Technical Description: Technical Overview - Lube Oil System

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Technical Description

Technical overview – Lube oil system

MS61025/01E
SLU Name Sales Name
GG08V4000A1 MTU 8V4000 GS
GG08V4000A2 MTU 8V4000 GS
GG12V4000A1 MTU 12V4000 GS
GG12V4000A2 MTU 12V4000 GS
GG16V4000A1 MTU 16V4000 GS
GG16V4000A2 MTU 16V4000 GS
GG20V4000A1 MTU 20V4000 GS
GG20V4000A2 MTU 20V4000 GS

© 2016 MTU Onsite Energy GmbH, Augsburg


The original document was created in the German language.
This publication including all of its parts is protected by copyright. Each instance of use requires the prior written consent of
MTU Onsite Energy GmbH. This applies in particular to duplication, dissemination, editing, translation, microfilming, and stor-
age and/or processing in electronic systems, including databases and online services.
All of the information presented in this publication was current and up-to-date at the time of publishing. MTU Onsite Energy
GmbH reserves the right to make changes to, delete, or supplement the provided information and data as needed.
Preface
These brief instructions serve as an aid and provide information on the installation and purchasing of MTU
components for planning or design.

The brief instructions apply to the respective MTU components.


The objective of these brief instructions is to provide correct component information.
The brief instructions do not release persons responsible for the system from their responsibility for correct
design and inspection.
This document serves as an overview of the dimensions and the appearance of the specified options with the
most important technical data.
The specifications display the corresponding components so that they can be identified on the collective
drawing included here, e.g. (AWT4000_BG_1).
The specified measures and dimensions are binding. The necessary installation space and accessibility for
operation and maintenance must be guaranteed by the customer. The installation conditions must be ob-
served.

The relevant documents are defined in the specifications related to the order concerned.

Performing prescribed maintenance tasks conscientiously and on schedule positively influences operational
safety, reliability and service life. Bear in mind accessibility for operation, maintenance and repair work when
planning and installing the system.

Definition of Info box


This symbol with text box is used solely as an Info box for the reader.
It does not contain any type of references to situations where damage to material or personal
injury are possible!
It must only contain information and tips related to the product.
TIM-ID: 0000068083 - 001

MS61025/01E 2015-05 | Preface | 3


TIM-ID: 0000068083 - 001

4 | Preface | MS61025/01E 2015-05


Table of Contents
1 Lube Oil System, Lube Oil Circuit 1.2 Technical overview 7
1.1 General 6
2 Appendix A
1.1.1 Lube oil tank 6
2.1 Index 10
DCL-ID: 0000041702 - 002

MS61025/01E 2015-05 | Table of Contents | 5


1 Lube Oil System, Lube Oil Circuit
1.1 General
1.1.1 Lube oil tank
Unit consists of:
• Jacketed storage tank with two-chamber design
• Including preassembled and wired safety fittings
• Including preassembled pump group and collecting trough
• Certification according to Water Resources Act (WHG)

Material Standard steel, primed and painted


Color RAL 7032 (light gray)

Lube oil tank is suitable for 50 Hz or 60 Hz.

TIM-ID: 0000067302 - 002

6 | Lube Oil System, Lube Oil Circuit | MS61025/01E 2015-05


1.2 Technical overview

Figure 1: Lube oil tank dimensions


Dimensions
Type of Suitable Length Tank Total Total Foot Empty Maximum
tank For [mm] height height depth depth weight filling vol-
[mm] [mm] [mm] [mm] with ume
equip- [l]
ment
[kg]
A C B D E
OEL_BG_ 50 Hz 1521 1603 1863 1000 1313 770 955
1
OEL_BG_ 50 Hz 2021 1603 1863 1500 1812 1250 1950
2
OEL_BG_ 60 Hz 1521 1603 1863 1000 1313 770 955
3
OEL_BG_ 60 Hz 2021 1603 1863 1500 1812 1250 1950
TIM-ID: 0000067289 - 002

MS61025/01E 2015-05 | Lube Oil System, Lube Oil Circuit | 7


Figure 2: Lube oil tank fittings
Fittings
No. Number of Name Size
1 2 Inspection opening 400x350
2 1 Vacuum leak indicator G1/2"
3 2 Vent G2"
4 2 Return line connection G1"
5 2 Level indicator
6 2 Filling G2"
7 2 Extraction G2"
8 1 Pump group with collect-
ing trough and leak moni-
toring
9 2 Overfill protection G2"
10 2 Supply line connection G1"
11 2 Mounting bracket with
TIM-ID: 0000067289 - 002

overfill protection and


tank vehicle connector

8 | Lube Oil System, Lube Oil Circuit | MS61025/01E 2015-05


Figure 3: P&I diagram for lube oil system
1 Ball valve DN25 6 Filling 11 Mounting bracket with over-
2 Vacuum leak indicator 7 Extraction fill protection and tank vehi-
3 Ball valve DN25 8 Ball valve DN25 cle connector
4 Ball valve DN25 9 Ball valve DN25 12 Ball valve DN25 for barrel
5 Level indicator 10 Ball valve DN25 filling
13 Lube oil pump
14 Collecting trough
15 Ball valve DN25 for barrel
filling
TIM-ID: 0000067289 - 002

MS61025/01E 2015-05 | Lube Oil System, Lube Oil Circuit | 9


2 Appendix A
2.1 Index
L
Lube oil tank 6

P
Preface 3

T
Technical overview 7

DCL-ID: 0000041702 - 002