The document describes the POWERMASTER S 1001 - S 3002 UPS systems from JOVYATLAS. The systems provide power supply protection for devices like PCs, networks, and servers using online double conversion technology. They have output voltages that are sinusoidal with selection of four operating modes. The POWERMASTER S 1001 is only 1U high with an output of 1kVA and autonomy time of 4 minutes, while higher models from S 1002 to S 3002 have increased autonomy times with additional batteries. All batteries can be replaced from the front.
The document describes the POWERMASTER S 1001 - S 3002 UPS systems from JOVYATLAS. The systems provide power supply protection for devices like PCs, networks, and servers using online double conversion technology. They have output voltages that are sinusoidal with selection of four operating modes. The POWERMASTER S 1001 is only 1U high with an output of 1kVA and autonomy time of 4 minutes, while higher models from S 1002 to S 3002 have increased autonomy times with additional batteries. All batteries can be replaced from the front.
The document describes the POWERMASTER S 1001 - S 3002 UPS systems from JOVYATLAS. The systems provide power supply protection for devices like PCs, networks, and servers using online double conversion technology. They have output voltages that are sinusoidal with selection of four operating modes. The POWERMASTER S 1001 is only 1U high with an output of 1kVA and autonomy time of 4 minutes, while higher models from S 1002 to S 3002 have increased autonomy times with additional batteries. All batteries can be replaced from the front.
The document describes the POWERMASTER S 1001 - S 3002 UPS systems from JOVYATLAS. The systems provide power supply protection for devices like PCs, networks, and servers using online double conversion technology. They have output voltages that are sinusoidal with selection of four operating modes. The POWERMASTER S 1001 is only 1U high with an output of 1kVA and autonomy time of 4 minutes, while higher models from S 1002 to S 3002 have increased autonomy times with additional batteries. All batteries can be replaced from the front.
19-inch-technology. The POWERMASTER S 1001 to S 3002 UPS Systems fulfill the VFI-SS-111 pro- tection class requirements with their online double conversion technology. They are equipped with a fan control unit, connected to the output of the UPS, and with a so-called PFC (Power Factor Correction) that ensures sinusoidal power consumption. The output voltage is also sinusoidal with all POWERMASTER systems. All POWERMASTER series UPS Systems allow the selection between four different operating modes via operating panel: Online Mode, Green Mode, Free Running Mode, and Generator Mode. Green Mode can increase the efficiency of the POWERMASTER series systems up to more than 98%.
POWERMASTER S 1001 UPS Systems have a height of just 44.45 mm
(1 height unit) with an output of 1 kVA. It is only available with a standard autonomy time of 4 minutes.
The POWERMASTER S 1002 to S 3002 series offer increased autonomy times
with supplemental insertable batteries. We can offer a wide range of autonomy times that meet the individual customer’s needs.
All batteries for JOVYATLAS POWERMASTER series devices can be replaced
through the front side (Hot-Swap-System) in just a few simple steps. All POWERMASTER series systems have a battery saving charging device. The operating panel provides infor- mation on the battery status (Battery Diagnosis System).
Leaflet UPS Systems POWERMASTER PMS 1001 - 3002 E 01/2014
Product Range: UPS Systems JOVYATLAS POWERMASTER www.jovyatlas.com S 1001 - S 3002 Technical Data::
POWERMASTER PMS 1001 - 3002
Technical Data S1001 S1002 S1502 S2002 S3002 power cos phi 0,7 ind. 1000 VA/ 700 W 1000 VA/ 700 W 1500 VA/1050 W 2000 VA/ 1400 W 3000 VA/ 2100 W 230 V (115 V on request) input voltage areas: 168 - 276 V (0-100 % load) voltage 140 - 159 V (0-70 % load) 120 - 139 V (0-40 % load) input current 3,6 A 3,6 A 5,4 A 7,3 A 10 A phase single phased frequency 50 Hz / 60 Hz ± 3 Hz power factor 0,98 DC-voltage 24 V 36 V 36 V 72 V 72 V autonomy times see type table below battery type sealed, lead-acid batteries charging time <8 hours for 90%charging voltage 230 V standard (208V/220 V/240 V selectable via panel phase single phased frequency automatic adjustment by ups system output power factor 0,7 ind. distortion <3% at linear load overload behaviour 100 up to 125 % for 60 s, 125 - 150 % for 10 s crest factor 3:1 efficiency AC to AC 88 - 98 % according to mode voltage failure 0 ms / online ups switch-over behaviour overload switch-over automatic overload switch-over by ups system noise level approx. 1 m distance <40 dB(A) temperature 0° C up to 40 ° C (15°C up to 25°C recommended, battery 20° C) environment humidity 0 % up to 95 %, no condensation storing 20°C recommended operation mode online permanent operation VFI-SS-111 (adjustable) USB interface, relais card, AS/400-adapter, SNMP-adapter, manual bypass, options operation as frequency converter 50/60 Hz
Types POWERMASTER PMS 1001 - 3002
autonomy time ups-units battery racks total weight dimensions weight dimensions weight [min] [mm] [kg] PMS 1001-4 4 1 U ; D = 525 15,5 PMS 1002-0 0 - 90 2 U ; D = 425 9,7 - 17,3 Number of the battery racks and gross weight of the ups is PMS 1502-0 0 - 60 2 U ; D = 425 10,2 - 18,5 depending on the favoured autonomy time (realiseable PMS 2002-0 0 - 80 2 U ; D = 635 16,4 - 31,6 according to customers request) PMS 3002-0 0 - 40 2 U ; D = 635 17,8 - 33,0