SWORD Escalator Travolater S900E S900T Giantliftslimited
SWORD Escalator Travolater S900E S900T Giantliftslimited
SWORD Escalator Travolater S900E S900T Giantliftslimited
S900T Travelator
Escalators, travelator have been painted the flowing landscape in the buildings. Hangzhou SWORD
Elevator Co., Ltd in the building products, not only considers the traditional elements of safety, energy
saving, comfort, quiet, but also seeks to coordination and interaction with the building, completeness
and convenience of functions. Because of this, many airports, transportation hubs, shopping malls
select the S900E, S900T products of Hangzhou SWORD elevator.
Precision, Energy-saving
Control System
DELICATE
Delicate parts, perfectly embodies the art
Truss Handrail
扶手带标准色(国产)
Standard color
Truss is welded of rectangular tube materials; A variety of professional design, stylish and durable
with seal welded bed plate to ensure that water handrail can be flexibly selected according to different
and oil stain will not leak from the bed plate. With environment.
hard stability and bearing capacity, it can effectively
extend the life of escalators.
扶手带可选色(合资)
Optional color
Aluminum Alloy Step Shoe Brake
The surface of pallets sprays the black electrophoretic Shoe brake is placed between the motor and
paint, hard texture, oxidation resistance, easy gear box, with the reliable and easily regulative
maintenance. Engrave antiskid patterns, embed characteristic, can guarantee a smooth braking
with a yellow warning on both sides. performance and (security) braking distance.
Adopting galvanized steel rail、high strength and good Use computer-controlled automatic lubrication
wear resistanse polyurethane roller and high strength system, no need full-time staff refuel, and ensure
plate chain, offering products the ability of resistance to control a moderate amount of the fuel.
to corrpsion and making life longer.
S900E Public Escalator Peak Performance Masterpiece of Sword
Improve system security, peace of mind, rest assured, Protection for broken handrail
comfortable Apron protection safety switch
Detection for over-worn brake shoe
Additional brake (>6m standard specification)
Oil level alarm switch
This type of escalator/travelator adopted the comprehensive safety protective measures,
Step lighting
and basically eliminate all sorts of accident happening
Comb lighting
Basic function Optional function
Select the Running Direction The entrance of escalators and moving walk operating box has a key switch control, the Running Direction Indicator It is equipped with luxurious running direction indicator lamp at the entrance, make the escalator,
panel has " " mark which is easy to operate. With the dedicated key following the Lamp travelator more elegant and noblest.
escalator you can select the running direction as required.
Skirt Lighting Install on the both sides of skirt panel, streamlined line high brightness lighting along the
Warning before Startup Inspection operation is without warning, warning before the normal startup, the bell rings for escalator will not only improve the security, but also enhance the elegant temperament of
3 seconds, and then type Y starts, after 3 seconds, type △ normally operates, the ring building inside environment.
disappears. Before and after the startup if there are unusual circumstances, you can press
the emergency stop button of operating panel, to put an end to start.
Balustrade Lighting Install inside the balustrade bracket, can attract passengers more stable holding the handrail,
like the skirt panel lighting, can enhance the temperament of building inside environment.
Automatic Lubrication Use computer-controlled automatic lubrication system, don’t need full-time staff refuel,
and ensure to control a moderate amount of the fuel.
Oblique Balustrade Mainly apply to the transportation hubs of large people flow and load bearing pressure and
other places, can maximally extend the space and comfort of the escalator, while improve
Automatic Fault Display Maintain a constant monitoring of machine running condition, when there is a fault, it the security of passengers.
displays the fault location timely on the nixie tube, allows service personnel to find fault
immediately and easy to maintain, reduces the downtime.
Step Warning Light The top and bottom of step pallets is equipped with the warning light, it can make the passengers
distinguish the stagger and leveling condition of step, improve the security of escalator.
Inspection Inching In order to easy to maintain and repair the escalator, travelator, the escalator and travelator
has the function of inspection inching. Insert the inspection plug into the any of inspection
outlet of upper and under machine room, the escalator, travelator then goes into an
inspection condition. All safety switches of escalator, travelator function the same as normal
operation in an inspection condition.
Host Speed Testing In order to ensure the safety of passengers, when the running speed of escalator, travelator
is 20% faster than the rated speed, the escalator, travelator will automatically stop operating,
and start running after professional disposes.
Motor Protection Function In order to guarantee the safety of equipment, the escalator, travelator has the function of
motor overheating protection, phase failure protection, etc.
Frequency Conversion Select the dedicated inverter to control the escalator, travelator’s running, run in the low-
Function(Only Escalators) speed condition of 0.2m/s without people; When the infrared device of the entrance detect
a person walk into the front pallets area of escalator, travelator, the escalator, travelator runs
in the normal condition of 0.5m/s, energy saving can reach to 40%-60%, and reduces the
peak current 50%-80%, to make the mechanical wear reduced.
Skirt Panel Brush Install on the both sides of skirt panel, avoid the shoes, shoelaces to scuff or involve in the
(Only Domestic) skirt panel, improve the security.
S900E Commercial Escalator layout
Done by owner or builder
◎ This drawing is fit for the products with rise 3m≤ H≤ 8m,the permitted tolerance for rise is -15mm~+15mm;The permitted
tolerance for level length is 0~+15mm.
◎When the level length L>15.3m, the intermediate support base is needed.
Clear floor access area
(both upper and lower landing) ≥2000 ◎ Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the
Min500
sthengh is enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
◎The pit should be water-proof, and the location of plash should be set at the corner.
◎The pit drain hole should be connected with the drainage system, the work should be done by others.
2×C
C
◎ According to the requirement of the technical data, the power supply with safety switch is set at the machine room. The
fluctuation of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is
not more than 4Ω.
≥2500
◎Use 10mm2 soft line as the power input cable, done by others.
◎When the space between handrail center line and other barrier is less than 500mm, a guard plate without sharp edge should be
set above outter deck plate, and the height should not less than 300mm.
Hole for lifting or hook(by others)
◎If there is any special requirement, the contract should be made after approved by the company technical depaprtment
100
L
F >AK
RU
Up escalator(if there is)
S
100
≥2300
C
Bottom escalator
RM B
≥2300
A Note: If the escalator is up and bottom arrangement, it is
required to have 2300mm clear space above the bottom
HM
Before or after installation, this area should escalator. Refer to the dash area in the left. Any questions,
RD not have any barrier. pls contact SWORD technical department.
a
AM min
MinAH
L1=L/2
Drainage hole
H
EDGE OF TRUSS
35° 0.5 3000≤H≤6000 2 800 1300 1.428S 4.41L+15 4.41L+9
1.428H+4905 4060 5950 1037 1330 1440 For Indoor, 1103 Without Shock
30×400×400
108
(By others)
◎ This drawing is fit for the products with rise 1.5m≤ H≤ 6m,the permitted tolerance for rise is -15mm~+15mm;The permitted
tolerance for level length is 0~+15mm.
≥ 2000 CLEAR ACCESS AREA (BOTH U/D LANDING) ≥ 2000
◎When the level length L>15.3m, the intermediate support base is needed.
◎Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the sthengh is
enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
◎The pit should be water-proof, and the location of plash should be set at the corner.
2*C
2*C
C
C
◎The pit drain hole should be connected with the drainage system, the work should be done by others.
◎ According to the requirement of the technical data, the power supply with safety switch is set at the machine room. The
fluctuation of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is
≥ 2500 ≥ 2500 not more than 4Ω.
◎Use 10mm2 soft line as the power input cable, done by others.
◎When the space between handrail center line and other barrier is less than 500mm, a guard plate without sharp edge should be set
HOISTING HOLE
above outter deck plate, and the height should not less than 300mm.
C
( ≥70KN, BY OTHERS)
B ◎If there is any special requirement, the contract should be made after approved by the company technical depaprtment
SAFETY FENCE A
(BY OTHERS)
100
L
SAFETY FENCE
(BY OTHERS) F >AK
≥ 1200
RM2
H
Bottom escalator
≥2300
HM2
RD
Before or after installation, this area should
not have any barrier. space above the bottom escalator. Refer to the
AM min
FINISHED FLOOR Angle Speed Rise Step Width Span Other dimensions(mm) Reaction(KN)
Flat Steps AM (mm) DA (mm)
(a) (m/s) H(mm) A(mm) L(mm)
300
AB AK B C D E F RU RD RM1 RM2
200 40 EMBEDDED STEEL PLATE 1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
3 1.732H+6576 4900 7750
30*200*300mm (BY OTHERS) 800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
30° 0.5,0.65 3,000~15,000 1.732S indoor
1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10 (without
DA
800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10 Oil water
220
separator)
1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
3 1.937H+6461 5050 8200
200 800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
27.3° 0.5,0.65 3,000~15,000 1.937S 150
1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
4 1.937H+7261 5450 8600
800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
300
outdoor
Y-BOLT Ø16*150 EMBEDDED STEEL PLATE 1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10 (with Oil
30*200*D (BY OTHERS) 3 2.333H+6287 5300 9010 water 1330
800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
23.2° 0.5,0.65 3,000~15,000 2.333S separator)
300 1000 1237 1580 1580 1550 4xL3+21.5 4xL1+1.5 5.5x(L1+L2)+10 5.5x(L3+L2)+10
4 2.333H+7087 5700 9410
800 1037 1380 1380 1350 3.7xL3+21.5 3.7xL1+1.5 5.2x(L1+L2)+10 5.2x(L3+L2)+10
U/D SUPPORT DETAIL(SYMMETRIC) MID SUPPORT DETAIL MID SUPPORT DETAIL (PLAN VIEW) NOTE:DO NOT SCALE THIS DRAWING,UNLESS OTHERWISE STATED.
S900E Heavy Public Escalator layout Done by owner or builder
◎ This drawing is fit for the products with rise 1.5m≤ H≤ 6m,the permitted tolerance for rise is -15mm~+15mm;The permitted
tolerance for level length is 0~+15mm.
◎When the level length L>15.3m, the intermediate support base is needed.
◎Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the sthengh is
enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
LL+160 LU+160
◎The pit should be water-proof, and the location of plash should be set at the corner.
◎The pit drain hole should be connected with the drainage system, the work should be done by others.
◎According to the requirement of the technical data, the power supply with safety switch is set at the machine room.The fluctuation
of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is not more
T
DBE =LL+LS+LU M
LL LS=1.732H LU
N
Up escalator(if there is)
SAFETY FENCE
>3984+1.732S HU ≥2500 (BY OTHERS)
SAFETY FENCE (BY OTHERS)
P
SITE SURVEY
≥ 1200
R2000
1000
VERTICAL FENCE
(BY OTHERS)
W.P. ◎Install retention devices, anti-skid devices, anti-
S
BARRIER creep devices etc after installation (by others).
700
(CEILING ETC.)
UPPER POWER SOURCE (BY OTHERS)
A
Bottom escalator ◎Vertical fences must be established if any barrier
≥2300
≥ 2300
842
within 400mm of handrail center line. min. height of
40 vertical fences 300mm (by others).
C Before or after installation, this area should ◎ If escalator vertical height is above 22000mm, or
H
R20
≥2500 HL not have any barrier. civil dimensions differ from above requirement,
00
3 3 3 3 3
B
40
HM1=0.5x(DBS1-LL)-1.155xC-220 A 1400 1400 1400 1400 1400 1400 1400 1400 1600 1600
HM2=0.5x(DBS1+DBS2-LL)-1.155xC-220 B 1300 1300 1150 1150 1150 1150 1150 1150 1150 1150
HM3=0.5x(DBS1+DBS2+DBS3-LL)-1.155xC-220 C 1480 1480 980 980 1180 1180 980 980 980 980
DRAIN HOLE IF OUTDOOR
(BY OTHERS) LA min HU 2665 3065 2665 3065 2890 3290 2890 3290 2890 3290
LU 3680 4080 3680 4080 3905 4305 4405 4805 4405 4805
DBS1 DBS2 DBS3 DBS4 Q
HL 2280 2680 2280 2680 2280 2680 2280 2680 2280 2680
R min LL 2880 3280 2880 3280 2880 3280 2880 3280 2880 3280
R1 R3 R3 R3 R3 AM 1600 1600 1450 1450 1450 1450 1450 1450 1450 1450
LA 3080 3080 2080 2080 2480 2480 2080 2080 2080 2080
DBS1 -- -- 1/2DBE 1/2DBE 1/2DBE 1/2DBE 1/3DBE 1/3DBE 1/4DBE 1/4DBE
DBS2 -- -- 1/2DBE 1/2DBE 1/2DBE 1/2DBE 1/3DBE 1/3DBE 1/4DBE 1/4DBE
DBS3 -- -- -- -- -- -- 1/3DBE 1/3DBE 1/4DBE 1/4DBE
DBS4 -- -- -- -- -- -- -- -- 1/4DBE 1/4DBE
Remarks: LU, LL in above sheet are min. value, and can be prolonged. Max. LU 6000, Max. LL 5000. Otherwise please contact SWORD.
A
300
Reaction:(N)
300
◎This drawing is fit for the products with rise 1.5m≤H≤6m,the permitted tolerance for rise is -15mm~+15mm;The permitted tolerance for
level length is 0~+15mm.
◎When the level length L>15.3m, the intermediate support base is needed.
◎Before installation, all holes have to be enclosed with the safety guard which height is not less than 1.2m and guarantee the sthengh is
enough.
◎After finish installation, the owner should consider to set safety guard rail around the escalator.
CLEAR FLOOR ACCESS AREA ◎The pit should be water-proof, and the location of plash should be set at the corner.
◎The pit drain hole should be connected with the drainage system, the work should be done by others.
◎According to the requirement of the technical data, the power supply with safety switch is set at the machine room.The fluctuation
2XC
Min 500
C
of voltage should not more than±7%. The zero line and ground line should be seperated and the ground resistance is not more
than 4Ω.
MIN 500mm OTHERWISE DEFLECTOR(BY OTHERS) ◎Use 10mm2 soft line as the power input cable, done by others.
Min 2000
Min 2500 ◎When the space between handrail center line and other barrier is less than 500mm, a guard plate without sharp edge should be set
above outter deck plate, and the height should not less than 300mm.
◎If there is any special requirement,the contract should be made after approved by the company technical depaprtment
H
THE POWER SUPPLY CABLE.
RM2 (BY OTHERS)
Bottom escalator
Note: If the escalator is up and bottom
≥2300
RM1
H2
RD
H1
200 40
Steel plate Steel plate
D-50
30×400×400
D