DE110E2
Output Ratings
Technical Data
Engine Make & Model:
C4.4
Fuel Consumption, Standby : l/hr (US gal/hr) 23.8 (6.3) 28.5 (7.5)
DIESEL GENERATOR SET
Exhaust System 50 Hz 60 Hz
Cooling System 50 Hz 60 Hz
Silencer Type: Industrial
Cooling System Capacity: Silencer Model & Quantity: EXSY1 (1)
l (US gal) 17.5 (4.6) 17.5 (4.6) Pressure Drop Across
Water Pump Type: Centrifugal Silencer System: kPa (in Hg) 2.10 (0.620) 3.56 (1.051)
Heat Rejected to Water & Silencer Noise Reduction
Lube Oil: kW (Btu/min) Level: dB 22 17
-Standby: 50.7 (2883) 64.0 (3640) Max. Allowable Back
-Prime: 46.1 (2622) 57.7 (3281) Pressure: kPa (in. Hg) 18.0 (5.3) 15.0 (4.4)
Heat Radiation to Room: Heat radiated from engine and alternator Exhaust Gas Flow:
kW (Btu/min) -Standby: 15.3 (870) 17.7 (1007) m/min (cfm) -Standby: 16.3 (576) 20.4 (720)
-Prime: 13.7 (779) 15.7 (893) -Prime: 15.2 (537) 18.4 (650)
Radiator Fan Load: kW (hp) 2.8 (3.8) 4.8 (6.4) Exhaust Gas Temperature: C (F)
Cooling system designed to operate in ambient conditions up to 50C -Standby: 543 (1009) 574 (1065)
(122F). Contact your local Cat dealer for power ratings at specific site -Prime: 514 (957) 517 (963)
conditions.
DIESEL GENERATOR SET
Motor Starting
Capability* kVA 256 240 220 282 280 187 219 205 242
Short Circuit
Capacity** % 300 300 300 300 300 300 300 300 300
Reactances:
Per Unit
X'd 0.120 0.129 0.143 0.107 0.121 0.194 0.162 0.175 0.145
X''d 0.072 0.077 0.086 0.064 0.073 0.116 0.097 0.105 0.087
DIESEL GENERATOR SET
Technical Data
Voltage Voltage
Prime Standby Prime Standby
50 Hz 60 Hz
kVA kW kVA kW kVA kW kVA kW
415/240V 100.0 80.0 110.0 88.0 480/277V 113.0 90.4 125.0 100.0
400/230V 100.0 80.0 110.0 88.0 220/127V 113.0 90.4 125.0 100.0
380/220V 100.0 80.0 110.0 88.0 380/220V 113.0 90.4 125.0 100.0
230/115V 100.0 80.0 110.0 88.0 240/120V 113.0 90.4 125.0 100.0
220/127V 100.0 80.0 110.0 88.0 230/115V 113.0 90.4 125.0 100.0
220/110V 100.0 80.0 110.0 88.0 440/254V 113.0 90.4 125.0 100.0
200/115V 100.0 80.0 110.0 88.0 220/110V 113.0 90.4 125.0 100.0
208/120V 113.0 90.4 125.0 100.0
240/139V 113.0 90.4 125.0 100.0
.
Standard Reference Conditions
Note: Standard reference conditions 25C (77F) air inlet temp,
100m (328ft) A.S.L. 30% relative humidity. Fuel consumption data
at full load with diesel fuel with specific gravity of 0.85 and
conforming to BS2869: 1998, Class A2.
www.Cat-ElectricPower.com
>!
#?$@>
J&;>
JK
2014 Caterpillar
Q
@ JZ
[; JZ
\; JZJ; JZJ[ All rights reserved.
Materials and specifications are subject to change without notice.
]$&$?!@JJ[J\J;JJ[J\J
The International System of Units (SI) is used in this publication.
^#@
^# CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the
"Power Edge" trade dress, as well as corporate and product
_[`jJ{
identity used herein, are trademarks of Caterpillar and may not be
used without permission.