 0.5 1.0 1.5 2.0 v [m/s] 0 1 2 3 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

58
Technical data DN 40
2-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 40 -50/2 -60/2 -90/2 -120/2 -180/2 -190/2 -230/2 -270/2


TPD - z - z - z z z
TPE - z z z z z z z
TPED - z - z - z z z
Series 100 200 100 200 200 200 200 200
1-phase TP 63 71 71 71 80 80 90 90
3-phase TP 63 71 63 71 71 80 90 90
IEC size
1-phase TPE 71 71 71 71 71 80 80 -
3-phase TPE - - - - - 90 90 90
1-/3-phase TP★ [kW] 0.12/0.12 0.25/0.25 0.25/0.25 0.37/0.37 0.55/0.55 0.75/0.75 1.1/1.1 1.5/1.5
P2
1-/3-phase TPE [kW] 0.37/- 0.37/- 0.37/- 0.37/- 0.55/- 0.75/0.75 1.1/1.1 -/1.5
PN PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;110] [-25;140] [-25;110] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]
D1 [mm] 40 40 40 40 40 40 40 40
1-/3-phase TP [mm] 118/118 141/141 139/118 141/141 141/141 141/141 178/141 178/178
AC
1-/3-phase TPE [mm] 141/- 141/- 141/- 141/- 141/- 141/178 141/178 -/178
1-/3-phase TP [mm] 101/101 133/109 111/101 133/109 133/109 133/109 139/109 139/110
AD
1-/3-phase TPE [mm] 140/- 140/- 141/- 140/- 141/- 140/167 140/167 -/167
AE 1-/3-phase TPE [mm] 105/- 105/- 105/- 105/- 105/- 105/132 105/132 -/132
AF 1-/3-phase TPE [mm] 105/- 105/- 105/- 105/- 105/- 105/132 105/132 -/132
P [mm] - - - - - - - -
B1★★ [mm] 75/- 75/180 75/- 75/180 100/- 102/222 102/222 102/222

B2★★ [mm] 75/- 75/180 75/- 75/180 100/- 102/222 102/222 102/222
B3 [mm] - 200 - 200 - 240 240 240
TP [mm] 101/- 133/180 111/- 133/180 133/- 133/222 139/222 139/222
B4★★ 1-phase TPE [mm] 140/275 140/264 141/275 140/264 141/225 140/225 140/225 -
3-phase TPE [mm] - - - - - 167/320 167/320 167/320
C1★★ [mm] -/- 80/200 -/- 80/200 80/- 120/240 120/240 120/240
★★ [mm] -/- 125/45 -/- 125/45 125/- 160/95 160/95 160/95
C5
C6 [mm] - 125 - 125 - 125 125 125
L1 [mm] 250 250 250 250 250 320 320 320
H1 [mm] 55 67 55 67 68 68 68 68
H2 [mm] 118 129 118 129 131 141 141 151
1-/3-phase TP [mm] 353/353 387/366 383/353 387/387 442/390 439/439 499/490 539/500
H3
1-/3-phase TPE [mm] 364/- 395/- 364/- 388/- 390/- 320/490 439/490 -/500
H4 [mm] - - - - - - - -
M - M12 - M12 M12 M12 M12 M12

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

59
Performance curves DN 40
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 40-XX/2

H
[m]
60 -580/2 TP, TPE 40
50 Hz
55
50
-470/2
45
40
-360/2
35
-300/2
30
-240/2
25
20
15
10
0 4 8 12 16 20 24 28 32 Q [m³/h]
P2
[kW]
8
-580/2
7
6
5 -470/2
4 -360/2
3 -300/2
2 -240/2

1
0
0 4 8 12 16 20 24 28 32 Q [m³/h]
NPSH
[m]
10

8 -300/2, 360/2, 470/2, 580/2

6
-240/2
4

0
0 4 8 12 16 20 24 28 32 Q [m³/h]
Eta
[%] -300/2
60
-360/2
55 -240/2
50
-470/2 -580/2
45

40

35

30
0 4 8 12 16 20 24 28 32 Q [m³/h]
TM02 5020 0504

0 2 4 6 8 10 Q [l/s]

0 2 4 6 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

60
Technical data DN 40
2-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 40 -240/2 -300/2 -360/2 -470/2 -580/2


TPD z z z z z
TPE z z z z z
TPED z z z z z
Series 300 300 300 300 300
1-phase TP - - - - -
3-phase TP 90 100 112 132 132
IEC size
1-phase TPE - - - - -
3-phase TPE 90 100 112 132 132
1-/3-phase TP★ [kW] -/2.2 -/3 -/4 -/5.5 -/7.5
P2
1-/3-phase TPE [kW] -/2.2 -/3 -/4 -/5.5 -/7.5
PN PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 40 40 40 40 40
1-/3-phase TP [mm] -/178 -/198 -/220 -/220 -/220
AC
1-/3-phase TPE [mm] -/178 -/198 -/220 -/220 -/260
1-/3-phase TP [mm] -/110 -/120 -/134 -/134 -/134
AD
1-/3-phase TPE [mm] -/167 -/177 -/188 -/188 -/213
AE 1-/3-phase TPE [mm] -/132 -/132 -/145 -/145 -/145
AF 1-/3-phase TPE [mm] -/132 -/132 -/145 -/145 -/145
P [mm] 200 250 250 300 300
B1★★ [mm] 130/273 130/273 130/273 149/325 149/325

B2★★ [mm] 117/267 117/267 117/267 144/321 144/321


B3 [mm] 290 290 290 355 355
TP [mm] 130/273 130/273 134/273 150/328 150/328
B4★★ 1-phase TPE [mm] - - - - -
3-phase TPE [mm] 167/345 177/351 188/370 188/403 213/414
C1★★ [mm] 144/400 144/400 144/400 144/435 144/435
★★ [mm] 170/45 170/45 170/45 220/108 220/108
C5
C6 [mm] 175 175 175 175 175
L1 [mm] 340 340 340 440 440
H1 [mm] 100 100 100 110 110
H2 [mm] 166 194 194 225 225
1-/3-phase TP [mm] -/587 -/629 -/666 -/726 -/726
H3
1-/3-phase TPE [mm] -/587 -/629 -/666 -/726 -/714
H4 [mm] - - - - -
M M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

61
Performance curves DN 50
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 50-XX/2

H
[m]
-290/2 TP, TPE 50
28
50 Hz
24 -240/2

20 -190/2

-160/2
16
-180/2
12
-120/2

8 -60/2

0
0 4 8 12 16 20 24 28 32 Q [m³/h]
P2
[kW]
3.0
-290/2
2.5

2.0 -240/2

1.5 -190/2
-160/2
1.0
-180/2
0.5 -120/2
-60/2
0.0
0 4 8 12 16 20 24 28 32 Q [m³/h]
NPSH
[m]
10
-180/2
8

6 -60/2
-120/2
4

2
-160/2, -190/2, 240/2, -290/2
0
0 4 8 12 16 20 24 28 32 Q [m³/h]
Eta
[%]
75 -180/2
70
-290/2
65 -240/2
60 -190/2
55 -160/2
50 -60/2
45
40 -120/2
35
30
0 4 8 12 16 20 24 28 32 Q [m³/h]
TM02 5021 0504

0 2 4 6 8 10 Q [l/s]

0 1 2 3 4 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

62
Technical data DN 50
2-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 50 -60/2 -120/2 -180/2 -160/2 -190/2 -240/2 -290/2


TPD z z z z z z z
TPE z z z z z z z
TPED z z z z z z z
Series 200 200 200 300 300 300 300
1-phase TP 71 80 80 - - - -
3-phase TP 71 80 80 80 90 90 100
IEC size
1-phase TPE 71 80 80 80 - - -
3-phase TPE - 90 90 90 90 90 100
1-/3-phase TP★ [kW] 0.25/0.37 0.55/0.75 0.75/0.75 -/1.1 -/1.5 -/2.2 -/3
P2
1-/3-phase TPE [kW] 0.37/- 0.75/0.75 0.75/0.75 1.1/1.1 -/1.5 -/2.2 -/3
PN PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 50 50 50 50 50 50 50
1-/3-phase TP [mm] 141/141 141/141 141/141 -/178 -/178 -/178 -/198
AC
1-/3-phase TPE [mm] 141/- 141/178 141/178 178/178 -/178 -/178 -/198
1-/3-phase TP [mm] 133/109 133/109 133/109 -/110 -/110 -/110 -/120
AD
1-/3-phase TPE [mm] 140/- 140/167 140/167 140/167 -/167 -/167 -/177
AE 1-/3-phase TPE [mm] 105/- 105/132 105/132 105/132 -/132 -/132 -/132
AF 1-/3-phase TPE [mm] 105/- 105/132 105/132 105/132 -/132 -/132 -/132
P [mm] - - - 200 200 200 250
B1★★ [mm] 95/180 100/225 100/225 117/252 117/252 117/252 117/252

B2★★ [mm] 83/190 100/225 100/225 117/252 117/252 117/252 117/252


B3 [mm] 200 240 240 270 270 270 270
TP [mm] 133/180 133/225 133/225 117/252 117/252 117/252 125/260
B4★★ 1-phase TPE [mm] 140/264 140/225 140/225 140/252 - - -
3-phase TPE [mm] - 167/320 167/320 140/335 167/335 167/335 177/335
C1★★ [mm] 120/200 120/240 120/240 144/350 144/350 144/350 144/350
★★ [mm] 140/60 140/60 140/60 170/60 170/60 170/60 170/60
C5
C6 [mm] 125 126 126 175 175 175 175
L1 [mm] 280 280 280 340 340 340 340
H1 [mm] 75 75 75 115 115 115 115
H2 [mm] 137 135 135 152 152 152 180
1-/3-phase TP [mm] 403/403 441/441 441/441 -/548 -/548 -/588 -/630
H3
1-/3-phase TPE [mm] 403/- 442/491 441/491 498/548 -/548 -/588 -/630
H4 [mm] - - - - - - -
M M12 M12 M12 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

63
Performance curves DN 50
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 50-XX/2

H
[m]
-900/2 TP, TPE 50
90
50 Hz
-830/2
80
-710/2
70

60 -570/2

50
-440/2

40 -430/2

30 -360/2

20
0 10 20 30 40 50 60 70 Q [m³/h]
P2
[kW]
24
-900/2
20
-830/2
16 -710/2
12 -570/2
8 -440/2
-430/2
4 -360/2

0
0 10 20 30 40 50 60 70 Q [m³/h]
NPSH
[m]
14
12
10
8
6
4
2
0
0 10 20 30 40 50 60 70 Q [m³/h]
Eta
[%]
70 -430/2
65 -900/2
60
-360/2 -710/2 -830/2
55
50 -440/2 -570/2
45
40
35
30
0 10 20 30 40 50 60 70 Q [m³/h]
TM02 5022 0504

0 5 10 15 20 Q [l/s]

0 2 4 6 8 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

64
Technical data DN 50
2-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 50 -360/2 -430/2 -440/2 -570/2 -710/2 -830/2 -900/2


TPD z z z z z z z
TPE z z z z z z z
TPED z z z z z z z
Series 300 300 300 300 300 300 300
1-phase TP - - - - - - -
3-phase TP 112 132 132 160 160 160 180
IEC size
1-phase TPE - - - - - - -
3-phase TPE 112 132 132 160 160 160 180
1-/3-phase TP★ [kW] -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22
P2
1-/3-phase TPE [kW] -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 50 50 50 50 50 50 50
1-/3-phase TP [mm] -/220 -/220 -/220 -/260 -/320 -/320 -/363
AC
1-/3-phase TPE [mm] -/220 -/220 -/260 -/314 -/314 -/314 -/314
1-/3-phase TP [mm] -/134 -/134 -/134 -/172 -/197 -/197 -/258
AD
1-/3-phase TPE [mm] -/188 -/188 -/213 -/308 -/308 -/308 -/308
AE 1-/3-phase TPE [mm] -/145 -/145 -/145 -/210 -/210 -/210 -/210
AF 1-/3-phase TPE [mm] -/145 -/145 -/145 -/210 -/210 -/210 -/210
P [mm] 250 300 300 350 350 350 350
B1★★ [mm] 133/290 133/290 180/386 180/386 180/386 180/386 180/386

B2★★ [mm] 119/284 119/284 164/379 164/379 164/379 164/379 164/379


B3 [mm] 320 320 420 420 420 420 420
TP [mm] 134/290 150/310 180/386 180/386 197/386 197/386 258/392
B4★★ 1-phase TPE [mm] - - - - - - -
3-phase TPE [mm] 188/385 188/385 213/386 308/548 308/548 308/548 308/548
C1★★ [mm] 144/400 144/400 144/500 144/500 144/500 144/500 144/500
★★ [mm] 170/52 170/52 220/123 220/123 220/123 220/123 220/123
C5
C6 [mm] 175 175 175 175 175 175 175
L1 [mm] 340 340 440 440 440 440 440
H1 [mm] 115 115 115 115 115 115 115
H2 [mm] 189 228 234 264 264 264 264
1-/3-phase TP [mm] -/676 -/734 -/740 -/843 -/857 -/897 -/981
H3
1-/3-phase TPE [mm] -/676 -/734 -/728 -/850 -/850 -/894 -/920
H4 [mm] - - - 35 35 35 35
M M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

65
Performance curves DN 65
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 65-XX/2

H
[m]
26 -260/2
TP, TPE 65
24 50 Hz
-230/2
22
20
-190/2
18
16
-180/2
14
12
-120/2
10
8
6 -60/2
4
2
0
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
P2
[kW]
4.0 -260/2
3.5
3.0 -230/2
2.5
-190/2
2.0
1.5
-180/2
1.0 -120/2
0.5 -60/2
0.0
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
NPSH
[m]
5 -120/2

4
-180/2
3

2
-60/2
-190/2, -230/2, -260/2
1

0
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
Eta
[%]
80 -180/2
75
70
-260/2
65
60 -230/2
-190/2
55
50
45 -60/2
40 -120/2
35
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
TM02 5023 0504

0 2 4 6 8 10 12 14 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

66
Technical data DN 65
2-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 65 -60/2 -120/2 -180/2 -190/2 -230/2 -260/2


TPD z z z z z z
TPE z z z z z z
TPED z z z z z z
Series 200 200 200 300 300 300
1-phase TP 80 90 90 - - -
3-phase TP 71 90 90 90 100 112
IEC size
1-phase TPE 71 80 - - - -
3-phase TPE - 90 90 90 100 112
1-/3-phase TP★ [kW] 0.55/0.55 1.1/1.1 1.5/1.5 -/2.2 -/3 -/4
P2
1-/3-phase TPE [kW] 0.55/- 1.1/1.1 -/1.5 -/2.2 -/3 -/4
PN PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120]
D1 65 65 65 65 65 65
1-/3-phase TP [mm] 141/141 178/141 178/178 -/178 -/198 -/220
AC
1-/3-phase TPE [mm] 141/- 141/178 -/178 -/178 -/198 -/220
1-/3-phase TP [mm] 133/109 139/109 139/110 -/110 -/120 -/134
AD
1-/3-phase TPE [mm] 140/- 140/167 -/167 -/167 -/177 -/188
AE 1-/3-phase TPE [mm] 105/- 105/132 -/132 -/132 -/132 -/145
AF 1-/3-phase TPE [mm] 105/- 105/132 -/132 -/132 -/132 -/145
P [mm] - - - 200 250 250
B1★★ [mm] 93/195 100/225 100/225 142/298 142/298 142/298

B2★★ [mm] 93/210 100/225 100/225 124/290 124/290 124/290


B3 [mm] 240 240 240 320 320 320
TP [mm] 133/195 139/225 139/225 142/298 142/298 142/298
B4★★ 1-phase TPE [mm] 140/225 140/225 - - - -
3-phase TPE [mm] - 167/315 167/315 167/360 177/366 188/385
C1★★ [mm] 120/240 120/240 120/240 144/400 144/400 144/400
★★ [mm] 170/63 170/63 170/63 180/65 180/65 180/65
C5
C6 [mm] 153 153 153 175 175 175
L1 [mm] 340 340 340 360 360 360
H1 [mm] 82 82 82 105 105 105
H2 [mm] 145 144 154 172 201 201
1-/3-phase TP [mm] 468/418 517/512 557/507 -/598 -/641 -/678
H3
1-/3-phase TPE [mm] 418/- 462/512 -/517 -/598 -/641 -/678
H4 [mm] - - - - - -
M M12 M12 M12 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

67
Performance curves DN 65
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 65-XX/2

H
[m]

100
TP, TPE 65
-930/2 50 Hz
90

80
-720/2
70 -660/2

60 -550/2

50 -460/2
-410/2
40
-340/2
30

20
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
P2
[kW]
32 -930/2
28
24
-720/2
20 -660/2
16
-550/2
12 -460/2
8 -410/2
-340/2
4
0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
NPSH
[m]
10

0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
Eta
[%]
75
-410/2 -930/2
70 -340/2
65
-720/2
60 -550/2 -660/2
55 -460/2

50
45
40
35
30
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
TM02 5024 0504

0 5 10 15 20 25 Q [l/s]

0 2 4 6 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

68
Technical data DN 65
2-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 65 -340/2 -410/2 -460/2 -550/2 -660/2 -720/2 -930/2


TPD z z z z z z z
TPE z z z z z z -
TPED z z z z z z -
Series 300 300 300 300 300 300 300
1-phase TP - - - - - - -
3-phase TP 132 132 160 160 160 180 200
IEC size
1-phase TPE - - - - - - -
3-phase TPE 132 132 160 160 160 180 -
★ [kW] -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/30
1-/3-phase TP
P2
1-/3-phase TPE [kW] -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/-
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 65 65 65 65 65 65 65
1-/3-phase TP [mm] -/220 -/220 -/260 -/320 -/320 -/363 -/402
AC
1-/3-phase TPE [mm] -/220 -/260 -/314 -/314 -/314 -/314 -/-
1-/3-phase TP [mm] -/134 -/134 -/172 -/197 -/197 -/258 -/305
AD
1-/3-phase TPE [mm] -/188 -/213 -/308 -/308 -/308 -/308 -/-
AE 1-/3-phase TPE [mm] -/145 -/145 -/210 -/210 -/210 -/210 -
AF 1-/3-phase TPE [mm] -/145 -/145 -/210 -/210 -/210 -/210 -
P [mm] 300 300 350 350 350 350 400
B1★★ [mm] 142/298 142/298 178/349 178/349 178/349 178/349 178/349
★★ [mm] 124/290 124/290 164/383 164/383 164/383 164/383 164/383
B2
B3 [mm] 320 320 440 440 440 440 440
TP [mm] 150/310 150/310 178/395 197/395 197/395 258/402 305/421
B4★★ 1-phase TPE [mm] - - - - - - -
3-phase TPE [mm] 188/385 213/396 308/558 308/558 308/558 308/558 -
C1★★ [mm] 144/400 144/400 144/520 144/520 144/520 144/520 144/520
★★ [mm] 180/65 180/65 238/111 238/111 238/111 238/111 238/111
C5
C6 [mm] 175 175 175 175 175 175 175
L1 [mm] 360 360 475 475 475 475 475
H1 [mm] 105 105 125 125 125 125 125
H2 [mm] 239 239 263 263 263 263 263
1-/3-phase TP [mm] -/735 -/735 -/852 -/866 -/906 -/990 -/1046
H3
1-/3-phase TPE [mm] -/735 -/723 -/859 -/859 -/903 -/929 -/-
H4 [mm] - - 35 35 35 35 35
M M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

69
Performance curves DN 80
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 80-XX/2

H H
[m] [m]
24
-240/2 TP, TPE 80 70 -700/2 TP, TPE 80
50 Hz 65 50 Hz
22
-210/2 60
20 -570/2
55
18 -520/2
-180/2 50
16
45
14 -140/2 -400/2
40
12
-120/2 35 -330/2
10 30
-250/2
8 25
6 20
4 15
0 10 20 30 40 50 60 70 80 Q [m³/h] 0 20 40 60 80 100 120 140 Q [m³/h]
P2 P2
[kW] [kW]
6 32
-240/2 -700/2
28
5
24
-570/2
4 -210/2 20
-520/2
3 -180/2 16 -400/2
-140/2 12 -330/2
2
-120/2 8 -250/2
1 4
0 0
0 10 20 30 40 50 60 70 80 Q [m³/h] 0 20 40 60 80 100 120 140 Q [m³/h]
NPSH NPSH
[m] [m]
-520/2, 570/2, 700/2
10 10
-120/2
8 8
-250/2
6 6
-180/2, 210/2, 240/2
-140/2
4 4 -330/2, -400/2

2 2

0 0
0 10 20 30 40 50 60 70 80 Q [m³/h] 0 20 40 60 80 100 120 140 Q [m³/h]
Eta Eta
[%] [%]
80 -210/2 80
-700/2
75 75 -570/2
70 -240/2 70 -250/2 -330/2 -400/2
-180/2
65 65 -520/2
-140/2
60 60
55 55
-120/2
50 50
45 45
40 40
0 10 20 30 40 50 60 70 80 Q [m³/h] 0 20 40 60 80 100 120 140 Q [m³/h]
TM02 5025 0504

TM02 8750 0904

0 5 10 15 20 Q [l/s] 0 10 20 30 40 Q [l/s]

0 1 2 3 4 v [m/s] 0 2 4 6 8 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

70
Technical data DN 80
2-pole, PN 6, 10, 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 80 -120/2 -140/2 -180/2 -210/2 -240/2 -250/2 -330/2 -400/2 -520/2 -570/2 -700/2
TPD z z z z z z z z z z z
TPE z z z z z z z z z z -
TPED z z z z z z z z z z -
Series 200 300 300 300 300 300 300 300 300 300 300
1-phase TP 90 - - - - - - - - - -
3-phase TP 90 90 100 112 132 132 160 160 160 180 200
IEC size
1-phase TPE - - - - - - - - - - -
3-phase TPE 90 90 100 112 132 132 160 160 160 180 -
★ [kW] 1.1/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/30
1-/3-phase TP
P2
1-/3-phase TPE [kW] -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/-
PN PN 6/PN10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 80 80 80 80 80 80 80 80 80 80 80
1-/3-phase TP [mm] 178/178 -/178 -/198 -/220 -/220 -/220 -/260 -/320 -/320 -/363 -/402
AC
1-/3-phase TPE [mm] -/178 -/178 -/198 -/220 -/220 -/260 -/314 -/314 -/314 -/314 -/-
1-/3-phase TP [mm] 139/110 -/110 -/120 -/134 -/134 -/134 -/172 -/197 -/197 -/258 -/305
AD
1-/3-phase TPE [mm] -/167 -/167 -/177 -/188 -/188 -/213 -/308 -/308 -/308 -/308 -/-
AE 1-/3-phase TPE [mm] -/132 132 132 145 145 145 210 210 210 210 -
AF 1-/3-phase TPE [mm] -/132 132 132 145 145 145 210 210 210 210 -
P [mm] - 200 250 250 300 300 350 350 350 350 400
B1★★ [mm] 125/225 125/296 125/296 125/296 125/296 176/366 176/366 176/366 187/416 187/416 187/416
★★ [mm] 100/235 119/290 119/290 119/290 119/290 144/354 144/354 144/354 162/405 162/405 162/405
B2
B3 [mm] 240 340 340 340 340 400 400 400 470 470 470
TP [mm] 139/225 125/296 125/296 134/296 150/320 176/366 176/375 197/375 197/416 258/417 305/436
B4★★ 1-phase TPE [mm] - - - - - - - - - - -
3-phase TPE [mm] 167/320 167/296 177/296 188/395 188/395 213/366 308/538 308/538 308/573 308/573 -
C1★★ [mm] 160/240 144/420 144/420 144/420 144/420 144/480 144/480 144/480 144/550 144/550 144/550
★★ [mm] 180/53 180/78 180/78 180/78 180/78 220/93 220/93 220/93 250/133 250/133 250/133
C5
C6 [mm] 173 175 175 175 175 175 175 175 350 350 350
L1 [mm] 360 360 360 360 360 440 440 440 500 500 500
H1 [mm] 97 105 105 105 105 115 115 115 115 115 115
H2 [mm] 163 176 204 204 243 243 273 273 273 273 273
1-/3-phase TP [mm] 541/541 -/602 -/644 -/681 -/739 -/749 -/852 -/866 -/906 -/990 -/1047
H3
1-/3-phase TPE [mm] -/541 -/602 -/644 -/681 -/739 -/737 -/859 -/859 -/903 -/929 -/-
H4 [mm] - - - - - - 35 35 35 35 35
M M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

71
Performance curves DN 100
2-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 100-XX/2

H H
[m] [m]
26 -240/2 TP, TPE 100 60 TP, TPE 100
24 50 Hz -480/2 50 Hz
55
22 -200/2
50
20
18 45
-160/2
16 40 -390/2
-360/2
14 35
-310/2
12 -120/2 30
10 -250/2
25
8
20
6
4 15
2 10
0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h] 0 20 40 60 80 100 120 140 160 180200 Q [m³/h]
P2 P2
[kW] [kW]
8 -240/2 32
-480/2
7 28
6 24 -390/2
-200/2
5 20
-360/2
4 -160/2 16 -310/2
3 12 -250/2
2 -120/2 8
1 4
0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h] 0 20 40 60 80 100 120 140 160 180200 Q [m³/h]
NPSH NPSH
[m] [m]
14 -480/2
12 -120/2
12 360/2,-390/2
10
10
8
8
6 -250/2, -310/2
-160/2 -200/2, -240/2 6
4
4
2 2
0 0
0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h] 0 20 40 60 80 100 120 140 160 180200 Q [m³/h]
Eta Eta
[%] [%]
-480/2 -360/2
80 85
75 80
70 75
-200/2 -390/2
70 -310/2
65 -240/2
-160/2 65
60
60 -250/2
55 55
50 -120/2 50
45 45
40 40
0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h] 0 20 40 60 80 100 120 140 160 180200 Q [m³/h]
TM02 5026 0504

TM02 8751 0904

0 5 10 15 20 25 30 Q [l/s] 0 10 20 30 40 50 60 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 v [m/s] 0 1 2 3 4 5 6 7 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

72
Technical data DN 100
2-pole, PN 6, 10, 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 100 -120/2 -160/2 -200/2 -240/2 -250/2 -310/2 -360/2 -390/2 -480/2
TPD z z z z z z z z z
TPE z z z z z z z z -
TPED z z z z z z z z -
Series 200 300 300 300 300 300 300 300 300
1-phase TP - - - - - - - - -
3-phase TP 90 112 132 132 160 160 160 180 200
IEC size
1-phase TPE - - - - - - - - -
3-phase TPE 90 112 132 132 160 160 160 180 -
1-/3-phase TP★ [kW] -/2.2 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/30
P2
1-/3-phase TPE [kW] -/2.2 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/-
PN PN 6/PN 10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 100 100 100 100 100 100 100 100 100
1-/3-phase TP [mm] -/178 -/220 -/220 -/220 -/260 -/320 -/320 -/363 -/402
AC
1-/3-phase TPE [mm] -/178 -/220 -/220 -/260 -/314 -/314 -/314 -/314 -/-
1-/3-phase TP [mm] -/110 -/134 -/134 -/134 -/172 -/197 -/197 -/258 -/305
AD
1-/3-phase TPE [mm] -/167 -/188 -/188 -/213 -/308 -/308 -/308 -/308 -/-
AE 1-/3-phase TPE [mm] -/132 145 145 145 210 210 210 210 -
AF 1-/3-phase TPE [mm] -/132 145 145 145 210 210 210 210 -
P [mm] - 250 300 300 350 350 350 350 400
B1★★ [mm] 125/245 156/347 156/347 156/347 190/414 190/414 190/414 190/414 201/443
★★ [mm] 100/265 124/332 124/332 124/332 151/395 151/395 151/395 151/395 173/429
B2
B3 [mm] 280 470 470 470 500 500 500 500 500
TP [mm] 125/265 156/360 156/385 156/385 190/425 197/425 197/425 258/432 305/451
B4★★ 1-phase TPE [mm] - - - - - - - - -
3-phase TPE [mm] 167/340 188/347 188/350 213/350 308/414 308/414 308/414 308/414 -
C1★★ [mm] 160/280 144/480 144/480 144/480 230/550 230/550 230/550 230/550 230/550
★★ [mm] 225/83 250/104 250/104 250/104 275/110 275/110 275/110 275/110 275/110
C5
C6 [mm] 221 175 175 175 230 230 230 230 230
L1 [mm] 450 500 500 500 550 550 550 550 550
H1 [mm] 107 140 140 140 140 140 140 140 140
H2 [mm] 185 206 245 245 270 270 270 270 307
1-/3-phase TP [mm] -/613 -/718 -/776 -/776 -/874 -/888 -/928 -/1012 -/1106
H3
1-/3-phase TPE [mm] -/613 -/718 -/776 -/764 -/881 -/881 -/925 -/951 -/-
H4 [mm] - - - - 35 35 35 35 35
M M16 M16 M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

73
Performance curves DN 32
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16


TP, TPD, TPE, TPED 32-XXX/4

H H
[m] [m]
6.0
-60/4
TP, TPE 32 13 -120/4
TP, TPE 32
5.5 50 Hz 50 Hz
12
5.0
11
4.5
4.0 -40/4 10 -100/4

3.5 9
3.0 8 -80/4
2.5 -30/4
7
2.0
6
1.5
5
1.0
0.5 4
0.0 3
0 1 2 3 4 5 6 7 8 9Q [m³/h] 0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
P2 P2
[kW] [kW]
0.09 -60/4
0.6 -120/4
0.08
0.07 0.5
0.06 0.4
-40/4 -100/4
0.05
-30/4 0.3
0.04
-80/4
0.03 0.2
0.02
0.1
0.01
0.00 0.0
0 1 2 3 4 5 6 7 8 9Q [m³/h] 0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
NPSH NPSH
[m] -40/4, -60/4 [m]
3.5
5
3.0
4
2.5
-30/4
2.0 3
1.5
2
1.0
1
0.5
0.0 0
0 1 2 3 4 5 6 7 8 9Q [m³/h] 0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
Eta Eta
[%] [%]
70 55 -100/4
60 50
50 45
-120/4
40 40 -80/4
30 -40/4 35
-30/4
-60/4
20 30
10 25
0 20
0 1 2 3 4 5 6 7 8 9Q [m³/h] 0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
TM02 5027 0504

TM02 5028 0504

0.0 0.5 1.0 1.5 2.0 2.5 Q [l/s] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 v [m/s] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 v [m/s]
Note: All curves apply to single-head pumps. For further information, see page 50.

74
Technical data DN 32
4-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 32 -30/4 -40/4 -60/4 -80/4 -100/4 -120/4


TPD z z z z z z
TPE z z z z z z
TPED z z z z z z
Series 200 200 200 300 300 300
1-phase TP 63 71 71 - - -
3-phase TP 63 71 71 71 71 80
IEC size
1-phase TPE 71 71 71 71 71 80
3-phase TPE - - - - - 80
★ [kW] 0.12/0.12 0.18/0.25 0.18/0.25 -/0.25 -/0.37 -/0.55
1-/3-phase TP
P2
1-/3-phase TPE [kW] 0.37/- 0.37/- 0.37/- 0.25/- 0.37/- 0.55/0.55
PN PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120]
D1 [mm] 32 32 32 32 32 32
1-/3-phase TP [mm] 118/118 142/141 142/141 -/141 -/141 -/141
AC
1-/3-phase TPE [mm] 141/- 141/- 141/- 141/- 141/- 141/178
1-/3-phase TP [mm] 101/101 133/109 133/109 -/109 -/109 -/109
AD
1-/3-phase TPE [mm] 140/- 140/- 140/- 140/- 140/- 140/167
AE 1-/3-phase TPE [mm] 105/- 105/- 105/- 105/- 105/- 105/132
AF 1-/3-phase TPE [mm] 105/- 105/- 105/- 105/- 105/- 105/132
P [mm] - - - 170 170 200
B1★★ [mm] 75/180 102/222 102/222 125/260 125/260 144/321

B2★★ [mm] 75/180 102/222 102/222 117/257 117/257 144/321


B3 [mm] 200 240 240 276 276 355
TP [mm] 101/180 133/222 133/222 125/260 125/260 144/321
B4★★ 1-phase TPE [mm] 140/264 140/225 140/225 140/260 140/260 144/321
3-phase TPE [mm] - - - - - 167/321
C1★★ [mm] 80/200 80/240 80/240 144/356 144/356 144/435

C5★★ [mm] 110/52 140/82 140/82 170/45 170/45 220/46


C6 [mm] 103 103 103 175 175 175
L1 [mm] 220 280 280 340 340 440
H1 [mm] 68 79 79 100 100 100
H2 [mm] 142 125 125 129 129 156
1-/3-phase TP [mm] 416/390 395/395 395/395 -/420 -/420 -/487
H3
1-/3-phase TPE [mm] 408/- 395/- 395/- 420/- 420/- 487/537
H4 [mm] - - - - - -
M M12 M12 M12 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

75
Performance curves DN 40
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 40-XXX/4

H H
[m] [m] -160/4
TP, TPE 40 16 TP, TPE 40
7
-90/4 50 Hz 15 50 Hz
6 14
-60/4 13 -130/4
5 12
11
4
10 -100/4
3 9
-30/4 8
2 7
6
1
5
0 4
0 2 4 6 8 10 12 14 Q [m³/h] 0 2 4 6 8 10 12 14 16 18 Q [m³/h]
P2 P2
[kW] [kW]
0.24 1.2
-60/4 -160/4
0.20 1.0

0.16 0.8 -130/4


-90/4
0.12 0.6
-100/4
0.08 -30/4
0.4

0.04 0.2

0.00 0.0
0 2 4 6 8 10 12 14 Q [m³/h] 0 2 4 6 8 10 12 14 16 18 Q [m³/h]
NPSH NPSH
[m] [m]
3.5 -90/4 3.0
3.0
2.5
2.5
-60/4 2.0
2.0
1.5
1.5
1.0
1.0
-30/4
0.5 0.5

0.0 0.0
0 2 4 6 8 10 12 14 Q [m³/h] 0 2 4 6 8 10 12 14 16 18 Q [m³/h]
Eta Eta
[%] [%]
65 60
-100/4
60
55
55
-60/4 50
50 -160/4
45
45
-90/4 -130/4
40
40
35 35
-30/4
30 30
0 2 4 6 8 10 12 14 Q [m³/h] 0 2 4 6 8 10 12 14 16 18 Q [m³/h]
TM02 5029 0504

TM02 5030 0504

0 1 2 3 4 Q [l/s] 0 1 2 3 4 5 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 v [m/s] 0 1 2 3 4 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

76
Technical data DN 40
4-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 40 -30/4 -60/4 -90/4 -100/4 -130/4 -160/4


TPD z - z z z z
TPE z z z z z z
TPED z - z z z z
Series 200 200 200 300 300 300
1-phase TP 63 71 71 - - -
3-phase TP 63 71 71 80 80 90
IEC size
1-phase TPE 71 71 71 80 80 -
3-phase TPE - - - 90 90 90
1-/3-phase TP★ [kW] 0.12/0.12 0.25/0.25 0.18/0.25 -/0.55 -/0.75 -/1.1
P2
1-/3-phase TPE [kW] 0.37/- 0.37/- 0.37/- 0.55/0.55 0.75/0.75 -/1.1
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120]
D1 [mm] 40 40 40 40 40 40
1-/3-phase TP [mm] 118/118 141/141 141/141 -/141 -/141 -/178
AC
1-/3-phase TPE [mm] 141/- 141/- 141/- 141/178 141/178 -/178
1-/3-phase TP [mm] 101/101 133/109 133/109 -/109 -/109 -/110
AD
1-/3-phase TPE [mm] 140/- 140/- 140/- 140/167 140/167 -/167
AE 1-/3-phase TPE [mm] 164/- 105/- 105/- 105/132 105/132 132
AF 1-/3-phase TPE [mm] 164/- 105/- 105/- 105/132 105/132 132
P [mm] - - - 200 200 200
B1★★ [mm] 85/180 100/- 102/222 130/273 149/325 149/325
★★ [mm] 75/180 100/- 102/222 117/267 144/321 144/321
B2
B3 [mm] 200 - 240 290 355 355
TP [mm] 101/180 133/- 133/222 130/273 149/325 149/325
B4★★ 1-phase TPE [mm] 140/264 140/225 140/225 140/273 149/325 -
3-phase TPE [mm] - - - 167/277 167/325 167/325
C1★★ [mm] 120/200 120/- 120/240 144/400 144/435 144/435
★★ [mm] 125/45 125/- 160/95 170/45 220/108 220/108
C5
C6 [mm] 125 - 125 175 175 175
L1 [mm] 250 250 320 340 440 440
H1 [mm] 67 75 68 100 110 110
H2 [mm] 146 123 128 166 158 158
1-/3-phase TP [mm] 419/393 389/389 388/388 -/497 -/499 -/549
H3
1-/3-phase TPE [mm] 411/- 389/- 388/- 507/547 499/549 -/549
H4 [mm] - - - - - -
M M12 M12 M12 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

77
Performance curves DN 50
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 50-XXX/4

H H
[m] [m]
10 -110/4 TP, TPE 50 24 -230/4
TP, TPE 50
50 Hz 50 Hz
9 22
-90/4
8
20 -190/4
7
18
6
-60/4 16 -160/4
5
14
4 -130/4
12
3 -30/4
2 10

1 8

0 6
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h] 0 4 8 12 16 20 24 28 32 Q [m³/h]
P2 P2
[kW] [kW]
-110/4 3.2
0.7 -230/4
0.6 2.8
-90/4 2.4
0.5 -190/4
2.0
0.4
-60/4 1.6 -160/4
0.3
1.2 -130/4
0.2 0.8
0.1 -30/4 0.4
0.0 0.0
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h] 0 4 8 12 16 20 24 28 32 Q [m³/h]
NPSH NPSH
[m] [m]
3.5 3.5
3.0 -60/4 3.0
2.5 2.5
2.0 2.0
1.5 1.5
-30/4
1.0 1.0
-90/4, -110/4
0.5 0.5
0.0 0.0
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h] 0 4 8 12 16 20 24 28 32 Q [m³/h]
Eta Eta
[%] [%]
70 65
65 60
60 -230/4
55
55 -190/4
-90/4 -60/4 -130/4
50 -160/4
50
-110/4 45
45
40 -30/4 40
35 35
30 30
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h] 0 4 8 12 16 20 24 28 32 Q [m³/h]
TM02 5031 0504

TM02 5032 0504

0 1 2 3 4 5 6 Q [l/s] 0 2 4 6 8 10 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0v [m/s] 0 1 2 3 4 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

78
Technical data DN 50
4-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 50 -30/4 -60/4 -90/4 -110/4 -130/4 -160/4 -190/4 -230/4


TPD z z z z z z z z
TPE z z z z z z z z
TPED z z z z z z z z
Series 200 200 300 300 300 300 300 300
1-phase TP 71 80 - - - - - -
3-phase TP 71 71 80 80 90 90 100 100
IEC size
1-phase TPE 71 71 80 80 - - - -
3-phase TPE - - 90 90 90 90 90 90
1-/3-phase TP★ [kW] 0.18/0.25 0.37/0.37 -/0.55 -/0.75 -/1.1 -/1.5 -/2.2 -/3
P2
1-/3-phase TPE [kW] 0.37/- 0.37/- 0.55/0.55 0.75/0.75 -/1.1 -/1.5 -/2.2 -/3
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 50 50 50 50 50 50 50 50
1-/3-phase TP [mm] 141/141 141/141 -/141 -/141 -/178 -/178 -/198 -/198
AC
1-/3-phase TPE [mm] 141/- 141/- 141/178 141/178 -/178 -/178 -/198 -/198
1-/3-phase TP [mm] 133/109 133/109 -/109 -/109 -/110 -/110 -/120 -/120
AD
1-/3-phase TPE [mm] 140/- 140/- 140/167 140/167 -/167 -/167 -/177 -/177
AE 1-/3-phase TPE [mm] 105/- 105/- 105/132 105/132 -/132 -/132 -/132 -/132
AF 1-/3-phase TPE [mm] 105/- 105/- 105/132 105/132 -/132 -/132 -/132 -/132
P [mm] - - 200 200 200 200 250 250
B1★★ [mm] 90/181 110/225 133/290 180/386 180/386 180/386 180/386 180/386

B2★★ [mm] 75/186 100/225 119/284 164/379 164/379 164/379 164/379 164/379
B3 [mm] 200 240 320 420 420 420 420 420
TP [mm] 133/181 133/225 133/290 180/386 180/386 180/386 180/386 180/386
B4★★ 1-phase TPE [mm] 140/264 140/225 140/290 180/386 - - - -
3-phase TPE [mm] - - 167/290 180/386 180/386 180/386 180/386 180/386
C1★★ [mm] 120/200 120/240 144/400 144/500 144/500 144/500 144/500 144/500
★★ [mm] 140/60 140/60 170/52 220/123 220/123 220/123 220/123 220/123
C5
C6 [mm] 125 125 175 175 175 175 175 175
L1 [mm] 280 280 340 440 440 440 440 440
H1 [mm] 82 82 115 115 115 115 115 115
H2 [mm] 135 127 161 167 167 167 195 195
1-/3-phase TP [mm] 408/408 452/400 -/507 -/513 -/563 -/603 -/645 -/645
H3
1-/3-phase TPE [mm] 408/- 400/- 507/557 513/563 -/563 -/603 -/645 -/645
H4 [mm] - - - - - - - -
M M12 M12 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

79
Performance curves DN 65
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 65-XXX/4

H H
[m] [m]
11
-110/4
TP, TPE 65 24
-240/4
TP, TPE 65
10 50 Hz 50 Hz
-90/4
22
9
20
8
7 18
-170/4
6 -60/4 16 -150/4
5 14
4 -130/4
12
3 -30/4
10
2
1 8

0 6
0 4 8 12 16 20 24 28 32 36 Q [m³/h] 0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
P2 P2
[kW] [kW]
1.2 4.0 -240/4
-110/4
3.5
1.0
3.0
0.8 2.5
-90/4 -170/4
0.6 2.0 -150/4
-60/4 1.5 -130/4
0.4
1.0
0.2 0.5
-30/4
0.0 0.0
0 4 8 12 16 20 24 28 32 36 Q [m³/h] 0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
NPSH NPSH
[m] [m]
2.5 -30/4 -60/4 2.5

2.0 2.0

1.5 1.5

1.0 1.0
-90/4, -110/4
0.5 0.5

0.0 0.0
0 4 8 12 16 20 24 28 32 36 Q [m³/h] 0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
Eta Eta
[%] [%]
75 70
-90/4 -240/4
70 65
65 -170/4
-110/4 60 -130/4
60 -60/4 -150/4
55
55
50
50
45 -30/4 45
40 40
35 35
0 4 8 12 16 20 24 28 32 36 Q [m³/h] 0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
TM02 5033 0504

TM02 5043 0504

0 2 4 6 8 10 Q [l/s] 0 2 4 6 8 10 12 14 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0v [m/s] 0 1 2 3 4 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

80
Technical data DN 65
4-pole, PN 6, 10, 16

B4 B4 B4 B4
AD P AC P
AD AC B3 AD

H3
Rp 1/4

H2
H2

H1

TM02 8632 5004 - TM02 8631 5004


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 65 -30/4 -60/4 -90/4 -110/4 -130/4 -150/4 -170/4 -240/4


TPD z z z z z z z z
TPE z z z z z z z z
TPED z z z z z z z z
Series 200 200 300 300 300 300 300 300
1-phase TP 71 80 - - - - - -
3-phase TP 71 80 80 90 90 100 100 112
IEC size
1-phase TPE 71 80 80 - - - - -
3-phase TPE - 90 90 90 90 100 100 112
1-/3-phase TP★ [kW] 0.25/0.25 0.55/0.55 -/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4
P2
1-/3-phase TPE [kW] 0.37/- 0.55/0.55 0.75/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 65 65 65 65 65 65 65 65
1-/3-phase TP [mm] 141/141 141/141 -/141 -/178 -/178 -/198 -/198 -/220
AC
1-/3-phase TPE [mm] 141/- 141/178 141/178 -/178 -/178 -/198 -/198 -/220
1-/3-phase TP [mm] 133/109 133/109 -/109 -/110 -/110 -/120 -/120 -/134
AD
1-/3-phase TPE [mm] 140/- 140/167 140/167 -/167 -/167 -/177 -/177 -/188
AE 1-/3-phase TPE [mm] 105/- 105/132 105/200 132 132 -/132 132 145
AF 1-/3-phase TPE [mm] 105/- 105/132 105/200 132 132 -/132 132 145
P [mm] - - 200 200 200 250 250 250
B1★★ [mm] 125/230 125/230 142/298 178/349 178/349 178/349 178/349 178/349
★★ [mm] 100/240 100/240 124/290 164/383 164/383 164/0 164/383 164/383
B2
B3 [mm] 240 240 320 440 440 440 440 440
TP [mm] 133/240 133/240 142/298 178/383 178/383 178/349 178/383 178/383
B4★★ 1-phase TPE [mm] 140/240 140/240 142/298 - - - - -
3-phase TPE [mm] - 167/252 167/360 178/383 178/383 178/383 178/383 188/365
C1★★ [mm] 160/240 160/240 144/400 144/520 144/520 144/520 144/520 144/520
★★ [mm] 170/63 170/63 180/65 238/111 238/111 238/111 238/111 238/111
C5
C6 [mm] 153 153 175 175 175 175 175 175
L1 [mm] 340 340 360 475 475 475 475 475
H1 [mm] 97 97 105 125 125 125 125 125
H2 [mm] 135 147 172 166 166 194 194 194
1-/3-phase TP [mm] 423/423 475/475 -/508 -/572 -/612 -/654 -/654 -/691
H3
1-/3-phase TPE [mm] 423/- 475/525 508/558 -/572 -/612 -/654 -/654 -/691
H4 [mm] - - - - - - - -
M M16 M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

81
Performance curves DN 80
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 80-XXX/4

H H
[m] [m]
11 -110/4
TP, TPE 80 34 -340/4 TP, TPE 80
10 50 Hz 32 50 Hz
9 -90/4 30

8 28
-270/4
-70/4 26
7
-60/4 24
6 -240/4
22
5
20
4
18 -170/4
3 -30/4
16
-150/4
2
14
1
12
0 10
0 10 20 30 40 50 60 70 Q [m³/h] 0 10 20 30 40 50 60 70 80 90 100 110
Q [m³/h]
P2 P2
[kW]
[kW]
2.0 -110/4
12 -340/4

1.6 10
-90/4

1.2 8 -270/4
-70/4
6 -240/4
0.8 -60/4
4 -170/4
0.4 -150/4
-30/4 2
0.0
0
0 10 20 30 40 50 60 70 Q [m³/h]
NPSH 0 10 20 30 40 50 60 70 80 90 100 110
Q [m³/h]
[m] NPSH
[m]
5
-30/4 5
4 -270/4, 340/4
4
3
-60/4 90/4, -110/4 3
-240/4
2
2
1
-70/4 1 -150/4, 170/4
0
0
0 10 20 30 40 50 60 70 Q [m³/h]
Eta 0 10 20 30 40 50 60 70 80 90 100 110
Q [m³/h]
[%] -90/4
Eta
80 [%]
-170/4
75 75
-150/4
70 -110/4 70 -340/4
-70/4
65 65 -240/4 -270/4
60 60
55
-60/4 55
50
-30/4 50
45
45
40
0 10 20 30 40 50 60 70 Q [m³/h] 40
0 10 20 30 40 50 60 70 80 90 100 110
Q [m³/h]
TM02 5044 0504

TM02 8752 3208

0 4 8 12 16 20 Q [l/s]
0 4 8 12 16 20 24 28 32
Q [l/s]
0 1 2 3 4 v [m/s]
0 1 2 3 4 5 6 [ / ]
Note: All curves apply to single-head pumps. For further information, see page 50.

82
Technical data DN 80
4-pole, PN 6, 10, 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 80 -30/4 -60/4 -70/4 -90/4 -110/4 -150/4 -170/4 -240/4 -270/4 -340/4
TPD z z z z z z z z z z
TPE z z z z z z z z z z
TPED z z z z z z z z z z
Series 200 200 300 300 300 300 300 300 300 300
1-phase TP 80 90 - - - - - - - -
3-phase TP 71 80 90 90 100 100 112 132 132 160
IEC size
1-phase TPE 71 80 - - - - - - - -
3-phase TPE - 90 90 90 100 112 112 132 132 160
1-/3-phase TP★ [kW] 0.37/0.37 0.75/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11
P2
1-/3-phase TPE [kW] 0.37/- 0.75/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11
PN PN 6/PN 10 PN 6/PN 10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 80 80 80 80 80 80 80 80 80 80
1-/3-phase TP [mm] 142/141 178/141 -/178 -/178 -/198 -/198 -/220 -/267 -/267 -/320
AC
1-/3-phase TPE [mm] 141/- 141/178 -/178 -/178 -/198 -/198 -/220 -/260 -/260 -/314
1-/3-phase TP [mm] 133/109 139/109 -/110 -/110 -/120 -/120 -/134 -/167 -/167 -/197
AD
1-/3-phase TPE [mm] 140/- 140/167 -/167 -/167 -/177 -/177 -/188 -/213 -/213 -/308
AE 1-/3-phase TPE [mm] 105/- 105/132 132 132 132 132 145 145 145 210
AF 1-/3-phase TPE [mm] 105/- 105/132 132 132 132 132 145 145 145 210
P [mm] - - 200 200 250 250 250 300 300 350
B1★★ [mm] 130/230 135/240 176/366 176/366 176/366 187/416 187/416 243/491 243/491 243/491
★★ [mm] 100/240 100/250 144/354 144/354 144/354 162/405 162/405 226/480 226/480 226/480
B2
B3 [mm] 240 240 400 400 400 470 470 500 500 500
TP [mm] 133/230 139/240 176/366 176/366 176/366 187/416 187/416 243/491 243/491 243/491
B4★★ 1-phase TPE [mm] 140/240 140/250 - - - - - - - -
3-phase TPE [mm] - 167/320 176/366 176/366 177/366 187/416 188/416 243/491 243/491 308/491
C1★★ [mm] 160/240 160/240 144/480 144/480 144/480 144/550 144/550 230/550 230/550 230/550
★★ [mm] 180/53 180/53 220/93 220/93 220/93 250/133 250/133 310/105 310/105 310/105
C5
C6 [mm] 173 173 175 175 175 175 175 350 350 350
L1 [mm] 360 360 440 440 440 500 500 620 620 620
H1 [mm] 107 107 115 115 115 115 115 140 140 140
H2 [mm] 163 153 176 176 204 204 204 273 273 303
1-/3-phase TP [mm] 513/461 551/491 -/572 -/612 -/654 -/654 -/691 -/786 -/824 -/921
H3
1-/3-phase TPE [mm] 461/- 491/541 -/572 -/612 -/654 -/654 -/691 -/792 -/872 -/914
H4 [mm] - - - - - - - - - 35
M M16 M16 M16 M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

83
Performance curves DN 100
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 100-XXX/4

H
[m]
20 TP, TPE 100
50 Hz
18 -170/4
16
14 -130/4

12
-110/4
10
-90/4
8
-70/4
6 -60/4
4 -30/4

2
0
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
P2
[kW]
6 -170/4
5

4 -130/4
-110/4
3
-90/4
2
-70/4
1 -60/4
-30/4
0
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
NPSH
[m]
10 -30/4

8
-130/4, -170/4
6
-60/4
4
-90/4, -110/4

2
-70/4
0
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
Eta
[%] -170/4
80
75
-110/4
70 -90/4
65 -70/4 -130/4
-30/4
60
-60/4
55
50
45
40
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
TM02 5045 0504

0 5 10 15 20 25 30 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

84
Technical data DN 100
4-pole, PN 6, 10, 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 100 -30/4 -60/4 -70/4 -90/4 -110/4 -130/4 -170/4


TPD z z z z z z z
TPE z z z z z z z
TPED z z z z z z z
Series 200 200 300 300 300 300 300
1-phase TP 80 90 - - - - -
3-phase TP 80 90 90 100 100 112 132
IEC size
1-phase TPE 80 - - - - - -
3-phase TPE 90 90 90 100 112 112 132
1-/3-phase TP★ [kW] 0.55/0.55 1.1/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5
P2
1-/3-phase TPE [kW] 0.55/0.55 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5
PN PN 6/PN 10 PN 6/PN 10 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 100 100 100 100 100 100 100
1-/3-phase TP [mm] 141/141 178/178 -/178 -/198 -/198 -/220 -/267
AC
1-/3-phase TPE [mm] 141/178 -/178 -/178 -/198 -/198 -/220 -/260
1-/3-phase TP [mm] 133/109 139/110 -/110 -/120 -/120 -/134 -/167
AD
1-/3-phase TPE [mm] 140/167 -/167 -/167 -/177 -/177 -/188 -/213
AE 1-/3-phase TPE [mm] 105/132 -/132 132 132 132 145 145
AF 1-/3-phase TPE [mm] 105/132 -/132 132 132 132 145 145
P [mm] - - 200 200 200 250 300
B1★★ [mm] 175/280 175/280 190/414 190/414 190/414 201/443 201/443
★★ [mm] 125/305 125/305 151/395 151/395 151/395 173/429 173/429
B2
B3 [mm] 280 280 470 470 470 500 500
TP [mm] 175/280 175/280 190/414 190/414 190/414 201/443 201/443
B4★★ 1-phase TPE [mm] 175/305 - - - - - -
3-phase TPE [mm] 175/340 175/340 190/414 190/414 190/414 201/443 213/443
C1★★ [mm] 200/280 200/280 230/550 230/550 230/550 230/550 230/550
★★ [mm] 225/83 225/83 250/110 275/110 275/110 275/110 275/110
C5
C6 [mm] 221 221 230 230 230 230 230
L1 [mm] 450 450 500 550 550 550 550
H1 [mm] 122 122 140 140 140 140 140
H2 [mm] 172 182 173 201 201 261 277
1-/3-phase TP [mm] 525/525 625/585 -/634 -/676 -/676 -/773 -/790
H3
1-/3-phase TPE [mm] 525/575 -/585 -/634 -/676 -/676 -/773 -/796
H4 [mm] - - - - - - -
M M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

85
Performance curves DN 100
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 100-XXX/4

H
[m]
TP, TPE 100
40
-410/4 50 Hz
36 -370/4

32
-330/4

28
-250/4
24

20 -200/4

16

12
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
P2
[kW]
24 -410/4
20
-370/4
16 -330/4
12 -250/4
8 -200/4

0
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
NPSH
[m]
10
-330/4, -370/4, -410/4
8

4
-200/4, -250/4
2

0
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
Eta
[%]
80
-410/4
75
70 -330/4
-200/4
65 -250/4 -370/4
60
55
50
45
40
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
TM02 8753 0904

0 10 20 30 40 50 Q [l/s]

0 1 2 3 4 5 6 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

86
Technical data DN 100
4-pole, PN 6, 10, 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 100 -200/4 -250/4 -330/4 -370/4 -410/4


TPD z z z z z
TPE z z z z -
TPED z z z z -
Series 300 300 300 300 300
1-phase TP - - - - -
3-phase TP 132 160 160 180 180
IEC size
1-phase TPE - - - - -
3-phase TPE 132 160 160 180 -
1-/3-phase TP★ [kW] -/7.5 -/11 -/15 -/18.5 -/22
P2
1-/3-phase TPE [kW] -/7.5 -/11 -/15 -/18.5 -
PN PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 100 100 100 100 100
1-/3-phase TP [mm] -/267 -/320 -/320 -/363 -/363
AC
1-/3-phase TPE [mm] -/260 -/314 -/314 -/314 -
1-/3-phase TP [mm] -/167 -/197 -/197 -/258 -/258
AD
1-/3-phase TPE [mm] -/213 -/308 -/308 -/308 -
AE 1-/3-phase TPE [mm] 145 210 210 210 -
AF 1-/3-phase TPE [mm] 145 210 210 210 -
P [mm] 300 350 350 350 350
B1★★ [mm] 290/579 290/579 290/579 290/579 290/579
★★ [mm] 249/561 249/561 249/561 249/561 249/561
B2
B3 [mm] 600 600 600 600 600
TP [mm] 290/579 290/579 290/579 290/579 290/579
B4★★ 1-phase TPE [mm] - - - - -
3-phase TPE [mm] 290/579 308/579 308/579 308/579 -
C1★★ [mm] 230/680 230/680 230/680 230/680 230/680
★★ [mm] 335/110 335/110 335/110 335/110 335/110
C5
C6 [mm] 350 350 350 350 350
L1 [mm] 670 670 670 670 670
H1 [mm] 175 175 175 175 175
H2 [mm] 254 308 308 308 308
1-/3-phase TP [mm] -/840 -/961 -/1001 -/1085 -/1085
H3
1-/3-phase TPE [mm] -/888 -/954 -/998 -/1024 -
H4 [mm] - 35 35 35 35
M M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

87
Performance curves DN 125
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 125-XXX/4

H H
[m] [m]
15 TP, TPE 125 -420/4 TP, TPE 125
-160/4 40
50 Hz 50 Hz
14
13 36 -360/4

-130/4
12 32 -320/4

11
-110/4 28
10 -250/4

9 24
-210/4
8 20
7
16
6
5 12
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 40 80 120 160 200 Q [m³/h]
P2 P2
[kW] [kW]
-420/4
8 -160/4 28
7
24
6 -360/4
-130/4 20
5 -320/4
16
4 -110/4
-250/4
12
3 -210/4

2 8

1 4
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 40 80 120 160 200 Q [m³/h]
NPSH NPSH
[m] [m]
6 -320/4, -360/4, -420/4
5
5
4
4
3 -210/4, -250/4
-110/4, -130/4, 160/4 3
2
2
1 1

0 0
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 40 80 120 160 200 Q [m³/h]
Eta Eta
[%] [%] -360/4
80 75
-160/4
75 70
70 -130/4 -320/4
-110/4 65 -210/4 -420/4
65 -250/4
60
60
55
55
50 50
45 45
40 40
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 40 80 120 160 200 Q [m³/h]
TM02 8755 0904

TM02 8756 0904

0 10 20 30 40 50 Q [l/s] 0 10 20 30 40 50 60 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 v [m/s] 0 1 2 3 4 5v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

88
Technical data DN 125
4-pole, PN 6, 10, 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 125 -110/4 -130/4 -160/4 -210/4 -250/4 -320/4 -360/4 -420/4


TPD z z z z z z z z
TPE z z z z z z - -
TPED z z z z z z - -
Series 300 300 300 300 300 300 300 300
1-phase TP - - - - - - - -
3-phase TP 112 132 132 160 160 180 180 200
IEC size
1-phase TPE - - - - - - - -
3-phase TPE 112 132 132 160 160 180 - -
★ [kW] -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/30
1-/3-phase TP
P2
1-/3-phase TPE [kW] -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 - -/-
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 125 125 125 125 125 125 125 125
1-/3-phase TP [mm] -/220 -/267 -/267 -/320 -/320 -/363 -/363 -/402
AC
1-/3-phase TPE [mm] -/220 -/260 -/260 -/314 -/314 -/314 - -/-
1-/3-phase TP [mm] -/134 -/167 -/167 -/197 -/197 -/258 -/258 -/305
AD
1-/3-phase TPE [mm] -/188 -/213 -/213 -/308 -/308 -/308 - -/-
AE 1-/3-phase TPE [mm] 145 145 145 210 210 210 - -
AF 1-/3-phase TPE [mm] 145 145 145 210 210 210 - -
P [mm] 250 300 300 350 350 350 350 400
B1★★ [mm] 250/537 250/537 250/537 271/566 271/566 271/566 271/566 271/566
★★ [mm] 202/518 202/518 202/518 243/552 243/552 243/552 243/552 243/552
B2
B3 [mm] 600 600 600 600 600 600 600 600
TP [mm] 250/537 250/537 250/537 271/566 271/566 271/566 271/566 305/566
B4★★ 1-phase TPE [mm] - - - - - - - -
3-phase TPE [mm] 250/537 250/537 250/537 308/566 308/566 308/566 - -
C1★★ [mm] 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680
★★ [mm] 310/84 310/84 310/84 400/175 400/175 400/175 400/175 400/175
C5
C6 [mm] 300 300 300 350 350 350 350 350
L1 [mm] 620 620 620 800 800 800 800 800
H1 [mm] 215 215 215 215 215 215 215 215
H2 [mm] 267 283 283 318 318 318 318 318
1-/3-phase TP [mm] -/854 -/870 -/908 -/1011 -/1051 -/1135 -/1135 -/1192
H3
1-/3-phase TPE [mm] -/854 -/877 -/969 -/1004 -/1048 -/1074 -/- -/-
H4 [mm] - - - 35 35 35 35 35
M M16 M16 M16 M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

89
Performance curves DN 150
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 150-XXX/4

H
[m]
24 -250/4 TP, TPE 150
50 Hz
22 -220/4
20
-200/4
18

16 -160/4

14
-130/4
12

10

6
0 40 80 120 160 200 240 280 320 Q [m³/h]
P2
[kW]
24
-250/4
20
-220/4
16 -200/4
12 -160/4
8 -130/4

0
0 40 80 120 160 200 240 280 320 Q [m³/h]
NPSH
[m]
6
-130/4, -160/4, -200/4, -220/4, -250/4

1
0 40 80 120 160 200 240 280 320 Q [m³/h]
Eta
[%]
85
80 -250/4
75
-160/4 -200/4
70 -220/4
-130/4
65
60
55
50
45
0 40 80 120 160 200 240 280 320 Q [m³/h]
TM02 8754 0904

0 20 40 60 80 100 Q [l/s]

0 1 2 3 4 5 v [m/s]

Note: All curves apply to single-head pumps. For further information, see page 50.

90
Technical data DN 150
4-pole, PN 6, 10, 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 150 -130/4 -160/4 -200/4 -220/4 -250/4


TPD z z z z z
TPE z z z z -
TPED z z z z -
Series 300 300 300 300 300
1-phase TP - - - - -
3-phase TP 132 160 160 180 180
IEC size
1-phase TPE - - - - -
3-phase TPE 132 160 160 180 -
1-/3-phase TP★ [kW] -/7.5 -/11 -/15 -/18.5 -/22
P2
1-/3-phase TPE [kW] -/7.5 -/11 -/15 -/18.5 -
PN PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 150 150 150 150 150
1-/3-phase TP [mm] -/267 -/320 -/320 -/363 -/363
AC
1-/3-phase TPE [mm] -/260 -/314 -/314 -/314 -
1-/3-phase TP [mm] -/167 -/197 -/197 -/258 -/258
AD
1-/3-phase TPE [mm] -/213 -/308 -/308 -/308 -
AE 1-/3-phase TPE [mm] 145 210 210 210 -
AF 1-/3-phase TPE [mm] 145 210 210 210 -
P [mm] 300 350 350 350 350
B1★★ [mm] 296/583 296/583 296/583 296/583 296/583
★★ [mm] 237/553 237/553 237/553 237/553 237/553
B2
B3 [mm] 600 600 600 600 600
TP [mm] 296/583 296/583 296/583 296/583 296/583
B4★★ 1-phase TPE [mm] - - - - -
3-phase TPE [mm] 296/583 308/583 308/583 308/583 -
C1★★ [mm] 230/680 230/680 230/680 230/680 230/680
★★ [mm] 400/153 400/153 400/153 400/153 400/153
C5
C6 [mm] 350 350 350 350 350
L1 [mm] 800 800 800 800 800
H1 [mm] 215 215 215 215 215
H2 [mm] 291 321 321 321 321
1-/3-phase TP [mm] -/917 -/1015 -/1055 -/1139 -/1139
H3
1-/3-phase TPE [mm] -/966 -/1008 -/1052 -/1078 -/-
H4 [mm] - 35 35 35 35
M M16 M16 M16 M16 M16

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

91
Performance curves DN 150
4-pole, PN 6, 10, 16

TP, TPD, TPE, TPED 150-XXX/4

H
[m]
40 -390/4 TP, TPE 150
38 50 Hz
36
-340/4
34
32
30
-280/4
28
26 -260/4
24
22
20
18
16
14
0 40 80 120 160 200 240 280 320 Q [m³/h]
P2
[kW]
40 -390/4
35
30 -340/4
25
-280/4
20
-260/4
15
10
5
0 40 80 120 160 200 240 280 320 Q [m³/h]
NPSH
[m]
-260/4
10

4
-280/4, -340/4, 390/4
2

0
0 40 80 120 160 200 240 280 320 Q [m³/h]
Eta
[%]
85
80 -390/4
75 -260/4
70 -280/4 -340/4
65
60
55
50
45
0 40 80 120 160 200 240 280 320 Q [m³/h]
TM03 4548 2406

0 20 40 60 80 100 Q [l/s]

0 1 2 3 4 5 v [m/s]
Note: All curves apply to single-head pumps. For further information, see page 50.

92
Technical data DN 150
4-pole, PN 6, 10, 16

TM03 8623 4008


Technical data

TP 150 -260/4 -280/4 -340/4 -390/4


TPD - - - -
TPE z - - -
TPED - - - -
Series 300 300 300 300
1-phase TP - - - -
3-phase TP 180 180 200 225
IEC size
1-phase TPE - - - -
3-phase TPE 180 - - -
1-/3-phase TP★ [kW] -/18.5 -/22 -/30 -/37
P2
1-/3-phase TPE [kW] -/18.5 -/- -/- -/-
PN PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 150 150 150 150
1-/3-phase TP [mm] -/363 -/363 -/402 -/442
AC
1-/3-phase TPE [mm] -/314 -/ - -/- -/-
1-/3-phase TP [mm] -/258 -/258 -/305 -/325
AD
1-/3-phase TPE [mm] -/308 -/ - -/- -/-
AE 1-/3-phase TPE [mm] 210 - - -
AF 1-/3-phase TPE [mm] 210 - - -
P [mm] 350 350 400 450
B1★★ [mm] 335/- 335/- 335/- 335/-

B2★★ [mm] 288/- 288/- 288/- 288/-


TP [mm] 335/- 335/- 335/- 335/-
B4★★ 1-phase TPE [mm] - - - -
3-phase TPE [mm] 335/- -/- -/- -/-
L1 [mm] 800 800 800 800
H1 [mm] 235 235 235 235
H2 [mm] 319 319 319 349
1-/3-phase TP [mm] -/1156 -/1156 -/1212 -/1233
H3
1-/3-phase TPE [mm] -/1095 -/ - -/- -/-

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

93
Performance curves DN 200
4-pole, PN 6, 10, 16

TP 200-XXX/4

H
[m]
44 TP, TPE 200
-410/4
50 Hz
40

36
-320/4
32
-270/4
28
-250/4
24 -220/4

20 -180/4

16

12

8
0 100 200 300 400 500 600 700 Q [m³/h]
P2
[kW]
80 -410/4
70
60
-320/4
50
-270/4
40 -250/4
30 -220/4

20 -180/4

10
0 100 200 300 400 500 600 700 Q [m³/h]
NPSH
[m]
10

8
-180/4, -220/4, -250/4
6
-270/4, 320/4, -410/4
4

0
0 100 200 300 400 500 600 700 Q [m³/h]
Eta
[%]
85
-410/4
80
75
-320/4
70 -180/4 -270/4
-220/4
-250/4
65
60
55
50
45
0 100 200 300 400 500 600 700 Q [m³/h]
TM03 4650 2406

0 50 100 150 200 Q [l/s]

0 1 2 3 4 5 6 v [m/s]

94
Technical data DN 200
4-pole, PN 6, 10, 16

TM03 8621 4008


Technical data

TP 200 -180/4 -220/4 -250/4 -270/4 -320/4 -410/4


TPD - - - - - -
TPE - - - - - -
TPED - - - - - -
Series 300 300 300 300 300 300
1-phase TP - - - - - -
3-phase TP 180 200 225 225 250 280
IEC size
1-phase TPE - - - - - -
3-phase TPE - - - - - -
★ [kW] -/22 -/30 -/37 -/45 -/55 -/75
1-/3-phase TP
P2
1-/3-phase TPE [kW] -/- -/- -/- -/- -/- -/-
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 200 200 200 200 200 200
1-/3-phase TP [mm] -/363 -/402 -/442 -/442 -/495 -/555
AC
1-/3-phase TPE [mm] -/ - -/- -/- -/- -/- -/-
1-/3-phase TP [mm] -/258 -/305 -/325 -/325 -/392 -/432
AD
1-/3-phase TPE [mm] -/ - -/- -/- -/- -/- -/-
AE 1-/3-phase TPE [mm] - - - - - -
AF 1-/3-phase TPE [mm] - - - - - -
P [mm] 350 400 450 450 550 550
B1★★ [mm] 393/- 393/- 393/- 393/- 393/- 393/-
★★ [mm] 328/- 328/- 328/- 328/- 328/- 328/-
B2
TP [mm] 393/- 393/- 393/- 393/- 393/- 432/-
B4★★ 1-phase TPE [mm] - - - - - -
3-phase TPE [mm] -/- -/- -/- -/- -/- -/-
L1 [mm] 900 900 900 900 900 900
H1 [mm] 295 295 295 295 295 295
H2 [mm] 347 347 377 377 377 377
1-/3-phase TP [mm] -/1244 -/1300 -/1321 -/1381 -/1489 -/1492
H3
1-/3-phase TPE [mm] -/ - -/- -/- -/- -/- -/-

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

95
Performance curves DN 200
4-pole, PN 16

TP 200-XXX/4

H
[m]
75 TP, TPE 200
70 50 Hz
-660/4
65
60 -590/4

55 -530/4
50 -470/4
45
-400/4
40
-360/4
35
30 -330/4

25
20
0 100 200 300 400 500 600 700 Q [m³/h]
P2
[kW]
140 -660/4

120
-590/4
100
-530/4
80 -470/4
60 -400/4
-360/4
40 -330/4
20
0
0 100 200 300 400 500 600 700 Q [m³/h]
NPSH
[m]
-470/4, -530/4, -590/4, -660/4
14
12
10
8
-330/4, -360/4, -400/4
6
4
2
0
0 100 200 300 400 500 600 700 Q [m³/h]
Eta
[%]
85
80
75
-330/4 -660/4
70 -360/4 -590/4
65 -400/4 -530/4
-470/4
60
55
50
45
0 100 200 300 400 500 600 700 Q [m³/h]
TM03 4651 2007

0 50 100 150 200 Q [l/s]

0 1 2 3 4 5 6 v [m/s]

96
Technical data DN 200
4-pole, PN 16

TM03 8622 4008


Technical data

TP 200 -330/4 -360/4 -400/4 -470/4 -530/4 -590/4 -660/4


TPD - - - - - - -
TPE - - - - - - -
TPED - - - - - - -
Series 300 300 300 300 300 300 300
1-phase TP - - - - - - -
3-phase TP 225 225 250 280 280 315 315
IEC size
1-phase TPE - - - - - - -
3-phase TPE - - - - - - -
1-/3-phase TP★ [kW] -/37 -/45 -/55 -/75 -/90 -/110 -/132
P2
1-/3-phase TPE [kW] -/- -/- -/- -/- -/- -/- -/-
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 200 200 200 200 200 200 200
1-/3-phase TP [mm] -/442 -/442 -/495 -/555 -/555 -/610 -/610
AC
1-/3-phase TPE [mm] -/- -/- -/- -/- -/- -/- -/-
1-/3-phase TP [mm] -/325 -/325 -/392 -/432 -/432 -/495 -/495
AD
1-/3-phase TPE [mm] -/- -/- -/- -/- -/- -/- -/-
AE 1-/3-phase TPE [mm] - - - - - - -
AF 1-/3-phase TPE [mm] - - - - - - -
P [mm] 450 450 550 550 550 660 660
B1★★ [mm] 423/- 423/- 423/- 423/- 423/- 423/- 423/-

B2★★ [mm] 368/- 368/- 368/- 368/- 368/- 368/- 368/-


TP [mm] 423/- 423/- 423/- 432/- 432/- 495/- 495/-
B4★★ 1-phase TPE [mm] - - - - - - -
3-phase TPE [mm] -/- -/- -/- -/- -/- -/- -/-
L1 [mm] 1000 1000 1000 1000 1000 1000 1000
H1 [mm] 295 295 295 295 295 295 295
H2 [mm] 382 382 382 382 382 412 412
1-/3-phase TP [mm] -/1326 -/1386 -/1494 -/1497 -/1607 -/1639 -/1799
H3
1-/3-phase TPE [mm] -/- -/- -/- -/- -/- -/- -/-

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

97
Performance curves DN 250
4-pole, PN 10

TP 250-XXX/4

H
[m]
TP 250
40 -390/4 50 Hz
36

32 -310/4

28
-280/4
24

20

16

12
0 100 200 300 400 500 600 700 800 Q [m³/h]
P2
[kW]

70
-390/4
60

50
-310/4

40 -280/4

30

20
0 100 200 300 400 500 600 700 800 Q [m³/h]
NPSH
[m]
8

2
0 100 200 300 400 500 600 700 800 Q [m³/h]
Eta
[%]
85
80
-390/4
75
-280/4 -310/4
70
65
60
55
50
45
40
0 100 200 300 400 500 600 700 800 Q [m³/h]
TM02 6816 0504

0 50 100 150 200 250 Q [l/s]

0 1 2 3 4 5 v [m/s]

98
Technical data DN 250
4-pole, PN 10

AC

H3
P

H2
H1
D1D D1S
Rp 3/8 L3 L2
L1

C8
C8 C7

TM02 8349 5004


B9

B7
ø

B2
C2

B8
AD

B1
B4
Rp 3/8

Technical data

TP 250 -280/4 -310/4 -390/4


TPD - - -
TPE - - -
TPED - - -
Series 400 400 400
1-phase TP - - -
3-phase TP 225 M 250 M 280 S
IEC size
1-phase TPE - - -
3-phase TPE - - -
★ [kW] 45 55 75
P2
PN 10 10 10
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120]
D1D/D1S [mm] 250/300 250/300 250/300
AC [mm] 442 495 555
AD [mm] 325 392 432
P [mm] 550 550 550
B1 [mm] 223 223 223
B2 [mm] 635 635 635
B4 [mm] 223 223 223
B7 [mm] 647 647 647
B8 [mm] 300 300 300
B9 [mm] 335 335 335
C2 [mm] 580 580 580
C7 [mm] 520 520 520
C8 [mm] 50 50 50
Ø [mm] 20 20 20
L1 [mm] 950 950 950
L2 [mm] 190 190 190
L3 [mm] 620 620 620
H1 [mm] 310 310 310
H2 [mm] 368 368 368
H3 [mm] 1387 1495 1498

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

99
Performance curves DN 125
6-pole, PN 16

TP, TPD, TPE, TPED, 6-pole, PN 16


TP, TPD 125-XXX/6

H
[m]

18 -170/6
TP 125
50 Hz
16
-140/6
14

12 -110/6
-90/6
10

8
-70/6
6 -60/6

2
0 20 40 60 80 100 120 140 Q [m³/h]
P2
[kW]
8 -170/6
7
6
-140/6
5
4 -110/6
3 -90/6
2 -70/6
-60/6
1
0
0 20 40 60 80 100 120 140 Q [m³/h]
NPSH
[m]
2.5 -140/6, -170/6

2.0
-90/6, -110/6
1.5
-60/6, -70/6
1.0

0.5

0.0
0 20 40 60 80 100 120 140 Q [m³/h]
Eta
[%]
80 -70/6
-60/6
75
70
-140/6 -170/6
65 -90/6 -110/6
60
55
50
45
40
0 20 40 60 80 100 120 140 Q [m³/h]
TM02 8757 0904

0 10 20 30 40 Q [l/s]

0 1 2 3 v [m/s]
Note: All curves apply to single-head pumps. For further information, see page 50.

100
Technical data DN 125
6-pole, PN 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 125 -60/6 -70/6 -90/6 -110/6 -140/6 -170/6


TPD z z z z z z
TPE - - - - - -
TPED - - - - - -
Series 300 300 300 300 300 300
1-phase TP - - - - - -
3-phase TP 100 112 132 132 132 160
IEC size
1-phase TPE - - - - - -
3-phase TPE - - - - - -
1-/3-phase TP [kW] -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5
P2
1-/3-phase TPE [kW] -/- -/- -/- -/- -/- -/-
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 125 125 125 125 125 125
1-/3-phase TP [mm] -/203 -/227 -/267 -/267 -/267 -/320
AC
1-/3-phase TPE [mm] -/- -/- -/- -/- -/- -/-
1-/3-phase TP [mm] -/135 -/148 -/167 -/167 -/167 -/197
AD
1-/3-phase TPE [mm] -/- -/- -/- -/- -/- -/-
AE 1-/3-phase TPE [mm] - - - - - -
AF 1-/3-phase TPE [mm] - - - - - -
P [mm] 250 250 300 300 300 350
B1★★ [mm] 202/537 202/537 243/566 243/566 243/566 243/566
★★ [mm] 250/518 250/518 271/552 271/552 271/552 271/552
B2
B3 [mm] 600 600 600 600 600 600
TP [mm] 250/537 250/537 271/566 271/566 271/566 271/566
B4★★ 1-phase TPE [mm] - - - - - -
3-phase TPE [mm] - - - - - -
C1★★ [mm] 230/680 230/680 230/680 230/680 230/680 230/680

C5★★ [mm] 310/84 310/84 400/175 400/175 400/175 400/175


C6 [mm] 300 300 350 350 350 350
L1 [mm] 620 620 800 800 800 800
H1 [mm] 215 215 215 215 215 215
H2 [mm] 267 267 288 288 288 318
1-/3-phase TP [mm] -/829 -/853 -/876 -/914 -/914 -/1011
H3
[mm] -/- -/- -/- -/- -/- -/-
H4 [mm] - - - - - -
M M16 M16 M16 M16 M16 M16

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

101
Performance curves DN 150
6-pole, PN 16

TP, TPD 150-XXX/6

H
[m]
11 TP 150
50 Hz
10 -110/6

8 -90/6

7 -70/6

6
-60/6
5

2
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
P2
[kW]
6 -110/6
5

4 -90/6

3 -70/6
-60/6
2

0
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
NPSH
[m]
2.5

2.0
-60/6, -70/6, -90/6, -110/6
1.5

1.0

0.5

0.0
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
Eta
[%]
80
-110/6
75
-70/6 -90/6
70
-60/6
65
60
55
50
45
40
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
TM02 8758 0904

0 10 20 30 40 50 Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 v [m/s]


Note: All curves apply to single-head pumps. For further information, see page 50.

102
Technical data DN 150
6-pole, PN 16

B4 B4 B4 B4 P
AD P AC AD
AD AC B3 AD

H3
H3
Rp 1/4

H2
H2

H1

TM03 5348 3406 - TM03 5349 3406


H1
D1

H4
D1 B1 B2 L1

H4
B1 B2 L1
M
AE AF AE AF
M

C1
AF

C1
AE

C5 M

C6 C5

Technical data

TP 150 -60/6 -70/6 -90/6 -110/6


TPD z z z z
TPE - - - -
TPED - - - -
Series 300 300 300 300
1-phase TP - - - -
3-phase TP 112 132 132 132
IEC size
1-phase TPE - - - -
3-phase TPE - - - -
1-/3-phase TP [kW] -/2.2 -/3 -/4 -/5.5
P2
1-/3-phase TPE [kW] -/- -/- -/- -/-
PN PN 16 PN 16 PN 16 PN 16
Tmin ; Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 150 150 150 150
1-/3-phase TP [mm] -/227 -/267 -/267 -/267
AC
1-/3-phase TPE [mm] -/- -/- -/- -/-
1-/3-phase TP [mm] -/148 -/167 -/167 -/167
AD
1-/3-phase TPE [mm] -/- -/- -/- -/-
AE 1-/3-phase TPE [mm] - - - -
AF 1-/3-phase TPE [mm] - - - -
P [mm] 250 300 300 300
B1HH [mm] 237/583 237/583 237/583 237/583

B2 HH [mm] 296/553 296/553 296/553 296/553


B3 [mm] 600 600 600 600
TP [mm] 296/583 296/583 296/583 296/583
B4HH 1-phase TPE [mm] - - - -
3-phase TPE [mm] - - - -
C1HH [mm] 230/680 230/680 230/680 230/680

C5HH [mm] 400/153 400/153 400/153 400/153


C6 [mm] 350 350 350 350
L1 [mm] 800 800 800 800
H1 [mm] 215 215 215 215
H2 [mm] 275 291 291 291
1-/3-phase TP [mm] -/862 -/879 -/917 -/917
H3
1-/3-phase TPE [mm] -/- -/- -/- -/-
H4 [mm] - - - -
M M16 M16 M16 M16

 The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.

103
Performance curves DN 100
2-pole, PN 25

TP, 2-pole, PN 25
TP 100-XXX/2

H H
[m] [m]

100
TP 100 180 TP 100
-960/2 50 Hz -1680/2 50 Hz
170
90
160 -1530/2
-820/2
80 150
-1400/2
-700/2 140
70
130
60 -1180/2
-620/2 120
50 110 -1050/2
100
40
90
30
80
20 70
0 40 80 120 160 200 240 280 320Q [m³/h] 0 40 80 120 160 200 240 280 320Q [m³/h]
P2 P2
[kW] [kW]
70 -960/2 160
140 -1680/2
60
-820/2
120 -1530/2
50
100 -1400/2
40 -700/2
80 -1180/2
30 -620/2 -1050/2
60
20 40
10 20
0 0
0 40 80 120 160 200 240 280 Q [m³/h] 0 40 80 120 160 200 240 280 Q [m³/h]
NPSH NPSH
[m] [m]
10 10
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2
0 40 80 120 160 200 240 280 Q [m³/h] 0 40 80 120 160 200 240 280 Q [m³/h]
Eta Eta
[%] [%]
80 -820/2 80
75 75
70 70
-960/2 -1680/2
65 65
-700/2 -1050/2 -1530/2
60 60
-620/2 -1180/2 -1400/2
55 55
50 50
45 45
40 40
0 40 80 120 160 200 240 280 Q [m³/h] 0 40 80 120 160 200 240 280 Q [m³/h]
TTM02 6831 0504
TM02 6830 0504

0 20 40 60 80 Q [l/s] 0 20 40 60 80 Q [l/s]

0 2 4 6 8 10 v [m/s] 0 2 4 6 8 10 v [m/s]

104
Technical data DN 100
2-pole, PN 25

AC

H3
P
Rp 1/2

H2
H1
D1D D1S
Rp 1/2
B9 L1

TM02 8350 5004


B7
B2
B8

C3
C4

B5
B6

B1
B4
AD
C9

Technical data

TP 100 -620/2 -700/2 -820/2 -960/2 -1050/2 -1180/2 -1400/2 -1530/2 -1680/2
TPD - - - - - - - - -
TPE - - - - - - - - -
TPED - - - - - - - - -
Series 400 400 400 400 400 400 400 400 400
1-phase TP - - - - - - - - -
3-phase TP 200 L 225 M 250 M 280 S 280 S 280 M 315 S 315 M 315 L
IEC size
1-phase TPE - - - - - - - - -
3-phase TPE - - - - - - - - -
★ [kW] 37 45 55 75 75 90 110 132 160
P2
PN 25 25 25 25 25 25 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150]
D1D/D1S [mm] 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125
AC [mm] 402 442 495 555 555 555 610 610 610
AD [mm] 305 325 392 432 432 432 495 495 495
P [mm] 550 550 550 550 550 550 800 800 800
B1 [mm] 180 180 180 180 180 180 180 180 180
B2 [mm] 407 407 407 407 425 425 425 425 425
B4 [mm] 180 180 193 227 219 219 312 312 312
B5 [mm] 360 360 360 360 360 360 360 360 360
B6 [mm] 335 335 335 335 335 335 335 335 335
B7 [mm] 467 467 467 467 475 475 600 600 600
B8 [mm] 192 192 192 192 200 200 200 200 200
B9 [mm] 215 215 215 215 225 225 225 225 225
C3 [mm] 320 320 320 320 320 320 320 320 320
C4 [mm] 295 295 295 295 295 295 295 295 295
C9 [mm] 489 489 489 489 606 606 606 606 606
Ø [mm] 20 20 20 20 20 20 20 20 20
L1 [mm] 543 543 543 543 660 660 660 660 660
H1 [mm] 160 160 160 160 170 170 170 170 170
H2 [mm] 315 315 315 315 300 300 303 303 303
H3 [mm] 1133 1184 1222 1295 1290 1400 1405 1565 1565

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

105
Performance curves DN 100
4-pole, PN 25

TP, 4-pole, PN 25
TP 100-XXX/4

H H
[m] [m]
26 -260/4 TP 100 44
TP 100
50 Hz -420/4 50 Hz
24 40 -380/4
-220/4
22
36
20 -320/4
32
18
-190/4
28 -270/4
16
24
14

12 20

10 16

8 12
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 20 40 60 80 100 120 140 160 Q [m³/h]
P2 P2
[kW] [kW]
-420/4
10 20
-260/4
8 16 -380/4
-220/4 -320/4
6 12
-190/4 -270/4
4 8

2 4

0 0
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 20 40 60 80 100 120 140 160 Q [m³/h]
NPSH NPSH
[m] [m]
5 5

4 4

3 3

2 2

1 1

0 0
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 20 40 60 80 100 120 140 160 Q [m³/h]
Eta Eta
[%] [%]
80 80
75 75
-260/4
70 70
65 -190/4 -220/4 65 -420/4
60 60
55 55 -270/4 -380/4

50 50 -320/4

45 45
40 40
0 20 40 60 80 100 120 140 160 Q [m³/h] 0 20 40 60 80 100 120 140 160 Q [m³/h]
TM02 6837 0504

TM02 6838 0504

0 10 20 30 40 50 Q [l/s] 0 10 20 30 40 50 Q [l/s]

0 1 2 3 4 5 v [m/s] 0 1 2 3 4 5 6v [m/s]

106
Technical data DN 100
4-pole, PN 25

AC

H3
P
Rp 1/2

H2
H1
D1D D1S
Rp 1/2
B9 L1

TM02 8350 5004


B7
B2
B8

C3
C4

B5
B6

B1
B4
AD
C9

Technical data

TP 100 -190/4 -220/4 -260/4 -270/4 -320/4 -380/4 -420/4


TPD - - - - - - -
TPE - - - - - - -
TPED - - - - - - -
Series 400 400 400 400 400 400 400
1-phase TP - - - - - - -
3-phase TP 132 S 132 M 160 M 160 M 160 L 180 M 180 L
IEC size
1-phase TPE - - - - - - -
3-phase TPE - - - - - - -
★ [kW] 5.5 7.5 11 11 15 18.5 22
P2
PN 25 25 25 25 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150]
D1D/D1S [mm] 100/125 100/125 100/125 100/125 100/125 100/125 100/125
AC [mm] 267 267 320 320 320 363 363
AD [mm] 167 167 197 197 197 258 258
P [mm] 400 400 400 450 450 450 450
B1 [mm] 180 180 180 180 180 180 180
B2 [mm] 407 407 407 425 425 425 425
B4 [mm] 180 180 180 180 180 180 180
B5 [mm] 360 360 360 360 360 360 360
B6 [mm] 335 335 335 335 335 335 335
B7 [mm] 401 401 401 429 430 429 429
B8 [mm] 192 192 192 200 200 200 200
B9 [mm] 215 215 215 225 225 225 225
C3 [mm] 320 320 320 320 320 320 320
C4 [mm] 295 295 295 295 295 295 295
C9 [mm] 489 489 489 606 606 606 606
Ø [mm] 20 20 20 20 20 20 20
L1 [mm] 543 543 543 660 660 660 660
H1 [mm] 160 160 160 170 170 170 170
H2 [mm] 285 285 285 270 270 270 270
H3 [mm] 817 855 923 918 958 1042 1042

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

107
Performance curves DN 125
4-pole, PN 25

TP 125-XXX/4

H H
[m] [m]

24
-240/4 TP 125 TP 125
45
50 Hz -430/4 50 Hz
22
-200/4 40
-370/4
20
35
-310/
18 4
30
-280/4
16
-150/4
25
14
20
12

10 15

8 10
0 40 80 120 160 200 Q [m³/h] 0 40 80 120 160 200 240 280 Q [m³/h]
P2 P2
[kW] [kW]
14 -240/4 30
-430/4
12 25

10 -200/4 20 -370/4
-310/4
8 15
-280/4
-150/4
6 10
4 5

2 0
0 40 80 120 160 200 Q [m³/h] 0 40 80 120 160 200 240 280 Q [m³/h]
NPSH NPSH
[m] [m]
3.0 5

2.5 4

2.0 3

1.5 2

1.0 1

0.5 0
0 40 80 120 160 200 Q [m³/h] 0 40 80 120 160 200 240 280 Q [m³/h]
Eta Eta
[%] [%]
80 80 -430/4
-370/4
75 -200/4 -240/4 75
70 70
65 -150/4 65
60 60
55 55 -280/4
50 50
45 45 -310/4
40 40
0 40 80 120 160 200 Q [m³/h] 0 40 80 120 160 200 240 280 Q [m³/h]
TM02 6839 0504

TM02 6840 0805

0 20 40 60 Q [l/s] 0 20 40 60 80 Q [l/s]

0 1 2 3 4 5v [m/s] 0 1 2 3 4 5 6 v [m/s]

108
Technical data DN 125
4-pole, PN 25

AC

H3
P
Rp 1/2

H2
H1
D1D D1S
Rp 1/2
B9 L1

TM02 8350 5004


B7
B2
B8

C3
C4

B5
B6

B1
B4
AD
C9

Technical data

TP 125 -150/4 -200/4 -240/4 -280/4 -310/4 -370/4 -430/4


TPD - - - - - - -
TPE - - - - - - -
TPED - - - - - - -
Series 400 400 400 400 400 400 400
1-phase TP - - - - - - -
3-phase TP 132 M 160 M 160 L 160 L 180 M 180 L 200 L
IEC size
1-phase TPE - - - - - - -
3-phase TPE - - - - - - -
★ [kW] 7.5 11 15 15 18.5 22 30
P2
PN 25 25 25 25 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150]
D1D/D1S [mm] 125/150 125/150 125/150 125/150 125/150 125/150 125/150
AC [mm] 267 320 320 320 363 363 402
AD [mm] 167 197 197 197 258 258 305
P [mm] 400 400 400 450 450 450 450
B1 [mm] 200 200 200 200 200 200 200
B2 [mm] 430 430 430 451 451 451 451
B4 [mm] 200 200 200 200 200 200 200
B5 [mm] 400 400 400 400 400 400 400
B6 [mm] 360 360 360 360 360 360 360
B7 [mm] 423 423 423 467 468 468 467
B8 [mm] 200 200 200 224 224 224 224
B9 [mm] 230 230 230 227 227 227 227
C3 [mm] 360 360 360 360 360 360 360
C4 [mm] 320 320 320 320 320 320 320
C9 [mm] 536 536 536 606 606 606 606
Ø [mm] 20 20 20 20 20 20 20
L1 [mm] 590 590 590 660 660 660 660
H1 [mm] 185 185 185 180 180 180 180
H2 [mm] 287 287 287 283 283 283 283
H3 [mm] 883 950 990 981 1065 1065 1121

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

109
Performance curves DN 150
4-pole, PN 25

TP 150-XXX/4

H
[m]
65 -650/4 TP 150
60 50 Hz
55 -530/4
50
45 -430/4
40
-350/4
35
-320/4
30 -270/4
25
20 -240/4

15
10
0 50 100 150 200 250 300 350 400 450Q [m³/h]
P2
[kW]
70 -650/4
60
50 -530/4

40 -430/4
-350/4
30
-320/4
20 -270/4
-240/4
10
0
0 50 100 150 200 250 300 350 400 450Q [m³/h]
NPSH
[m]
7

1
0 50 100 150 200 250 300 350 400 450Q [m³/h]
Eta
[%]
85 -320/4
80
-240/4 -350/4
75
70
65
-430/4
60 -650/4
-530/4
55
-270/4
50
45
40
0 50 100 150 200 250 300 350 400 450Q [m³/h]
TM02 6842 0504

0 20 40 60 80 100 120 Q [l/s]

0 1 2 3 4 5 6 7v [m/s]

110
Technical data DN 150
4-pole, PN 25

AC

H3
P
Rp 1/2

H2
H1
D1D D1S
Rp 1/2
B9 L1

TM02 8350 5004


B7
B2
B8

C3
C4

B5
B6

B1
B4
AD
C9

Technical data

TP 150 -240/4 -270/4 -320/4 -350/4 -430/4 -530/4 -650/4


TPD - - - - - - -
TPE - - - - - - -
TPED - - - - - - -
Series 400 400 400 400 400 400 400
1-phase TP - - - - - - -
3-phase TP 180 M 180 L 200 L 225 S 225 M 250 M 280 S
IEC size
1-phase TPE - - - - - - -
3-phase TPE - - - - - - -
★ [kW] 18.5 22 30 37 45 55 75
P2
PN 25 25 25 25 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150]
D1D/D1S [mm] 150/200 150/200 150/200 150/200 150/200 150/200 150/200
AC [mm] 363 363 402 442 442 495 555
AD [mm] 258 258 305 325 325 392 432
P [mm] 450 450 450 550 550 550 550
B1 [mm] 230 230 230 230 235 235 235
B2 [mm] 504 504 504 504 575 575 575
B4 [mm] 230 230 230 230 235 235 235
B5 [mm] 460 460 460 460 470 470 470
B6 [mm] 400 400 400 400 410 410 410
B7 [mm] 517 517 518 518 584 584 584
B8 [mm] 229 229 229 229 260 260 260
B9 [mm] 275 275 275 275 315 315 315
C3 [mm] 420 420 420 420 420 420 420
C4 [mm] 360 360 360 360 360 360 360
C9 [mm] 676 676 676 676 823 823 823
Ø [mm] 20 20 20 20 20 20 20
L1 [mm] 740 740 740 740 900 900 900
H1 [mm] 225 225 225 225 250 250 250
H2 [mm] 293 293 293 323 325 325 325
H3 [mm] 1120 1120 1177 1197 1284 1392 1395

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

111
Performance curves DN 200
4-pole, PN 25

TP 200-XXX/4

H H
[m] [m]
45 TP 200 65 TP 200
-420/4 -620/4
50 Hz 50 Hz
40 60
-380/4
-560/4
35 55
-510/4
30 -280/4 50
-450/4
25 45
-260/4
20 40

15 35

10 30

5 25

0 20
0 100 200 300 400 500 600 Q [m³/h] 0 100 200 300 400 500 600 Q [m³/h]
P2 P2
[kW] [kW]

50 -420/4 100 -620/4

40 -380/4 80 -560/4
-510/4
30 60
-280/4 -450/4
-260/4
20 40

10 20

0 0
0 100 200 300 400 500 600 Q [m³/h] 0 100 200 300 400 500 600 Q [m³/h]
NPSH NPSH
[m] [m]
6 6

5 5

4 4

3 3

2 2

1 1

0 0
0 100 200 300 400 500 600 Q [m³/h] 0 100 200 300 400 500 600 Q [m³/h]
Eta Eta
[%] [%]
80 90
75 85
80 -620/4
70
-420/4 75 -510/4 -560/4
65
70
60 -380/4 -450/4
65
55 60
50 55
-260/4 -280/4
45 50
40 45
0 100 200 300 400 500 600 Q [m³/h] 0 100 200 300 400 500 600 Q [m³/h]
TM02 6843 0805

TM02 6844 0504

0 50 100 150 Q [l/s] 0 50 100 150 Q [l/s]

0 1 2 3 4 5 6v [m/s] 0 1 2 3 4 5 6v [m/s]

112
Technical data DN 200
4-pole, PN 25

AC

H3
P
Rp 1/2

H2
H1
D1D D1S
Rp 1/2
B9 L1

TM02 8350 5004


B7
B2
B8

C3
C4

B5
B6

B1
B4
AD
C9

Technical data

TP 200 -260/4 -280/4 -380/4 -420/4 -450/4 -510/4 -560/4 -620/4


TPD - - - - - - - -
TPE - - - - - - - -
TPED - - - - - - - -
Series 400 400 400 400 400 400 400 400
1-phase TP - - - - - - - -
3-phase TP 200 L 225 S 225 M 250 M 250 M 280 S 280 M 315 S
IEC size
1-phase TPE - - - - - - - -
3-phase TPE - - - - - - - -
★ [kW] 30 37 45 55 55 75 90 110
P2
PN 25 25 25 25 25 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150]
D1D/D1S [mm] 200/250 200/250 200/250 200/250 200/250 200/250 200/250 200/250
AC [mm] 402 442 442 495 495 555 555 610
AD [mm] 305 325 325 392 392 432 432 495
P [mm] 450 550 550 550 550 550 550 660
B1 [mm] 260 260 260 260 268 268 268 268
B2 [mm] 560 560 560 560 640 640 640 640
B4 [mm] 260 260 260 260 268 268 268 268
B5 [mm] 520 520 520 520 535 535 535 535
B6 [mm] 460 460 460 460 470 470 470 470
B7 [mm] 572 572 572 572 645 645 645 645
B8 [mm] 260 260 260 260 300 300 300 300
B9 [mm] 300 300 300 300 340 340 340 340
C3 [mm] 480 480 480 480 485 485 485 485
C4 [mm] 420 420 420 420 420 420 420 420
C9 [mm] 766 766 766 766 1013 1013 1013 1013
Ø [mm] 20 20 20 20 20 20 20 20
L1 [mm] 830 830 830 830 1100 1100 1100 1100
H1 [mm] 250 250 250 250 290 290 290 290
H2 [mm] 308 338 338 338 327 327 327 357
H3 [mm] 1217 1237 1297 1405 1434 1437 1547 1579

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

113
Performance curves DN 250
4-pole, PN 25

TP 250-XXX/4

H H
[m] [m]

40
TP 250 70 TP 250
50 Hz -660/4 50 Hz
-370/4
65
36 -600/4
60
-320/4
32
55 -540/4

28 -270/4 50 -490/4

24 45
40
20
35
16
30
12 25
8 20
0 100 200 300 400 500 600 700 800 Q [m³/h] 0 100 200 300 400 500 600 700 800 Q [m³/h]
P2 P2
[kW] [kW]

70 160
-660/4
-370/4
140
60
120 -600/4
50
-320/4 100 -540/4
40 -490/4
-270/4 80
30 60

20 40
0 100 200 300 400 500 600 700 800 Q [m³/h] 0 100 200 300 400 500 600 700 800 Q [m³/h]
NPSH NPSH
[m] [m]
5 6

5
4
4
3
3
2
2
1 1

0 0
0 100 200 300 400 500 600 700 800 Q [m³/h] 0 100 200 300 400 500 600 700 800 Q [m³/h]
Eta Eta
[%] [%]
85 -270/4 -600/4
80
80 75
75 -370/4 70
70 -660/4
-320/4 65 -490/4
65 -540/4
60
60
55 55
50 50
45 45
40 40
0 100 200 300 400 500 600 700 800 Q [m³/h] 0 100 200 300 400 500 600 700 800 Q [m³/h]
TM02 6845 0504

TM02 6846 0504

0 50 100 150 200 250 Q [l/s] 0 50 100 150 200 250 Q [l/s]

0 1 2 3 4 5 v [m/s] 0 1 2 3 4 5 v [m/s]

114
Technical data DN 250
4-pole, PN 25

AC

H3
P
Rp 1/2

H2
H1
D1D D1S
Rp 1/2
B9 L1

TM02 8350 5004


B7
B2
B8

C3
C4

B5
B6

B1
B4
AD
C9

Technical data

TP 250 -270/4 -320/4 -370/4 -490/4 -540/4 -600/4 -660/4


TPD - - - - - - -
TPE - - - - - - -
TPED - - - - - - -
Series 400 400 400 400 400 400 400
1-phase TP - - - - - - -
3-phase TP 225 M 250 M 280 S 280 M 315 S 315 M 315 M
IEC size
1-phase TPE - - - - - - -
3-phase TPE - - - - - - -
★ [kW] 45 55 75 90 110 132 160
P2
PN 25 25 25 25 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150]
D1D/D1S [mm] 250/300 250/300 250/300 250/300 250/300 250/300 250/300
AC [mm] 442 495 555 555 610 610 610
AD [mm] 325 392 432 432 495 495 495
P [mm] 550 550 550 660 660 660 660
B1 [mm] 303 303 303 303 303 303 303
B2 [mm] 650 650 650 700 700 700 700
B4 [mm] 303 303 303 303 303 303 303
B5 [mm] 605 605 605 605 605 605 605
B6 [mm] 540 540 540 540 540 540 540
B7 [mm] 647 647 647 720 720 720 720
B8 [mm] 300 300 300 330 330 330 330
B9 [mm] 350 350 350 370 370 370 370
C3 [mm] 550 550 550 550 550 550 550
C4 [mm] 485 485 485 485 485 485 485
C9 [mm] 855 855 855 1106 1106 1106 1106
Ø [mm] 24 24 24 24 24 24 24
L1 [mm] 950 950 950 1200 1200 1200 1200
H1 [mm] 300 300 300 350 350 350 350
H2 [mm] 368 368 368 373 373 358 358
H3 [mm] 1377 1485 1488 1653 1655 1800 1800

 2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with motors as standard.

115
Performance curves DN 300
4-pole, PN 25

TP 300-XXX/4

H
[m]
75
-750/4 TP 300
50 Hz
70
-670/4
65
60 -590/4

55
50
45
40
35
30
25
0 400 800 1200 1600 Q [m³/h]
P2
[kW]

300
-750/4
250
-670/4
200
-590/4
150

100

50
0 400 800 1200 1600 Q [m³/h]
NPSH
[m]
14

12

10

2
0 400 800 1200 1600 Q [m³/h]
Eta
[%]
85
80
-750/4
75
-590/4 -670/4
70
65
60
55
50
45
0 400 800 1200 1600 Q [m³/h]
TM02 6847 0504

0 100 200 300 400 500 Q [l/s]

0 2 4 6 8v [m/s]

116
Technical data DN 300
4-pole, PN 25

AC

H3
P
Rp 1/2

H2
H1
D1D D1S
Rp 1/2
B9 L1

TM02 8350 5004


B7
B2
B8

C3
C4

B5
B6

B1
B4
AD
C9

Technical data

TP 300 -590/4 -670/4 -750/4


TPD - - -
TPE - - -
TPED - - -
Series 400 400 400
1-phase TP - - -
3-phase TP 315 L 315 315
IEC size
1-phase TPE - - -
3-phase TPE - - -
P2 [kW] 200 250 315
PN 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150]
D1D/D1S [mm] 300/350 300/350 300/350
AC [mm] 610 710 710
AD [mm] 495 690 690
P [mm] 660 1150 1150
B1 [mm] 338 338 338
B2 [mm] 790 790 790
B4 [mm] 338 338 338
B5 [mm] 675 675 675
B6 [mm] 605 605 605
B7 [mm] 817 817 817
B8 [mm] 370 370 370
B9 [mm] 420 420 420
C3 [mm] 620 620 620
C4 [mm] 550 550 550
C9 [mm] 1204 1204 1204
Ø [mm] 24 24 24
L1 [mm] 1300 1300 1300
H1 [mm] 375 375 375
H2 [mm] 406 446 446
H3 [mm] 2013 2051 2051

117
Performance curves DN 400
4-pole, PN 25

TP 400-XXX/4

H H
[m] [m]
55 -540/4
TP 400 80 TP 400
-760/4
50 Hz 75 50 Hz
50
-510/4
70 -720/4
45
-470/4 65
-670/4
40 60
35 55

30 50
45
25
40
20
35
15 30
10 25
0 500 1000 1500 2000 2500 3000 3500 Q [m³/h] 0 800 1600 2400 3200 4000 Q [m³/h]
P2 P2
[kW] [kW]

400 600
-760/4
-540/4
500 -720/4
300 -510/4
-670/4
-470/4 400
200
300
100 200

0 100
0 500 1000 1500 2000 2500 3000 3500 Q [m³/h] 0 800 1600 2400 3200 4000 Q [m³/h]
NPSH NPSH
[m] [m]
14 16
12 14
10 12
8 10
6 8
4 6
2 4
0 2
0 500 1000 1500 2000 2500 3000 3500 Q [m³/h] 0 800 1600 2400 3200 4000 Q [m³/h]
Eta Eta
[%] [%]
80 85
-670/4
75 80
-470/4 -540/4 -720/4
70 75
-510/4 70
65
65 -760/4
60
60
55 55
50 50
45 45
40 40
0 500 1000 1500 2000 2500 3000 3500 Q [m³/h] 0 800 1600 2400 3200 4000 Q [m³/h]
TM02 6848 0504

TM02 6849 0504

0 200 400 600 800 1000 Q [l/s] 0 400 800 1200 Q [l/s]

0 2 4 6 8 v [m/s] 0 2 4 6 8 10 v [m/s]

118
Technical data DN 400
4-pole, PN 25

P
AC

H3
Rp 1/2

H2
PN 40 PN 40

H1
D1D Rp 1/2 D1S
L1

B9

TM02 8351 3307


B2
ø

B7
B8
C3
C4

B5
B6

B1
B4
C9 AD

Technical data

TP 400 -470/4 -510/4 -540/4 -670/4 -720/4 -760/4


TPD - - - - - -
TPE - - - - - -
TPED - - - - - -
Series 400 400 400 400 400 400
1-phase TP - - - - - -
3-phase TP 315 355 355 355 400 400
IEC size
1-phase TPE - - - - - -
3-phase TPE - - - - - -
P2 [kW] 315 355 400 500 560 630
PN 25 25 25 25 25 25
Tmin ; Tmax [°C] [0;150] [0;150] [0;150] [0;150] [0;150] [0;150]
D1D/D1S [mm] 400/500 400/500 400/500 400/500 400/500 400/500
AC [mm] 710 790 790 790 880 880
AD [mm] 690 725 725 875 925 925
P [mm] 1150 900 900 900 1150 1150
B1 [mm] 448 448 448 448 448 448
B2 [mm] 1064 1064 1064 1064 1064 1064
B4 [mm] 448 448 448 448 448 448
B5 [mm] 895 895 895 895 895 895
B6 [mm] 800 800 800 800 800 800
B7 [mm] 1066 1066 1066 1066 1066 1066
B8 [mm] 500 500 500 500 500 500
B9 [mm] 564 564 564 564 564 564
C3 [mm] 830 830 830 830 830 830
C4 [mm] 735 735 735 735 735 735
C9 [mm] 1302 1302 1302 1302 1302 1302
Ø [mm] 27 27 27 27 27 27
L1 [mm] 1400 1400 1400 1400 1400 1400
H1 [mm] 450 450 450 450 450 450
H2 [mm] 706 706 706 706 706 706
H3 [mm] 2386 2611 2611 2611 2771 2771

119
Weights and shipping volume TP, TPD, TPE, TPED

TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16


Connection Weights
Shipping volume [m3]
Pump type Net [kg] Gross [kg]
D1 D D1 S
TP/TPD TPE/TPED TP/TPD TPE/TPED TP/TPD TPE/TPED
TP 25-50/2 R G 1/2 G 1/2 7.2/- - 8.2/- - 0.020/- -
TP 25-90/2 R G 1/2 G 1/2 7.5/- 10.7/- 8.5/- 12.7/- 0.020/- 0.036/-
TP 32-50 /2 R G2 G2 7.8/- - 8.8/- - 0.020/- -
TP 32-90/2 R G2 G2 8.2/- 11.8/- 9.2/- 13.8/- 0.020/- 0.036/-
TP, TPD 32-60/2 DN 32 DN 32 15.9/31.8 22.1/39.3 16.9/32.8 25.3/42.7 0.036/0.072 0.064/0.151
TP, TPD 32-120/2 DN 32 DN 32 19.2/38.0 21.3/42.2 20.2/40.0 22.3/44.2 0.036/0.072 0.056/0.072
TP, TPD 32-150/2 DN 32 DN 32 22.8/54.0 29.3/58.5 26.0/57.0 32.5/61.9 0.064/0.082 0.064/0.151
TP, TPD 32-180/2 DN 32 DN 32 24.1/54.0 29.0/58.9 27.3/57.0 32.2/61.9 0.064/0.082 0.064/0.082
TP, TPD 32-230/2 DN 32 DN 32 24.7/54.0 41.3/81.4 27.9/57.0 44.5/85.4 0.064/0.082 0.091/0.221
TP, TPD 32-200/2 DN 32 DN 32 43.7/88.5 49.8/100.6 48.7/105.0 61.7/117.9 0.138/0.3912 0.138/0.3912
TP, TPD 32-250/2 DN 32 DN 32 45.9/92.9 51.9/104.6 50.9/109.4 57.4/123.3 0.138/0.3912 0.184/0.3912
TP, TPD 32-320/2 DN 32 DN 32 51.3/103.7 56.6/114.0 56.6/120.2 62.1/132.7 0.184/0.3912 0.184/0.3912
TP, TPD 32-380/2 DN 32 DN 32 62.9/126.9 64.6/130.0 68.2/144.3 70.1/148.6 0.184/0.4584 0.184/0.5184
TP, TPD 32-460/2 DN 32 DN 32 75.6/151.2 78.7/157.1 82.0/168.6 85.4/175.7 0.2176/0.4584 0.2176/0.5184
TP, TPD 32-580/2 DN 32 DN 32 90.3/180.4 94.8/189.4 105.5/197.9 113.4/208.0 0.2176/0.4584 0.2176/0.5184
TP 40-50/2 DN 40 DN 40 11.5/- - 12.5/- - 0.020/- -
TP, TPD 40-60/2 DN 40 DN 40 20.2/42.0 22.8/47.6 21.2/43.0 25.3/51.6 0.036/0.072 0.056/0.072
TP 40-90/2 DN 40 DN 40 12.0/- 17.3/- 13.0/- 18.3/- 0.020/- 0.025/-
TP, TPD 40-120/2 DN 40 DN 40 19.7/40.5 22.3/45.7 20.7/42.5 24.3/49.7 0.036/0.072 0.056/0.072
TP 40-180/2 DN 40 DN 40 23.5/- 28.7/- 24.5/- 31.9/- 0.036/- 0.064/-
TP, TPD 40-190/2 DN 40 DN 40 28.8/53.8 44.2/81.6 32.0/59.3 47.6/87.1 0.064/0.151 0.091/0.221
TP, TPD 40-230/2 DN 40 DN 40 37.3/57.2 45.8/80.7 40.4/62.7 49.2/86.2 0.064/0.151 0.091/0.221
TP, TPD 40-270/2 DN 40 DN 40 38.9/69.5 36.7/74.9 42.1/75.0 40.1/80.4 0.064/0.151 0.091/0.221
TP, TPD 40-240/2 DN 40 DN 40 53.1/107.3 58.3/117.7 58.3/123.8 63.8/136.3 0.184/0.3912 0.184/0.3912
TP, TPD 40-300/2 DN 40 DN 40 64.5/130.1 66.2/133.4 69.7/147.6 71.7/152.1 0.184/0.4584 0.184/0.5184
TP, TPD 40-360/2 DN 40 DN 40 69.6/140.3 72.6/146.2 74.8/157.8 78.1/164.9 0.184/0.4584 0.184/0.5184
TP, TPD 40-470/2 DN 40 DN 40 90.2/183.2 94.7/192.1 105.4/200.7 113.3/210.8 0.2176/0.4584 0.2176/0.5184
TP, TPD 40-580/2 DN 40 DN 40 92.1/187.0 106.2/215.1 107.3/204.3 124.8/233.8 0.2176/0.4584 0.2176/0.5184
TP, TPD 50-60/2 DN 50 DN 50 20.2/45.0 24.4/49.5 21.2/48.0 27.6/52.9 0.056/0.072 0.064/0.151
TP, TPD 50-120/2 DN 50 DN 50 28.2/56.3 39.8/83.4 29.2/58.3 40.8/85.4 0.056/0.072 0.091/0.221
TP, TPD 50-180/2 DN 50 DN 50 27.7/55.8 41.4/83.1 28.7/57.8 44.6/86.5 0.056/0.072 0.091/0.221
TP, TPD 50-160/2 DN 50 DN 50 46.7/94.0 52.7/105.9 51.7/110.5 64.6/123.3 0.138/0.3912 0.184/0.3912
TP, TPD 50-190/2 DN 50 DN 50 48.8/98.2 54.8/110.0 53.8/114.7 60.3/128.6 0.138/0.3912 0.184/0.3912
TP, TPD 50-240/2 DN 50 DN 50 54.1/108.8 59.4/119.2 59.4/125.3 64.9/137.8 0.184/0.3912 0.184/0.3912
TP, TPD 50-290/2 DN 50 DN 50 65.5/131.6 67.3/134.9 70.8/149.1 72.8/153.6 0.184/0.4584 0.184/0.5184
TP, TPD 50-360/2 DN 50 DN 50 71.6/144.2 74.6/150.1 76.8/161.7 80.1/168.8 0.184/0.4584 0.184/0.5184
TP, TPD 50-430/2 DN 50 DN 50 86.4/174.0 91.0/182.9 101.7/191.4 109.5/201.5 0.184/0.4584 0.184/0.5184
TP, TPD 50-440/2 DN 50 DN 50 100.2/204.4 114.3/232.5 115.4/223.6 132.9/251.2 0.2176/0.5184 0.2176/0.5184
TP, TPD 50-570/2 DN 50 DN 50 147.9/299.8 181.0/366.0 164.9/320.9 199.6/392.2 0.7248/0.6507 0.7248/1.524
TP, TPD 50-710/2 DN 50 DN 50 159.7/323.4 184.8/373.6 176.7/344.5 203.4/399.8 0.7248/0.6507 0.7248/1.524
TP, TPD 50-830/2 DN 50 DN 50 169.9/343.8 209.0/422.0 186.9/364.9 227.6/448.2 0.7248/0.6507 0.7248/1.524
TP, TPD 50-900/2 DN 50 DN 50 199.0/402.1 222.1/448.2 217.6/428.3 240.7/474.4 0.7248/0.6507 0.7248/1.524
TP, TPD 65-60/2 DN 65 DN 65 26.7/53.0 30.4/59.6 27.7/56.0 33.6/63.0 0.056/0.140 0.064/0.151
TP, TPD 65-120/2 DN 65 DN 65 32.6/66.6 40.6/86.6 34.6/69.6 42.6/90.6 0.056/0.140 0.091/0.221
TP, TPD 65-180/2 DN 65 DN 65 38.0/76.9 45.8/92.5 41.0/79.9 48.8/95.5 0.066/0.140 0.091/0.221
TP, TPD 65-190/2 DN 65 DN 65 57.9/116.4 63.1/126.7 63.1/132.9 68.7/145.3 0.184/0.3912 0.184/0.3912
TP, TPD 65-230/2 DN 65 DN 65 69.3/139.2 71.0/142.5 74.5/156.6 76.6/161.1 0.184/0.4584 0.184/0.5184
TP, TPD 65-260/2 DN 65 DN 65 74.3/149.2 77.3/155.1 79.5/166.6 82.9/173.7 0.184/0.4584 0.184/0.5184
TP, TPD 65-340/2 DN 65 DN 65 89.2/178.9 93.7/187.8 104.4/196.4 112.3/206.5 0.184/0.4584 0.184/0.5184
TP, TPD 65-410/2 DN 65 DN 65 91.1/182.7 105.2/210.8 106.3/200.2 123.8/229.5 0.184/0.4584 0.184/0.5184
TP, TPD 65-460/2 DN 65 DN 65 149.4/306.4 182.5/372.5 166.4/327.4 201.1/398.8 0.7248/0.6507 0.7248/1.524
TP, TPD 65-550/2 DN 65 DN 65 160.7/329.0 185.8/379.1 177.7/350.0 204.4/405.4 0.7248/0.6507 0.7248/1.524
TP, TPD 65-660/2 DN 65 DN 65 170.9/349.4 210.0/427.5 187.9/370.4 228.6/453.8 0.7248/0.6507 0.7248/1.524
TP, TPD 65-720/2 DN 65 DN 65 200.6/408.8 223.8/454.9 219.2/435.0 242.3/481.2 0.7248/1.524 0.7248/1.524
TP, TPD 65-930/2 DN 65 DN 65 290.9/589.5 - 309.5/615.7 - 0.7248/1.524 -
TP, TPD 80-120/2 DN 80 DN 80 43.5/83.0 52.6/100.7 44.5/86.0 57.1/106.7 0.066/0.140 0.091/0.370

120
Weights and shipping volume TP, TPD, TPE, TPED

Connection Weights
Shipping volume [m3]
Pump type Net [kg] Gross [kg]
D1 D D1 S
TP/TPD TPE/TPED TP/TPD TPE/TPED TP/TPD TPE/TPED
TP, TPD 80-140/2 DN 80 DN 80 61.0/124.0 66.5/134.0 74.0/141.0 78.5/151.0 0.184/0.3912 0.184/0.3912
TP, TPD 80-180/2 DN 80 DN 80 65.0/132.0 74.5/150.0 78.0/149.0 88.5/180.0 0.184/0.4584 0.184/0.6507
TP, TPD 80-210/2 DN 80 DN 80 78.0/157.0 80.7/162.4 90.0/174.0 94.7/192.4 0.184/0.4584 0.184/0.5184
TP, TPD 80-240/2 DN 80 DN 80 93.0/187.0 97.6/195.2 105.0/204.0 118.6/225.2 0.184/0.4584 0.7248/0.5184
TP, TPD 80-250/2 DN 80 DN 80 101.0/211.0 115.8/238.6 115.0/230.0 136.8/268.6 0.2176/0.5184 0.7248/0.5184
TP, TPD 80-330/2 DN 80 DN 80 148.0/304.0 181.0/370.0 169.0/334.0 203.0/420.6 0.7248/0.6507 0.7248/0.6507
TP, TPD 80-400/2 DN 80 DN 80 160.0/327.0 185.0/377.0 180.0/356.0 205.0/425.0 0.7248/0.6507 0.7248/0.6507
TP, TPD 80-520/2 DN 80 DN 80 176.0/349.0 215.0/427.0 197.0/379.0 236.0/477.0 0.7248/1.524 0.7248/1.524
TP, TPD 80-570/2 DN 80 DN 80 205.0/407.0 228.0/453.0 226.0/457.0 249.0/503.0 0.7248/1.524 0.7248/1.524
TP, TPD 80-700/2 DN 80 DN 80 295.0/587.0 - 316.0/637.0 - 0.7248/1.524 -
TP, TPD 100-120/2 DN 100 DN 100 53.0/108.5 61.1/124.7 55.0/113.5 66.1/130.7 0.140/0.213 0.120/0.370
TP, TPD 100-160/2 DN 100 DN 100 93.0/196.0 95.7/202.4 107.0/246.0 109.7/252.4 0.2176/0.5184 0.2176/0.6507
TP, TPD 100-200/2 DN 100 DN 100 108.0/226.0 112.6/235.2 122.0/276.0 134.6/285.2 0.7248/0.5184 0.7248/0.6507
TP, TPD 100-240/2 DN 100 DN 100 110.0/230.0 127.0/264.0 124.0/280.0 149.0/314.0 0.7248/0.5184 0.7248/0.6507
TP, TPD 100-250/2 DN 100 DN 100 173.0/347.0 206.0/413.0 197.0/397.0 230.0/463.0 0.7248/1.524 0.7248/1.524
TP, TPD 100-310/2 DN 100 DN 100 184.0/370.0 209.0/420.0 208.0/420.0 233.0/470.0 0.7248/1.524 0.7248/1.524
TP, TPD 100-360/2 DN 100 DN 100 195.0/390.0 234.0/468.0 218.0/440.0 257.0/518.0 0.7248/1.524 0.7248/1.524
TP, TPD 100-390/2 DN 100 DN 100 224.0/449.0 247.0/495.0 247.0/499.0 270.0/545.0 0.7248/1.524 0.7248/1.524
TP, TPD 100-480/2 DN 100 DN 100 329.0/661.0 - - - 0.797/1.800 -
 The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16


Connection Weights
Shipping volume [m3]
Pump type Net [kg] Gross [kg]
D1D D1S
TP/TPD TPE/TPED TP/TPD TPE/TPED TP/TPD TPE/TPED
TP, TPD 32-30/4 DN 32 DN 32 15.9/30.8 21.7/38.8 16.9/31.8 24.9/42.2 0.036/0.072 0.064/0.151
TP, TPD 32-40/4 DN 32 DN 32 25.2/32.0 29.1/54.7 28.4/33.0 32.3/58.1 0.064/0.072 0.064/0.151
TP, TPD 32-60/4 DN 32 DN 32 25.2/50.7 29.1/54.7 28.4/53.7 32.3/58.1 0.036/0.082 0.064/0.151
TP, TPD 32-80/4 DN 32 DN 32 35.2/69.9 36.9/74.9 40.2/86.4 48.8/92.2 0.138/0.3912 0.184/0.3912
TP, TPD 32-100/4 DN 32 DN 32 36.3/71.7 37.2/75.5 41.2/88.3 49.1/92.8 0.138/0.3912 0.184/0.3912
TP, TPD 32-120/4 DN 32 DN 32 49.7/94.2 48.3/96.5 55.8/110.7 61.1/113.8 0.1632/0.3912 0.2176/0.3912
TP, TPD 40-30/4 DN 40 DN 40 17.4/33.0 23.3/41.3 18.4/34.3 26.5/44.7 0.036/0.072 0.064/0.151
TP 40-60/4 DN 40 DN 40 22.5/42.0 27.2/- 23.5/43.0 30.4/- 0.036/0.072 0.064/-
TP, TPD 40-90/4 DN 40 DN 40 28.9/50.9 32.8/49.3 32.3/56.4 36.0/54.8 0.076/0.151 0.076/0.151
TP, TPD 40-100/4 DN 40 DN 40 41.0/83.1 42.2/85.6 45.9/99.6 54.1/103.0 0.138/0.3912 0.184/0.3912
TP, TPD 40-130/4 DN 40 DN 40 48.4/99.6 58.6/120.0 54.4/116.1 71.4/137.4 0.1632/0.3912 0.184/0.3912
TP, TPD 40-160/4 DN 40 DN 40 54.5/112.0 64.5/131.7 60.6/128.5 71.2/150.3 0.2176/0.3912 0.2176/0.3912
TP, TPD 50-30/4 DN 50 DN 50 24.4/46.3 30.3/51.9 25.4/48.3 33.5/55.3 0.036/0.072 0.064/0.151
TP, TPD 50-60/4 DN 50 DN 50 25.5/50.5 28.5/56.4 26.5/52.5 30.5/61.9 0.056/0.072 0.056/0.072
TP, TPD 50-90/4 DN 50 DN 50 43.0/87.0 44.2/89.5 47.9/103.5 56.1/106.9 0.138/0.3912 0.184/0.3912
TP, TPD 50-110/4 DN 50 DN 50 56.5/117.1 66.7/137.5 62.5/136.3 79.5/167.5 0.1632/0.5184 0.2176/0.5184
TP, TPD 50-130/4 DN 50 DN 50 62.7/129.4 72.6/149.1 68.7/148.6 79.4/167.8 0.1632/0.5184 0.2176/0.5184
TP, TPD 50-160/4 DN 50 DN 50 65.1/134.2 73.9/151.7 71.1/153.4 80.7/170.4 0.2176/0.5184 0.2176/0.5184
TP, TPD 50-190/4 DN 50 DN 50 72.4/148.9 83.8/171.6 78.8/168.1 90.6/190.2 0.2176/0.5184 0.2176/0.5184
TP, TPD 50-230/4 DN 50 DN 50 76.9/157.9 80.9/165.8 83.3/177.1 87.7/184.4 0.2176/0.5184 0.2176/0.5184
TP, TPD 65-30/4 DN 65 DN 65 33.0/56.5 37.8/62.1 35.0/59.5 41.0/65.5 0.056/0.140 0.064/0.151
TP, TPD 65-60/4 DN 65 DN 65 33.7/63.8 36.3/69.0 34.7/66.8 38.8/79.5 0.056/0.140 0.056/0.140
TP, TPD 65-90/4 DN 65 DN 65 47.1/94.9 57.3/115.3 52.1/111.4 69.4/132.6 0.1632/0.3912 0.184/0.3912
TP, TPD 65-110/4 DN 65 DN 65 64.2/136.1 74.2/155.8 70.3/152.6 80.9/174.4 0.2176/0.3912 0.2176/0.4584
TP, TPD 65-130/4 DN 65 DN 65 66.5/140.6 75.3/158.1 72.5/157.1 82.1/176.7 0.2176/0.3912 0.2176/0.4584
TP, TPD 65-150/4 DN 65 DN 65 73.5/154.6 84.9/177.3 79.9/172.0 91.7/195.9 0.2176/0.4584 0.2176/0.5184
TP, TPD 65-170/4 DN 65 DN 65 77.8/163.2 81.8/171.1 84.2/180.6 88.6/189.7 0.2176/0.4584 0.2176/0.5184
TP, TPD 65-240/4 DN 65 DN 65 82.7/173.0 101.8/210.9 89.1/190.5 108.5/229.6 0.2176/0.4584 0.2176/0.5184
TP, TPD 80-30/4 DN 80 DN 80 37.5/68.3 41.1/72.8 39.5/71.3 44.3/76.2 0.056/0.140 0.064/0.151
TP, TPD 80-60/4 DN 80 DN 80 38.6/71.6 50.4/95.3 40.6/74.6 53.4/100.8 0.066/0.140 0.091/0.370
TP, TPD 80-70/4 DN 80 DN 80 68.0/143.0 74.1/156.2 81.0/161.0 87.1/173.2 0.2176/0.3912 0.2176/0.4584
TP, TPD 80-90/4 DN 80 DN 80 71.0/150.0 75.0/158.0 84.0/167.0 88.0/175.0 0.2176/0.4584 0.2176/0.4584

121
Weights and shipping volume TP, TPD, TPE, TPED

Connection Weights
Shipping volume [m3]
Pump type Net [kg] Gross [kg]
D1D D1S
TP/TPD TPE/TPED TP/TPD TPE/TPED TP/TPD TPE/TPED
TP, TPD 80-110/4 DN 80 DN 80 76.0/159.0 84.5/176.0 89.0/176.0 98.5/206.0 0.2176/0.4584 0.2176/0.5184
TP, TPD 80-150/4 DN 80 DN 80 84.0/164.0 87.5/171.0 98.0/184.0 101.5/201.0 0.2176/0.5184 0.2176/0.6507
TP, TPD 80-170/4 DN 80 DN 80 103.0/203.0 106.3/209.6 117.0/222.0 120.3/239.6 0.2176/0.5184 0.7248/0.6507
TP, TPD 80-240/4 DN 80 DN 80 182.0/369.0 180.8/366.6 206.0/419.0 204.8/417.6 0.9696/1.524 0.9696/1.524
TP, TPD 80-270/4 DN 80 DN 80 193.0/391.0 205.0/416.0 217.0/441.0 230.0/466.0 0.9696/1.524 0.9696/1.524
TP, TPD 80-340/4 DN 80 DN 80 220.0/446.0 233.0/472.0 244.0/496.0 258.0/522.0 0.9696/1.524 0.9696/1.524
TP, TPD 100-30/4 DN 100 DN 100 41.0/85.0 43.0/93.0 44.0/90.0 46.2/103.0 0.140/0.213 0.151/0.220
TP, TPD 100-60/4 DN 100 DN 100 53.0/109.0 63.7/122.6 56.0/114.0 67.7/127.6 0.140/0.213 0.120/0.370
TP, TPD 100-70/4 DN 100 DN 100 96.0/193.0 100.0/201.0 110.0/210.0 114.0/251.0 0.7248/0.6507 0.7248/0.6507
TP, TPD 100-90/4 DN 100 DN 100 100.0/202.0 109.0/218.0 125.0/252.0 133.0/268.0 0.7248/0.6507 0.7248/0.6507
TP, TPD 100-110/4 DN 100 DN 100 103.0/207.0 106.5/213.0 127.0/257.0 130.5/264.0 0.7248/0.6507 0.7248/0.6507
TP, TPD 100-130/4 DN 100 DN 100 141.0/286.0 144.3/292.6 166.0/336.0 169.3/342.6 0.7248/1.524 0.7248/1.524
TP, TPD 100-170/4 DN 100 DN 100 156.0/316.0 155.8/313.6 180.0/366.0 189.8/364.6 0.7248/1.524 0.7248/1.524
TP, TPD 100-200/4 DN 100 DN 100 227.0/475.0 240.0/500.0 252.0/525.0 290.0/550.0 0.9696/1.524 0.9696/1.524
TP, TPD 100-250/4 DN 100 DN 100 255.0/530.0 268.0/556.0 279.0/580.0 318.0/606.0 0.9696/1.524 0.9696/1.524
TP, TPD 100-330/4 DN 100 DN 100 273.0/565.0 291.0/601.0 297.0/616.0 341.0/652.0 0.9696/1.524 0.9696/1.524
TP, TPD 100-370/4 DN 100 DN 100 302.0/623.0 330.0/679.0 344.0/674.0 380.0/730.0 0.9696/1.524 0.9696/1.800
TP, TPD 100-410/4 DN 100 DN 100 312.0/645.0 - 354.0/695.0 - 0.9696/1.800
TP, TPD 125-110/4 DN 125 DN 125 185.0/397.0 188.3/403.6 215.0/447.0 218.3/453.6 0.9696/1.524 0.9696/1.524
TP, TPD 125-130/4 DN 125 DN 125 200.0/426.0 198.8/400.6 230.0/477.0 249.8/474.6 0.9696/1.524 0.9696/1.524
TP, TPD 125-160/4 DN 125 DN 125 210.0/447.0 223.0/472.0 240.0/498.0 273.0/523.0 0.9696/1.524 0.9696/1.524
TP, TPD 125-210/4 DN 125 DN 125 279.0/566.0 292.0/592.0 309.0/616.0 342.0/642.0 0.9696/1.524 0.9696/1.524
TP, TPD 125-250/4 DN 125 DN 125 296.0/599.0 314.0/635.0 346.0/650.0 364.0/686.0 0.9696/1.800 0.9696/1.524
TP, TPD 125-320/4 DN 125 DN 125 326.0/659.0 354.0/715.0 383.0/717.0 424.0/766.0 0.9696/1.800 0.9696/1.524
TP, TPD 125-360/4 DN 125 DN 125 336.0/681.0 - 394.0/738.0 - 0.9696/1.800 -
TP, TPD 125-420/4 DN 125 DN 125 435.0/878.0 - 492.0/935.0 - 1.800/1.800 -
TP, TPD 150-130/4 DN 150 DN 150 273.0/550.0 286.0/575.0 303.0/600.0 336.0/625.0 0.9696/1.524 0.9696/1.524
TP, TPD 150-160/4 DN 150 DN 150 301.0/605.0 314.0/631.0 331.0/655.0 364.0/681.0 0.9696/1.524 0.9696/1.524
TP, TPD 150-200/4 DN 150 DN 150 318.0/639.0 336.0/675.0 368.0/690.0 386.0/756.0 0.9696/1.800 0.9696/1.800
TP, TPD 150-220/4 DN 150 DN 150 347.0/697.0 375.0/753.0 404.0/755.0 425.0/804.0 0.9696/1.800 0.9696/1.800
TP, TPD 150-250/4 DN 150 DN 150 358.0/718.0 - 415.0/776.0 - 0.9696/1.800 -
TP 150-260/4 DN 150 DN 150 356.0/- 388/- 529.0/- 561.0/- 2.3/- 2.3/-
TP 150-280/4 DN 150 DN 150 377.0/- - 621.0/- - 2.3/- -
TP 150-340/4 DN 150 DN 150 437.0/- - 607.0/- - 2.3/- -
TP 150-390/4 DN 150 DN 150 540.0/- - 709.0/- - 2.3/- -
TP 200-180/4 DN 200 DN 200 462.0/- - 635.0/- - 2.3/- -
TP 200-220/4 DN 200 DN 200 521.0/- - 694.0/- - 2.3/- -
TP 200-250/4 DN 200 DN 200 625.0/- - 794.0/- - 2.3/- -
TP 200-270/4 DN 200 DN 200 666.0/- - 835.0/- - 2.3/- -
TP 200-320/4 DN 200 DN 200 817.0/- - 1016.0/- - 3.1/- -
TP 200-330/4 DN 200 DN 200 720.0/- - 923.0/- - 3.1/- -
TP 200-360/4 DN 200 DN 200 761.0/- - 964.0/- - 3.1/- -
TP 200-400/4 DN 200 DN 200 911.0/- - 1110.0/- - 3.1/- -
TP 200-410/4 DN 200 DN 200 935.0/- - 1133.0/- - 3.1/- -
TP 200-470/4 DN 200 DN 200 1029.0/- - 1228.0/- - 3.1/- -
TP 200-530/4 DN 200 DN 200 1131.0/- - 1364.0/- - 4.6/- -
TP 200-590/4 DN 200 DN 200 1331.0/- - 1563.0/- - 4.6/- -
TP 200-660/4 DN 200 DN 200 1488.0/- - 1720.0/- - 4.6/- -
TP 250-280/4 DN 250 DN 300 690.0 - 875.0 - 3.13 -
TP 250-310/4 DN 250 DN 300 820.0 - 1005.0 - 3.13 -
TP 250-390/4 DN 250 DN 300 935.0 - 1120.0 - 3.13 -
 The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

122
Weights and shipping volume TP, TPD, TPE, TPED

TP, TPD, 6-pole, PN 6, 10, 16


Connection Weights
Shipping volume [m3]
Pump type Net [kg] Gross [kg]
D1D D1S
TP/TPD TPE/TPED TP/TPD TPE/TPED TP/TPD TPE/TPED
TP, TPD 125-60/6 DN 125 DN 125 157.0/341.0 - 187.0/391.0 - 0.9696/1.524 -
TP, TPD 125-70/6 DN 125 DN 125 166.0/359.0 - 196.0/409.0 - 0.9696/1.524 -
TP, TPD 125-90/6 DN 125 DN 125 230.0/469.0 - 260.0/519.0 - 0.9696/1.524 -
TP, TPD 125-110/6 DN 125 DN 125 237.0/482.0 - 267.0/533.0 - 0.9696/1.524 -
TP, TPD 125-140/6 DN 125 DN 125 244.0/496.0 - 274.0/546.0 - 0.9696/1.524 -
TP, TPD 125-170/6 DN 125 DN 125 280.0/567.0 - 310.0/618.0 - 0.9696/1.524 -
TP, TPD 150-60/6 DN 150 DN 150 229.0/461.0 - 259.0/512.0 - 0.9696/1.524 -
TP, TPD 150-70/6 DN 150 DN 150 253.0/508.0 - 283.0/558.0 - 0.9696/1.524 -
TP, TPD 150-90/6 DN 150 DN 150 259.0/522.0 - 289.0/572.0 - 0.9696/1.524 -
TP, TPD 150-110/6 DN 150 DN 150 265.0/534.0 - 295.0/584.0 - 0.9696/1.524 -
 The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

TP, 2-pole, PN 25
Connection Weights Shipping volume
Pump type
D1D D1 S Net [kg] Gross [kg] [m3]
TP 100-620/2 DN 100 DN 125 374.0 529.0 2.29
TP 100-700/2 DN 100 DN 125 490.0 645.0 2.29
TP 100-820/2 DN 100 DN 125 580.0 735.0 2.29
TP 100-960/2 DN 100 DN 125 690.0 875.0 3.13
TP 100-1050/2 DN 100 DN 125 755.0 940.0 3.13
TP 100-1180/2 DN 100 DN 125 840.0 1025.0 3.13
TP 100-1400/2 DN 100 DN 125 1015.0 1200.0 3.13
TP 100-1530/2 DN 100 DN 125 1140.0 1325.0 3.13
TP 100-1680/2 DN 100 DN 125 1280.0 1500.0 4.57

TP, 4-pole, PN 25
Connection Weights Shipping volume
Pump type
D1D D1 S Net [kg] Gross [kg] [m3]
TP 100-190/4 DN 100 DN 125 215.0 245.0 0.72
TP 100-220/4 DN 100 DN 125 225.0 255.0 0.72
TP 100-260/4 DN 100 DN 125 241.0 271.0 0.72
TP 100-270/4 DN 100 DN 125 306.0 339.0 0.70
TP 100-320/4 DN 100 DN 125 332.0 365.0 0.70
TP 100-380/4 DN 100 DN 125 351.0 384.0 0.70
TP 100-420/4 DN 100 DN 125 371.0 404.0 0.70
TP 125-150/4 DN 125 DN 150 245.0 278.0 0.70
TP 125-200/4 DN 125 DN 150 261.0 294.0 0.70
TP 125-240/4 DN 125 DN 150 287.0 320.0 0.70
TP 125-280/4 DN 125 DN 150 287.0 320.0 0.70
TP 125-310/4 DN 125 DN 150 371.0 404.0 0.70
TP 125-370/4 DN 125 DN 150 391.0 424.0 0.70
TP 125-430/4 DN 125 DN 150 444.0 599.0 2.29
TP 150-240/4 DN 150 DN 200 411.0 566.0 2.29
TP 150-270/4 DN 150 DN 200 431.0 586.0 2.29
TP 150-320/4 DN 150 DN 200 484.0 639.0 2.29
TP 150-350/4 DN 150 DN 200 575.0 730.0 2.29
TP 150-430/4 DN 150 DN 200 655.0 810.0 2.29
TP 150-530/4 DN 150 DN 200 785.0 970.0 3.13
TP 150-650/4 DN 150 DN 200 900.0 1085.0 3.13
TP 200-270/4 DN 200 DN 250 539.0 694.0 2.29
TP 200-280/4 DN 200 DN 250 630.0 785.0 2.29
TP 200-380/4 DN 200 DN 250 670.0 825.0 2.29
TP 200-420/4 DN 200 DN 250 800.0 985.0 3.13
TP 200-450/4 DN 200 DN 250 860.0 1045.0 3.13

123
Weights and shipping volume TP, TPD, TPE, TPED

Connection Weights Shipping volume


Pump type
D1D D1 S Net [kg] Gross [kg] [m 3]
TP 200-510/4 DN 200 DN 250 975.0 1160.0 3.13
TP 200-560/4 DN 200 DN 250 1075.0 1260.0 3.13
TP 200-620/4 DN 200 DN 250 1210.0 1430.0 4.57
TP 250-270/4 DN 250 DN 300 780.0 965.0 3.13
TP 250-320/4 DN 250 DN 300 910.0 1095.0 3.13
TP 250-370/4 DN 250 DN 300 1025.0 1210.0 3.13
TP 250-490/4 DN 250 DN 300 1225.0 1445.0 4.57
TP 250-540/4 DN 250 DN 300 1360.0 1580.0 4.57
TP 250-600/4 DN 250 DN 300 1515.0 1735.0 4.57
TP 250-660/4 DN 250 DN 300 1655.0 1875.0 4.57
TP 300-590/4 DN 300 DN 350 1935.0 2245.0 5.88
TP 300-670/4 DN 300 DN 350 1930.0 2240.0 5.88
TP 300-750/4 DN 300 DN 350 2130.0 2440.0 5.88
TP 400-470/4 DN 400 DN 500 3700.0 4140.0 10.76
TP 400-510/4 DN 400 DN 500 4100.0 4540.0 10.76
TP 400-540/4 DN 400 DN 500 4200.0 4640.0 10.76
TP 400-670/4 DN 400 DN 500 4400.0 4840.0 10.76
TP 400-720/4 DN 400 DN 500 5000.0 5440.0 10.76
TP 400-760/4 DN 400 DN 500 5200.0 5640.0 10.76

124
Accessories TP, TPD, TPE, TPED

Unions and valves


Cast iron pumps
A union kit consists of two cast iron union tails, two cast
iron union nuts and two EPDM gaskets.

Pump type, union Product


Pressure stage Size
connection number
Rp 3/4 529921
TP, TPE 25 R PN 10 Rp 1 529922
Rp 1 1/4 529924
Rp 1 509921
TP, TPE 32 R PN 10
Rp 1 1/4 509922

A valve kit consists of two brass valves, two brass union


nuts and two EPDM gaskets.
The valve housing is of pressure die-cast brass.

Pump type, valve Product


Pressure stage Size
connection number
Rp 3/4 519805
TP, TPE 25 R PN 10 Rp 1 519806
Rp 1 1/4 519807
TP, TPE 32 R PN 10 Rp 1 1/4 505539

Bronze pumps
A union kit consists of two bronze union tails, two brass
union nuts, and two EPDM gaskets.
The valve housing is of pressure die-cast brass.

Pump type, union Product


Pressure stage Size
connection number
Rp 3/4 529971
TP, TPE 25 R B PN 10
Rp 1 529972
TP, TPE 32 R B PN 10 Rp 1 1/4 509971

A valve kit consists of two brass valves, two brass union


nuts and two EPDM gaskets.
The valve housing is of pressure die-cast brass.

Pump type, valve Product


Pressure stage Size
connection number
Rp 3/4 519805
TP, TPE 25 R B PN 10 Rp 1 519806
Rp 1 1/4 519807
TP, TPE 32 R B PN 10 Rp 1 1/4 505539

125
Accessories TP, TPD, TPE, TPED

Counter flanges
Cast iron pumps
A flange kit consists of two steel flanges, two gaskets of
asbestos-free material IT 200, and the requisite number
of bolts.

Pipework Product
Counter flange Pump type Description Rated pressure
connection number

Threaded 10 bar, EN 1092-2 Rp 1 1/4 539703

ø19
Rp 1¼ 32 mm,
For welding 10 bar, EN 1092-2 539704
nominal
TP, TPE 32
TPD, TPED 32

TM03 0478 5204


Threaded 16 bar, EN 1092-2 Rp 1 1/4 539703

ø78
ø100 32 mm,
Threaded For welding ø140 For welding 16 bar, EN 1092-2 539704
nominal

Threaded 10 bar, EN 1092-2 Rp 1 1/2 539701


ø19
Rp 1½
40 mm,
For welding 10 bar, EN 1092-2 539702
nominal
TM03 0479 5204

TP, TPE 40
TPD, TPED 40
Threaded 16 bar, EN 1092-2 Rp 1 1/2 539701
ø88
ø110
Threaded For welding
ø150
40 mm,
For welding 16 bar, EN 1092-2 539702
nominal

Threaded 10 bar, EN 1092-2 Rp 2 549801


ø19
Rp 2
50 mm,
For welding 10 bar, EN 1092-2 549802
nominal
TM03 0480 5204

TP, TPE 50
TPD, TPED 50
Threaded 16 bar, EN 1092-2 Rp 2 549801
ø102
ø125
Threaded For welding ø165
50 mm,
For welding 16 bar, EN 1092-2 549802
nominal

Threaded 10 bar, EN 1092-2 Rp 2 1/2 559801


ø19
Rp 2½
65 mm,
For welding 10 bar, EN 1092-2 559802
nominal
TM03 0481 5204

TP, TPE 65
TPD, TPED 65
Threaded 16 bar, EN 1092-2 Rp 2 1/2 559801
ø122
ø145
Threaded For welding ø185
65 mm,
For welding 16 bar, EN 1092-2 559802
nominal

126
Accessories TP, TPD, TPE, TPED

Pipework Product
Counter flange Pump type Description Rated pressure
connection number

Threaded 6 bar, EN 1092-2 Rp 3 569902

80 mm,
For welding 6 bar, EN 1092-2 569901
nominal
Rp 3 ø19

Threaded 10 bar, EN 1092-2 Rp 3 569802

TM03 0482 5204


TP, TPE 80
TPD, TPED 80
80 mm,
For welding 10 bar, EN 1092-2 569801
ø138 nominal
ø160
Threaded For welding ø200
Threaded 16 bar, EN 1092-2 Rp 3 569802

80 mm,
For welding 16 bar, EN 1092-2 569801
nominal

Threaded 6 bar, EN 1092-2 Rp 4 579901

100 mm,
For welding 6 bar, EN 1092-2 579902
nominal
Rp 4 ø19

Threaded 10 bar, EN 1092-2 Rp 4 579801


TP, TPE 100
TM03 0483 5204

TPD, TPED
100 100 mm,
For welding 10 bar, EN 1092-2 579802
ø158 nominal
ø180
Threaded For welding ø220
Threaded 16 bar, EN 1092-2 Rp 4 579801

100 mm,
For welding 16 bar, EN 1092-2 579802
nominal

Threaded 10 bar, EN 1092-2 Rp 5 485367


Rp 5 ø19
125 mm,
For welding 10 bar, EN 1092-2 485368
TP, TPE 125 nominal
TM03 0484 5204

TPD, TPED
125
Threaded 16 bar, EN 1092-2 Rp 5 485367
ø188
ø210
Threaded For welding ø250
125 mm,
For welding 16 bar, EN 1092-2 485368
nominal

ø23
150 mm,
For welding 10 bar, EN 1092-2 S1111600
nominal
TP, TPE 150
TM03 0485 5204

TPD, TPED
150
ø212 150 mm,
ø240 For welding 16 bar, EN 1092-2 S1111600
nominal
For welding ø285

127
Accessories TP, TPD, TPE, TPED

Bronze pumps
A flange kit consists of two bronze flanges, two gaskets
of asbestos-free material IT 200, and the requisite
number of bolts.

Pipework Product
Counter flange Pump type Description Rated pressure
connection number

Threaded 10 bar, EN 1092-2 Rp 1 1/4 96427029

ø19
Rp 1¼ For welding 10 bar, EN 1092-2
32 mm,
96427030
nominal
TP, TPE 32 B

TM03 0478 5204


Threaded 16 bar, EN 1092-2 Rp 1 1/4 96427029

ø78
ø100 32 mm,
Threaded For welding ø140 For welding 16 bar, EN 1092-2 96427030
nominal

Threaded 10 bar, EN 1092-2 Rp 1 1/2 539711


ø19
Rp 1½
40 mm,
For welding 10 bar, EN 1092-2 539712
nominal
TM03 0479 5204

TP, TPE 40 B

Threaded 16 bar, EN 1092-2 Rp 1 1/2 539711


ø88
ø110
Threaded For welding
ø150
40 mm,
For welding 16 bar, EN 1092-2 539712
nominal

ø19
Rp 2
Threaded 10 bar, EN 1092-2 Rp 2 549811
TM03 0480 5204

TP, TPE 50 B

ø102 50 mm,
ø125
For welding 10 bar, EN 1092-2 549812
Threaded For welding nominal
ø165

ø19
Rp 2½
Threaded 10 bar, EN 1092-2 Rp 2 1/2 559811
TM03 0481 5204

TP, TPE 65 B

ø122 65 mm,
ø145
For welding 10 bar, EN 1092-2 559812
Threaded For welding nominal
ø185

Threaded 6 bar, EN 1092-2 Rp 3 96405735


Rp 3 ø19
80 mm,
For welding 6 bar, EN 1092-2 569911
nominal
TM03 0482 5204

TP, TPE 80 B

Threaded 10 bar, EN 1092-2 Rp 3 569812


ø138
ø160
Threaded For welding ø200
80 mm,
For welding 10 bar, EN 1092-2 569811
nominal

Rp 4 ø19
Threaded 6 bar, EN 1092-2 Rp 4 96405737
TM03 0485 5204

TP, TPE 100 B

ø158
ø180 Threaded 10 bar, EN 1092-2 Rp 4 96405738
Threaded For welding ø220

128
Accessories TP, TPD, TPE, TPED

Base plates TP, TPE Series 300

Note: Base plates are supplied as standard with TP, Product


Pump type Hexagon head screws
TPD, TPE, TPED pumps with 11 kW motors and above. number
TP, TPE 80-240/4
TP, TPE Series 100 and 200 TP, TPE 80-270/4
TP, TPE 80-340/4
TP, TPE 100-250/2
Product TP, TPE 100-310/2
Pump type Hexagon head screws
number TP, TPE 100-360/2
TP, TPE 32 TP, TPE 100-390/2 2 x M16 x 30 mm 96536246
TP, TPE 40 TP, TPE 100-480/2
TP, TPE 50 TP, TPE 100-xx/4
2 x M12 x 20 mm 96405915 TP, TPE 125-xx/4
TP 65-60/2
TP, TPE 65-120/2 TP, TPE 150-xx/4
TP 65-180/2 TP, TPE 125-xx/6
TP, TPE 150-xx/6
TP 65-30/4
TP, TPE 65-60/4
2 x M16 x 30 mm 96405914
TP, TPE 80 Product
Drawing
TP, TPE 100 number
Except TPE 32-90.
380
Product 290
Drawing 35
number 230

235
195 35
4xø14
2xø18 96536246

TM02 8869 1004


290

4xø18
2xø14 96405915
160
195
80

2xø14
96405914
TM00 9835 0497

2xø18
4xø14 TPD, TPED Series 300
120
200 Product
Pump type Hexagon head screws
number
TP, TPE Series 300 TPD, TPED 32
TPD, TPED 40
Product TPD, TPED 50
Pump type Hexagon head screws TPD, TPED 65
number
TPD, TPED 80-xx/2
TP, TPE 32
TPD, TPED 80-70/4
TP, TPE 40
TPD, TPED 80-90/4 4 x M16 x 30 mm 96489381
TP, TPE 50
TPD, TPED 80-110/4
TP, TPE 65
TPD, TPED 80-150/4
TP, TPE 80-xx/2
TPD, TPED 80-170/4
TP, TPE 80-70/4
TPD, TPED 100-160/2
TP, TPE 80-90/4 2 x M16 x 30 mm 00485031
TPD, TPED 100-200/2
TP, TPE 80-110/4
TPD, TPED 100-240/2
TP, TPE 80-150/4
TP, TPE 80-170/4
TP, TPE 100-160/2 Product
Drawing
TP, TPE 100-200/2 number
TP, TPE 100-240/2

Product
Drawing
number
35

235
195 35 2xø18
2xø14
175 96489381
TM02 5336 2602
47
67

300
00485031 2xø14
330
195
96

TM00 3755 2602

2xø18

4xø14
144

129
Accessories TP, TPD, TPE, TPED

TPD, TPED Series 300

Product
Pump type Hexagon head screws
number
TPD, TPED 100-250/2
TPD, TPED 100-310/2
TPD, TPED 100-360/2
TPD, TPED 100-390/2
TPD, TPED 100-70/4 4 x M16 x 30 mm 96536247
TPD, TPED 100-90/4
TPD, TPED 100-110/4
TPD, TPED 100-130/4
TPD, TPED 100-170/4

Product
Drawing
number
35

230 2xø18 96536247


TM02 8870 1004
47
67

355
2xø14
385

TPD, TPED Series 300

Product
Pump type Hexagon head screws
number
TPD, TPED 80-240/4
TPD, TPED 80-270/4
TPD, TPED 80-340/4
TPD, TPED 100-200/4
TPD, TPED 100-250/4
4 x M16 x 30 mm 96536248
TPD, TPED 100-330/4
TPD, TPED 100-370/4
TPD, TPED 100-410/4
TPD, TPED 125-xx/4
TPD, TPED 150-xx/4

Product
Drawing
number
35

350
300 4xø18 96536248
TM02 8871 1004
47
67

475
2xø14
505

130
Accessories TP, TPD, TPE, TPED

Blanking flanges
Normally used with twin-head pumps.

TM00 6360 3495

TPD, TPED 2-pole

Pump type 00545048 00565055 96495694 96495695 96495696 96525962 96525963 96525964
TPD, TPED 32-60/2 z
TPD, TPED 32-120/2 z
TPD, TPED 32-150/2 z
TPD, TPED 32-180/2 z
TPD, TPED 32-230/2 z
TPD, TPED 32-200/2 z
TPD, TPED 32-250/2 z
TPD, TPED 32-320/2 z
TPD, TPED 32-380/2 z
TPD, TPED 32-460/2 z
TPD, TPED 32-580/2 z
TPD, TPED 40-60/2 z
TPD, TPED 40-120/2 z
TPD, TPED 40-190/2 z
TPD, TPED 40-230/2 z
TPD, TPED 40-270/2 z
TPD, TPED 40-240/2 z
TPD, TPED 40-300/2 z
TPD, TPED 40-360/2 z
TPD, TPED 40-470/2 z
TPD, TPED 40-580/2 z
TPD, TPED 50-60/2 z
TPD, TPED 50-120/2 z
TPD, TPED 50-180/2 z
TPD, TPED 50-160/2 z
TPD, TPED 50-190/2 z
TPD, TPED 50-240/2 z
TPD, TPED 50-290/2 z
TPD, TPED 50-360/2 z
TPD, TPED 50-430/2 z
TPD, TPED 50-440/2 z
TPD, TPED 50-570/2 z
TPD, TPED 50-710/2 z
TPD, TPED 50-830/2 z
TPD, TPED 50-900/2 z

131
Accessories TP, TPD, TPE, TPED

Pump type 00545048 00565055 96495694 96495695 96495696 96525962 96525963 96525964
TPD, TPED 65-60/2 z
TPD, TPED 65-120/2 z
TP, TPD 65-180/2 z
TPD, TPED 65-190/2 z
TPD, TPED 65-230/2 z
TPD, TPED 65-260/2 z
TPD, TPED 65-340/2 z
TPD, TPED 65-410/2 z
TPD, TPED 65-340/2 z
TPD, TPED 65-410/2 z
TPD, TPED 65-460/2 z
TPD, TPED 65-550/2 z
TPD, TPED 65-660/2 z
TPD, TPED 65-720/2 z
TPD 65-930/2 z
TPD, TPED 80-120/2 z
TPD, TPED 80-140/2 z
TPD, TPED 80-180/2 z
TPD, TPED 80-210/2 z
TPD, TPED 80-240/2 z
TPD, TPED 80-250/2 z
TPD, TPED 80-330/2 z
TPD, TPED 80-400/2 z
TPD, TPED 80-520/2 z
TPD, TPED 80-570/2 z
TP, TPD 80-700/2 z
TPD, TPED 100-120/2 z
TPD, TPED 100-160/2 z
TPD, TPED 100-200/2 z
TPD, TPED 100-240/2 z
TPD, TPED 100-250/2 z
TPD, TPED 100-310/2 z
TPD, TPED 100-360/2 z
TPD, TPED 100-390/2 z
TP, TPD 100-480/2 z

132
Accessories TP, TPD, TPE, TPED

TPD, TPED 4-pole

Pump type 00545048 00565055 96495694 96495695 96495696 96525962 96525963 96525964
TPD, TPED 32-30/4 z
TPD, TPED 32-40/4 z
TPD, TPED 32-60/4 z
TPD, TPED 32-80/4 z
TPD, TPED 32-100/4 z
TPD, TPED 32-120/4 z
TPD, TPED 40-30/4 z
TPD, TPED 40-90/4 z
TPD, TPED 40-100/4 z
TPD, TPED 40-130/4 z
TPD, TPED 40-160/4 z
TPD, TPED 50-30/4 z
TPD, TPED 50-60/4 z
TPD, TPED 50-90/4 z
TPD, TPED 50-110/4 z
TPD, TPED 50-130/4 z
TPD, TPED 50-160/4 z
TPD, TPED 50-190/4 z
TPD, TPED 50-230/4 z
TPD, TPED 65-30/4 z
TPD, TPED 65-60/4 z
TPD, TPED 65-90/4 z
TPD, TPED 65-110/4 z
TPD, TPED 65-130/4 z
TPD, TPED 65-150/4 z
TPD, TPED 65-170/4 z
TPD, TPED 65-240/4 z
TPD, TPED 80-30/4 z
TPD, TPED 80-60/4 z
TPD, TPED 80-70/4 z z
TPD, TPED 80-90/4 z
TPD, TPED 80-110/4 z
TPD, TPED 80-150/4 z
TPD, TPED 80-170/4 z
TPD, TPED 80-240/4 z
TPD, TPED 80-270/4 z
TPD, TPED 80-340/4 z
TPD, TPED 100-30/4 z
TPD, TPED 100-60/4 z
TPD, TPED 100-70/4 z
TPD, TPED 100-90/4 z
TPD, TPED 100-110/4 z
TPD, TPED 100-130/4 z
TPD, TPED 100-170/4 z
TPD, TPED 100-200/4 z
TPD, TPED 100-250/4 z
TPD, TPED 100-330/4 z
TPD, TPED 100-370/4 z
TPD, TPED 100-410/4 z
TPD, TPED 125-110/4 z
TPD, TPED 125-130/4 z
TPD, TPED 125-160/4 z
TPD, TPED 125-210/4 z
TPD, TPED 125-250/4 z
TPD, TPED 125-320/4 z
TPD, TPED 125-360/4 z
TPD 125-420/4 z

133
Accessories TP, TPD, TPE, TPED

Pump type 00545048 00565055 96495694 96495695 96495696 96525962 96525963 96525964
TPD, TPED 150-130/4 z
TPD, TPED 150-160/4 z
TPD, TPED 150-200/4 z
TPD, TPED 150-220/4 z
TPD, TPED 150-250/4 z

TPD 6-pole

Pump type 00545048 00565055 96495694 96495695 96495696 96525962 96525963 96525964
TP, TPD 125-60/6 z
TP, TPD 125-70/6 z
TP, TPD 125-90/6 z
TP, TPD 125-110/6 z
TP, TPD 125-140/6 z
TP, TPD 125-170/6 z
TP, TPD 150-60/6 z
TP, TPD 150-70/6 z
TP, TPD 150-90/6 z
TPD 150-110/6 z

134
Accessories TP, TPD, TPE, TPED

Insulating kits Product numbers of insulating kits

Insulating kits are only available for TP, TPE Series 200 Single-head TP, TPE Series 200 pumps
pumps. An insulating kit consists of two or three Pump type Product number
insulating covers made of expanded polypropylene TP, TPE 32-30/4 96405871
(EPP). TP, TPE 32-40/4 96405880
TP, TPE 32-60/2 96405873
The insulating kit is tailored to the individual pump TP, TPE 32-60/4 96405880
model and has an insulating thickness corresponding to TP, TPE 32-120/2 96405873
the nominal diameter of the pump. TP, TPE 32-150/2 96405880
TP, TPE 32-180/2 96405880
The thermal conductivity of EPP is very low
TP, TPE 32-230/2 96405880
(0.04 W/m °C), i.e. the insulating property is very good.
TP, TPE 40-30/4 96405874
The insulating kit encloses the entire pump housing. TP, TPE 40-60/4 96405875
TP, TPE 40-60/2 96405876
TP, TPE 40-90/4 96405880
TP, TPE 40-120/2 96405877
TP, TPE 40-180/2 96405878
TP, TPE 40-190/2 96405880
TP, TPE 40-230/2 96405880
TM00 8095 2496

TP, TPE 40-270/2 96405880


TP, TPE 50-30/4 96405879
TP, TPE 50-60/2 96405881
TP, TPE 50-60/4 96405880
TP, TPE 50-120/2 96405882
Fig. 38 Insulating kit
TP, TPE 50-180/2 96405883
TP, TPE 65-30/4 96405884
TP, TPE 65-60/2 96405886
TP, TPE 65-60/4 96405885
TP, TPE 65-120/2 96405887
TP, TPE 65-180/2 96405888
TP, TPE 80-30/4 96405889
TP, TPE 80-60/4 96405890
TP, TPE 80-120/2 96405891
TP, TPE 100-30/4 96405892
TP, TPE 100-60/4 96405892
TP, TPE 100-120/2 96408407

135
Accessories TP, TPD, TPE, TPED

Sensors
Accessory Type Supplier Measuring range Product number
SITRANS F M MAGFLO 3
Flowmeter Siemens 1 - 5 m /h (DN 25) ID8285
MAG 5100 W
SITRANS F M MAGFLO
Flowmeter Siemens 3 - 10 m3/h (DN 40) ID8286
MAG 5100 W
SITRANS F M MAGFLO
Flowmeter Siemens 6 - 30 m3/h DN 65) ID8287
MAG 5100 W
SITRANS F M MAGFLO
Flowmeter Siemens 20 - 75 m3/h (DN 100) ID8288
MAG 5100 W
Temperature sensor TTA (0) 25 Carlo Gavazzi 0 °C to +25 °C 96432591
Temperature sensor TTA (-25) 25 Carlo Gavazzi –25 °C to +25 °C 96430194
Temperature sensor TTA (50) 100 Carlo Gavazzi 50 °C to +100 °C 96432592
Temperature sensor TTA (0) 150 Carlo Gavazzi 0 °C to +150 °C 96430195
Protecting tube
Carlo Gavazzi 96430201
∅9 x 50 mm
Accessory for temperature sensor.
Protecting tube
All with ½ RG connection. Carlo Gavazzi 96430202
∅9 x 100 mm
Cutting ring bush Carlo Gavazzi 96430203
tmg
Temperature sensor, ambient temperature WR 52 –50 °C to +50 °C ID8295
(DK: Plesner)
Differential temperature sensor ETSD Honsberg 0 °C to +20 °C 96409362
Differential temperature sensor ETSD Honsberg 0 °C to +50 °C 96409363
Note: All sensors have 4-20 mA output signal.

Sensors for boosting applications

Danfoss pressure sensor kit Pressure range Product number


0 - 2.5 bar 96478188
0 - 4 bar 91072075
• Connection: G 1/2 A (DIN 16288 - B6kt)
0 - 6 bar 91072076
• Electrical connection: plug (DIN 43650)
0 - 10 bar 91072077
0 - 16 bar 91072078
0 - 2.5 bar 405159
• Pressure sensor, type MBS 3000, with 2 m screened cable 0 - 4 bar 405160
Connection: G 1/4 A (DIN 16288 - B6kt)
0 - 6 bar 405161
• 5 cable clips (black)
• Fitting instructions PT (00400212) 0 - 10 bar 405162
0 - 16 bar 405163

Sensors for circulation applications

Grundfos differential pressure sensor, DPI Pressure range Product number

0 - 0.6 bar 96611522


• 1 sensor incl. 0.9 m screened cable (7/16" connections)
• 1 original DPI bracket (for wall mounting)
0 - 1.0 bar 96611523
• 1 Grundfos bracket (for mounting on motor)
• 2 M4 screws for mounting of sensor on bracket
• 1 M6 screw (self-cutting) for mounting on MGE 90/100 0 - 1.6 bar 96611524
• 1 M8 screw (self-cutting) for mounting on MGE 112/132
• 1 M10 screw (self-cutting) for mounting on MGE 160 0 - 2.5 bar 96611525
• 1 M12 screw (self-cutting) for mounting on MGE 180
• 3 capillary tubes (short/long) 0 - 4.0 bar 96611526
• 2 fittings (1/4" - 7/16")
• 5 cable clips (black)
0 - 6.0 bar 96611527
• Installation and operating instructions
• Service kit instruction
0 - 10 bar 96611550

Fitting kit for TPED with two sensors


96491010

Select the differential pressure sensor so that the maximum pressure of the sensor is higher than the maximum differential pressure of the pump.

136
Accessories TP, TPD, TPE, TPED

Potentiometer EMC filter


Potentiometer for setpoint setting and start/stop of the
EMC (electromagnetic compatibility to EN 61800-3)
pump.
Motor [kW]
Emission/immunity
Product Product number 2-pole 4-pole
External potentiometer with cabinet for wall 0.37 0.37
625468
mounting.
0.55 0.55
0.75 0.75
R100 Emission:
Motors may be installed in residential areas
1.1 1.1
R100 is used for wireless communication. (first environment), unrestricted distribution,
1.5 1.5 corresponding to CISPR11, group 1, class B.
Communication takes place by means of infrared light. 2.2 2.2
Immunity:
3.0 3.0 Motors fulfil the requirements for both the first
Product Product number and second environment.
4.0 4.0
R100 625333
5.5 –

G10-LON interface 7.5 –


– 5.5
The G10-LON interface is used in connection with data Emission:
– 7.5 The motors are category C3, corresponding to
transmission between a Locally Operating Network CISPR11, group 2, class A, and may be
11 11
(LON) and electronically controlled Grundfos pumps installed in industrial areas (second
15 15 environment).
applying the Grundfos bus-protocol GENIbus. If equipped with an external Grundfos EMC
18.5 18.5
filter, the motors are category C2,
22 – corresponding to CISPR11, group 1, class A,
Product Product number
and may be installed in residential areas
G10-LON interface 00605726 (first environment).

TM02 9198 1203


Fig. 39 EMC filter

The EMC filter for residential areas is available as a


complete kit ready for installation.

Product Product number


EMC-filter (TPE 5.5 kW and 7.5 kW, 4-pole) 96041047
EMC-filter (TPE 11-22 kW) 96478309

137
Minimum inlet pressure - NPSH TP, TPD, TPE, TPED

To ensure optimum and noiseless operation we


recommend the minimum inlet pressure values shown
on page 139 to 141.
A minimum inlet pressure is required to avoid pressure
drop that may cause cavitation.
The minimum inlet pressure (ps) in bar relative
(pressure gauge value on the pump suction side) can
be calculated using the following formula.
Note: Calculation of the minimum inlet pressure should
be based on the maximum required flow.

1
p ≥ ⎛⎝ ( NPSH + H ) × ρ × g – ⎛⎝ --- × ρ × c ⎞⎠ ⎞⎠ × 0.00001 – p + p [ bar relative ]
2
S R S 2 b d

ps = Minimum inlet pressure in bar.


NPSHR = The required Net Positive Suction Head Temp. Pd
in metres head. [˚C] [bar]
(To be read from the NPSH curve at the 150 4.76
highest flow the pump will be delivering). c
Ps
140 3.61
Hs = Safety margin = minimum 0.5 metres 130 2.70
head.
120 1.99
Note: A safety margin of 0.5 metres
110 1.43
prevents pressure drop. NPSH
ρ = Density of the pumped liquid measured in 100 1.01

kg/m3. 90 0.70

g = Gravitational acceleration measured in 80 0.47


m/s. For estimated calculations use the 70 0.31
value 9.81 m/s2.

TM02 8491 0204 - TM03 0371 5004


60 0.20
c = Flow velocity of the pumped liquid at the
50 0.12
pressure gauge. Insert the flow velocity
40 0.07
as the unit [m/s].
(See individual curve charts from 30 0.04

page 49). 20 0.02


pb = Barometric pressure in bar. 10 0.01
(Set the barometric pressure to 0.97 bar) 0
Note: Only occasionally is the pressure
as high as 1 bar; also this value is at sea Fig. 40 Minimum inlet pressure

level.
pd = Vapour pressure in bar. (See fig. 40).

138
Minimum inlet pressure - NPSH TP, TPD, TPE, TPED

TP, TPD 2-pole, PN 6, 10, 16


p [bar]
p [bar] Pump type
Pump type 20 °C 60 °C 90 °C 110 °C 120 °C 140 °C
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C
TP, TPD 80-120/2 1.2 1.4 1.9 2.7 3.2 4.9
TP 25-50/2 R 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 80-140/2 0.1 0.2 0.7 1.4 1.9 3.6
TP 25-90/2 R 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 80-180/2 0.1 0.1 0.3 1.1 1.6 3.2
TP 32-50/2 R 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 80-210/2 0.1 0.1 0.4 1.1 1.7 3.3
TP 32-90/2 R 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 80-240/2 0.1 0.1 0.6 1.3 1.8 3.5
TP, TPD 32-60/2 0.1 0.1 0.2 1.0 1.5 3.2
TP, TPD 80-250/2 0.1 0.3 0.8 1.6 2.1 3.7
TP, TPD 32-120/2 0.1 0.2 0.7 1.5 2.0 3.7
TP, TPD 80-330/2 0.1 0.2 0.7 1.4 2.0 3.6
TP, TPD 32-150/2 0.1 0.3 0.8 1.6 2.1 3.8
TP, TPD 80-400/2 0.2 0.4 0.9 1.7 2.2 3.8
TP, TPD 32-180/2 0.5 0.7 1.2 2.0 2.5 4.2
TP, TPD 80-520/2 0.1 0.2 0.7 1.4 1.9 3.6
TP, TPD 32-230/2 0.7 0.9 1.4 2.2 2.7 4.4
TP, TPD 80-570/2 0.1 0.3 0.8 1.6 2.1 3.7
TP, TPD 32-200/2 0.1 0.1 0.2 0.9 1.5 3.1
TP, TPD 80-700/2 0.6 0.8 1.3 2.1 2.6 4.2
TP, TPD 32-250/2 0.1 0.1 0.3 1.0 1.6 3.2
TP, TPD 100-120/2 1.9 2.1 2.6 3.4 3.9 5.6
TP, TPD 32-320/2 0.1 0.1 0.6 1.3 1.9 3.5
TP, TPD 100-160/2 0.1 0.1 0.6 1.3 1.9 3.5
TP, TPD 32-380/2 0.1 0.2 0.7 1.4 2.0 3.6
TP, TPD 100-200/2 0.1 0.1 0.4 1.2 1.7 3.3
TP, TPD 32-460/2 0.1 0.2 0.7 1.4 1.9 3.6
TP, TPD 100-240/2 0.1 0.1 0.5 1.3 1.8 3.4
TP, TPD 32-580/2 0.2 0.4 0.9 1.6 2.2 3.8
TP, TPD 100-250/2 0.6 0.8 1.3 2.0 2.5 4.2
TP 40-50/2 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 100-310/2 0.6 0.8 1.3 2.0 2.6 4.2
TP, TPD 40-60/2 0.1 0.1 0.5 1.2 1.8 3.5
TP, TPD 100-360/2 0.6 0.8 1.3 2.0 2.6 4.2
TP 40-90/2 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 100-390/2 1.0 1.2 1.7 2.4 3.0 4.6
TP, TPD 40-120/2 0.1 0.1 0.4 1.2 1.7 3.4
TP, TPD 100-480/2 1.5 1.7 2.2 2.9 3.5 5.1
TP 40-180/2 0.1 0.2 0.7 1.5 2.0 3.7
TP, TPD 40-190/2 0.1 0.3 0.8 1.6 2.1 3.8
TP, TPD 40-230/2 0.7 0.9 1.4 2.2 2.7 4.4
TP, TPD 40-270/2 0.7 0.9 1.4 2.2 2.7 4.4
TP, TPD 40-240/2 0.1 0.1 0.4 1.1 1.7 3.3
TP, TPD 40-300/2 0.1 0.1 0.4 1.1 1.6 3.3
TP, TPD 40-360/2 0.2 0.4 0.9 1.6 2.1 3.8
TP, TPD 40-470/2 0.1 0.1 0.4 1.1 1.6 3.3
TP, TPD 40-580/2 0.2 0.4 0.9 1.6 2.1 3.8
TP, TPD 50-60/2 0.1 0.1 0.4 1.1 1.7 3.4
TP, TPD 50-120/2 0.1 0.2 0.7 1.5 2.0 3.7
TP, TPD 50-180/2 0.1 0.2 0.7 1.4 2.0 3.7
TP, TPD 50-160/2 0.1 0.1 0.1 0.8 1.4 3.0
TP, TPD 50-190/2 0.1 0.1 0.1 0.9 1.4 3.0
TP, TPD 50-240/2 0.1 0.1 0.1 0.8 1.4 3.0
TP, TPD 50-290/2 0.1 0.1 0.2 0.9 1.5 3.1
TP, TPD 50-360/2 0.1 0.1 0.2 1.0 1.5 3.1
TP, TPD 50-430/2 0.1 0.1 0.4 1.1 1.6 3.2
TP, TPD 50-440/2 0.1 0.1 0.4 1.1 1.6 3.3
TP, TPD 50-570/2 0.1 0.3 0.8 1.6 2.1 3.7
TP, TPD 50-710/2 0.6 0.8 1.3 2.0 2.6 4.2
TP, TPD 50-830/2 0.5 0.7 1.2 2.0 2.5 4.1
TP, TPD 50-900/2 1.0 1.2 1.7 2.4 3.0 4.6
TP, TPD 65-60/2 0.1 0.3 0.8 1.5 2.1 3.8
TP, TPD 65-120/2 0.5 0.7 1.2 2.0 2.5 4.2
TP, TPD 65-180/2 0.3 0.5 1.0 1.8 2.3 4.0
TP, TPD 65-190/2 0.1 0.1 0.1 0.7 1.3 2.9
TP, TPD 65-230/2 0.1 0.1 0.1 0.8 1.4 3.0
TP, TPD 65-260/2 0.1 0.1 0.1 0.8 1.4 3.0
TP, TPD 65-340/2 0.1 0.1 0.2 0.9 1.4 3.1
TP, TPD 65-410/2 0.1 0.1 0.2 0.9 1.4 3.1
TP, TPD 65-460/2 0.1 0.1 0.2 1.0 1.5 3.1
TP, TPD 65-550/2 0.1 0.1 0.3 1.0 1.6 3.2
TP, TPD 65-660/2 0.1 0.1 0.4 1.1 1.6 3.3
TP, TPD 65-720/2 0.1 0.1 0.6 1.3 1.9 3.5
TP, TPD 65-930/2 0.6 0.8 1.3 2.0 2.6 4.2

139
Minimum inlet pressure - NPSH TP, TPD, TPE, TPED

TP, TPD 4-pole, PN 6, 10, 16


p [bar]
p [bar] Pump type
Pump type 20 °C 60 °C 90 °C 110 °C 120 °C 140 °C
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C
TP, TPD 125-420/4 0.1 0.2 0.7 1.4 2.0 3.6
TP, TPD 32-30/4 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 150-130/4 0.1 0.1 0.4 1.1 1.6 3.3
TP, TPD 32-40/4 0.1 0.1 0.1 0.9 1.4 3.1
TP, TPD 150-160/4 0.1 0.1 0.4 1.1 1.7 3.3
TP, TPD 32-60/4 0.1 0.1 0.3 1.1 1.6 3.3
TP, TPD 150-200/4 0.1 0.1 0.4 1.1 1.7 3.3
TP, TPD 32-80/4 0.1 0.1 0.1 0.5 1.1 2.7
TP, TPD 150-220/4 0.1 0.1 0.5 1.2 1.8 3.4
TP, TPD 32-100/4 0.1 0.1 0.1 0.5 1.1 2.7
TP, TPD 150-250/4 0.1 0.1 0.6 1.3 1.9 3.5
TP, TPD 32-120/4 0.1 0.1 0.1 0.6 1.1 2.7
TP 150-260/4 0.6 0.8 1.3 2.0 2.5 4.2
TP, TPD 40-30/4 0.1 0.1 0.2 0.9 1.5 3.2
TP 150-280/4 0.6 0.8 1.3 2.1 2.6 4.2
TP 40-60/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-340/4 0.9 1.1 1.6 2.3 2.9 4.5
TP, TPD 40-90/4 0.1 0.1 0.3 1.0 1.6 3.3
TP 150-390/4 2.0 2.2 2.7 3.5 4.0 5.6
TP, TPD 40-100/4 0.1 0.1 0.2 0.9 1.5 3.1
TP 200-180/4 1.4 1.6 2.1 2.8 3.3 5.0
TP, TPD 40-130/4 0.1 0.1 0.1 0.7 1.2 2.8
TP 200-220/4 1.1 1.3 1.8 2.6 3.1 4.7
TP, TPD 40-160/4 0.1 0.1 0.2 0.9 1.5 3.1
TP 200-250/4 1.1 1.3 1.8 2.5 3.1 4.7
TP, TPD 50-30/4 0.1 0.1 0.1 0.9 1.4 3.1
TP 200-270/4 1.6 1.8 2.3 3.0 3.6 5.2
TP, TPD 50-60/4 0.1 0.1 0.2 0.9 1.5 3.2
TP 200-320/4 1.6 1.8 2.3 3.1 3.4 5.2
TP, TPD 50-90/4 0.1 0.1 0.1 0.6 1.4 2.8
TP 200-330/4 1.1 1.3 1.8 2.5 3.1 4.7
TP, TPD 50-110/4 0.1 0.1 0.1 0.6 1.4 2.8
TP 200-360/4 1.2 1.4 1.9 2.6 3.1 4.8
TP, TPD 50-130/4 0.1 0.1 0.1 0.6 1.2 2.8
TP 200-400/4 1.3 1.5 2.0 2.8 3.3 4.9
TP, TPD 50-160/4 0.1 0.1 0.1 0.7 1.3 2.9
TP 200-410/4 2.3 2.5 3.0 3.7 4.3 5.9
TP, TPD 50-190/4 0.1 0.1 0.1 0.9 1.4 3.0
TP 200-470/4 1.4 1.6 2.1 2.8 3.4 5.0
TP, TPD 50-230/4 0.1 0.1 0.1 1.0 1.5 3.2
TP 200-530/4 1.6 1.8 2.3 3.0 3.6 5.2
TP, TPD 65-30/4 0.1 0.2 0.7 1.5 2.0 3.7
TP 200-590/4 1.7 1.9 2.4 3.2 3.7 5.3
TP, TPD 65-60/4 0.2 0.4 0.9 1.6 2.2 3.9
TP 200-660/4 2.9 3.1 3.6 4.3 4.9 6.5
TP, TPD 65-90/4 0.1 0.1 0.1 0.6 1.1 2.7
TP 250-280/4 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 65-110/4 0.1 0.1 0.1 0.6 1.1 2.7
TP 250-310/4 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 65-130/4 0.1 0.1 0.1 0.6 1.1 2.8
TP 250-390/4 0.1 0.1 0.1 0.8 1.4 3.1
TP, TPD 65-150/4 0.1 0.1 0.1 0.6 1.2 2.8
TP, TPD 65-170/4 0.1 0.1 0.1 0.6 1.2 2.8
TP, TPD 65-240/4 0.1 0.1 0.1 0.8 1.3 2.9
TP, TPD 6-pole, PN 16
TP, TPD 80-30/4 0.8 1.0 1.5 2.2 2.8 4.5
p [bar]
TP, TPD 80-60/4 0.8 1.0 1.5 2.3 2.8 4.5 Pump type
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C
TP, TPD 80-70/4 0.1 0.1 0.1 0.8 1.3 2.9
TP, TPD 125-60/6 0.1 0.1 0.1 0.7 1.2 2.8
TP, TPD 80-90/4 0.1 0.1 0.1 0.7 1.2 2.8
TP, TPD 125-70/6 0.1 0.1 0.1 0.7 1.3 2.9
TP, TPD 80-110/4 0.1 0.1 0.1 0.8 1.4 3.0
TP, TPD 125-90/6 0.1 0.1 0.1 0.7 1.2 2.9
TP, TPD 80-150/4 0.1 0.1 0.1 0.8 1.3 3.0
TP, TPD 125-110/6 0.1 0.1 0.1 0.8 1.3 2.9
TP, TPD 80-170/4 0.1 0.1 0.2 1.0 1.5 3.1
TP, TPD 125-140/6 0.1 0.1 0.1 0.7 1.3 2.9
TP, TPD 80-240/4 0.1 0.1 0.3 1.0 1.5 3.2
TP, TPD 125-170/6 0.1 0.1 0.1 0.8 1.4 3.0
TP, TPD 80-270/4 0.1 0.1 0.2 0.9 1.5 3.1
TP, TPD 150-60/6 0.1 0.1 0.1 0.7 1.3 2.9
TP, TPD 80-340/4 0.1 0.1 0.3 1.1 1.6 3.2
TP, TPD 150-70/6 0.1 0.1 0.1 0.7 1.3 2.9
TP, TPD 100-30/4 0.8 1.0 1.5 2.2 2.8 4.5
TP, TPD 150-90/6 0.1 0.1 0.1 0.8 1.3 2.9
TP, TPD 100-60/4 0.6 0.8 1.3 2.0 2.6 4.3
TP, TPD 150-110/6 0.1 0.1 0.1 0.8 1.3 3.0
TP, TPD 100-70/4 0.1 0.1 0.1 0.8 1.3 3.0
TP, TPD 100-90/4 0.1 0.1 0.1 0.9 1.4 3.0
TP, TPD 100-110/4 0.1 0.1 0.2 1.0 1.5 3.1
TP Series 400, 2-pole, PN 25
TP, TPD 100-130/4 0.1 0.1 0.6 1.3 1.9 3.5
p [bar]
TP, TPD 100-170/4 0.3 0.5 1.0 1.7 2.3 3.9 Pump type
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C
TP, TPD 100-200/4 0.1 0.1 0.5 1.2 1.8 3.4
TP 100-620/2 0.2 0.4 0.9 1.6 2.2 3.9
TP, TPD 100-250/4 0.1 0.2 0.7 1.4 2.0 3.6
TP 100-700/2 0.1 0.2 0.7 1.5 2.0 3.7
TP, TPD 100-330/4 0.3 0.5 1.0 1.7 2.3 3.9
TP 100-820/2 0.1 0.2 0.7 1.4 2.0 3.7
TP, TPD 100-370/4 0.3 0.5 1.0 1.7 2.3 3.9
TP 100-960/2 0.1 0.2 0.7 1.4 2.0 3.7
TP, TPD 100-410/4 0.5 0.7 1.2 1.9 2.5 4.1
TP 100-1050/2 0.1 0.1 0.6 1.3 1.9 3.6
TP, TPD 125-110/4 0.1 0.1 0.1 0.9 1.4 3.0
TP 100-1180/2 0.1 0.2 0.7 1.5 2.0 3.7
TP, TPD 125-130/4 0.1 0.1 0.2 0.9 1.5 3.1
TP 100-1400/2 0.1 0.2 0.7 1.5 2.0 3.7
TP, TPD 125-160/4 0.1 0.1 0.3 1.0 1.5 3.2
TP 100-1530/2 0.1 0.2 0.7 1.4 2.0 3.7
TP, TPD 125-210/4 0.1 0.1 0.3 1.0 1.6 3.2
TP 100-1680/2 0.1 0.1 0.6 1.4 1.9 3.6
TP, TPD 125-250/4 0.1 0.1 0.4 1.1 1.7 3.3
TP, TPD 125-320/4 0.1 0.1 0.3 1.0 1.6 3.2
TP, TPD 125-360/4 0.1 0.1 0.4 1.2 1.7 3.3

140
Minimum inlet pressure - NPSH TP, TPD, TPE, TPED

TP Series 400, 4-pole, PN 25


p [bar]
Pump type
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C
TP 100-190/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 100-220/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 100-260/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 100-270/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 100-320/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 100-380/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 100-420/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 125-150/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 125-200/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 125-240/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 125-280/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 125-310/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 125-370/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 125-430/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-240/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-270/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-320/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-350/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-430/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-530/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 150-650/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-270/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-280/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-380/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-420/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-450/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-510/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-560/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 200-620/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 250-270/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 250-320/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 250-370/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 250-490/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 250-540/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 250-600/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 250-660/4 0.1 0.1 0.1 0.8 1.4 3.1
TP 300-590/4 0.4 0.6 1.1 1.8 2.4 4.1
TP 300-670/4 0.4 0.6 1.1 1.8 2.4 4.1
TP 300-750/4 0.3 0.5 1.0 1.8 2.3 4.0
TP 400-470/4 0.1 0.3 0.8 1.6 2.1 3.8
TP 400-510/4 0.1 0.3 0.8 1.6 2.1 3.8
TP 400-540/4 0.1 0.3 0.8 1.5 2.1 3.8
TP 400-670/4 0.6 0.8 1.3 2.1 2.6 4.3
TP 400-720/4 0.6 0.8 1.3 2.1 2.6 4.3
TP 400-760/4 0.6 0.8 1.3 2.0 2.6 4.3

141
Further product documentation TP, TPD, TPE, TPED

WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.

Catalogue

This section is based on fields of application and pump types, and


contains
• technical data
• curves (QH, Eta, P1, P2, etc.) which can be adapted to the den-
sity and viscosity of the pumped liquid and show the number of
pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.

Literature

In this section you can access all the latest documents of a given
pump, such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures.

Service

This section contains an easy-to-use interactive service catalogue.


Here you can find and identify service parts of both existing and dis-
continued Grundfos pumps.
Furthermore, this section contains service videos showing you how
to replace service parts.

142
Further product documentation TP, TPD, TPE, TPED

Sizing 0 1

This section is based on different fields of application and installa-


tion examples, and gives easy step-by-step instructions in how to
• select the most suitable and efficient pump for your installation
• carry out advanced calculations based on energy consumption,
payback periods, load profiles, life cycle costs, etc.
• analyse your selected pump via the built-in life cycle cost tool
• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing replace-


ment data of an installed pump in order to replace the pump with a
more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos


pumps with the one you have installed on your site. When you have
specified the installed pump, the guide will suggest a number of
Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and 3-


dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.

3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed informa-
tion on more than 185,000 Grundfos products in more
than 20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once a
year.
Fig. 41 WinCAPS CD-ROM

143
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

V7124417 1008
Repl. V7124417 0907
GB
Subject to alterations.

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark


Telephone: +45 87 50 14 00

www.grundfos.com

You might also like