250kva Cummins Diesel Generator Silent Type
250kva Cummins Diesel Generator Silent Type
250kva Cummins Diesel Generator Silent Type
WTC250GF Technical
Data
Cummins WTC-250GF
Quotation WT250GF
General feature:
♦ Assembled by Perkins diesel engine.
♦ Three filters as standard, fuel and water separator as optional.
♦ Radiator and fan with safety guard.
♦ Single bearing alternator IP 23, Insulation Class H.
♦ Heavy duty steel as base frame and 24hrs operation base fuel tank.
♦ Automatic control panel and 2 poles circuit breaker, internal cable.
♦ 12V battery, battery wires.
♦ Battery charger and float battery charger as standard supply scope.
♦ Soundproof canopy, meet IP23 class.
(1) PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in
accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period of
operation. In accordance with ISO 3046-1.
(2) ESP: The Standby Power Rating is applicable for supplying emergency power in variable load applications for up
to 200 hours per year in accordance with ISO8528-1. Overload is not allowed.
Telecom Series
WTC250GF Technical
Data
Engine Specifications
Manufacturer Cummins
Model 6LTAA8.9-G2
Prime power 220KW/275KVA
Standby power 240KW/300KVA
Speed 1500 rpm
Engine type Diesel, 4 strokes, water cooled, Turbocharged
Combustion type Direct injection
Cylinder type Wet liner
No. of cylinders 6
Bore x Stroke 114x 145 mm
Displacement 8.9 liters
Compression ratio 16.6:1
Governor Electric type
Feed pump Feed pump
Injection nozzle Multi hole type
Fuel filter Full flow, cartridge type
Oil pan capacity 27.6liters
Cooling water capacity 11.1liters
Starting motor 24V
Fuel consumption
75% 53l/h
100% 39l/h
Filters Air filter, Oil filter, Fuel filter, Fuel water separator
Telecom Series
WTC250GF Technical
Data
ALTERNATOR Specifications
Manufacturer Wetech
Model 314ESS
Prime power 200kw/250kva
Standby power 220kw/275kv a
Brushless, Self - Excited, Automatic Voltage
Type
Regulation (AVR)
Power factor 0.8
Speed 1500 rpm
Number of Phase 3
Voltage 400V
Insulation class H
Protection IP23
Voltage regulation ≤ ±1%
Frequency regulation ≤ ±5%
Overspeed 1 hour in a 6 hours 110% rated load
Cooling Air cooled by Fan
Control system
Capable AMF and Autostart ♦High frequency and low frequency
genset controller with 3 ♦Low fuel level
phases/single phase mains ♦Emergency stop
voltages and 3 phases/single ♦Fail to start
phase generator voltages and ① Power switch
Features:
currents monitoring. Integrated ♦Protection: Automatic start/stop, ② Lamp switch
J1939 Canbus interface to load transfer and alarming of ③ Power indicator
electronic engines, and traditional generator; ④ Operation buttons
interface for non-electronic ♦ CAN and magnetic pick-up ⑤ LCD display
engines. versions.
WETECH with its self-adjustable ♦ SMS Communication
contrast graphic display, and its (Start/Stop/Warning
user-friendly interface, provide failure/Shutdown failure/...)
you an instant visualization of the ♦PC and front panel configurable
measures and alarms coming ♦4 digital inputs and 3 analogue
from the genset. inputs.
The adjustable parameters of the ♦6 outputs(4 configurable on
controller allow the use of this magnetic pick-up, 6 configurable on
device for standard and Canbus version).
customized tasks, can be directly ♦1 phase or 3 phases generator an d
set with the controller’s keyboard, mains voltage monitoring.
or using the free software tool ♦remote start on or off load.
(BoardPrg3), available on ♦advanced metering capability.
SMARTGEN’ Website. ♦test button.
WETECH, in all versions, is able ♦protected solid state outputs.
to measure the mains frequency ♦transfer between mains and
and compute the mains power, generator power.
also when the load is connected ♦user-friendly set-up and button
to the mains itself. It’s also able to layout.
measure the neutral of mains and ♦multiple engine parameters are
generator voltages. Thanks to the monitored simultaneously.
separated push buttons, one for ♦module can be configured to suit
the MCB (Mains Circuit Breaker) individual applications.
and one for the GCB (Generator ♦IP 65 rating offers advanced
Circuit Breaker), the control of the resistance to water ingress when
genset in manual mode becomes gasket is fitted.
easier.
Telecom Series
WTC25GF Technical
Data
Supply scope
1.Standard supply scope:
Exhaust silencer
Starting battery
2. Optional supply scope:
⑧Elec.coolant Heater
⑥ Synchronization ⑦ Lub oil heater ⑩ Trailer &
System ⑨Oil drain Pump Silent Canopy