Split Type Room Air Conditioner Operation Manual
Split Type Room Air Conditioner Operation Manual
Split Type Room Air Conditioner Operation Manual
OPERATION MANUAL
HSU-12CK6/B
HSU-18CK6/B
HSU-24CK6/B
HSU-12CKC/W
HSU-18CKC/W
HSU-24CKC/W
HSU-12CKA/G
HSU-18CKA/G
HSU-24CKA/G
HSU-12CKA/S
HSU-18CKA/S
HSU-24CKA/S
HSU-12CKA/B
HSU-18CKA/B
HSU-24CKA/B
Contents
PARTS AND FUNCTIONS 2
OPERATION 3
Please read this operation manual before using the air conditioner. 6
MAINTENANCE
Keep this operation manual for future reference.
CAUTIONS 7
TROUBLE SHOOTING 8
0010564364
Parts and Functions
Indoor Unit Remote controller
Inlet Air Purifying 6. TIMER OFF display
1 6
Filter Anion TIMER ON display
generator 2
Inlet
(inside) 7 7. TEMP display
grille 3 8. Additional functions display
Vertical blade Supplemented
(adjust left and 4 Operation mode QUIET SLEEP electrical
heating
HEALTH TURBO
4 Anion generator
5 12
10 1 Remove the battery cover;
2 Load the batteries as illustrated.
(inside)
6 Vertical blade 11
(adjust left and
7 Horizontal flap right air fl ow) 13
(adjust up and down air flow 2 R-03 batteries, resetting key
Don't adjust it manually)
(cylinder);
9 Power indicator (Lights up when unit starts.)
10 Timer mode indicator
3
Be sure that the loading
is in line with the" + "/"-";
(Lights up whenTimer operation is selected.)
11 Operation mode indicator Note:
4 Load the battery,then put on the cover again.
(lights up when the compressor is on.) The distance between the signal transmission head and the rece-
12 Remote signal receiver iver hole should be within 7m without any obstacle as well.
(A beeping sound is generated when a signal When electronic-started type fluorescent lamp or change- over
from remote controller isreceived.) type fluorescent lamp or wireless telephone is installed in the
13 Ambient temp display room, the receiver is apt to be disturbed in receiving the signals,
When receiving the remote control signal, display the set so the distance to the indoor unit should be shorter.
temperature and in the rest time the room temperature is Full display or unclear display during operation indicates the
displayed and this room temperature is only for reference. batteries have been used up. Please change batteries.
Actual inlet grille may vary from the one shown in the If the remote controller can't run normally during operation, please
manual according to the product purchased remove the batteries and reload several minutes later.
2
Operation
Base Operation Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
Remote controller
TURBO/QUIET
11 can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
2 sound is heard once, which means the start of this operation.
3 When power switch is turning on for the first time and
SWING emergency operation starts, the unit will run automatically in
4
the following modes: Pi
2
HEALTH SLEEP
3
TIME TIME
Room Designated Timer Fan Operation
ON OFF
temperature temperature mode speed mode
o o
Above 23 C 26 C No AUTO COOL
Cautions:
conditioner automatically adjusts the fan speed according
to room temperature.
COOL according to room temperature. When adjusting the flap by hand,turn off the unit.
In DRY mode , when room temperature becomes lower When humidity is high,condensate water might occur
DRY than temp.setting+2 o C, unit will run intermittently at LOW
speed regardless of FAN setting.
adjusted to left or at air outlet if all vertical louvers are right.
In FAN operation mode , the unit will not operate in COOL or
It is advisable not to keep horizontal flap at downward
FAN HEAT mode but only in FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
position for a long time in COOLor DRY mode ,
sleep operation is not available. otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller
controller will automatically memorize the previous set swing position.
3
Operation
Sleep Operation Note
When TIMER function is set, the sleeping function can’t be
Before going to bed,you can simply press the SLEEP set up .After the sleeping function is set up , if user resets
button and unit will operate in SLEEP mode and bring TIMER function, the sleeping function will be cancelled; the
you a sound sleep. machine will be in the state of timing-on.
TURBO/QUIET Operation
TURBO /QUIET
TURBO /QUIET
Operation Mode
When you need fast cool or fast dehumidification,you can
1. In COOL,DRY mode
choose the Turob function; when you sleep, read, you can
O
1 hours after SLEEP mode starts,temp.will become 1 C
higher than temp.setting.After another 1 hours,temp.rises
choose Quiet function
by 1OC futher.The unit will run for further 6 hours then stops
Temp. is higher than temp.setting so that room temperature
Press the TURBO /QUIET bu on, you can switch the “Turbo” and “Quiet”
won’t be too low for your sleep.
Rises 1OC
1 hr
When running in Turbo,the fan speed is the highest,
Temp.setting Unit stop
In COOL, DRY mode when running in Quiet, the fan speed is super slow
HEALTH Operation
2. In AUTO mode
The unit operaters in corresponding sleep mode
Nano-Aqua generator adopt two high voltage
adapted to the automatically selected operation mode.
pole to ionize the water molecule into
nanometer water ion,and release these ions
3. In FAN mode
to the air to kill the bacterium and refresh
It has no SLEEP function.
the air. as well as the nanometer water inon
can be easily absorbed by skin,keeping moisture
4.Set the wind speed change when sleeping anytime.
If the wind speed is high or middle before setting for the
sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.
4
Operation
Timer On/Off On-Off Operation Health airflow Operation
1.After unit starts, select your desired operation mode. 1.Press to starting
Setting the comfort work conditions.
2.Press TIMER button to change TIMER mode. Every 2.The setting of healthy airflow function
time the button is pressed, display changes as follows: Press button to select “ Healthy airflow”, the remote
Remote controller:
controller will switch as below
BLANK
0.5h 0.5h 0.5h 0.5h Healthy Healthy fixed
TIMER ON TIMER OFF TIMER ON-OFF TIMER OFF-ON airflow airflow location
upwarder downwarder
4.Confirm timer setting 3.In cooling and dry, using the air conditioner for a long
After adjust the time,press button and confirm the time under the high air humidity, condensate water may
time ON or OFF button will not flash any more. occur at the grille .
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
5
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room Do not block the air inlet Remote Controller Indoor Body
temperature or outlet
NOTE:
Detach old Air Purifying Filter The photocatalyst air purifying filter will be solarized in fixed
time. In normal family, it will be solarized every 6 months.
6
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, Use an exclusive Check proper
immediately stop the operation button and power source installation of the
contact sales shop. with a circuit drainage securely
breaker
Do not start or stop the Do not channel the air flow directly Do not try to repair or Connect the earth
operation by disconnecting at people, especially at infants or reconstruct by yourself.
the aged. cable.
the power supply cord
and so on.
earthing
PROHIBITION PROHIBITION
CAUTION
Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with
food, art work, precise equipment, when gas appliance is running at the wet hand.
breeding, or cultivation. same time.
STRICT
PROHIBITION ENFORCEMENT PROHIBITION
Do not install the unit near a fireplace Check good condition of the Do not pour water onto the unit
or other heating apparatus. installation stand for cleaning
7
Trouble shooting Cautions
Before asking for service, check the following
Do not obstruct or cover the ventilation grille of the air
first. conditoner.Do not put fingers or any other things into the
inlet/outlet and swing louver.
Phenomenon Cause or check points Do not allow children to play with the air conditioner.In no
case should children be allowed to sit on the outdoor unit.
The system When unit is stopped, it won't restart
does not restart immediately until 3 minutes have Specifications
immediately. elapsed to protect the system.
When the electric plug is pulled out The refrigerating circuit is leak-proof.
and reinserted, the protection circuit
will work for 3 minutes to protect the The machine is adaptive in following situation
air conditioner. 1.Applicable ambient temperature range:
During unit operation or at stop,
a swishing or gurgling noise may
Noise is heard be heard.At first 2-3 minutes after Maximum:D.B/W.B 32oC/23oC
unit start, this noise is more noticeable. Indoor Minimum:D.B/W.B 21oC/15oC
(This noise is generated by Cooling
refrigerant flowing in the system.) Maximum:D.B/W.B 46oC/26oC
Outdoor Minimum: D.B 18oC
During unit operation, a cracking
noise may be heard.This noise is
generated by the casing expanding
Normal or shrinking because of
Performance temperature changes.
inspection Should there be a big noise from
air flow in unit operation, air 2. If the power supply cord is damaged, it must be replaced by the
filter may be too dirty. manufacturer or its service agent or a similar qualified person.
This is because the system
Smells are circulates smells from the interior 3.If the fuse of indoor unit on PC board is broken,please change
generated. air such as the smell of furniture, it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is
paint, cigarettes.
broken,change it with the type of T.25A/250V
Mist or steam are
blown out. During COOL or DRY operation,
indoor unit may blow out mist. 4. The wiring method should be in line with the local wiring standard.
This is due to the sudden cooling
of indoor air. 5. After installation, the power plug should be easily reached.
Haier
Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China
Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010
Website: www.haier.com