CIRCUIT DESCRIPTION
This circuit turns the servomotor and changes each damper position by receiving the signals from the A/C
amplifier assy.
The air outlet damper servo switches the air outlet by rotating the motor (normal, reverse) with electrical pow-
er from the A/C amplifier.
When the AUTO switch is on, the A/C amplifier changes the mode between ”FACE”, ”BI–LEVEL” and
”FOOT” according to the temperature setting.
DTC No. Detection Item Trouble Area
Air outlet control servomotor
Air outlet damper position sensor valve does not change even
Harness or connector between air outlet control servomotor
B1443 if air conditioner amplifier operated air outlet damper control
and A/C amplifier
servo motor.
A/C amplifier
WIRING DIAGRAM
A8 A/C Amplifier
Air Outlet Control Servo Motor (A/C Control Assembly)
18
LG
A7 TPM
PT 3
P 23
A7 SGTPM
GND 2
11
O
A7 S5TPM
VZ 1
16
B
A8 AOF
MFACE 4
24
Y
A8 AOD
5
MDEF
I36322
INSPECTION PROCEDURE
1 READ VALUE ON HAND–HELD TESTER
OK:
When the target position is at the ”FACE” (–10.0%), the actual opening angle is 19.0% or less.
Result:
NG A
OK (Checking from the PROBLEM SYMPTOM TABLE) B
OK (Checking from the DTC) C
OK:
When the target position is at the ”DEF” (110.0%), the actual opening angle is 81.0% or more.
Result:
NG A
OK (Checking from the PROBLEM SYMPTOM TABLE) B
OK (Checking from the DTC) C
(e) Connect the positive (+) lead from the battery to terminal
5 and negative (–) lead to terminal 4 then check that the
FACE lever turn to ”DEF” position smoothly.
(f) Measure the resistance according to the value(s) in the
table below.
Standard:
I41193 Tester connection Condition Specified condition
A8–3 (PT) –
DEF position 0.6 to 1.1 kΩ
A8–2 (GND)
OK
Air Outlet Control Servomotor (a) Disconnect the connector from air outlet control servomo-
Connector Front View: tor and air conditioning amplifier.
(b) Measure the resistance according to the value(s) in the
A16 table below.
Standard:
Tester connection Condition Specified condition
A8–16 (AOF) –
Always Below 1 Ω
MFACE MDEF A16–4 (MFACE)
A8–24 (AOD) –
Air Conditioning Amplifier Always Below 1 Ω
A16–5 (MDEF)
Connector Wire Harness View: A8–16 (AOF) –
Always 10 kΩ or higher
Body ground
A8–24 (AOD) –
Always 10 kΩ or higher
A8 Body ground
AOF
AOD
I36370
OK