S118CY1 COMPRESSOR

TECHNICAL SPECIFICATION

HUANGSHI DONPER COMPRESSOR CO., LTD.


2021.3
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

INDEX

Page
1. Compressor Type........................................................................................................... 2

2. Performance Data .......................................................................................................... 2

3. Running Condition ........................................................................................................ 2

4. Compressor Mechanical Information............................................................................ 3

5. Compressor Shape ......................................................................................................... 3

6. Wiring Diagram ............................................................................................................. 4

7. Fixing of mounting bracket and cabinet base ............................................................... 5

8. Starting relay and overload protector ............................................................................ 5

9. Delivery State ................................................................................................................ 8

10. Package、Storage and Transportation ........................................................................ 9

11. Technical Items............................................................................................................ 9

Page 1 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

1. Compressor Type
Compressor model S118CY1
Rated voltage/frequency 220-240V~50Hz
Refrigerant R600a
Application Low back pressure(LBP)
Cooling method Static
Start torque Low starting torque(LST)
Control device Capillary tube
Motor type RSIR
Running capacitor /
Starting capacitor /

2. Performance Data
Displacement

Cooling Capacity(≥95%) COP(≥95%)


Oil Charge
Net Wt.

ASHRAE CECOMAF ASHRAE CECOMAF

-35 -30 -25 -23.3 -20 -15 -10 -25 -23.3 -25
cm3 kg ml w w w w w w w w w/w w/w
11.8 6.8±0.4 160±10 83 134 179 195 226 291 347 147 1.36 1.18
Note: These datas come from the test without a PTC relay

Testing condition:
LBP
Test conditions
ASHRAE CECOMAF
Evaporating Temp. -23.3℃ -25℃
Ambient Temp. +32.2℃ +32℃
Condensing Temp. +54.4℃ +55℃
Suction Temp. +32.2℃ +32℃
Subcooling Temp. +32.2℃ +55℃

3. Running Condition
Ambient temp. 0~43℃
Evaporating temp. -35~-15℃
Voltage range 187~254V
Max. condensing temp. 65℃
Max. winding temp. 120℃
Max. shell temp. 95℃
Max. discharge temp. 110℃
Start voltage 187V [0.3/0.3MPa(abs)]
Shell min. resistance to pressure 35bar
Page 2 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

4. Compressor Mechanical Information


Oil type Synthetic oil
Viscosity 4.2~6.4mm2/s(40℃)
Oil charged 160±10ml
Diameter of suction tube (I.D.) Φ6.2±0.1mm
Diameter of discharge tube(I.D.) Φ4.9±0.1mm
Diameter of process tube (I.D.) Φ6.2±0.1mm
Material of suction tube, process tube and
Copper tube
discharge tube
Compressor noise 41dB(A)
Vibration 0.7m/s2
Protecting gas Dry com.air(Dew point-60℃)

5. Compressor Shape

Caution:Suction tube and process tube can not be exchanged


Unmarked tolerance:±5mm
Unmarked Angle: ±10°

Page 3 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

6. Wiring Diagram

Separated type

Combo type

Note: Each of the starting relay、the overload protector、the cover and the earth bolt is separately
provided by our company.

Page 4 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

7. Fixing of mounting bracket and cabinet base

1、 Hexagon nut
2、 Spring washer
3、 Flat washer
4、 Compressor mounting bracket
5、 Rubber grommet
6、 Sleeve
7、 Cabinet base
8、 Screw

Note: Equipment assembly is all provided by our company. Above is just for reference, details
can refer to delivery state.

8. Starting relay and overload protector


8.1 Starting relay
Model JPQII-15 8EA19C1-02 QP2-15
Shunde Ronggui
Lanxi City Sensata
Electronic Circuit
Supplier Yueqiang Electric Technologies
MeasuringEquipmen
Co.,Ltd. (Baoying) Co., Ltd.
t Co. Ltd.
Resistance Ω 15
Run time S 0.2~1.5
Rese ttime S ≤100
Max working voltage V 350
Max current A 8
Assembly force≤100N Disassembly force≥25N
Flammability: Anti-flammability
QP2-15/ JPQⅡ-15 8EA19C1-02

Page 5 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

8.2 Overload protector


Model DRB22T69A2 BT62-140 TB62-140 3TM205TH1
Shunde
Hangzhou Star Ronggui
Lanxi City Sensata
shuaier Electronic
Yueqiang Technologies
Supplier Electric Circuit
Electric (Baoying) Co.,
Appliance MeasuringEqu
Co.,Ltd Ltd.
Co.,Ltd. ipment Co.
Ltd.
Max.T.C Amp.(25℃) A 6.2
Trip time S 5~15
Reset time S 30~150
Open temp. ±5℃ 140
Close temp. ±9℃ 69
Assembly force≤80N Disassembly force≥12.5N
Flammability: Anti-flammabilit

8.3 Combo starting relay and overload protector


8EA19C QPS2-B QP2-15 JPQⅡ
ZHB62- 1-02+3T 15MG1+ ZH+ -15 BK
Model
140P15 M205T DRB22T TB62-14 +BT62-1
H1 69A2 0 40
Shunde
Hangzho
Changsh Sensata Ronggui Lanxi
u Star
u Technol Electroni City
shuaier
Tianyin ogies c Circuit Yueqian
Supplier Electric
Electrom (Baoyin Measuri g
Applianc
echanica g) Co., ngEquip Electric
e
lCo. Ltd. Ltd. ment Co. Co.,Ltd
Co.,Ltd
Ltd.

Page 6 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

Resistance Ω 15±20%
Run time S 0.2~1.5
Starting
Reset time S ≤100
relay
Max working voltage V 350
Max current A 8
Max.T.C Amp.(25℃) A 6.2
Trip time S 5~15
Protector Reset time S 30~150
Open temp. ±5℃ 140
Close temp. ±9℃ 69
ZHB62-140P15 QPS2-B15MG1+DRB22T69A2

8EA19C1-02+3TM205TH1 QP2-15 ZH+TB62-140

JPQⅡ-15 BK +BT62-140

Page 7 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

9. Delivery State
No. Name Model Quantity CODE
1 Compressor S118CY1 1pcs
2 Φ6.4 1pcs
Rubber plug
3 Φ8.2 2pcs
4 Rubber grommet U model 4pcs
Lanxi City Yueqiang Electric
JPQII-15
Co., Ltd.
Sensata Technologies (Baoying) Co.,
5 Starting relay 8EA19C1-02 1pcs
Ltd.
Shunde Ronggui Electronic Circuit
QP2-15
MeasuringEquipment Co.,Ltd.
Changshu Tianyin Electromechanical
DRB22T69A2
Co., Ltd.
Sensata Technologies (Baoying) Co.,
BT62-140
Overload Ltd.
6 1pcs
protector Sensata Technologies (Baoying) Co.,
3TM205TH1
Ltd.
Shunde Ronggui Electronic Circuit
TB62-140
MeasuringEquipment Co., Ltd.
Changshu Tianyin
ZHB62-140P15
ElectromechanicalCo., Ltd.
QPS2-B15MG1 Hangzhou Star shuaier Electric
+DRB22T69A2 Appliance Co., Ltd
Starting relay and
JPQ Ⅱ -15 BK Lanxi City Yueqiang Electric
8 Overload 1pcs
+BT62-140 Co., Ltd
protector
8EA19C1-02+ Sensata Technologies (Baoying) Co.,
3TM205TH1 Ltd.
QP2-15 ZH+ Shunde Ronggui Electronic Circuit
TB62-140 MeasuringEquipment Co., Ltd.
9 Relaying cover A1 1pcs
10 Earth bolt QET.1-24C 1pcs
Anchor bolt
11 M6×30 4pcs
assembly
12 Sleeve QET-04 4pcs
13 Nut QET-27 4pcs
Hexagon
14 QD05ZB-03B 4pcs
bolt(screw)
Notes:1.All electrical parts and equipment assembly are supplied separately, not installed on the
compressor.
2.All electrical parts and equipment assembly according to “Delivery state”are all provided by our
company.
Page 8 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

10. Package、Storage and Transportation


Package type unrecyclable
Quantity 60pcs/box
Transportation By sea
Storage Max. 2 layers
Cross Weight Kg 443±24
Net Weight Kg 408±24
Volume m3 0.85
Dimension: length×width×height cm 103×89×93
Wooden supporter、upper wooden cover、foam
Main components divider、plastic sheet、cardboard cover、rain-proof
cover、wrapping
Keep the compressor in normal or vertical
Movement
position
No allowable compressor’s damage and
Trans. test requirement
performance loss.

11. Technical Items


⑴、Don’t take off the rubber plugs before using and installing compressor to prevent dust and
moisture.
⑵、Don’t turn down or incline the compressor during storage, transportation or installation and
avoid vibration and shock.
⑶、The compressor must be kept horizontally during running, the inclination angle must be less
than 5°.
⑷、A special polyester oil is charged in the R600a compressor and the charging volume has been
optimized by DONPER. Don’t pour out or add any refrigerant oil.
⑸、The interval of compressor operation must be more than 4 minutes in order to obtain a
pressure balance in the systems.
⑹、Don’t start or run in the case of vacuum or charge high voltage in the compressor. The
compressor cannot be used to vacuumize the refrigeration system.
⑺、The design of refrigeration system must be suitable to insure the oil could flow back to
compressor.
⑻、The maximum ambient temperature of the compressor operation is 43℃.When continuously
operating under the maximum ambient temperature 43℃,the condensing pressure and the peak
pressure should not exceed as showing in the following table.
Refrigerant R600a
Max. condensing pressure 0.87MPa
Peak 0.98MPa
⑼、Widen the evaporating Temp. range of the compressor should be approved by DONPER.

Page 9 of 10
S118CY1 COMPRESSOR TECHNICAL SPECIFICATION

⑽、Compressor should be stored in a dry place.


⑾、Compressor accessories (eg: starting relay, overload protector etc.) are put in the accessories
box instead of fixing on the compressor.
⑿、The stocking period must be less than 6 months after the date of production. If longer, you
have to check whether the filled gas is sufficient. Replenishment must be done if necessary.
⒀、It’s necessary to keep the compressor without rubber plug as short time as possible (max time
10 min).
⒁、R600a systems require a filter with drying agent which suitable for R600a refrigerant
⒂、The vacuum pump and the charging system must only be dedicated to R600a.
⒃、The refrigeration system should minimize the content of chlorine and moisture, and must be
free of paraffin and silicon oil.
⒄、The organic substance non-compatible with R600a cannot be used in the refrigeration system.

Page 10 of 10