248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 2 30.04.2015 14:02:42
Setup
Noninvasive use
3 4
5
1
Invasive use
Antibacterial filter Catheter mount**
ResMed Leak Valve
HMEF*
2 2
5
1 5
1 3
3 7
6
6
4
4
*If not using an external humidifier, connect the HMEF to the ResMed Leak Valve.
** The ResMed Leak Valve or the HMEF can be connected to standardised tracheostomy interfaces
including connector pieces like catheter mounts.
The catheter mount and the external humidifier are not part of the ResMed component.
248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 3 30.04.2015 14:02:50
About the control panel
External power supply LED Mains power LED LCD screen
On when external battery is On when operating on mains power.
connected. Menu button
Navigate through the menus
Internal battery LED Monitoring
On when internal battery is in use. Setup
Flashes when device is turned off Info
and battery is charging.
Push dial (rotate/click)
•• Navigate through settings.
Alarm LED •• Change settings’ values.
Red or yellow during an alarm •• Enter and confirm your
condition or during alarm testing. selection.
Therapy LED
Alarm mute button LED
• On during treatment
On when is pressed.
• F lashes during mask fitting
operation.
Alarm mute button
Start/Stop button
•• Silence the alarm
• Clear the alarm message (low •• Start/Stop ventilation
priority alarms). • Start mask-fit (hold down for at
least three seconds).
Rear panel
Oxygen inlet
248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 4 30.04.2015 14:02:55
Turning the ventilator on/off
o turn the ventilator on, press the power switch at the rear of the device. Wait until the Treatment screen
T
is displayed.
o turn the ventilator off, press the power switch at the rear of the device. Follow the onscreen
T
instructions.
Treatment settings
Program
Ramp time
Warm-up humidifier
External Humidifier
4
248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 5 30.04.2015 14:02:58
Using the menus
Menu overview
Monitoring Leak
MV/Resp Rate
or MV/Va (iVAPS Tidal Volume
Mode)
I:E Ratio
Tidal Volume
Pressure Support
Synchronisation
AHI
Oximetry
SpO2
Used Hours
Device Information
Reminder
248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 6 30.04.2015 14:02:58
Overview Clinical Settings
SETUP
CPAP Mode
S Mode
ST Mode
T Mode
iVAPS Mode
PAC Mode
248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 7 30.04.2015 14:02:58
Overview Alarm Settings and Options
SETUP
Alarm Settings
248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 1 30.04.2015 14:02:58
Pathology defaults
IPAP [cm H 2 O] 13 11 16 11
PS [cm H 2 O] 8 6 8 6
Min PS [cm H 2 O] 4 4 4 2
Max PS [cm H 2 O] 20 20 18 20
MANUFACTURER DISTRIBUTED BY
ResMed Germany Inc. ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia
Fraunhoferstr. 16 ResMed Corp 9001 Spectrum Center Blvd San Diego CA 92123 USA
82152 Martinsried Germany ResMed (UK) Ltd 96 Jubilee Ave Milton Park Abingdon Oxfordshire OX14 4RW UK
See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip. ResMed and Stellar are
trademarks of ResMed Ltd. ResMed and Stellar are registered in U.S. Patent and Trademark Office.
© 2015 ResMed Ltd. 248804/1 2015-05
ResMed.com
248804r1 Stellar 100 & 150 Quick Setup Guide ROW ENG.indd 1 30.04.2015 14:02:41
Designed for versatility
Stellar series
Non-invasive / invasive ventilators
Stellar specifications Accessories
Modes iVAPS (intelligent Volume-Assured Pressure Support) with AutoEPAP*
H4i Heated Humidifier
ST (Spontaneous–Timed) 24930
PAC (Pressure Assisted Control) H4i water chamber
CPAP (Continuous Positive Airway Pressure) (disposable tub)
26952
S (Spontaneous)
Hospital Home T (Timed)
Pressure range IPAP: 2–40 cm H 2 O tellar DC–DC converter
S
EPAP: 2–25 cm H 2 O 24922
Easy to set up and use, Stellar carefully strikes a balance between ResMed Germany Inc. Fraunhoferstr. 16 82152 Martinsried Germany Stellar Distributed by: ResMed (UK) Ltd, 96 Jubilee Ave, Milton Park, Abingdon, Oxfordshire OX14 4RW. See ResMed.
providing you with pre-programmed settings that make your job easier, ResMed Humidification Technologies GmbH Karneolstr. 4 HumiCare D900 com for ResMed locations worldwide. CounterStream, H4i, HumiCare, ResScan, Stellar and TiControl are trademarks and/
or registered trademarks of the ResMed family of companies. For patent information, see ResMed.com/ip. Specifications
72250 Freudenstadt Germany
and the opportunity to fine-tune settings when needed to suit each ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia All others may change without notice. Product availability may vary across regions. © 2015 ResMed Ltd. 1018255/2 2015-07