SWASTIK Single Compression type Heavy Duty Cable Gland
Indoor gland for single wire armored cable

Application
For use under most climatic conditions. These are weather proof and may be used in corrosive
conditions when protected by a shroud.

Specification
Gland consists of
1. Check-nut
2. Gland body
3. Metal Washers (2 Nos)
4. Outer seal rubber
5. Compression nut. All metal parts (Metal washers are in M.S.) are made of brass accurately
machined for ease of assemble.

Extras
Shrouds and Earth tags are supplied separately and should be specified when ordering the Gland.

Fitting Sequence
a. Screw item 2 into apparatus (secure with item 1, if plain hole entry).
b. Pass item 5,3 and 4 over cable before commencing to strip over sheath.
c. Remove the outer sheath to the desired length depending on the lengths of leads required.
d. Pass item 3 over the cable and spray out the amour wire one by one and then cut the
amour wires according to the size of washer. Inset the third metal washer over inner sheath
of cable so that bend amours are secured between the metal washer and gland body.
e. Push the cable through item 2 and engage the item 5 with item 2 and tighten up while doing,
so the grooved rubber ring will contract in radial direction and will grip the outer sheath of
cable.
SWASTIK Weatherproof type Double Compression Cable Gland
Indoor gland for single wire armored cable

Application
For use under most climatic conditions. These are weather proof and may be used in corrosive
conditions when protected by a shroud.

Specification
Gland consists of -
1. Check-nut
2. Gland body
3. Neoprene Inner Ring
4. Armour Clamping Cone
5. Armour Clamping Ring
6. Armour Clamping Nuts
7. Neoprene Outer Ring
8. Outer Seal Nut
All metal Parts are made of brass accurately machined for ease of assembly.

Extras
Shrouds and Earth tags are supplied separately and should be specified when ordering the Gland.

Fitting Sequence
a. Screw item 2 into apparatus (secure with item 1, if plain hole entry).
b. Pass item 8, 7 and 6 respectively over cable before commencing to strip over sheath.
c. Remove the over sheath and pass item 5. Cover exposed armour.
d. Cut armour to length, lift wire ends, pass item 4 over exposed bedding and beneath armour.
e. Pass item 3 over exposed bedding.
f. Pass cable end through item 2.
g. Engage item 6 and 2 and tighten up.
h. Engage item 8 and 6 and tighten up.
Tropodur armoured twin & multicore Power cable type
AYWY & AYFY 650/1100 V
FLANGE
SINGLE COMPRESSION TYPE DOUBLE COMRESSION TYPE
TYPE
Approx Nipple W e athe r Nipple
Me dium Fla nge Fla me proof
No. of Core s ove ra ll Hea vy Duty Entry proof Entry
Duty Type Type
diame ter Size Type Size
3½ x 25/16 sm/rm 26.0 1.1/8" 2932+2925 1¼" 1 SHW 04 SHF04 1.1/8"
3½ x 35/16 sm/rm 28.5 1¼" 2938+2929 1½" 1 SHW 05 SHF05 1¼"
3½ x 50/25 sm/rm 32.0 1.3/8" 3638+3631 1½" 11 SHW 06 SHF06 1.3/8"
3½ x 70/35 sm/rm 35.0 1½" 3638+3635 1½" 0 SHW 07 SHF07 1½"
3½ x 95/50 sm/rm 40.0 1¾" 4251+4240 2" 38 SHW 08 SHF08 1¾"
AYFY
3½ x 120/70 sm 43.0 1¾" 4251+4242 2" 001 SHW 08 SHF09 1¾"
3½ x 150/70 sm 48.0 2" 5451+5448 2" 001 SHW 10 SHF10 2"
3½ x 185/95 sm 52.0 1¼" 5463+5450 2½" 002 SHW 10 SHF10 1¼"
3½ x 225/120 sm 58.0 2½" 6063+6058 2½" 003 SHW 11 SHF11 2½"
3½ x 240/120 sm 61.0 2½" 6063+6060 2½" 0033 SHW 11 SHF11 2½"
3½ x 300/150 sm 66.0 2¾" 6675+6666 3" 0033 SHW 12 SHF12 2¾"
3½ x 400/185 sm 74.0 3" 7882+7874 3¼" 004 SHW 13 SHF13 3"
AYW Y
4 x 1.5 rc 16.5 ¾" 1619+1615 ¾" 5 SHW 01s SHF1s 5/8"
4 x 2.5 rc 17.5 ¾" 2119+2118 ¾" 4 SHW 01 SHF01 ¾"
4 x 4 rc 19.5 7/8" 2125+2120 1" 3 SHW 02 SHF02 7/8"
AYFY
4 x 6 rc 19.5 1" 2125+2120 1" 3 SHW 02 SHF02 1"
4 x 10 rc 21.5 1" 2125+2120 1" 2 SHW 03 SHF03 1"
4 x 16 rc 25.5 1.1/8" 2932+2925 1¼" 1 SHW 04 SHF04 1.1/8"
4 x 25 rc 26.0 1.1/8" 2932+2925 1¼" 1 SHW 04 SHF04 1.1/8"
4 x 35 rc 28.5 1¼" 2938+2929 1½" 1 SHW 05 SHF05 1¼"
4 x 50 rc 33.0 1.3/8" 3638+3633 1½" 11 SHW 06 SHF06 1.3/8"

Tropodur Unarmoured single core Power cable type


AYWY & AYFY 650/1100 V
SINGLE COMPRESSION TYPE DOUBLE COMRESSION TYPE
Approx Nipple Nipple
Medium Weatherproof Flameproof
No. of Cores overall Heavy Duty Entry Entry
Duty Type Type
diameter Size Size
1 x 4 8.5 5/8" 1616+1609 5/8" SHW 01S SHF01S ¾"
1 x 6 10.0 5/8" 1616+1611 5/8" SHW 01S SHF01S ¾"
1 x 10 11.0 5/8" 1619+1611 ¾" SHW 01S SHF01S ¾"
1 x 16 12.0 5/8" 1619+1613 ¾" SHW 01S SHF01S ¾"
1 x 25 14.0 ¾" 1619+1613 ¾" SHW 01S SHF01S ¾"
1 x 35 15.0 ¾" 1619+1615 ¾" SHW 01S SHF01S ¾"
1 x 50 16.5 1" 2125+2116 1" SHW 01A SHF01A 1"
1 x 70 19.0 1" 2125+2120 1" SHW02 SHF 02 1"
1 x 95 21.0 1.1/8" 2932+2921 1¼" SHW 04A SHF 04A 1¼"
1 x 120 23.0 1.1/8" 2932+2923 1¼" SHW 04A SHF 04A 1¼"
1 x 150 24.5 1¼" 2932+2925 1¼" SHW 04A SHF 04A 1¼"
1 x 185 27.0 1¼" 2938+2937 1½" SHW05 SHF 05 1¼"
1 x 225 29.5 1.3/8" 2938+2929 1½" SHW 05A SHF 05A 1½"
1 x 240 32.0 1½" 3638+3633 1½" SHW06 SHF 06 1½"
1 x 300 39.0 1¾" 3638+3635 1½" SHW07 SHF 07 1½"
1 x 400 39.0 2" 4251+4240 2" SHW08 SHF 08 2"
1 x 500 42.0 2" 4251+4240 2" SHW09 SHF 09 2"
1 x 625 47.0 2¼" 5463+5448 2½" SHW 10A SHF 10A 2½"
1 x 800 52.0 2½" 5463+5450 2½" SHW 10A SHF 10A 2½"
1 x 100 57.0 2½" 6063+6060 2½" SHW11 SHW 11 2½"
Tropodur Unarmoured single core power cable type AYY 650/1100 V
SINGLE COMPRESSION TYPE DOUBLE COMRESSION TYPE
Approx Nipple Nipple
Medium Weatherproof Flameproof
No. of Cores overall Heavy Duty Entry Entry
Duty Type Type
diameter Size Size
1 x 4 12.3 5/8" 1616+1613 5/8" SHW 01S SHF01S ¾"
1 x 6 12.8 5/8" 1616+1613 5/8" SHW 01S SHF01S ¾"
1 x 10 13.8 ¾" 1619+1613 ¾" SHW 01S SHF01S ¾"
1 x 16 15.3 ¾" 1619+1615 ¾" SHW 01S SHF01S ¾"
1 x 25 16.8 7/8" 2119+2116 ¾" SHW01 SHF01 ¾"
1 x 35 17.0 7/8" 1619+1618 ¾" SHW01 SHF01 ¾"
1 x 50 18.5 1" 2125+2120 1" SHW02 SHF02 1"
1 x 70 21.0 1" 2125+2120 1" SHW03 SHF03 1"
1 x 95 23.0 1.1/8" 2932+2932 1¼" SHW03 SHF03 1"
1 x 120 25.0 1.1/8" 2932+2925 1¼" SHW04 SHF04 1"
1 x 150 26.0 1.1/8" 2932+2925 1¼" SHW04 SHF04 1"
1 x 185 29.0 1¼" 2932+2929 1¼" SHW 05A SHF05A 1¼"
1 x 225 31.5 1.3/8" 3638+3631 1½" SHW06 SHF06 1½"
1 x 240 33.5 1.3/8" 3638+3633 1½" SHW06 SHF06 1½"
1 x 300 36.0 1½" 3638+3637 1½" SHW07 SHF07 1½"
1 x 400 41.0 1¾" 4251+4240 2" SHW08 SHF08 2"
1 x 500 43.0 2" 4251+4242 2" SHW09 SHF09 2"
1 x 625 49.0 2¼" 5451+5448 2" SHW10 SHF10 2"
1 x 800 54.0 2¼" 6063+6055 2½" SHW11 SHF11 2½"
1 x 100 59.0 2¼" 6063+6060 2½" SHW11 SHF11 2½"

Tropodur armoured twin & multicore Power cable type


AYWY & AYFY 650/1100 V
FLANGE
SINGLE COMPRESSION TYPE DOUBLE COMRESSION TYPE
TYPE
Approx Nipple W e athe r Nipple
Me dium Fla nge Flame proof
No. of Core s overall Hea vy Duty Entry proof Entry
Duty Type Type
dia mete r Size Type Size
AYW Y
2 x 1.5 15.0 ½" 1619+1615 ¾" 5 SHW 01S SHF04 ½"
2 x 2.5 16.0 5/8" 1619+1615 ¾" 5 SHW 01S SHF05 5/8"
2x 4 17.5 ¾" 2125+2118 1" 4 SHW 01 SHF06 ¾"
2x 6 18.5 7/8" 2125+2118 1" 4 SHW 01 SHF07 ¾"
2 x 10 20.5 1" 2125+2120 1" 3 SHW 02 SHF08 1"
AYFY
2 x 16 22.5 1" 2125+2120 1" 2 SHW 03 SGF09 1"
2 x 25 25.0 1.1/8" 2932+2120 1¼" 1 SHW 04 SGF10 1.1/8"
2 x 35 27.5 1¼" 2932+2937 1¼" 1 SHW 05 SGF10 1¼"
2 x 50 32.0 1.3/8" 3638+3631 1¼" 11 SHW 06 SGF11 1.3/8"
AYW Y
3 x 1.5 15.5 5/8" 1619+1615 ¾" 5 SHW 01S SHF01S ½"
3 x 2.5 17.0 ¾" 2125+2116 1" 4 SHF01S 5/8"
3x 4 18.0 ¾" 2125+2118 1" 4 SHW 01 SHF01 ¾"
3x 6 19.5 7/8" 2125+2120 1" 3 SHW 02 SHF02 7/8"
AYFY
3 x 10 20.5 1" 2125+2120 1" 3 SHW 02 SHF02 1"
3 x 16 23.5 1" 2925+2923 1" 2 SHW 03 SHF04 1"
3 x 25 23.5 1" 2925+2923 1" 2 SHW 04 SHF04 1"
3 x 35 25.5 1.1/8" 2932+2925 1¼" 1 SHW 04 SHF04 1.1/8"
3 x 50 29.0 1¼" 2932+2929 1¼" 1 SHW 05 SHF05 1¼"
3 x 70 33.0 1.3/8" 3638+3633 1½" 0 SHW 06 SHF06 1.3/8"
3 x 95 37.0 1½" 3638+3637 1½" 00 SHW 07 SHF07 1½"
3 x 120 40.0 1¾" 4251+4240 2" 38 SHW 08 SHF08 1¾"
3 x 150 43.0 1¾" 4251+4242 2" 001 SHW 09 SHF09 1¾"
3 x 185 49.0 2" 5451+5450 2" 002 SHW 10 SHF10 2"
3 x 225 54.0 2¼" 6063+6053 2½" 003 SHW 11 SHF11 2¼"
3 x 240 56.0 2¼" 6063+6065 2½" 003 SHW 11 SHF11 2¼"
3 x 300 62.0 2½" 6675+6662 3" 003 SHW 12 SHF12 2½"
3 x 400 68.0 2¾" 6675+6666 3" 004 SHW 13 SHF12 2¾"
SWASTIK Flameproof type Double Compression Cable Gland
Indoor gland for single wire armored cable

Application
For use under most climatic conditions. These are weather proof and may be used in corrosive conditions
when protected by a shroud.

Specification
Gland consists of
1. Check-nut
2. Gland body
3. Neoprene Inner Ring
4. Armour Clamping Cone
5. Armour Clamping Ring
6. Armour Clamping Nuts
7. Neoprene Outer Ring
8. Outer Seal Nut
All metal Parts are made of brass accurately machined for ease of assembly.

Extras
Shrouds and Earth tags are supplied separately and should be specified when ordering the Gland.

Fitting Sequence
a. Screw item 2 into apparatus (secure with item 1, if plain hole entry).
b. Pass item 8, 7 and 6 respectively over cable before commencing to strip over sheath.
c. Remove the over sheath and pass item 5. Cover exposed armour.
d. Cut armour to length, lift wire ends, pass item 4 over exposed bedding and beneath armour.
e. Pass item 3 over exposed bedding.
f. Pass cable end through item 2.
g. Engage item 6 and 2 and tighten up.
h. Engage item 8 and 6 and tighten up.
Tropodur armoured control cable type YWY & YFY 650/1100 V
FLANGE
SINGLE COMPRESSION TYPE DOUBLE COMRESSION TYPE
TYPE
Approx Nipple W ea ther Nipple
Me dium Flange Flam eproof
No. of Core s ove ra ll He avy Duty Entry proof Entry
Duty Type Type
diame ter Size Type Size
2 x 1.5 15.0 ½" 1616+1615 5/8" 5 CEW 01S CGF 01S ½"
3 x 2.5 15.5 5/8" 1619+1615 ¾" 5 CEW 01S CGF 01S ½"
4x 4 16.5 ¾" 1619+1616 ¾" 5 CEW 01S CGF 01S 5/8"
YW Y
5 x 1.5 17.0 ¾" 2119+2116 ¾" 4 CEW 01S CGF 01S 5/8"
6 x 1.5 18.0 ¾" 2119+2118 ¾" 4 CEW 01 CGF 01 ¾"
7 x 1.5 18.0 ¾" 2119+2118 ¾" 4 CEW 01 CGF 01 ¾"
10 x 1.5 20.0 1" 2125+2118 1" 3 CEW 02 CGF 02 1"
12 x 1.5 20.5 1" 2125+2120 1" 3 CEW 02 CGF 02 1"
14 x 1.5 20.5 1" 2125+2120 1" 2 CEW 02 CGF 02 1"
16 x 1.5 21.5 1" 2125+2120 1" 2 CEW 03 CGF 03 1"
19 x 1.5 21.0 1" 2125+2120 1" 2 CEW 03 CGF 03 1"
24 x 1.5 25.5 1.1/8" 2925+2125 1" 1 CEW 04 CGF 04 1.1/8"
YFY
27 x 1.5 26.0 1.1/8" 2932+2927 1¼" 1 CEW 04 CGF 04 1.1/8"
30 x 1.5 27.0 1.1/8" 2932+2927 1¼" 1 CEW 05 CGF 05 1¼"
37 x 1.5 29.0 1¼" 2928+2929 1½" 1 CEW 05 CGF 05 1¼"
44 x 1.5 33.0 1.3/8" 3638+3633 1½" 11 CEW 06 CGF 06 1.3/8"
52 x 1.5 34.0 1.3/8" 3638+3635 1½" 0 CEW 07 CGF 07 1½"
61 x 1.5 36.0 1½" 3638+3635 1½" 00 CEW 07 CGF 07 1½"
2 x 2.5 16.0 5/8" 1619+1615 ¾" 5 CEW 01S CGF 01S ½"
3 x 2.5 17.0 ¾" 2129+2116 ¾" 4 CEW 01S CGF 01S 5/8½"
4 x 2.5 17.5 ¾" 2119+2118 ¾" 4 CEW 01 CGF 01 ¾"
YW Y
5 x 2.5 19.0 7/8" 2125+2120 1" 4 CEW 02 CGF 02 7/8"
6 x 2.5 20.5 1" 2125+2120 1" 3 CEW 02 CGF 02 1"
7 x 2.5 20.5 1" 2125+2120 1" 3 CEW 02 CGF 02 1"
10 x 2.5 21.0 1" 2125+2120 1" 2 CEW 03 CGF 03 1"
12 x 2.5 21.0 1" 2125+2120 1" 2 CEW 03 CGF 03 1"
14 x 2.5 23.5 1.1/8" 2925+2923 1" 2 CEW 04 CGF 04 1"
16 x 2.5 24.5 1.1/8" 2925+2925 1" 2 CEW 04 CGF 04 1"
19 x 2.5 25.5 1.1/8" 2925+2925 1" 1 CEW 04 CGF 04 1.1/8"
24 x 2.5 29.5 1¼" 2938+2929 1½" 1 CEW 05 CGF 05 1¼"
YFY
27 x 2.5 30.0 1¼" 2938+2929 1½" 1 CEW 05 CGF 05 1¼"
30 x 2.5 32.0 1.3/8" 3638+3631 1½" 11 CEW 06 CGF 06 1.3/8"
37 x 2.5 34.0 1.3/8" 3638+3635 1½" 0 CEW 07 CGF 07 1½"
44 x 2.5 38.0 1½" 3638+3637 1½" 00 CEW 08 CGF 08 1½"
52 x 2.5 39.0 1¾" 4251+4240 2" 38 CEW 08 CGF 08 1¾"
61 x 2.5 42.0 1¾" 4251+4242 2" 38 CEW 09 CGF 09 1¾"

Authorised Dealer & Stockiest:

SINGHI SUPPLY SYNDICATE


54, EZRA STREET, SHOP: 51, GR FLR, KOLKATA 700001, PH: +91 33 22351819, 30210886, FAX: +91 33 22343887,
MOBILE: 9836620463, 9830032306, E-MAIL: bizliwala@ hotmail.com, WEB SITE: WWW.BIZLIWALA.COM
Tropodur armoured 3 core power cables type AYFY 1900/3300 V

FLANGE
SINGLE COMPRESSION TYPE DOUBLE COMRESSION TYPE
TYPE
Approx Nipple W ea ther Nipple
Me dium Flange Flam eproof
No. of Core s ove ra ll He avy Duty Entry proof Entry
Duty Type Type
diam e ter Size Type Size
3 x 25 29.0 1¼" 2938+2929 1½" 1 SHW 05 SHF05 1¼"
3 x 35 31.0 1¼" 3638+3631 1½" 11 SHW 06 SHF06 1¼"
3 x 50 34.0 1.3/8" 3638+3635 1½" 11 SHW 07 SHF07 1.3/8"
3 x 70 37.0 1½" 3638+3637 1½" 00 SHW 07 SHF07 1½"
3 x 95 41.0 1¾" 4251+4240 2" 38 SHW 08 SHF08 1¾"
3 x 120 44.0 1¾" 4251+4242 2" 001 SHW 09 SHF09 1¾"
3 x 150 47.0 2" 5451+5446 2" 001 SHW 10 SHF10 2"
3 x 150 50.0 2" 5463+5450 2½" 002 SHW 10 SHF10 2"
3 x 185 55.0 2¼" 6063+6055 2½" 003 SHW 11 SHF11 2¼"
3 x 225 56.0 2¼" 6063+6063 2½" 003 SHW 11 SHF11 2¼"
3 x 240 62.0 2½" 6675+6662 3" 0033 SHW 12 SHF12 2¼"
3 x 300 69.0 2¾" 7882+7870 3¼" 004 SHW 13 SHF13 2¾"
3 x 400 77.0 3¼" 7882+7877 3¼" 004 SHW 13 SHF13 3¼"
Trapodur armoured 3 core power cables type AYFY 3800/6600V
3 x 25 35.0 1.3/8" 3638+3635 1½" 0 SHW O7 SHF07 1.3/8"
3 x 35 37.0 1½" 3638+3637 1½" 00 SHW O7 SHF07 1.3/8"
3 x 50 40.0 1¾" 4251+4240 2" 38 SHW O8 SHF08 1¾"
3 x 70 44.0 1¾" 5451+5444 2" 001 SHW O8 SHF08 1¾"
3 x 95 47.0 2" 5451+5446 2" 001 SHW O10 SHF10 2"
3 x 120 50.0 2" 5463+5450 2½" 002 SHW O10 SHF10 2"
3 x 150 54.0 2¼" 6063+6063 2½" 003 SHW O11 SHF11 2¼"
3 x 185 57.0 2½" 6063+6057 2½" 003 SHW O11 SHF11 2½"
3 x 225 61.0 2½" 6063+6060 2½" 0033 SHW O11 SHF11 2½"
3 x 240 63.0 2½" 6675+6662 3" 0033 SHW O12 SHF12 2½"
3 x 300 67.0 2¾" 7882+7868 3¼" 0033 SHW O12 SHF12 2¾"
3 x 400 73.0 3" 7882+7872 3¼" 004 SHW O13 SHF13 3"
3 x 500 79.0 3¼" 7882+7878 3¼" 005 SHW O13 SHF13 3¼"
Trapodur armoured 3 core power cables type AYFY 6600V (UE grade)
3 x 25 38.0 1½" 3638+3637 1½" 00 SHW 08 SHF08 1½"
3 x 35 40.0 1¾" 4251+4240 2" 38 SHW 08 SHF08 1¾"
3 x 50 43.0 ¾" 4251+4242 2" 001 SHW 09 SHF09 ¾"
3 x 70 47.0 2" 5451+5446 2" 001 SHW 10 SHF10 2"
3 x 95 50.0 2" 5463+5460 2½" 002 SHW 10 SHF10 2"
3 x 120 51.0 2¼" 5463+5450 2½" 002 SHW 10 SHF10 2¼"
3 x 150 57.0 2¼" 6063+6057 2½" 003 SHW 11 SHF11 2½"
3 x 185 60.0 2½" 6063+6060 2½" 0033 SHW 11 SHF11 2½"
3 x 225 64.0 2¾" 6675+6664 3" 0033 SHW 12 SHF12 2¾"
3 x 240 66.0 2¾" 6672+6666 3" 0033 SHW 12 SHF12 2¾"
3 x 300 71.0 3" 7882+7870 3½" 004 SHW 13 SHF13 3"
3 x 400 76.0 3¼" 7882+7870 3½" 004 SHW 13 SHF13 3¼"
3 x 500 83.0 3½" 7882+7870 3½" 005 SHW 14 SHF14 3½"
Chart for selection of cable glands on the basis of cable overall
diameter for Weatherproof type cable glands
Cable dia (mm) Weatherproof Type Flameproof Type
From To
10.0 16.0 SHW 01S SHF 01S
16.5 18.0 SHW 01 SHF 01
18.5 20.0 SHW 02 SHF 02
20.5 23.0 SHW 03 SHF 03
13.5 26.0 SHW 04 SHF 04
26.5 30.0 SHW 05 SHF 05
30.5 33.0 SHW 06 SHF 06
33.5 37.0 SHW 07 SHF 07
37.5 41.0 SHW 08 SHF 08
41.5 46.0 SHW 09 SHF 09
46.5 52.0 SHW 10 SHF 10
52.5 60.0 SHW 11 SHF 11
60.5 66.0 SHW 12 SHF 12
66.5 78..0 SHW 13 SHF 13
78.5 84.0 SHW 14 SHF 14
84.5 92.0 SHW 15 SHF 15
92.5 104.0 SHW 16 SHF 16

For Single Compression type cable glands

Heavy duty type Medium duty type

Cable dia (mm) Suitable gland Cable dia (mm) Suitable gland
from to from to
10.0 16.0 1616/1619 8.0 14.0 1/2-5/8”
16.5 20.0 2125/2119 14.5 16.0 3/4”
20.5 29.0 2925/2932/2938 17.0 18.0 7/8”
29.5 37.0 3638 18.5 21.0 1”
38.0 42.0 4551 21.5 26.0 1.1/8”
42.5 50.0 5451/5463 26.5 30.0 1¼”
51.0 60.0 6063 30.5 34.0 1.3/8”
61.0 66.0 6675 34.5 38.0 1½”
67.0 78.0 7882 38.5 42.0 1¾”
42.5 48.0 2”
48.0 54.0 2¼”
54.0 60.0 2½”
60.5 66.0 2¾”
66.5 72.0 3”
73.0 78.0 3¼”