Hubant

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3
At a glance
Powered by AI
The document appears to be a quotation for supplying and installing a VRV air conditioning system.

The document is quoting the supply and installation of a VRV air conditioning system including outdoor units, indoor units, refrigerant piping, and other components.

The payment terms listed are 100% advance payment for equipment and 50% advance on materials, 40% after installation, 10% after commissioning for installation work.

Mob No :- 9212682399

RVA ENGINEERS LLP


AIR CONDITIONING, REFRIGERATION ENGINEERS & CONTRACTORS
Spl.in Maintenance of :٠Central A/C Plant Package٠Unit Split& Window A/C ٠Dairy Plants
٠Cold Storage٠Chilling Plant for Injection Moulding, Brewery Palnts٠Any type of Air Conditioning Works
Reg At :- F64/C-3 Flate No 61 .Sec-40 Noida (U.P.)
Works At :- C-55 , sector -9 , Noida (U.P) .

Annexure-II-A (SUPPLY OF EQUIPMENT)


PART-1
Description - Variable Refrigerant Volume System Unit Qty. Rate Total Amount
(Rs.)

1 Supply of VRV Modular Type Air-conditioning System with Inverter Based Technology with factory
fitted Indoor and Outdoor Units, Induvidual Temperature Controller with each Indoor Unit
complete with interconnected refrigerant piping with control wiring as per Standards and
specifications between Indoor and Outdoor Units, full charge of refrigerant gas and oil after
necessary vacumising, nitrogen flushing and pressure testing of system.

A) Supply of Outdoor Units Equiped with Highly efficient


Multiple scroll Compressors with all Variable speed in
each outdoor unit with noise level not exceeding 67db(A),
etc. with Nitrogen Reprocessing, vacumising, Charging
and Top-up of R410 A gas (Heating & Cooling) as per
requirement at site.
i) 5 HP (RXRQ5ARV16) Nos. 1 87,500 87,500

2 Supply of Indoor Units with outer cabinet equipped with


pre air-filters, multispeed Inverter Motor, DX Coil
Section, Drain Pain, Builtin Drain Pump,electronic
expansion valves, pipe connections, PCBs etc.

A) Wall Mounted Type AC


i) FXARQ25ARVE6 (0.8 TR) Nos. 1 20,489 20,489
ii) FXARQ40ARVE6 (1.28 TR) Nos. 1 22,765 22,765
iii) FXARQ63ARVE6 (2.02 TR) Nos. 1 24,571 24,571

3 Supply of Interconnecting "Y" Joints i.e. Refnet


Joints/Header with Insulation for refrigerant piping
A) Y Joints (72T, 33T, 22T) Nos. 2 2,277 4,554

4 Lifting, Shifting, Installation, Testing and Commissioning


of System Controllers
A) Cordless Nos. 3 3,430 10,290

TOTAL VALUE OF Annexure-II-A (SUPPLY OF EQUIPMENT) 1,70,169

GST WILL BE PAID EXTRA


PART-2
Annexure-II-B (INSTALLATION WORK)
Description - Variable Refrigerant Volume System Unit Qty. Rate Total Amount
(Rs.)

1.0 Installation, Testing and Commissioning of VRV Modular Type Air-conditioning System with
Inverter Based Technology with factory fitted Indoor and Outdoor Units, Induvidual Temperature
Controller with each Indoor Unit complete with interconnected refrigerant piping with control
wiring as per Standards and specifications between Indoor and Outdoor Units, full charge of
refrigerant gas and oil after necessary vacumising, nitrogen flushing and pressure testing of system.
A) Lifting, Shifting, Installation, Testing and Commissioning
of Outdoor Units Equiped with Highly efficient Multiple
scroll Compressors with all Variable speed in each
outdoor unit with noise level not exceeding 67db(A), etc.
with Nitrogen Reprocessing, vacumising, Charging and
Top-up of R410 A gas as per requirement at site.
i) 5 HP (RXRQ5ARV16) Nos. 1 7,000 7,000
B) Additional Gas Charging for
i) 5 HP (RXRQ5ARV16) Nos. 1 10,000 10,000

2 Lifting, Shifting, Installation, Testing and Commissioning


of Indoor Units with outer cabinet equipped with pre air-
filters, multispeed Inverter Motor, DX Coil Section, Drain
Pain, Builtin Drain Pump, electronic expansion valves,
pipe connections, PCBs etc.
A) Wall Mounted Type AC
i) FXARQ25ARVE6 (0.8 TR) Nos. 1 1,500 1,500
ii) FXARQ40ARVE6 (1.28 TR) Nos. 1 1,500 1,500
iii) FXARQ63ARVE6 (2.02 TR) Nos. 1 1,500 1,500

3 Lifting, Shifting, Installation, Testing and Commissioning


of Interconnecting "Y" Joints i.e. Refnet Joints/Header
with Insulation for refrigerant piping

A) Y Joints (73, 72T, 33T, 22T) Nos. 2 250 500

4 Supply, Installation, Testing and Commissioning of Rmt 30 1,100 33,000


refrigerant piping, tees, sockets, expanders and reducers
as per requirement at site complete with supports,
threaded rods, channel, tie, fastners etc. interconnecting
the outdoor condensing units and indoor evaporating units
with closed cell elastomeric nitrile rubber tubular
insulation of 19mm on gas pipe line and 13mm on liquid
pipe line. (Quantities Quoted here are only for estimation
purpose on tentative basis and However they are to be
Charged as per actual measurement at site on Rmt basis
as applicable)

5 Supply, Installation, Testing and Commissioning of 2 core Rmt 40 150 6,000


x 1/1.5 sq.mm copper conductor cable as per requirement
at site complete with supports, threaded rods, channel, tie,
fastners etc. for control between indoor and outdoor unit
& for communication between Indoor Unit & Remote
Controllers in suitable PVC Conduict (Quantities Quoted
here are only for estimation purpose on tentative basis and
However they are to be Charged as per actual
measurement at site on Rmt basis as applicable)
6 Supply, Installation, Testing and Commissioning of Hard
u-PVC condensate drain piping with 9 mm thick closed
cell elastomeric nitrile rubber tubular insulation up to the
nearest drain point along with necessary fittings.
(Quantities Quoted here are only for estimation purpose
on tentative basis and However they are to be Charged as
per actual measurement at site on Rmt basis as
applicable) Insulation and instolation will be done by us
A) 25mm Rmt 30 120 3,600

7 Outdoor Stand with Epoxy Paint As Per Customer


Requirment
i) 5 HP (RXRQ5ARV16) Nos. 1 2,800 2,800

TOTAL VALUE Annexure-II-B (INSTALLATION WORK) 67,400


PART-3
TOTAL VALUE OF Annexure-II-A (SUPPLY OF EQUIPMENT) 1,70,169

TOTAL VALUE Annexure-II-B (INSTALLATION WORK) 67,400


GRAND TOTAL VALUE OF (Annexure-II-A + Annexure-II-B) 2,37,569

GST @28% on Equipment’s Value & @18% on Low Side Work Would be Charged Extra.

Payment Terms & Conditions:-

High Side

1. 100% Advance Payment of High Side (i.e. of Equipment Value) along with Performa Invoice.

Low Side

1. 50% Advance Payment of Low Side work when the Material is ready for shipping.
2. 40% Payment after All Piping & Ducting Work Installation.
3. 10% After Commissioning & Handing Over.

Thanking You,

RVA ENGINEERSLLP
C-55, Sec-9 Noida

You might also like