Instruction Manual: LKH Centrifugal Pump
Instruction Manual: LKH Centrifugal Pump
Instruction Manual: LKH Centrifugal Pump
ESE00698-EN13 2009-12
Original manual
Table of contents
The information herein is correct at the time of issue but may be subject to change without prior notice
2. Safety .................................................................................................... 6
2.1. Important information ............................................................................. 6
2.2. Warning signs ..................................................................................... 6
2.3. Safety precautions ................................................................................ 7
3. Installation .............................................................................................. 8
3.1. Unpacking/Delivery ............................................................................... 8
3.2. Installation ......................................................................................... 9
3.3. Pre-use check - Pump without/with impeller screw ........................................... 10
4. Operation ............................................................................................... 11
4.1. Operation/Control ................................................................................. 11
4.2. Fault finding ....................................................................................... 13
4.3. Recommended cleaning ......................................................................... 14
5. Maintenance ........................................................................................... 15
5.1. General maintenance ............................................................................. 15
5.2. Dismantling of pump/shaft seals ................................................................ 17
5.3. Assembly of pump/single shaft seal ............................................................ 19
5.4. Assembly of pump/flushed shaft seal ........................................................... 21
5.5. Assembly of pump/double mechanical shaft seal ............................................. 23
5.6. Adjustment of shaft (LKH-5) ..................................................................... 25
5.7. Adjustment of shaft (LKH-10 to -90) ............................................................ 27
5.8. Cleaning Procedure ............................................................................... 29
3
Table of contents
The information herein is correct at the time of issue but may be subject to change without prior notice
7.19. LKH-90 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal ............ 66
7.20. LKH-70, LKH-75, LKH-80, LKH-85 and LKH-90 Centrifugal Pump, Shaft Seal ........... 68
4
1 EC Declaration of Conformity
Alfa Laval
Company Name
+45 79 32 22 00
Phone No.
Pump LKH
Denomination Type Year
Designation
5
2 Safety
Unsafe practices and other important information are emphasized in this manual.
Warnings are emphasized by means of special signs.
Always read the manual before using the pump!
WARNING
Indicates that special procedures must be followed to avoid severe personal injury.
CAUTION
Indicates that special procedures must be followed to avoid damage to the pump.
NOTE
Indicates important information to simplify or clarify procedures.
General warning:
Caustic agents:
Recycling information.
• Unpacking
- Packing material consists of wood, plastics, cardboard boxes and in some cases metal straps.
- Wood and cardboard boxes can be reused, recycled or used for energy recovery.
- Plastics should be recycled or burnt at a licensed waste incineration plant.
- Metal straps should be sent for material recycling.
• Maintenance
- During maintenance oil and wear parts in the machine are replaced.
- All metal parts should be sent for material recycling.
- Worn out or defective electronic parts should be sent to a licensed handler for material recycling.
- Oil and all non metal wear parts must be taken care of in agreement with local regulations.
• Scrapping
- At end of use, the equipment shall be recycled according to relevant, local regulations. Beside the equipment itself, any
hazardous residues from the process liquid must be considered and dealt with in a proper manner. When in doubt, or in the
absence of local regulations, please contact the local Alfa Laval sales company.
6
2 Safety
All warnings in the manual are summarized on this page.
Pay special attention to the instructions below so that severe personal injury and/or damage to the pump are avoided.
Installation:
Always read the technical data thoroughly. (See chapter 6 Technical data)
Always use a lifting crane when handling the pump.
Always have the pump electrically connected by authorized personnel. (See the motor instruction)
Operation:
Always read the technical data thoroughly. (See chapter 6 Technical data)
Never run the pump when partially installed or not completely assembled
Necessary precautions must be taken if leakage occurs as this can lead to hazardous situations
Never touch the pump or the pipelines when pumping hot liquids or when sterilising.
Never run the pump with both the suction side and the pressure side blocked.
Always handle lye and acid with great care.
Maintenance:
Always read the technical data thoroughly. (See chapter 6 Technical data)
Never service the pump when it is hot.
The pump and the pipelines must n ever be pressurised when the pump is serviced.
Transportation:
Transportation of the pump or the pump unit:
Never lift or elevate in any way other than described in this manual
Always drain the pump head and accessories of any liquid
Always ensure that no leakage of lubricants can occur
Always transport the pump in it’s upright position
Always ensure that the unit is securely fixed during transportation
Always use original packaging or similar during transportation
7
3 Installation
The instruction manual is part of the delivery. Study the instructions carefully.
The large pump sizes are very heavy.
Alfa Laval therefore recommends the use of a lifting crane when handling the pump.
3.1 Unpacking/Delivery
Step 2
Remove possible packing materials from the inlet and the outlet.
Avoid damaging the inlet and the outlet.
Avoid damaging the connections for flushing liquid, if supplied. Remove
packing
materials!
TD 200-120_1
Caution!
Step 3 Inspection!
Inspect the pump for visible transport damages.
TD 200-120_1
Step 5
ONLY LKH-85 and LKH-90
Do N OT use eyebolt in casing to lift the pump. The eyebolt is
only for casing removal.
8
3 Installation
Study the instructions carefully and pay special attention to the warnings! Always check the pump before operation.
- See pre-use check in section 3.3 Pre-use check - Pump without/with impeller screw.
The large pump sizes are very heavy. Alfa Laval therefore recommends the use of a lifting crane when handling the pump.
3.2 Installation
Step 1
Step 2
Ensure at least 0.5 m (1.6 ft) clearance around the pump.
Step 3
Check that the flow direction is correct.
O: Outlet
I: Inlet
Correct!
Few bends
Correct!
S tep 5
Avoid stressing the pump.
Pay special attention to:
- Vibrations.
- Thermal expansion of the tubes.
- Excessive welding.
- Overloading of the pipelines.
9
3 Installation
Study the instructions carefully and pay special attention to the warnings!
LKH-5 to -60 is without impeller screw as standard but can be supplied with one.
Check the direction of rotation of the impeller before operation.
- See the indication label on the pump.
Step 1
Never start the pump if the impeller is fitted and the pump casing
is removed.
1.
A. LKH-5: Remove screws (56), spring washers (56a), clamps
(55+55a) and pump casing (29).
B. LKH-10 to -90: Remove cap nuts (24), washers (24a) and
pump casing (29).
2. Remove impeller (27) (see also instruction in section 5.3
Assembly of pump/single shaft seal).
Stub shaft
Step 3
Fit and tighten impeller (27).
S tep 4
1. Fit pump casing (29).
2.
A. LKH-5: Fit clamps (55+55a), spring washers (56a) and
tighten screws (56)
B. LKH-10 to -90: Fit washers (24a) and tighten cap nuts (24),
according to torque values in chapter 6.3 Addendum
Correct
Never start in the wrong direction of rotation with liquid in the
pump.
1. Start and stop the motor momentarily.
2. Ensure that the direction of rotation of the motor fan is View from rear end of
clockwise as viewed from the rear end of the motor. motor
10
4 Operation
Study the instructions carefully and pay special attention to the warnings!
The pump is fitted with a warning label indicating correct throttling
4.1 Operation/Control
Step 1
CAUTION
Alfa Laval cannot be held responsible for incorrect
operation/control.
Never touch the pump or the pipelines when pumping hot liquids
or when sterilising.
Never run the pump with both the suction side and the pressure
side blocked.
TD 200-129_1
Wrong
11
4 Operation
Study the instructions carefully and pay special attention to the warnings!
The pump is fitted with a warning label indicating correct throttling
Step 5 Correct!
O
Flushed shaft seal:
1. Connect the inlet of the flushing liquid correctly. R 1/8” (BSP)
2. Regulate the water supply correctly.
3. Observe the steam data.
S tep 6 Throttling!
Control:
Reduce the capacity and the power consumption by means of:
- Throttling the pressure side of the pump.
- Reducing the impeller diameter.
- Reducing the speed of the motor.
12
4 Operation
Pay attention to possible faults.
Study the instructions carefully.
NOTE!
Study the maintenance instructions carefully before replacing worn parts. - See section 5.1 General maintenance
Cavitation:
- Damage - Low inlet pressure - Increase the inlet pressure
- Pressure reduction (sometimes to - High liquid temperature - Reduce the liquid temperature
zero)
- Increasing of the noise level - Reduce the pressure drop before the
pump
- Reduce speed
Leaking seals Incorrect rubber grade Replace with seals of a different rubber
grade
13
4 Operation
The pump is designed for cleaning in place (CIP). CIP = Cleaning In Place.
Study the instructions carefully and pay special attention to the warnings!
NaOH = Caustic Soda.
HNO3 = Nitric acid.
Step 3
Step 4
1. Avoid excessive concentration of the cleaning agent
Dose gradually!
2. Adjust the cleaning flow to the process
Sterilization of milk/viscous liquids
Increase the cleaning flow!
Always rinse well with clean water after using a cleaning agent.
NOTE
The cleaning agents must be stored/disposed of in accordance Water Cleaning agent
with current rules/directives.
14
5 Maintenance
Maintain the pump carefully. Study the instructions carefully and pay special attention to the warnings!
Always keep spare shaft seals and rubber seals in stock.
See separate motor instructions.
Check the pump for smooth operation after service.
Step 1
NOTE
All scrap must be stored/discharged in accordance with current
rules/directives.
CAUTION
Fit the electrical connections correctly if they have been removed
from the motor during service.
(see 3.3 Pre-use check - Pump without/with impeller screw)
CAUTION
Pay special attention to the warnings!
Step 4
Recommended spare parts:
Service kits (see chapter 7 Parts list and Service Kits).
Order Service Kits from Service kits list (see chapter 7 Parts list
and Service Kits).
15
5 Maintenance
Maintain the pump carefully. Study the instructions carefully and pay special attention to the warnings!
Always keep spare shaft seals and rubber seals in stock.
See separate motor instructions.
Check the pump for smooth operation after service.
Maintenance after leakage Replace at the end of the Replace when replacing the
(leakage normally starts slowly) day: Complete shaft seal shaft seal
Planned maintenance - Regular inspection for Replace when replacing the Yearly inspection is
leakage and smooth shaft seal recommended
operation - Replace complete bearing
- Keep a record of the pump if worn
- Use the statistics for - Ensure that the bearing is
planning of inspections axially locked (See motor
instructions)
Replace after leakage:
Complete shaft seal
Pre-use check
CAUTION!
Fit the electrical connections correctly if they have been removed from the motor during service. (See 3.3 Pre-use check -
Pump without/with impeller screw).
Pay special attention to warnings!
1. Start and stop the motor momentarily
2. Ensure that the pump operates smoothly.
16
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Handle scrap correctly.
: Relates to the shaft seal.
Step 1
1.
A. LKH-5: Remove screws (56), spring washers (56a), clamps
(55+55a) and pump casing (29).
B. LKH-10 to 90: Unscrew cap nuts (24) and remove washers
(24a) and pump casing (29).
S tep 2
Flushed / Double Mechanical shaft seal:
Unscrew tubes (42) using a spanner.
S tep 3
Remove screw (23) and safety guard (22).
Step 4 Counterhold
1. Remove impeller screw (36), if fitted. with a
2. Remove impeller (27). If necessary, loosen the impeller by screwdriver!
knocking gently on the impeller vanes.
3. Remove the O-ring (38) from the impeller, if fitted.
If necessary!
S tep 5
1. Pull off the O-ring (26) from back plate (25).
2. Unscrew nuts (20) and remove washers (21) and the back plate.
17
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Handle scrap correctly.
: Relates to the shaft seal.
Left hand
TD 200-462 thread!
S tep 7
Flushed shaft seal:
1. Remove screws (41) and seal housing (40).
2. Pull out lip seal (43) from the seal housing.
TD 200-390_1
Step 8
Double mechanical shaft seal:
1. Remove screws (41) and seal housing (40a).
2. Remove rotating seal rings (14) and drive ring (52) from spring
(13).
3. Remove O-rings (15) from rotating seal rings (14).
4. LKH-70 to 90: Remove cups (54) from rotating seal rings.
S tep 9
Double mechanical shaft seal:
1. Remove stationary seal ring (51) from seal housing (40a).
2. Remove O-ring (50) from stationary seal ring (51).
3. Remove O-ring (44) from seal housing (40a).
TD 200-391_1
Step 10
1. Remove the complete shaft seal from stub shaft (7).
2. Remove spring (13) and rotating seal ring (14) from the drive
ring (10).
TD 234-021_1
18
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Handle scrap correctly.
: Relates to the shaft seal.
Step 1
1. Remove spring (13).
NOTE!
Make sure that O-ring (15) has max. clearance from the sealing
surface.
S tep 2
1. Refit spring (13) on rotating seal ring (14).
2. Fit the spring and the rotating seal ring on drive ring (10).
CAUTION
Ensure that the driver on the drive ring enters the notch in the
rotating seal ring. TD 200-393_1
S tep 3
Fit the complete shaft seal on stub shaft (7).
NOTE!
Make sure that connex pin (8) on the stub shaft enters the notch in
drive ring (10).
Step 4
1. Fit O-ring (12) on stationary seal ring (11) and lubricate.
Use the tool
2. Screw the stationary seal ring into back plate (25).
supplied
CAUTION
Only tighten by hand to avoid deforming the stationary seal ring.
(Max 7Nm/5 lbf-ft)
Left hand
TD 200-462 thread!
S tep 5
1. Clean the sealing surfaces with contact cleaner before fitting
back plate (25).
2. Carefully guide the back plate onto adaptor (16).
3. Fit washers (21) and nuts (20).
TD 234-009_1
Step 6
Lubricate O-ring (26) and slide it onto back plate (25).
TD 234-026_1
19
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Handle scrap correctly.
: Relates to the shaft seal.
Step 7
1. Lubricate O-ring (38) and fit it in impeller (37), if impeller screw
is used.
2. Lubricate impeller hub with silicone grease or oil.
3. Screw the impeller onto stub shaft (7).
4. Fit impeller screw (39) and tighten, if used.
Torque - 5-60 = 20 Nm (7.4 lbf-ft)
Torque - 70-90 = 50 Nm (37 lbf-ft)
S tep 8
Fit safety guards (22) and screw (23) and tighten.
Step 9
1.
A. LKH-5: Fit pump casing (29), clamps (55+55a), spring
washers (56a) and screws (56).
B. LKH-10 to-90: Fit pump casing (29), washers (24a) and
cap nuts (24).
2. Adjust pump casing to the right position.
3.
A. LKH-5: Tighten nuts (20) for back plate (25) and tighten
screws (56).
B. LKH-10 to -90: Tighten nuts (20) for back plate (25) and
tighten cap nuts (24), according to torque values in chapter LKH-85 and LKH-90
6.3 Addendum.
20
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 2
1. Lubricate O-ring (45) and fit it in drive ring (10).
2. Fit spring (13) and rotating seal ring (14) on the drive ring.
CAUTION
Ensure that the driver on the drive ring enters the notch in the
rotating seal ring. TD 200-393_1
S tep 3
Fit complete shaft seal on stub shaft (7) so that connex pin (8) on
the stub shaft enters the notch in drive ring (10).
Step 4
1. Carefully guide back plate (25) onto adaptor (16).
2. Fit washers (21) and nuts (20).
TD 234-027_1
Step 5
Lubricate O-ring (26) and slide it onto back plate (25).
TD 234-026_1
Step 6
1. Lubricate O-ring (38) and fit it in impeller (37), if impeller screw
is used.
2. Lubricate the impeller hub with silicone grease or oil.
3. Screw impeller (27) onto stub shaft (7).
4. Fit impeller screw (36) and tighten, if used.
Torque - 5-60 20 Nm (7.4 lbf-ft)
Torque - 70-90 50 Nm (37 lbf-ft)
21
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 7
1. Screw tubes (42) into seal housing (40).
2. Tighten with a spanner.
TD 234-017_1
Step 8
Fit safety guard (22) and screw (23) and tighten.
Step 9
1.
A. LKH-5: Fit pump casing (29), clamps (55+55a), spring
washers (56a) and screws (56).
B. LKH-10 to-90: Fit pump casing (29).
2. Tighten nuts (20) for back plate (25).
3.
A. LKH-5: Tighten nuts (20) for back plate (25) and tighten
screws (56).
B. LKH-10 to -90: Fit washers (24a) and cap nuts (24)
and tighten, according to torque values in chapter 6.3
Addendum. LKH-85 and LKH-90
22
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
NOTE
Ensure that both drive pins on the drive ring enters the notches in
rotating seal rings.
Step 3
1. Lubricate O-ring (44) and slide onto seal housing (40a).
2. Lubricate O-ring (50) and fit on stationary seal ring (51) and fit
this in the seal housing.
TD 200-447_1
S tep 4
1. Clean the sealing surfaces with contact cleaner.
2. Fit seal housing (40a) on the back plate (25) and tighten screws
(41).
S tep 5
1. To enable fitting back plate (25) with the shaft seal remove
connex pin (8) from stub shaft (7) (if fitted).
2. Carefully guide the back plate onto adaptor (16).
3. Fit washers (21) and nuts (20).
TD 234-027_1
Step 6
Lubricate O-ring (26) and slide it onto back plate (25).
TD 234-033_1
23
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 7
1. Lubricate O-ring (38) and fit it in impeller (37), if impeller screw
is used.
2. Lubricate the impeller hub with silicone grease or oil.
3. Screw impeller (27) onto stub shaft (7).
4. Fit impeller screw (36) and tighten, if used.
Torque - 5-60 20 Nm (7.4 lbf-ft)
Torque - 70-90 50 Nm (37 lbf-ft)
S tep 8
1. Screw tubes (42) into seal housing (40a).
2. Tighten with a spanner.
TD 234-017_1
Step 9
Fit safety guard (22) and screw (23) and tighten.
Step 10
1. Fit pump casing (29).
2. Tighten nuts (20) for back plate (25).
3.
A. LKH-5: Fit clamps (55+55a), spring washers (56a) and
screws (56) and tighten.
B. LKH-10 to -90: Fit washers (24a) and cap nuts (24)
and tighten, according to torque values in chapter 6.3
Addendum.
24
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 1
1. Loosen screws (6).
2. Pull off stub shaft (7).
See special cleaning procedure for tapped hole in stub shaft
page 29.
S tep 2 10-20 mm
1. Push stub shaft (7) onto the motor shaft. Screws (4) must fit (0.39-0.78 inch)
in keyway on the motor shaft.
2. Check that the clearance between the end of the stub shaft
and the motor flange is 10-20 mm (0.39 - 0.78 inch).
S tep 3
1. Tighten screws (4) lightly and evenly.
2. Ensure that stub shaft (7) can be moved on the motor shaft.
S tep 4
1. F or double mechanical shaft seal: Fit drive ring (52) on stub
shaft (7).
2. Fit back plate (25), washers (21) and nuts (20) and tighten.
25
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 6
Tighten screws (4) evenly to 18 Nm (13 lbf-ft).
26
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 1
1. Loosen screws (6).
2. Pull off stub shaft (7) together with compression rings (5a,5b).
See special cleaning procedure for tapped hole in stub shaft
page 29.
S tep 2 10-20 mm
1. Push stub shaft (7) together with compression rings (5a, 5b) (0.39-0.78 inch)
onto the motor shaft.
2. Check that the clearance between the end of the stub shaft
and the motor flange is 10-20 mm (0.39 - 0.78 inch).
Step 3
1. Tighten screws (6) lightly and evenly.
2. Ensure that stub shaft (7) can be moved on the motor shaft.
S tep 4
1. F or double mechanical shaft seal:
Fit drive ring (52) on stub shaft (7).
2. Fit back plate (25), washers (21) and nuts (20) and tighten.
27
5 Maintenance
Study the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
28
5 Maintenance
Should swab testing continue to fail, or time is of the essence, install a new (spare) Stub Shaft (7).
29
6 Technical data
It is important to observe the technical data during installation, operation and maintenance.
Inform the personnel about the technical data.
Data
Materials
Shaft seal
Motor
Foot-flanged motor acc. to IEC metric standard 2 poles = 3000/3600 rpm. at 50/60 Hz IP55 (drain hole with labyrinth
plug), insulation class F
Motor sizes (kW), 50 Hz 0.75 - 1.1 - 1.5 - 2.2 - 3 - 4 - 5.5 - 7.5 - 11 - 15 -18.5 - 22 - 30 - 37 - 45 -
55 - 75 - 90 - 110 kW
Motor sizes (kW), 60 Hz 0.9 - 1.3 - 1.75 - 2.5 - 3.5 - 4.6 - 6.4 - 8.6 - 12.5 -17 - 21 - 25 - 35 - 43 -
52 - 63 - 86 - 105 - 125 kW.
Motor sizes (hp), 60 Hz 1.5 - 2.0 - 3.0 - 5.0 - 7.5 - 10.0 - 15.0 - 20.0 - 25.0 - 30.0 - 40.0 -
50.0 - 60.0 - 75.0 - 100.0 - 125.0 - 150.0 hp
30
6 Technical data
Relubrication interval 50 Hz (3000 rpm)/Relubrication interval 60 Hz (3600 rpm). (Vendor) quantity in D rive E nd/quantity in
Non D rive E nd.
The table is for 100°C internal bearing temperature.an increase in temperature of 15°C (ambient or internal in bearings), will
reduce the greasing interval and bearing lifetime by 50%. Lubrication interval for vertically mounted pumps is half the value
stated in the table.
31
6 Technical data
6.3 Addendum
Section 1
Tightening torques
Below table specifies the tightening torques for the screws, bolts and nuts in this pump.
Always use below torques if no other values are stated. This can be a matter of personal safety.
Size Tightening torgue
Nm lbf-ft
M8 20 14.8
M10 40 29.5
M12 67 49.0
M14 110 81.0
Section 2
Noise
Pump Type Sound pressure level (dBA)
LKH-5 60
LKH-10 69
LKH-15 72
LKH-20 70
LKH-25 74
LKH-35 71
LKH-40 75
LKH-45 70
LKH-50 75
LKH-60 77
LKH-70 88
LKH-75 79
LKH-85 86
LKH-90 75
The noise measurements are carried out with original motor and shroud, approximately at the Best Efficiency Point (BEP) with
water at ambient temperature and at 50Hz.
Very often the noise level generated by the flow through the process system (eg. valves, pipes, tanks etc.) is much higher than
what is generated by the pump itself. Therefore it is important to consider the noise level from the total system and take the
necessary percussions with regards to personal safety if required.
32
7 Parts list and Service Kits
The drawing shows LKH pump, sanitary version.
The items refer to the parts lists in the following sections 7.4 LKH-5 Centrifugal Pump Single, Flushed and Double Mechanical
Shaft Seal
33
7 Parts list and Service Kits
The drawing shows LKH pump, sanitary version.
The items refer to the parts lists in the following sections 7.5 LKH-10 Centrifugal Pump Single, Flushed and Double Mechanical
Shaft Seal to 7.13 LKH-60 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
7.2 LKH-10, -15, -20, -25, -35, -40, -50, -60 Sanitary Version
Impeller screw Only used for 0.75, 1.1 and 3 kW Fitting of back plate
Fitting of legs
34
7 Parts list and Service Kits
The drawing shows LKH pump, sanitary version.
The items refer to the parts lists in the following sections 7.15 LKH-70 Centrifugal Pump Single, Flushed and Double Mechanical
Shaft Seal to 7.19 LKH-90 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
35
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.4 LKH-5 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
Alternatives
36
7 Parts list and Service Kits
The drawing and the parts list include all items.
37
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.5 LKH-10 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
38
7 Parts list and Service Kits
The drawing and the parts list include all items.
Parts marked with ۫{¨Ÿaz are included in the service kits. Recommended Spare Parts: Service kits. Shaft seal: See page 56
Conversion kit, single to flushed shaft seal EPDM C/SIC 9611-92-2042 = Pos. 10+40+41+42+43+44+45
Conversion kit single to double mechanical shaft seal EPDM C/SIC 9611-92-2175 = Pos.13+ 14+15+40a+41+42+44+50+51+52
Conversion kit single to double mechanical shaft seal EPDM SIC/SIC 9611-92-2326 = Pos. 13+14+15+40a+41+42+44+50+51+52
Conversion kit, flushed to double mechanical shaft seal EPDM C/SIC 9611-92-2176 = Pos.13+ 14+40a+50+51+52
Replace to inducer (For pump with impellerscrew) please order pos. 7+57+38
Replace to inducer (For pump without impellerscrew) please order pos. 7+57+37+38
900009/3
39
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.6 LKH-15 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
40
7 Parts list and Service Kits
The drawing and the parts list include all items.
41
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.7 LKH-20 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
42
7 Parts list and Service Kits
The drawing and the parts list include all items.
Conversion kit, single to flushed shaft seal EPDM C/SIC 9611-92-2042 = Pos. 10+40+41+42+43+44+45
Conversion kit single to double mechanical shaft seal EPDM C/SIC 9611-92-2175 = Pos. 13+14+15+40a+41+42+44+50+51+52
Conversion kit single to double mechanical shaft seal EPDM SIC/SIC 9611-92-2326 = Pos.13+ 14+15+40a+41+42+44+50+51+52
Conversion kit, flushed to double mechanical shaft seal EPDM C/SIC 9611-92-2176 = Pos.13+ 14+40a+50+51+52
Replace to inducer (For pump with impeller screw) please order pos. 7+57+38
Replace to inducer (For pump without impeller screw) please order pos. 7+57+37+38.
900011/2
43
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.8 LKH-25 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
44
7 Parts list and Service Kits
The drawing and the parts list include all items.
45
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.9 LKH-35 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
46
7 Parts list and Service Kits
The drawing and the parts list include all items.
47
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.10 LKH-40 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
48
7 Parts list and Service Kits
The drawing and the parts list include all items.
Parts marked with ۫{¨Ÿaz are included in the service kits. Recommended Spare Parts: Service kits. Shaft seal: See page 56
Conversion kit, single to flushed shaft seal EPDM C/SIC 9611-92-2891 = Pos. 10+40+41+42+43+44+45
Conversion kit, single to double mechanical shaft seal EPDM C/SIC 9611-92-2175 = Pos. 13+14+15+40a+41+42+44+ 50 +51+52
Conversion kit, single to double mechanical shaft seal EPDM SIC/SIC 9611-92-2326 = Pos.13+ 14+15+40a+41+42+44+ 50 +51+52
Conversion kit, flushed to double mechanical shaft seal EPDM C/SIC 9611-92-2176 = Pos. 13+14+40a+50+51+52
Replace to inducer (for pump with impellerscrew ) please order pos. 7+57+38
Replace to inducer (for pump without impellerscrew ) please order pos. 7+57+37+38
900015/4
49
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.11 LKH-45 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
50
7 Parts list and Service Kits
The drawing and the parts list include all items.
51
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.12 LKH-50 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
52
7 Parts list and Service Kits
The drawing and the parts list include all items.
Parts marked with ۫{¨Ÿaz are included in the service kits. Recommended Spare Parts: Service kits. Shaft seal: See page 56
Conversion kit, single to flushed shaft seal EPDM C/SIC 9611-92-2891 = Pos. 10+40+41+42+43+44+45
Conversion kit, single to double mechanical shaft seal EPDM C/SIC 9611-92-2175 = Pos. 13+14+15+40a+41+42+44+50+51+52
Conversion kit, single to double mechanical shaft seal EPDM SIC/SIC 9611-92-2326 = Pos. 13+14+15+40a+41+42+44+50+51+52
Conversion kit, flushed to double mechanical shaft seal EPDM C/SIC 9611-92-2176 = Pos. 13+14+40a+50+51+52
Replace to inducer (for pump with impellerscrew) please order pos. 7+57+38
Replace to inducer (for pump without impellerscrew) please order pos. 7+57+37+38.
900017/5
53
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.13 LKH-60 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
S S
FSS
Alternatives
54
7 Parts list and Service Kits
The drawing and the parts list include all items.
55
7 Parts list and Service Kits
The drawing and the parts list include all items.
13
15
14
TD 200-372_1
12
11
43
44
45
13
15
14 TD 200-373_1
12
11
50
51
44
52
14
15
13
15
14 TD 200-374
12
11
56
7 Parts list and Service Kits
The drawing and the parts list include all items.
Parts list
Pos. Qty Denomination
Complete shaft seal
۫ Complete shaft seal
{ Complete shaft seal
Complete shaft seal
Ÿa Complete shaft seal
¨z Complete shaft seal
11 1 Stationary seal ring
12 1 O-ring
13 1 Spring
14 1 Rotating seal ring
2 Rotating seal ring, carbon
15 1 O-ring
2 O-ring
43 1 Lip seal
44 1 O-ring for seal housing
45 1 O-ring for drive ring
50 1 O-ring
51 1 Sec. stationary seal ring
52 1 Drive ring
57
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.15 LKH-70 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
58
7 Parts list and Service Kits
The drawing and the parts list include all items.
59
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.16 LKH-75 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
6a
6
70
TD 239-013
60
7 Parts list and Service Kits
The drawing and the parts list include all items.
61
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.17 LKH-80 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
62
7 Parts list and Service Kits
The drawing and the parts list include all items.
63
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.18 LKH-85 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
64
7 Parts list and Service Kits
The drawing and the parts list include all items.
Conversion kit, single to flushed shaft seal EPDM C/SIC 9611-92-2246 = Pos 40+41+42+43+44+45
Conversion kit, single to double mechanical shaft seal EPDM C/SIC 9611-92-2420 = Pos.13+14+15+ 40a+41+42+44+50+51+52+54
Conversion kit, flushed to double mechanical shaft seal EPDM C/SIC 9611-92-2421 = Pos.13+14+15+ 40a+41+50+51+52+54
900410/0
65
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.19 LKH-90 Centrifugal Pump Single, Flushed and Double Mechanical Shaft Seal
DM
SS
FSS
66
7 Parts list and Service Kits
The drawing and the parts list include all items.
67
7 Parts list and Service Kits
The drawing and the parts list include all items.
7.20 LKH-70, LKH-75, LKH-80, LKH-85 and LKH-90 Centrifugal Pump, Shaft Seal
13
15
14
12
TD 239-002_1
11
TD 239-003_2
TD 239-004_2
68
7 Parts list and Service Kits
The drawing and the parts list include all items.
Parts list
Pos. Qty Denomination
Complete shaft seal
Complete shaft seal
۫ Complete shaft seal
Complete shaft seal
{ Complete shaft seal
Complete shaft seal
11 1 Stationary seal ring, SiC.
12 1 O-ring
13 1 Spring
14 1 Rotating seal ring
2 Rotating seal ring
15 1 O-ring
2 O-ring
43 1 Lip seal
44 1 O-ring for seal housing
45 1 O-ring for drive ring
50 1 O-ring
51 1 Sec. stationary seal ring, SiC.
52 1 Drive ring
54 2 Cup