Paw Friwa PDF
Paw Friwa PDF
Paw Friwa PDF
KG
phone: +49-5151-9856-0, fax: +49-5151-9856-98
primary circuit
The compact and completely pre-assembled station heats water in a comfortab-
le and hygienic way only when it is needed. The warm water is heated up only
at the moment it is needed – quickly, safely and cleanly – so that fresh warm
hygenical water is available at any time withour having to use a warm water
storage tank. The energy necessary for the heating of potable water comes
from a buffer storage which acn be heated via various systems: solar systems
as well as solid combustibles, traditional oil or gas boilers or other systems.
The FriWa module is suited very well for the application in connection with a
solar thermal installation and/or a low-temperature heating system thanks to
the low primary temperatures necessary.
Your advantages:
Connections:
primary circuit 3/4’’ female, potable water circuit 1’’ male, circulation line
(optional) 3/4’’ male
Flow check valve inside the return pipe of the primary circuit,
manual opener, 200 mm WC, prevent any gravity circulations; inside the
circulation line (optional) located before the pump
completely isolatable
no emptying necessary for servicing
accessories
see page
146-149
Solex
Performance characteristics of the FriWa module, for cold water entry temperature = 10 °C
warm water tap potential of 45°C transmission primary flow temperature primary return
temperature warm water at the temperature necessary temperature
set preset warm water
temperature
122
PAW GmbH & Co. KG
phone: +49-5151-9856-0, fax: +49-5151-9856-98
Integrated regulation
completely pre-assembled, preset and prewired. The tem-
perature- and flow rate-depending speed control of the
primary pump permits a quick and precise adjustment of
the preset water temperature.
The circulation pump (optional) can be operated on de-
mand (by tap impulse) time- or temperature-depending.
Additionally, it is possible to pilote a three-way reversing
valve (not included in the delivery). This way, very warm
primary return water (evolving during the operation of the
circulation pump or during phases of low tap potentials)
can be returned to the buffers torage on a higher level so
that the colder, lower part of the buffer storage remains. Hydraulic scheme FriWa
The integrated heat quantity survey permits a simple
overview over the energy needed for the preparation of
the warm potable water.
primary: Wilo RS 15 / 6-3, with circulation connection and pump Wilo Z20 / 1 640 4630 WIZ
primary: Wilo RS 15 / 6-3, without circulation pump, connection 1’’ male with tap 640 4630 WI
04/2007
Accessories are storage items; dispatch usually 2 days after order processing