PERKINS 825-1250 kVA: Technical Specifications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PERKINS 825-1250 kVA

Technical Specifications
• The alternator windings are protected by insulating varnish against
oil and acid.
EXTRA EQUIPMENTS
• Charge ammeter
• Moulded case circuit braker (in automatic models)
• Hospital/Critical type silencer
• Sound-proof canopy
• Mobile - trailer
• Synchronization control panel for 2-16 gensets
• 3 pole/4 pole automatic transfer panel (A.T.S.)
• Fuel and oil heater
• Alternator heater
• Automatic fuel filling system
• Fuel-water seperator filter
• PMG warning system
CANOPY
• Modular type sound-proof canopy
• Canopy installation executed with screw and nut, without welding
process
• Epoxy and polyester powder painted canopy
ENGINE • Canopy designed for easy maintenance
• PERKINS series heavy duty diesel engine • Lockable doors on both sides of canopy
• 4 cycle, water cooled, turbocharged & air to air charge cooled • Emergency stop button
• Direct injection • Transparent panel inspection window
• Electronic governor system
• 24 volt self-starter and charger alternator
AUTOMATIC CONTROL PANEL
• LCD display screen • Hardware and materials needed
• Changeable air, fuel and oil filter
• Battery charger • USB port & RS-485 output
• Tropical type radiator
• Flexible fuel pipe GEN-SET SAFETY PROTECTION & ALARMS
• Oil discharge valve and extention pipe • High water temperature • Over current load
• Industrial type silencer, exhaust spiral or compensator • Low oil pressure • High & low genset voltage
• Maintenance free battery • High & low engine speed • Start/stop failure
• Engine block water heater (in automatic models) • Low radiator water level
• Diesel gen-set maintenance and operating instructions and Easy maintenance canopy design
electrical circuit diagram
QUALITY STANDARD Refilling from the outside of the canopy
Our generators are manufactured in compliance with VDE 0530,
BSE 4999 BS5000, IEC 34, TS ISO 8528, TS EN ISO 3744, TS EN ISO 3746,
TS EN 60034-1, TS EN 60204-1, TS EN 60335-1, TS EN 61439-1,
Canopy made of galvanized steel
EN 61000, TS EN ISO12100 standards.
We have ISO 9001:2008, ISO 14001:2004, OHSAS 18001:2007 and
ISO10002:2006 management system certificates from Kiwa & MEYER,
! Warning system for decreasing fuel with
electronic fuel level sender
an accredited independent quality organization.
Our generators up to 400 kw are manufactured in compliance with
2000/14/EC European noise emission directive and certified from Ente
Certificazione Macchine.
We also have TS ISO 8528-4, TS ISO 8528-5, TS EN 13501-1+A1:2013
flame retardancy and TS EN ISO 9227 certificates against anti-corrosion
together with CE Declaration.
ALTERNATOR
• Brushless, single bearing, flexible disc 4 poles alternator for
harmonic failure
• H type isolation class
• IP 21-23 protection class
• Self exciter
• Electronic automatic voltage regulator
• Stator 2/3 step for harmonic failure

16
PERKINS Series
Diesel Generator Sets

PERKINS Series Diesel Generator Sets 825-1250 kVA


MODEL E PR XX 0825 E PR XX 0900 E PR XX 1002 E PR XX 1125 E PR XX 1250
kVA 825 900 1002 1125 1250
STAND BY
kW 660 720 802 900 1000
GEN - SET POWER
kVA 750 800 911 1022 1125
PRIME
GROUP

kW 600 640 729 818 900

CANOPY DIMENSION (W x L x H) mm 1900 x 5250 x 3330 1900 x 5250 x 3330 2200 x 5550 x 3300 2200 x 5550 x 3300 2200 x 5550 x 3300

CANOPY WEIGHT kg 6525 6835 9635 9995 10025

OPEN DIMENSION (W x L x H) mm 1900 x 5000 x 2395 1900 x 5000 x 2395 2200 x 5300 x 2640 2200 x 5300 x 2640 2200 x 5300 x 2640

OPEN WEIGHT kg 5180 5490 8090 8450 8480

CONTAINER DIMENSION (W x L x H) mm 1900 x 5290 x 3640 1900 x 5290 x 3640 2200 x 5300 x 3390 2200 x 5300 x 3390 2200 x 5300 x 3390

CONTAINER WEIGHT kg 8100 8100 9700 9800 9800

BRAND PERKINS PERKINS PERKINS PERKINS PERKINS

TYPE 4006 - 23TAG2A 4006 - 23TAG3A 4008TAG1A 4008TAG2A 4008-30TAG3

STAND BY kW 695 760 855 958 1055


POWER
PRIME kW 632 679 778 872 947

SPEED (rpm) 1500 1500 1500 1500 1500

CYCLE 4 4 4 4 4

DISPLACEMENT (lt) 22,921 22,921 30,561 30,561 30,561

NUMBER OF CYLINDERS 6 IN LINE 6 IN LINE 8 IN LINE 8 IN LINE 8 IN LINE


ENGINE

BORE AND STROKE (mm x mm) 160 x 190 160 x 190 160 x 190 160 x 190 160 x 190

COMPRESSION RATIO 13,6 : 1 13,6 : 1 13,6 : 1 13,6 : 1 13,1 : 1

GOVERNOR TYPE ELECTRONIC

INDUCTION TURBOCHARGED - AIR TO AIR CHARGE COOLED

COMBUSTION SYSTEM DIRECT INJECTION

COOLING SYSTEM WATER

100% OF PRIME POWER 161,00 172,00 195,00 215,00 244,00


FUEL
CONSUMPTION 75% OF PRIME POWER 122,00 130,00 143,00 162,00 188,00
(lt/h)
50% OF PRIME POWER 83,00 90,00 98,00 111,00 120,00

TOTAL LUBRICATION SYSTEM CAPACITY (lt) 113,4 113,4 153 153 153

TOTAL COOLANT CAPACITY (lt) 105 105 149 149 140

FUEL TANK CAPACITY (lt) 1400 1400 2000 2000 2000

Emsa reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.

17

You might also like