VFD Trainer With Motor Features:: Siemens
VFD Trainer With Motor Features:: Siemens
VFD Trainer With Motor Features:: Siemens
Features:
0.75 KW / 1 HP Variable Frequency Drive with 1Ø, 230V, 50Hz supply.
Drive & Motor should be from same brand only
Specifications:
9 Digital Inputs
2 Analog Inputs
3 Digital Outputs
2 Analog Outputs
RS485 Communication port
Software Functions:
Signal interconnection with BICO technology
Automatic restart after line supply
Failure or Operational fault
Positioning down ramp
Slip compensation
Free function blocks (FFB) for logic and arithmetic operations
Ramp smoothing
3 selectable drive data sets
3 selectable command data sets (CDS) (manual/auto)
Flying restart
JOG
Technology controller (PID)
Thermal motor protection
Thermal inverter protection
Set point input
Motor identification
Motor holding brake
Vdcmax controller
Kinetic buffering
Braking functions for
DC braking
Compound braking
Dynamic braking
0.5HP 3Ø Induction Motor
440V AC
1440 RPM
IP55
0.5HP DC Machine
Shaft Encoder
550 PPR / Proximity sensor
Projected Shaft / Geared Teeth
A, B, Z
PNP Type, 24V
Mechanical Structure
MS structure
Aligned installation of AC motor and Shaft encoder
Electrical terminal strip
Electrical Panel
VFD mounting
Loading Arrangement
Motor-Generator Set
Suggested Experiments:
Study of variable frequency drive and its control and power wiring.
Study of AC drive parameters
Interfacing AC drive with digital inputs
Interfacing AC drive with analog inputs.
Study of V/F control modes of operation of AC drive with load.
Study of Encoder interfacing with VFD.
Yaskawa
VFD Trainer with Motor
Features:
0.75 KW / 1 HP Variable Frequency Drive with 3Ø, 400V, 50Hz supply
Drive & Motor should be from same brand only
Specifications:
8 Digital Inputs
3 Analog Inputs
1 Pulse Inputs
4 Digital Outputs
2 Analog Outputs
1 Pulse Outputs
RS485 Modbus RTU Communication
Control Methods:
V/f Control/f Control with PG (encoder), Open Loop Vector Control, Closed Loop
Vector Control, Open Loop Vector Control for PM, Advanced Open Loop Vector
Control for PM, Closed Loop Vector Control for PM.
Main Control Functions:
Torque Control, Droop Control, Speed/torque Control Switching, Feed Forward
Control, Zero Servo Function, Momentary Power Loss Ride-Thru, Speed Search,
Over torque/Under torque Detection, Torque Limit, 17 Step Speed (max),
Acceleration/deceleration Switch, S-curve Acceleration/deceleration, 3-wire
Sequence, Auto-tuning (rotational, stationary tuning), Dwell, Cooling Fan on/off
Switch, Slip Compensation, Torque Compensation, Frequency Jump, Upper/lower
Limits for Frequency Reference, DC Injection Braking at Start and Stop, Over
excitation Braking, High Slip Braking, PID Control (with sleep function), Energy
Saving Control, Modbus Comm. (RS-422/485 max, 115.2 kbps), Fault Restart,
Application Presets, DriveWorksEZ (customized function), Removable Terminal
Block with Parameter Backup Function, Online Tuning, KEB, Over Excitation
Deceleration, Inertia (ASR) Tuning, Overvoltage Suppression, High Frequency
Injection.
Shaft Encoder
550 PPR / Proximity sensor
Projected Shaft / Geared Teeth
A, B, Z
PNP Type, 24V
Mechanical Structure
MS structure
Aligned installation of AC motor and Shaft encoder
Electrical terminal strip
Electrical Panel
VFD mounting
Loading Arrangement
Motor-Generator Set
Suggested Experiments:
Study of variable frequency drive and its control and power wiring.
Study of AC drive parameters
Interfacing AC drive with digital inputs
Interfacing AC drive with analog inputs.
Study of V/F control modes of operation of AC drive with load.
Study of Encoder interfacing with VFD.
Delta
VFD Trainer with Motor
Features:
0.75 KW / 1 HP Variable Frequency Drive with 3Ø, 380 to 480 Volts AC, 50Hz
supply.
Drive & Motor should be from same brand only
Specification:
Analog input terminals (AVI, ACI, AUI, ACM)
Digital inputs (FWD, REV, MI1~MI6, DCM)
Digital outputs-photo coupler (MO1, MO2, MCM)
Digital outputs-relayed (RA,RB,RC,MRA,MRB,MRC)
Analog output meter (AFM)
Control Characteristics:
Control System
V/f curve
V/f+ PG (Encoder)
SVC(Sensor less vector control)
FOC vector control+PG(Encoder)
TQR(Torque control)+PG(Encoder)
V/f Curve Adjustable V/f curve using 4 independent points and square curve
Frequency Setting Signal±10V, 4~20mA, pulse input
Braking Type: DC Injection; Dynamic Braking Motor Control-Max Level: Closed
Loop Vector
Shaft Encoder
550 PPR / Proximity sensor
Projected Shaft / Geared Teeth
A, B, Z
PNP Type, 24
Mechanical Structure
MS structure
Aligned installation of AC motor and Shaft encoder
Electrical terminal strip
Electrical Panel
VFD mounting
Loading Arrangement
Motor-Generator Set
Suggested Experiments:
Study of variable frequency drive and its control and power wiring.
Study of AC drive parameters
Interfacing AC drive with digital inputs
Interfacing AC drive with analog inputs.
Study of V/F control modes of operation of AC drive with load.
Study of Encoder interfacing with VFD.