Sl No DESCRIPTION Units Qty Rate

STP-1 ventilation

Supply, installing, testing, commissioning & handing over of


exhaust air unit of cabinet type, Floor mounted Double skin
horizontal unit. Each unit complete with squirrel cage induction
motor,With Activated corbon chemical filter, centrifugal fan belt
drive and vibration isolators. Motor shall be suitable for 415 + 10%
volts, 50 cycles AC supply with imported Nicotra / Kruger make
fans complete with Fan section with forward curved fan. Heavy duct
flexible double layer canvas connection shall be provided at the
outlet of unit Fan. Each exhaust unit should consist of two fan &
two motors half the capacity.

21,000 cfm @ 60mm.wg ESP (@ Block3 Terrace)(serves T3) Nos 1 219,143


11,000 cfm @ 60mm.wg ESP (@ Block3 Terrace)(serves T3) Nos 1 145,258

Cabinet Type Ventilation Fans For Toliets


Supply, Installation of GI casing, cabinet type Inline fan with
acoustic lining . Noise level shall be less than 55 DBA @ 3 Mts
distance
SITC of Starter panel to suit the below fans with A-O-M switch, N-O-
N-C-Contact (Potential free contact) for BMS interfacing, (Only
incoming feeder to be provided by Electrical contractor. Starter
panel with DOL or Star/delta starter in HVAC contractor scope.
Cable from Panel to fan with earthing is under electrical contractor
scope and quoted all inclusive. Starter panel should also consist fire
interlock provision to start on fire signal - Starter panel to be as per
approved makes. Necessary control and power caling with trays,
earthing , end terminations to be considered in HVAC scope.
Note: Starter panel to be selected as per actual selection of Motor
KW rating

1,350 CFM, ESP 25mmwg static - Right Gents Toilet (GF) Nos 1 27,211
800 CFM, ESP 25mmwg static - Right Gents Toilet (GF) Nos 1 13,787
550 CFM, ESP 25mmwg static - Right Ladies Toilet (GF) Nos 1 13,787

Supply, Installation of GI casing, cabinet type Inline fan with


acoustic lining . Noise level shall be less than 55 DBA @ 3 Mts
distance
SITC of Starter panel to suit the below fans with A-O-M switch, N-O-
N-C-Contact (Potential free contact) for BMS interfacing, (Only
incoming feeder to be provided by Electrical contractor. Starter
panel with DOL or Star/delta starter in HVAC contractor scope.
Cable from Panel to fan with earthing is under electrical contractor
scope and quoted all inclusive. Starter panel should also consist fire
interlock provision to start on fire signal - Starter panel to be as per
approved makes. Necessary control and power caling with trays,
earthing , end terminations to be considered in HVAC scope.
Note: Starter panel to be selected as per actual selection of Motor
KW rating

900 CFM, ESP 25mmwg static - Left Gents Toilet (1F-17F) Nos 17 13,787
675 CFM, ESP 25mmwg static - Left Ladies Toilet (1F-17F) Nos 17 13,787
950 CFM, ESP 25mmwg static - Right Gents Toilet (1F-17F) Nos 17 13,787
700 CFM, ESP 25mmwg static - Right Ladies Toilet (1F-17F) Nos 17 13,787

1 Exhaust Air Axial Fans


Supply, installing, testing, commissioning & handing over of Single
speed Axial fans shall be complete with casing made of Hot dipped
Galvanized steel, motor, with impeller (Hub and blades) shall be
constructed of die cast aluminium alloy. Impeller should have
aerodynamic profile. Direction of discharge and rotation position
shall be as per the job requirement and shall be marked on the fan
assembly. Also bird screen, mounting legs, BDD, silencers and all
necessary standard accessories with, respective starter panel with
NONC potential free contact, cabling to be provided with supply of
fans.
1.01 6000 cfm @ 20mm.wg (For Tank Areas Makeup Air) Nos 9 20,022

2 Lift lobby & Fire Tower pressurisation system


Supply, testing & commissioning of of Axial Type Fans of following
Capacity for following lift lobbies
Motor : --- Kw ( as per selection) /4 or 6 Pole / IE3 Efficiency
motor
Axial fan Impeller dia to be as per manufacturing standardsNote :
1. )The Fresh Fans are designed for ambient Temperature.
2.) Direction of Discharge and Rotation shall be marked on the fan
assembly, Impeller should aerodynamic Profile & Outlet Velocity
Below 16m/s
3. ) Scope of Supply : Axial Fan with Single Speed Motor,Bird
Screen (1 No.) and Mounting Legs1. Any certification reqd like
AMCA to be considered.
Technical requirements
1. Motor characteristic. - 415+_ 10%, 50 HZ, 3 Phase, Kw ( as per
selection) /4 or 6 Pole / IE3 Efficiency motor

2. Class of insulation - Class F.


3. Noise criterion- 80 Dba at 3 meter at free field condition.
4. Motor efficiency -70-75%
5. Fan efficiency -65%
Note: Fan outlet velocity-16 m/s
The fans should be suitable for outdoor type installation.

2.01 19,200 CFM, ESP 35mm static - Lift Lobby Low Rise (TERRACE) Nos 1 46,913
2.02 19,200 CFM, ESP 35mm static - Lift Lobby High Rise (TERRACE) Nos 1 46,913
2.03 17,400 CFM, ESP 35mm static - FT Lift Lobbies (TERRACE) Nos 2 46,913
2.04 16,100 CFM, ESP 35mm static - Transfer Lobby (GF) Nos 1 45,142

3 Staircase pressurisation system


Supply, testing & commissioning of of Axial Type Fans of following
Capacity for following
Motor : --- Kw ( as per selection) /4 or 6 Pole / IE3 Efficiency
motor
Axial fan Impeller dia to be as per manufacturing standards
Note :
1. )The Fresh Fans are designed for ambient Temperature.
2.) Direction of Discharge and Rotation shall be marked on the fan
assembly, Impeller should aerodynamic Profile & Outlet Velocity
Below 16m/s
3. ) Scope of Supply : Axial Fan with Single Speed Motor,Bird
Screen (1 No.) and Mounting Legs1. Any certification reqd like
AMCA to be considered.
Technical requirements
1. Motor characteristic. - 415+_ 10%, 50 HZ, 3 Phase, Kw ( as per
selection) /4 or 6 Pole / IE3 Efficiency motor

2. Class of insulation - Class F.


3. Noise criterion- 80 Dba at 3 meter at free field condition.
4. Motor efficiency -70-75%
5. Fan efficiency -65%
Note: Fan outlet velocity-16 m/s
The fans should be suitable for outdoor type installation.
3.03 22,100 CFM, 35mm ESP for Staircases-1 (TERRACE) Nos 1 70,108
3.04 22,100 CFM, 20mm ESP for FT Staircases-2 & 3 (TERRACE) Nos 2 44,870
3.05 5,000 CFM, 20mm ESP for Basement Staircases Nos 1 20,820

4 Axial Ventilation Fans


Supply, testing & commissioning of of Axial Type Fans of following
Capacity for following
Motor : --- Kw ( as per selection) / 4 or 6 Pole / IE3 Efficiency
motor
Axial fan Impeller dia to be as per manufacturing standards
Note :
1)The Fresh Fans are designed for ambient Temperature.
2) Direction of Discharge and Rotation shall be marked on the fan
assembly, Impeller should aerodynamic Profile & Outlet Velocity
Below 16m/s
3) Scope of Supply : Axial Fan with Single Speed Motor,Bird Screen
(2No.) and Mounting Legs1. Any certification reqd like AMCA to be
considered.
Technical requirements
1. Motor characteristic. - 415+_ 10%, 50 HZ, 3 Phase

2. Class of insulation - Class F.


3. Noise criterion- 80 Dba at 3 meter at free field condition.
4. Motor efficiency -70-75%
5. Fan efficiency -65%
And need to interlock with the fire panel & cylincer shall be
provided to achieve noise levels.
4.06 5500 cfm @ 20mm.wg ESP- Chiller Plant Exhaust Nos 5 19,239
4.07 4700 cfm @ 20mm.wg ESP- Chiller Plant Fesh Air Nos 5 18,534
4.08 8500 cfm @ 20mm.wg ESP - fire sump pump room- Exhaust Nos 1 22,695
4.09 7250 cfm @ 20mm.wg ESP - fire sump pump room- Fresh air Nos 1 21,668
4.10 40,000 cfm @ 20mm.wg ESP- DG Fresh air Nos 9 108,724
4.11 5500 cfm @ 20mm.wg - Electrical Room Exhaust Nos 3 19,239
4.12 4800 cfm @ 20mm.wg - Electrical Room fresh Air Nos 3 18,534
4.13 4500 cfm @ 20mm.wg - Transformer Room Exhaust Nos 3 18,534
4.14 3800 cfm @ 20mm.wg - Transformer Room Fresh Air Nos 3 14,790
4.15 9800 cfm @ 20mm.wg ESP - PHE pump room- Exhaust Nos 1 26,734
4.16 8350 cfm @ 20mm.wg ESP - PHE pump room- Fresh air Nos 1 22,695
4.17 5500 cfm @ 20mm.wg ESP - OWC Exhaust air Nos 1 19,239
4.18 4800 cfm @ 20mm.wg ESP - OWC Fresh air Nos 1 18,534

I AXIAL FLOW FANS FOR VENTILATION SYSTEM

Supply, testing & commissioning of Dual speed Axial fans Fresh air
Fans of following Capacity for following basements
Motor : 7.5 / 11.0/ 15.0 Kw/ 6 Pole
Axial fan Impeller dia to be as per manufacturing standards
Note :
1)The Fresh Fans are designed for ambient Temperature.
2) Direction of Discharge and Rotation shall be marked on the fan
assembly, Impeller should aerodynamic Profile & Outlet Velocity
Below 16m/s
3) Scope of Supply : Axial Fan with Single Speed Motor,silencer,Bird
1
Screen (1 No.) and Mounting Legs. Any certification reqd like AMCA.

Technical requirements
1. Motor characteristic. - 415+_ 10%, 50 HZ, 3 Phase

2. Class of insulation - Class F.


3. Noise criterion- 80 Dba at 3 meter at free field condition.
4. Motor efficiency -70-75%
5. Fan efficiency -65%
1.1 Basement 1
a Zone 5 - 34,000 CFM @ 20mm.wg Nos 2 146,677
b Zone 6 - 29,000 CFM @ 20mm.wg Nos 2 131,683
c Zone 7 - 39,000 CFM @ 20mm.wg Nos 2 156,109
d Zone 8 - 32,000 CFM @ 20mm.wg Nos 2 146,677
e Zone 11 - 38,000 CFM @ 20mm.wg Nos 2 156,109
f Zone 13 - 37,000 CFM @ 20mm.wg Nos 2 156,109

1.2 Basement 2
a Zone 5 - 27,000 CFM @ 20mm.wg Nos 2 122,549
b Zone 6 - 19,000 CFM @ 20mm.wg Nos 2 77,071
c Zone 7 - 24,000 CFM @ 20mm.wg Nos 2 122,549
d Zone 8 - 25,000 CFM @ 20mm.wg Nos 2 122,549
e Zone 11 - 27,000 CFM @ 20mm.wg Nos 2 122,549
f Zone 13 - 27,000 CFM @ 20mm.wg Nos 2 122,549

1.3 Basement 3
a Zone 5 - 27,000 CFM @ 20mm.wg Nos 2 122,549
b Zone 6 - 19,000 CFM @ 20mm.wg Nos 2 77,071
c Zone 7 - 24,000 CFM @ 20mm.wg Nos 2 122,549
d Zone 8 - 25,000 CFM @ 20mm.wg Nos 2 122,549
e Zone 11 - 27,000 CFM @ 20mm.wg Nos 2 122,549
f Zone 13 - 27,000 CFM @ 20mm.wg Nos 2 122,549

1.4 Basement 4
a Zone 5 - 22,000 CFM @ 20mm.wg Nos 2 77,071
b Zone 6 - 13,000 CFM @ 20mm.wg Nos 2 66,049
c Zone 7 - 24,000 CFM @ 20mm.wg Nos 2 122,549
d Zone 8 - 25,000 CFM @ 20mm.wg Nos 2 122,549
e Zone 11 - 27,000 CFM @ 20mm.wg Nos 2 122,549
f Zone 13 - 27,000 CFM @ 20mm.wg Nos 2 122,549

1.5 Basement 5
a Zone 5 - 22,000 CFM @ 20mm.wg Nos 2 77,071
b Zone 6 - 13,000 CFM @ 20mm.wg Nos 2 66,049
c Zone 7 - 24,000 CFM @ 20mm.wg Nos 2 122,549
d Zone 8 - 25,000 CFM @ 20mm.wg Nos 2 122,549
e Zone 11 - 27,000 CFM @ 20mm.wg Nos 2 122,549
f Zone 13 - 27,000 CFM @ 20mm.wg Nos 2 122,549
Supply, testing & commissioning of Dual speed Axial fans shall be
complete with casing made of Galvanized steel, motor, with
impeller (Hub and blades) shall be constructed of die cast
aluminium alloy. Impeller should have aerodynamic profile.
Direction of discharge and rotation position shall be as per the job
requirement and shall be marked on the fan assembly.

Common Exhaust - Axial fan capacity: as below .


Motor:7.5/15.0 /18.5 kw /6 Pole
Axial fan Impeller dia to be as per manufacturing standards.
Direction of Discharge and Rotation shall be marked on the fan
assembly, Impeller should aerodynamic Profile & Outlet Velocity
2
Below 16m/s.
Scope of Supply: Fan with Single speed High Temperature motor
250 deg C for 2 hrs, 2 Nos. Bird Screen &

Technical requirements
1. Motor characteristic. - 415+_ 10%, 50 HZ, 3 Phase

2. Class of insulation - Class H.


3. Noise criterion- 80 Dba at 3 meter at free field condition.
4. Motor efficiency -70-75%
5. Fan efficiency -65%

2.1 Basement 1
a Zone 5 - 41,000 CFM @ 20mm.wg Nos 2 148,717
b Zone 6 - 35,000 CFM @ 20mm.wg Nos 2 148,717
c Zone 7 - 47,000 CFM @ 20mm.wg Nos 2 162,449
d Zone 8 - 37,000 CFM @ 20mm.wg Nos 2 148,717
e Zone 11 - 46,000 CFM @ 20mm.wg Nos 2 162,449
f Zone 13 - 45,000 CFM @ 20mm.wg Nos 2 162,449

2.2 Basement 2
a Zone 5 - 33,000 CFM @ 20mm.wg Nos 2 143,638
b Zone 6 - 23,000 CFM @ 20mm.wg Nos 2 76,991
c Zone 7 - 29,000 CFM @ 20mm.wg Nos 2 124,848
d Zone 8 - 30,000 CFM @ 20mm.wg Nos 2 124,848
e Zone 11 - 32,000 CFM @ 20mm.wg Nos 2 143,638
f Zone 13 - 32,000 CFM @ 20mm.wg Nos 2 143,638

2.3 Basement 3
a Zone 5 - 33,000 CFM @ 20mm.wg Nos 2 143,638
b Zone 6 - 23,000 CFM @ 20mm.wg Nos 2 76,991
c Zone 7 - 30,000 CFM @ 20mm.wg Nos 2 124,848
d Zone 8 - 30,000 CFM @ 20mm.wg Nos 2 124,848
e Zone 11 - 32,000 CFM @ 20mm.wg Nos 2 143,638
f Zone 13 - 32,000 CFM @ 20mm.wg Nos 2 143,638

2.4 Basement 4
a Zone 5 - 33,000 CFM @ 20mm.wg Nos 2 143,638
b Zone 6 - 23,000 CFM @ 20mm.wg Nos 2 76,991
c Zone 7 - 29,000 CFM @ 20mm.wg Nos 2 124,848
d Zone 8 - 30,000 CFM @ 20mm.wg Nos 2 124,848
e Zone 11 - 32,000 CFM @ 20mm.wg Nos 2 143,638
f Zone 13 - 32,000 CFM @ 20mm.wg Nos 2 143,638

2.5 Basement 5
a Zone 5 - 26,500 CFM @ 20mm.wg Nos 2 118,046
b Zone 6 - 16,000 CFM @ 20mm.wg Nos 2 72,018
c Zone 7 - 29,000 CFM @ 20mm.wg Nos 2 124,848
d Zone 8 - 30,000 CFM @ 20mm.wg Nos 2 124,848
e Zone 11 - 32,000 CFM @ 20mm.wg Nos 2 143,638
f Zone 13 - 32,000 CFM @ 20mm.wg Nos 2 143,638
Supply, testing & commissioning of Jet fans for Basement 1, 2, 3, 4
&5
Fan Model : 350 mm impeller dia Jet fans with deflector
Motor : 0.3 / 1.3 kw @ 4 / 2 Pole
Note : Jet fans are designed to run at 300 Deg. C for 2 Hours
incase of emergency
Technical Details

1. Motor characteristic- 415+_ 10%, 50 HZ, 3 Phase


2. Class of insulation - Class H.
1 3. Noise criterion - 57 / 71 @ Low / High speed @ 3 metres is Nos 132 30,207
acceptable
4. Speed and respective air handling capacity, CFM -Rpm @ Low /
High speed - 1405 / 2815
CFM @ Low / High speed - 2900 / 5900
5. Motor efficiency -70-75%
6. Fan efficiency -65%
7. Silencer length shall be 2 times of dia.

8. Rubber hanger, mounting legs, threaded rod suppot, nuts, bolts


should form part of Jetfan supply
CO Sensor -Greystone make (4-20 Amp only) - Parts
75 8800
of Jet Fan
CFD Analysis 5
TOTAL
Packing

Inland transit charges


Insurances
Custom duty & custom clearance charges,
State Entry Tax & Octroi / Road Permits
Unloading, Lifting & Shifting
Discount
GRAND TOTAL

Country of Origin
Sound Attenuator
Starter panels / VFDs
Accessories such as bird screen, companion flanges etc
Supporting Kits / Vibration isolators
Motor
Fire Rating
Humadian
RATE /
Amount
CFM

219,143
145,258

27,211
13,787
13,787
-

-
-

-
234,379
234,379
234,379
234,379
-
-

180,198
-
-
-

-
46,913
46,913
93,826
45,142
-
-
-

70,108
89,740
20,820
-
-

96,195
92,670
22,695
21,668
978,516
57,717
55,602
55,602
44,370
26,734 `
22,695
19,239
18,534
-

-
293,354
263,366
312,218
293,354
312,218
312,218
-
-
245,098
154,142
245,098
245,098 `
245,098
245,098
-
-
245,098
154,142
245,098
245,098
245,098
245,098
-
-
154,142
132,098
245,098
245,098
245,098
245,098
-
-
154,142
132,098
245,098
245,098
245,098
245,098
-

-
-
297,434
297,434
324,898
297,434
324,898
324,898
-
-
287,276
153,982
249,696
249,696
287,276
287,276
-
-
287,276
153,982
249,696
249,696
287,276
287,276
-
-
287,276
153,982
249,696
249,696
287,276
287,276
-
-
236,092
144,036
249,696
249,696
287,276
287,276
-
3,987,324

660,000

-
23,055,853 23,093,464