DIESEL GENERATOR SET

DE165E0

Image shown may not reflect actual package

Output Ratings

Generator Set Model - 3 Phase Prime* Standby*

400/230 V, 50 Hz 150.0 kVA 165.0 kVA


120.0 kW 132.0 kW

480V, 60 Hz 168.8 kVA 187.5 kVA


135.0 kW 150.0 kW

* Refer to ratings definitions on page 4.


Ratings at 0.8 power factor.

Technical Data
Engine Make & Model:
C7.1

Generator Model: LC3114J


Control Panel: EMCP 4.1

Base Frame Type: Heavy Duty Fabricated Steel

Circuit Breaker Type: 3 Pole MCCB


Frequency: 50 Hz 60 Hz

Engine Speed: RPM 1500 1800


Fuel Tank Capacity: litres (US gal) 349 (92.2)
Fuel Consumption, Prime: l/hr (US gal/hr) 32.4 (8.6) 37.5 (9.9)

Fuel Consumption, Standby : l/hr (US gal/hr) 35.1 (9.3) 41.1 (10.9)


DIESEL GENERATOR SET

Engine Technical Data

Physical Data Lubrication System

Manufacturer: Caterpillar Oil Filter Type: Spin-On, Full Flow


Model: Total Oil Capacity l (US gal): 16.5 (4.4)
C7.1
No. of Cylinders/Alignment: 6 / In Line Oil Pan l (US gal): 14.9 (3.9)
Cycle: 4 Stroke Oil Type: API CH4 / CI4 15W-40
Induction: Cooling Method: Water
Turbocharged Air To Air
Charge Cooled
Cooling Method: Water Performance 50 Hz 60 Hz
Governing Type: Mechanical
Engine Speed: RPM 1500 1800
Governing Class: ISO 8528 G2
Gross Engine Power: kW (hp)
Compression Ratio: 16.0:1
-Standby: 149.1 (200.0) 171.8 (230.0)
Displacement: l (cu.in) 7.0 (427.8)
-Prime: 136.0 (182.0) 155.4 (208.0)
Bore/Stroke: mm (in) 105.0 (4.1)/135.0 (5.3)
BMEP: kPa (psi)
Moment of Inertia: kg m² (lb. in²) 1.53 (5228) -Standby: 1701.0 (246.7) 1633.0 (236.8)
Engine Electrical System: -Prime: 1551.0 (225.0) 1477.0 (214.2)
-Voltage/Ground: 12/Negative Regenerative Power: kW 6.7 7.7
-Battery Charger Amps: 85
Weight: kg (lb) - Dry: 788 (1737) Fuel System
- Wet: 822 (1812) Fuel Filter Type: Replaceable Element
Recommended Fuel: Class A2 Diesel or BSEN590
Fuel Consumption: l/hr (US gal/hr)
Air System 50 Hz 60 Hz
110% 100% 75% 50%
Air Filter Type: Paper Element Load Load Load Load
Combustion Air Flow: Prime
m³/min (cfm) -Standby: 10.7 (377) 15.0 (529) 50 Hz 35.1 (9.3) 32.4 (8.6) 24.9 (6.6) 16.6 (4.4)
-Prime: 10.0 (354) 14.4 (509) 60 Hz 41.1 (10.9) 37.5 (9.9) 28.9 (7.6) 19.7 (5.2)
Max. Combustion Air Intake
Restriction: kPa (in H2O) 3.0 (12.0) 3.0 (12.0) Standby
Radiator Cooling Air Flow: 50 Hz 35.1 (9.3) 27.2 (7.2) 18.3 (4.8)
m³/min (cfm) 303.4 (10714) 239.4 (8454) 60 Hz 41.1 (10.9) 31.9 (8.4) 21.8 (5.8)
External Restriction to
(based on diesel fuel with a specific gravity of 0.85 and conforming to
Cooling Air Flow: Pa (in H2O) 125 (0.5) 125 (0.5) BS2869, Class A2)

Exhaust System 50 Hz 60 Hz
Cooling System 50 Hz 60 Hz
Silencer Type: -
Cooling System Capacity: Silencer Model & Quantity: EXSY1 (-)
l (US gal) 21.0 (5.5) 21.0 (5.5) Pressure Drop Across
Water Pump Type: Centrifugal Silencer System: kPa (in Hg) - -
Heat Rejected to Water & Silencer Noise Reduction
Lube Oil: kW (Btu/min) Level: dB - -
-Standby: 75.7 (4305) 80.1 (4555) Max. Allowable Back
-Prime: 69.1 (3930) 73.5 (4180) Pressure: kPa (in. Hg) 6.0 (1.8) 6.0 (1.8)
Heat Radiation to Room: Heat radiated from engine and alternator Exhaust Gas Flow:
kW (Btu/min) -Standby: 22.4 (1274) 23.4 (1331) m³/min (cfm) -Standby: 25.5 (902) 32.2 (1137)
-Prime: 19.9 (1132) 20.8 (1183) -Prime: 23.9 (843) 31.9 (1125)
Radiator Fan Load: kW (hp) 4.5 (6.0) 8.0 (10.7) Exhaust Gas Temperature: °C (°F)

Cooling system designed to operate in ambient conditions up to 50°C -Standby: 484 (903) 407 (765)
(122°F). Contact your local Cat dealer for power ratings at specific site -Prime: 484 (903) 407 (765)
conditions.




DIESEL GENERATOR SET

Generator Performance Data


50 Hz 60 Hz
Data Item 415/240V 400/230V 380/220V 220/127V 480/277V 380/220V 240/120V 440/254V
230/115V 220/110V 240/139V 220/110V 208/120V 220/127V
200/115V

Motor Starting
Capability* kVA 414 390 358 455 452 307 358 - 393

Short Circuit
Capacity** % 300 300 300 300 300 300 300  300

Reactances:
Per Unit

Xd 2.834 3.050 3.380 2.185 2.860 4.326 3.808 - 3.404

X'd 0.136 0.147 0.163 0.105 0.138 0.208 0.183 - 0.164

X''d 0.082 0.088 0.098 0.063 0.083 0.125 0.110 - 0.098

Reactances shown are applicable to prime ratings.


*Based on 30% voltage dip at 0.6 power factor and SHUNT excitation system.
** With optional Permanent Magnet generator.

Generator Technical Data

Physical Data Operating Data

 Overspeed: RPM 2250

Model: LC3114J Voltage Regulation: (steady state) +/- 0.5%

No. of Bearings: 1 Wave Form NEMA = TIF: 50

Insulation Class: H Wave Form IEC = THF: 2.0%

Winding Pitch - Code: 2/3 - 6 Total Harmonic Content LL/LN: 2.0%

Suppression is in line with European


Wires: 12 Radio Interference: Standard EN61000-6

Ingress Protection Rating: IP23 Radiant Heat: kW (Btu/min)

Excitation System: -50 Hz: 10.2 (580)


SHUNT

-60 Hz: 11.1 (631)


AVR Model: R250




DIESEL GENERATOR SET

Technical Data

Voltage Voltage
Prime Standby Prime Standby
50 Hz 60 Hz
kVA kW kVA kW kVA kW kVA kW

415/240V 150.0 120.0 165.0 132.0 480/277V 168.8 135.0 187.5 150.0
400/230V 150.0 120.0 165.0 132.0 220/127V 168.8 135.0 187.5 150.0
380/220V 150.0 120.0 165.0 132.0 380/220V 160.0 128.0 176.0 140.8
230/115V 150.0 120.0 165.0 132.0 240/120V 168.8 135.0 187.5 150.0
220/127V 130.0 104.0 143.0 114.4
220/110V 150.0 120.0 165.0 132.0 440/254V - - - -
200/115V 150.0 120.0 165.0 132.0 220/110V 160.0 128.0 176.0 140.8
208/120V 168.8 135.0 187.5 150.0
240/139V 168.8 135.0 187.5 150.0

Weights & Dimensions


Weights: kg (lb) Dimensions: mm (in)

Net (+ lube oil) 1610 (3549) Length 2500 (98.4)


Wet (+ lube oil & coolant) 1631 (3596) Width 1120 (44.1)
Fuel, lube oil & coolant 1927 (4247) Height 1528 (60.2)

Note: General configuration not to be used


for installation. See general dimension
drawings for detail.

Definitions General Data


Standby Rating Documents
 


   
 
 !  
 !  A full set of operation and maintenance manuals and circuit wiring
   !  "
 #$ & '
    # diagrams.
+ !  #
  
& ;$
 
 #  #
 
<   "
="" =$  #
 ! > #  
&
Quality Standards
Prime Rating The equipment meets the following standards: IEC60034-1,
Output available with varying load for an unlimited time. Average IEC60034-22, ISO3046, ISO8528, NEMA MG 1-32,
power output is 70% of the prime power rating. Typical peak NEMA MG 1-33, 2004/108/EC, 2006/42/EC, 2006/95/EC.
demand is 100% of prime rated ekW with 10% overload capability
for emergency use for a maximum of 1 hour in 12.
Overload opeation cannot exceed 25 hours per year.

.
Standard Reference Conditions
Note: Standard reference conditions 25°C (77°F) air inlet temp,
100m (328ft) A.S.L. 30% relative humidity. Fuel consumption data
at full load with diesel fuel with specific gravity of 0.85 and
conforming to BS2869: 1998, Class A2.

www.Cat-ElectricPower.com
Performance No.: ?@K< ?@'
© 2014 Caterpillar
Feature Code: $%& $%& $%& $%& All rights reserved.
Materials and specifications are subject to change without notice.
Gen. Arr. Number: 
The International System of Units (SI) is used in this publication.
Q$Z 
  
Q$ CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the
"Power Edge" trade dress, as well as corporate and product
 (0[/\@)
identity used herein, are trademarks of Caterpillar and may not be
used without permission.

You might also like