SWORD Escalator Travolater S900E S900T Giantliftslimited

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

S900E Escalators

S900T Travelator

HANGZHOU SWORD ELEVATOR CO.,LTD.


ADD:169 Hengyi Road,Yuhang Economic Development Zone,
Zhejiang Province(311100)
Domestic sales hotline:0571-86902699
Export sales hotline:0086-571-56076090
FAX:0571-86903368 WEB:www.sword-cn.com

SERVICE LINE /400-826-9998


STICK FOR TRAVEL WORLD IN HEART

The manufacturing base of SWORD in Hangzhou


Yuhang Economic development Zone

◎ Invest 500 million yuan


◎ 110,000 square meters ◎ An annual output of 50000 units
◎ Over 120 meters in height with the elevator testing ability of 10m/s
leadingdomestic elevator testing tower

HANGZHOU SWORD ELEVATOR CO., LTD. was established in 2009 and


located in National Economic and Technological Development Zone-
Hangzhou City. We're the international comprehensive elevator manufacture
which integrates elevator and escalator R&D, design, production, sale,
installation and after-sales maintenance. Our annual production capacity of
elevator and escalator is up to 50,000 units which leading the industry.
Our products cover small machine room passenger elevator, machine
room-less passenger elevator, high-speed elevator, medical lifts, service lifts,
sightseeing elevators, escalators, moving walkways and vehicle elevators ,
totally nine series, among which our high-precision, high-qualification
environmentally friendly products have went through German TUV certification,
European Union CE, the Russian CU-TR certification, JKKP Malaysia certification,
Algeria ENACT certification and successfully joined in the North American
CSA and ASME certification system. We have provided service and
solutions for more than 70 countries and regions worldwide by now, our
brand influence and reputation are on the rise.
PERFORMANCE
Efficient and reliable and safe,it is your first choice Perfect quality
extrodinary performance

Escalators, travelator have been painted the flowing landscape in the buildings. Hangzhou SWORD
Elevator Co., Ltd in the building products, not only considers the traditional elements of safety, energy
saving, comfort, quiet, but also seeks to coordination and interaction with the building, completeness
and convenience of functions. Because of this, many airports, transportation hubs, shopping malls
select the S900E, S900T products of Hangzhou SWORD elevator.

◎Safe and Reliable


Meet the latest safety standards, safety switch spreads all over the key parts, real time monitoring the
running condition.
◎Easy to Maintain
Use the fault self-diagnostic indication device; quickly find the cause and part of the faults, and reduce
the downtime.
◎Strong Driving Force
The strong, reliable driving host can meet the short-time overload.
◎Excessive Environmental Adaptability
It’s suitable for indoor and outdoor environments, suitable for 50Hz and 60Hz frequencies, and running under
a variety of voltages.
Dedicated Host
Driven System

The host of escalators, travelator has technical improvement


on the basis of original advantage, and through continuous tuning
and testing, make the driving stronger, running more smooth and
braking more timely, sensitive.

Precision, Energy-saving
Control System

Control system adopts a microcomputer system with advanced


technology and improved functionalities, the function is complete,
the reaction speed is fast, to meet different kinds of needs of
customers. Control cabinet is located in top of the shelves, full
monitoring the running state, timely eliminating the running
hidden troubles, reducing the maintenance time.

DELICATE
Delicate parts, perfectly embodies the art
Truss Handrail
扶手带标准色(国产)
Standard color
Truss is welded of rectangular tube materials; A variety of professional design, stylish and durable
with seal welded bed plate to ensure that water handrail can be flexibly selected according to different
and oil stain will not leak from the bed plate. With environment.
hard stability and bearing capacity, it can effectively
extend the life of escalators.

扶手带可选色(合资)
Optional color
Aluminum Alloy Step Shoe Brake

The surface of pallets sprays the black electrophoretic Shoe brake is placed between the motor and
paint, hard texture, oxidation resistance, easy gear box, with the reliable and easily regulative
maintenance. Engrave antiskid patterns, embed characteristic, can guarantee a smooth braking
with a yellow warning on both sides. performance and (security) braking distance.

Ladder system Automatic Lubrication

Adopting galvanized steel rail、high strength and good Use computer-controlled automatic lubrication
wear resistanse polyurethane roller and high strength system, no need full-time staff refuel, and ensure
plate chain, offering products the ability of resistance to control a moderate amount of the fuel.
to corrpsion and making life longer.
S900E Public Escalator Peak Performance Masterpiece of Sword

Considering different environments and traffic flow, Hangzhou Sword Elevator


Co., Ltd. launch the S900E public escalator. By its strong performance, ultra
high vertical rise, S900E public escalator meets various transit requirements
of subways, railway stations, airports etc.In ordinary high rise occasions,
segmented escalators are used for carrying passengers. But walking buffering
area will cause passengers crowding, which bring potential safety hazard.
Double Motors
S900E Public Escalator, with maximum rise up to 26m, totally solve the dense ◎ Both side motors, super power
traffic flow of high rise occasions, and save more construction cost.
◎Both side breaks, double safeguard

External Type Chain Roller

◎Large diameter external type chains, easier to replace.


◎ Widened type chain links, sturdy and durable.

Removable Guide Rail

◎Reduce the contact surface between guide


rail and rollers, prolong the lifespan of rollers.
◎Absorb shock, improve the comfortability.
Security protection (standards)

Comb protection device


Handrail entrance protection device
Step sunk protection device
Protection device for loosen/broken step chain
Protection device for over-speed of traction machine
Non-manipulated reversal protection device of traction machine
Safety switch for fan cover in open position
Contactor protection
Relay adhesion protection
Inverter/converter fault protection
Protection device for phase failure or error
Detection for open contracting brake
Skirt panel brush protection
Motor overload & overheat protection
Water level detecting switch (outdoor type)
Measurement for handrail speed (outdoor type)
Safety switch for broken drive-chain
Front plate opening protection

SECURITY Security protected (Optional)

Improve system security, peace of mind, rest assured, Protection for broken handrail
comfortable Apron protection safety switch
Detection for over-worn brake shoe
Additional brake (>6m standard specification)
Oil level alarm switch
This type of escalator/travelator adopted the comprehensive safety protective measures,
Step lighting
and basically eliminate all sorts of accident happening
Comb lighting
Basic function Optional function

Select the Running Direction The entrance of escalators and moving walk operating box has a key switch control, the Running Direction Indicator It is equipped with luxurious running direction indicator lamp at the entrance, make the escalator,
panel has " " mark which is easy to operate. With the dedicated key following the Lamp travelator more elegant and noblest.
escalator you can select the running direction as required.

Skirt Lighting Install on the both sides of skirt panel, streamlined line high brightness lighting along the
Warning before Startup Inspection operation is without warning, warning before the normal startup, the bell rings for escalator will not only improve the security, but also enhance the elegant temperament of
3 seconds, and then type Y starts, after 3 seconds, type △ normally operates, the ring building inside environment.
disappears. Before and after the startup if there are unusual circumstances, you can press
the emergency stop button of operating panel, to put an end to start.
Balustrade Lighting Install inside the balustrade bracket, can attract passengers more stable holding the handrail,
like the skirt panel lighting, can enhance the temperament of building inside environment.
Automatic Lubrication Use computer-controlled automatic lubrication system, don’t need full-time staff refuel,
and ensure to control a moderate amount of the fuel.
Oblique Balustrade Mainly apply to the transportation hubs of large people flow and load bearing pressure and
other places, can maximally extend the space and comfort of the escalator, while improve
Automatic Fault Display Maintain a constant monitoring of machine running condition, when there is a fault, it the security of passengers.
displays the fault location timely on the nixie tube, allows service personnel to find fault
immediately and easy to maintain, reduces the downtime.
Step Warning Light The top and bottom of step pallets is equipped with the warning light, it can make the passengers
distinguish the stagger and leveling condition of step, improve the security of escalator.
Inspection Inching In order to easy to maintain and repair the escalator, travelator, the escalator and travelator
has the function of inspection inching. Insert the inspection plug into the any of inspection
outlet of upper and under machine room, the escalator, travelator then goes into an
inspection condition. All safety switches of escalator, travelator function the same as normal
operation in an inspection condition.

Host Speed Testing In order to ensure the safety of passengers, when the running speed of escalator, travelator
is 20% faster than the rated speed, the escalator, travelator will automatically stop operating,
and start running after professional disposes.

Motor Protection Function In order to guarantee the safety of equipment, the escalator, travelator has the function of
motor overheating protection, phase failure protection, etc.

Frequency Conversion Select the dedicated inverter to control the escalator, travelator’s running, run in the low-
Function(Only Escalators) speed condition of 0.2m/s without people; When the infrared device of the entrance detect
a person walk into the front pallets area of escalator, travelator, the escalator, travelator runs
in the normal condition of 0.5m/s, energy saving can reach to 40%-60%, and reduces the
peak current 50%-80%, to make the mechanical wear reduced.

Skirt Panel Brush Install on the both sides of skirt panel, avoid the shoes, shoelaces to scuff or involve in the
(Only Domestic) skirt panel, improve the security.
S900E Commercial Escalator layout
Done by owner or builder

◎ This drawing is fit for the products with rise 3m≤ H≤ 8m,the permitted tolerance for rise is -15mm~+15mm;The permitted
tolerance for level length is 0~+15mm.
◎When the level length L>15.3m, the intermediate support base is needed.
Clear floor access area
(both upper and lower landing) ≥2000 ◎ Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the
Min500

sthengh is enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
◎The pit should be water-proof, and the location of plash should be set at the corner.
◎The pit drain hole should be connected with the drainage system, the work should be done by others.

2×C
C
◎ According to the requirement of the technical data, the power supply with safety switch is set at the machine room. The
fluctuation of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is
not more than 4Ω.
≥2500
◎Use 10mm2 soft line as the power input cable, done by others.
◎When the space between handrail center line and other barrier is less than 500mm, a guard plate without sharp edge should be
set above outter deck plate, and the height should not less than 300mm.
Hole for lifting or hook(by others)
◎If there is any special requirement, the contract should be made after approved by the company technical depaprtment

100
L
F >AK

Safety fence(by others)

Hole for lifting or hook(by others) Delta guard (by others)

RU
Up escalator(if there is)
S

100
≥2300

Power supply,elongate four meters(by others)


H

C
Bottom escalator
RM B

≥2300
A Note: If the escalator is up and bottom arrangement, it is
required to have 2300mm clear space above the bottom
HM

Before or after installation, this area should escalator. Refer to the dash area in the left. Any questions,
RD not have any barrier. pls contact SWORD technical department.
a
AM min

MinAH
L1=L/2
Drainage hole
H

Finished floor level


200 40
400
DA

Finished floor by others


Steel plate30×180×D
250

(by others) Steel plate


D-50

30×400×400 Other dimensions(mm) Reaction(KN)


D

Foot bolt φ16×150


Full length of support nose to By others) Speed Rise H Step Width Span L
Angle(a) Flat steps AM(mm) DA(mm)
be true level 400 (m/s) (mm) A (mm) (mm)
AH AK B C D E F RU RD RM
600 1.428H+5405 6450 837 1130 1240 1100 3.76L+18 3.76L+12
400

EDGE OF TRUSS
35° 0.5 3000≤H≤6000 2 800 1300 1.428S 4.41L+15 4.41L+9
1.428H+4905 4060 5950 1037 1330 1440 For Indoor, 1103 Without Shock
30×400×400

108
(By others)

Outdoormodel A absorbing rubber


Steel plate

1000 1237 1530 1640 1500 5.11L+13 5.11L+5


EDGE OF SUPPORT 500 800 1037 1330 1440 1300 2.02L+13.2 2.02L+6.8 6.33L+4.8
500 6000<H≤8000 3 1.732H+5565 4640 6950
1000 1237 1530 1640 1500 2.3L+13.6 2.3L+7.1 7.16L+4.9
E
30° 0.5 600 1.732H+5265 7050 837 1130 1240 1100 1.732S 3.66L+27 3.66L+22 For Outdoor model B With Shock
3000≤H≤6000 2 800 1037 1330 1440 1300 4.31L+18 4.31L+10 with Oil separator 1353 absorbing rubber 128
MinD 1.732H+4765 4240 6550
U/D Support Detail MID Support Detail MID Support Detail 1000 1237 1530 1640 1500 4.96L+17 4.96L+10

NOTE:DO NOT SCALE THIS DRAWING,UNLESS OTHERWISE STATED.


S900E Public Escalator layout

Done by owner or builder

◎ This drawing is fit for the products with rise 1.5m≤ H≤ 6m,the permitted tolerance for rise is -15mm~+15mm;The permitted
tolerance for level length is 0~+15mm.
≥ 2000 CLEAR ACCESS AREA (BOTH U/D LANDING) ≥ 2000
◎When the level length L>15.3m, the intermediate support base is needed.
◎Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the sthengh is
enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
◎The pit should be water-proof, and the location of plash should be set at the corner.
2*C

2*C
C

C
◎The pit drain hole should be connected with the drainage system, the work should be done by others.
◎ According to the requirement of the technical data, the power supply with safety switch is set at the machine room. The
fluctuation of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is
≥ 2500 ≥ 2500 not more than 4Ω.
◎Use 10mm2 soft line as the power input cable, done by others.
◎When the space between handrail center line and other barrier is less than 500mm, a guard plate without sharp edge should be set
HOISTING HOLE
above outter deck plate, and the height should not less than 300mm.
C
( ≥70KN, BY OTHERS)
B ◎If there is any special requirement, the contract should be made after approved by the company technical depaprtment
SAFETY FENCE A
(BY OTHERS)
100
L

SAFETY FENCE
(BY OTHERS) F >AK
≥ 1200

HOISTING HOLE( ≥70KN, BY OTHERS)


RU
VERTICAL FENCE (BY OTHERS) Up escalator(if there is)
100
≥ 2300

UPPER POWER SOURCE,


4m IN TRUSS (BY OTHERS)

RM2
H

Bottom escalator

≥2300
HM2

RM1 а Note: If the escalator is up and bottom


arrangement, it is required to have 2300mm clear
HM1

RD
Before or after installation, this area should
not have any barrier. space above the bottom escalator. Refer to the
AM min

dash area in the left. Any questions, pls contact


SWORD technical department.
DRAIN HOLE
(BY OTHERS)
Min AH E
L1 L2 L3
Min D

FINISHED FLOOR Angle Speed Rise Step Width Span Other dimensions(mm) Reaction(KN)
Flat Steps AM (mm) DA (mm)
(a) (m/s) H(mm) A(mm) L(mm)
300

AB AK B C D E F RU RD RM1 RM2

200 40 EMBEDDED STEEL PLATE 1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
3 1.732H+6576 4900 7750
30*200*300mm (BY OTHERS) 800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
30° 0.5,0.65 3,000~15,000 1.732S indoor
1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10 (without
DA

4 1.732H+7376 5300 8150 1150


Q+50

800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10 Oil water
220

separator)
1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
3 1.937H+6461 5050 8200
200 800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
27.3° 0.5,0.65 3,000~15,000 1.937S 150
1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
4 1.937H+7261 5450 8600
800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
300

outdoor
Y-BOLT Ø16*150 EMBEDDED STEEL PLATE 1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10 (with Oil
30*200*D (BY OTHERS) 3 2.333H+6287 5300 9010 water 1330
800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
23.2° 0.5,0.65 3,000~15,000 2.333S separator)
300 1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
4 2.333H+7087 5700 9410
800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10

U/D SUPPORT DETAIL(SYMMETRIC) MID SUPPORT DETAIL MID SUPPORT DETAIL (PLAN VIEW) NOTE:DO NOT SCALE THIS DRAWING,UNLESS OTHERWISE STATED.
S900E Heavy Public Escalator layout Done by owner or builder

◎ This drawing is fit for the products with rise 1.5m≤ H≤ 6m,the permitted tolerance for rise is -15mm~+15mm;The permitted
tolerance for level length is 0~+15mm.
◎When the level length L>15.3m, the intermediate support base is needed.
◎Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the sthengh is
enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
LL+160 LU+160
◎The pit should be water-proof, and the location of plash should be set at the corner.
◎The pit drain hole should be connected with the drainage system, the work should be done by others.
◎According to the requirement of the technical data, the power supply with safety switch is set at the machine room.The fluctuation
of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is not more
T

W.P. W.P. than 4Ω.


◎Use 10mm2 soft line as the power input cable, done by others.
GAP BETWEEN ESCALATOR AND FINISHED FLOOR (BY OTHERS)
◎When the space between handrail center line and other barrier is less than 500mm, a guard plate without sharp edge should be set
GAP BETWEEN ESCALATOR AND FINISHED FLOOR (BY OTHERS) above outter deck plate, and the height should not less than 300mm.
◎If there is any special requirement,the contract should be made after approved by the company technical depaprtment

DBE =LL+LS+LU M
LL LS=1.732H LU
N
Up escalator(if there is)
SAFETY FENCE
>3984+1.732S HU ≥2500 (BY OTHERS)
SAFETY FENCE (BY OTHERS)
P

SITE SURVEY
≥ 1200

R2000

1000
VERTICAL FENCE
(BY OTHERS)
W.P. ◎Install retention devices, anti-skid devices, anti-
S
BARRIER creep devices etc after installation (by others).
700

(CEILING ETC.)
UPPER POWER SOURCE (BY OTHERS)
A
Bottom escalator ◎Vertical fences must be established if any barrier

≥2300
≥ 2300

842
within 400mm of handrail center line. min. height of
40 vertical fences 300mm (by others).
C Before or after installation, this area should ◎ If escalator vertical height is above 22000mm, or

H
R20

≥2500 HL not have any barrier. civil dimensions differ from above requirement,
00

HM3 please contact sword company.


HM2
1000

W.P. 30° HM1 Overall Dimension (Length):(mm)


3500<H≤6000 6000<H≤10000 10000<H≤12000 12000<H≤15000 15000<H≤22000
Flat Steps 4 4 4 4 4
AM min

3 3 3 3 3
B

40
HM1=0.5x(DBS1-LL)-1.155xC-220 A 1400 1400 1400 1400 1400 1400 1400 1400 1600 1600
HM2=0.5x(DBS1+DBS2-LL)-1.155xC-220 B 1300 1300 1150 1150 1150 1150 1150 1150 1150 1150
HM3=0.5x(DBS1+DBS2+DBS3-LL)-1.155xC-220 C 1480 1480 980 980 1180 1180 980 980 980 980
DRAIN HOLE IF OUTDOOR
(BY OTHERS) LA min HU 2665 3065 2665 3065 2890 3290 2890 3290 2890 3290
LU 3680 4080 3680 4080 3905 4305 4405 4805 4405 4805
DBS1 DBS2 DBS3 DBS4 Q
HL 2280 2680 2280 2680 2280 2680 2280 2680 2280 2680
R min LL 2880 3280 2880 3280 2880 3280 2880 3280 2880 3280
R1 R3 R3 R3 R3 AM 1600 1600 1450 1450 1450 1450 1450 1450 1450 1450
LA 3080 3080 2080 2080 2480 2480 2080 2080 2080 2080
DBS1 -- -- 1/2DBE 1/2DBE 1/2DBE 1/2DBE 1/3DBE 1/3DBE 1/4DBE 1/4DBE
DBS2 -- -- 1/2DBE 1/2DBE 1/2DBE 1/2DBE 1/3DBE 1/3DBE 1/4DBE 1/4DBE
DBS3 -- -- -- -- -- -- 1/3DBE 1/3DBE 1/4DBE 1/4DBE
DBS4 -- -- -- -- -- -- -- -- 1/4DBE 1/4DBE

Remarks: LU, LL in above sheet are min. value, and can be prolonged. Max. LU 6000, Max. LL 5000. Otherwise please contact SWORD.
A
300

CAULKING, BACKFIL 200 40


FINISHED FLOOR (BY OTHERS)

EMBEDDED STEEL PLATE


30x200x300mm (BY OTHERS) Overall Dimension (Width):(mm)
150 M (Escalator Width) N (Handrail Width) P (Step Width) Q (Truss Width) R (Min. Pit Width)
Q+50
220

1730 1238 1002 1700 1790


EMBEDDED STEEL PLATE
Rx200x20 (BY OTHERS) 200

Reaction:(N)
300

Y-BOLT Ø16x150 (BY OTHERS)

Flat Steps Rise H Supports R1 R2 R3 R4 R5


300 3500<H≤6000 2 11H+36000 11H+48000 -- -- --
3 6000<H≤10000 3 5.5DBS1+8000 5.5DBS2+14000 5.5DBE+7000 -- --
10000<H≤12000 3 6DBS1+10000 6DBS2+20000 6DBE+7000 -- --
12000<H≤15000 4 6DBS1+10000 6DBS3+20000 6(DBE1+DBE2)+7000 6(DBE2+DBE3)+7000 --
15000<H≤22000 5 6.2DBS1+4000 6.2DBS4+17000 6.2(DBE1+DBE2)-4000 6.2(DBE2+DBE3)-5000 6.2(DBE3+DBE4)+3000
U/D SUPPORT DETAIL (mm) MID SUPPORT DETAIL A VIEW (REMOVED MID SUPPORT) --
3500<H≤6000 2 11H+38000 11H+50000 -- --
6000<H≤12000 3 5.5DBS1+10000 5.5DBS2+16000 5.5DBE+7000 -- --
10000<H≤12000 3 6DBS1+12000 6DBS2+22000 6DBE+7000 -- --
4
12000<H≤15000 4 6DBS1+12000 6DBS3+22000 6(DBE1+DBE2)+7000 6(DBE2+DBE3)+7000 --
15000<H≤22000 5 6.2DBS1+6000 6.2DBS4+19000 6.2(DBE1+DBE2)-4000 6.2(DBE2+DBE3)-5000 6.2(DBE3+DBE4)+3000
S900T Travelator layout

Done by owner or builder

◎This drawing is fit for the products with rise 1.5m≤H≤6m,the permitted tolerance for rise is -15mm~+15mm;The permitted tolerance for
level length is 0~+15mm.
◎When the level length L>15.3m, the intermediate support base is needed.
◎Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the sthengh is
enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
CLEAR FLOOR ACCESS AREA ◎The pit should be water-proof, and the location of plash should be set at the corner.
◎The pit drain hole should be connected with the drainage system, the work should be done by others.
◎According to the requirement of the technical data, the power supply with safety switch is set at the machine room.The fluctuation
2XC

Min 500
C

of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is not more
than 4Ω.
MIN 500mm OTHERWISE DEFLECTOR(BY OTHERS) ◎Use 10mm2 soft line as the power input cable, done by others.
Min 2000

Min 2500 ◎When the space between handrail center line and other barrier is less than 500mm, a guard plate without sharp edge should be set
above outter deck plate, and the height should not less than 300mm.
◎If there is any special requirement,the contract should be made after approved by the company technical depaprtment

Distance between supports (DBE)


60KN 60KN 60KN C
Dia 100mm hole for hoisting(by others) Dia 100mm hole for hoisting(by others)
B Up escalator(if there is)
A
WELL RAIL
(BY OTHERS)
F Min LS
Dia 100mm hole for DIM. S TO BE DETERMINED ON SITE
hoisting(by others)
RU
S
Min 2300

ADOPT 10mm2 SOFT WIRE CABLE AS

H
THE POWER SUPPLY CABLE.
RM2 (BY OTHERS)
Bottom escalator
Note: If the escalator is up and bottom

≥2300
RM1
H2

RD
H1

arrangement, it is required to have 2300mm


a
Mn P

clear space above the bottom escalator. Refer


Before or after installation, this area should to the dash area in the left. Any questions, pls
Min AB not have any barrier. contact SWORD technical department.
L1=L/3 (4 columns) L2=L/3 (4 columns)
L1=L/2 (3 columns)
E
D
400

Gaps filled with mastic (by others)


250

200 40
Steel plate Steel plate
D-50

30×400×400
D

Finished floor level 30×400×400


(By others) (By others) Speed Rise Step Width Span Other dimensions(mm)
Angle(a) Reaction(KN)
125

400 (m/s) H(mm) A(mm) L(mm)


AB LS F B C D E P
STEP WIDTH
800 1037 1330 1430 1300 (mm) 1000 800
10° 5.6713H+2866 5600 14898 5.6713S 1054
400

Steel plate30×180×D 1000 1237 1530 1630 1500 REACTIONS


(KN)
(by others) No.of RU RD RM1 RM2 RU RD RM1 RM2
Foot bolt φ16×150
Full length of support nose to be true level 800 1037 1330 1430 1300 supports
11° 0.5 1500≤H≤6000 5.1446H+2902 5060 13747 5.1446S 1054
500 500 1000 1237 1530 1630 1500 2 4.9L+6.2 4.9L+14 4.25L+8.2 4.25L+18
800 1037 1330 1430 1300 3 2.2L+5 2.2L+14 6.1L+4.2 1.9L+8 1.9L+17 5.2L+8.2
12° 4.7046H+2938 4650 12790 4.7046S 1054
U/D Support Detail MID Support Detail MID Support Detail
1000 1237 1530 1630 1500 4 1.5L+6 1.5L+15 3.45L+5 3.45L+5.2 1.3L+9 1.3L+17 3.1L+9.2 3.1L+10

NOTE:DO NOT SCALE THIS DRAWING,UNLESS OTHERWISE STATED.

You might also like