Mech Eng JQ

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

VDE

Partly to Be Discontinued:
10A type (Made in Thailand)
Last time buy: September 30, 2016

1a/1c 5A/10A small power


relays

RoHS compliant

JQ RELAYS

FEATURES

TYPICAL APPLICATIONS

High electrical noise immunity


High switching capacity in a compact
package
High sensitivity: 200 mW (1a),
400 mW (1c)
High surge voltage: 8,000 V between
contacts and coil
UL, CSA, VDE, SEMKO approved and
TV available
Class B coil insulation type also
available.

Air conditioners
Refrigerators
Microwave ovens
Heaters

ORDERING INFORMATION
JQ

Contact arrangement
1a: 1 Form A
1 : 1 Form C
Contact capacity
Nil: Standard (5A)
P: High capacity (10A)
Coil insulation class
Nil: Class E coil insulation
B: Class B coil insulation (UL)
Nominal coil voltage (DC)
5V, 6V, 9V, 12V, 18V, 24V, 48V*
Contact material
F: AgSnO2 type
Certified by UL, CSA, VDE and SEMKO
Note: *Available only for 1 Form C type

TYPES
1) Standard type
Standard type
Nominal coil voltage
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC

1 Form A
Part No.
JQ1a-5V-F
JQ1a-6V-F
JQ1a-9V-F
JQ1a-12V-F
JQ1a-18V-F
JQ1a-24V-F

High capacity type


1 Form C
Part No.
JQ1-5V-F
JQ1-6V-F
JQ1-9V-F
JQ1-12V-F
JQ1-18V-F
JQ1-24V-F
JQ1-48V-F

1 Form A
Part No.
JQ1aP-5V-F
JQ1aP-6V-F
JQ1aP-9V-F
JQ1aP-12V-F
JQ1aP-18V-F
JQ1aP-24V-F

1 Form C
Part No.
JQ1P-5V-F
JQ1P-6V-F
JQ1P-9V-F
JQ1P-12V-F
JQ1P-18V-F
JQ1P-24V-F
JQ1P-48V-F

Standard packing: Carton 100 pcs., Case 500 pcs.

ASCTB185E 201509-T

Partly to Be Discontinued: 10A type (Made in Thailand)


Last time buy: September 30, 2016

JQ
RATING
1. Coil data
Contact
Nominal coil
arrangement
voltage
5V DC

1 Form A

1 Form C

6V DC
9V DC
12V DC
18V DC
24V DC
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC

Pick-up voltage
(at 20C 68F)
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)

Drop-out
voltage
(at 20C 68F)

5%V or more of
nominal voltage
(Initial)

5%V or more of
nominal voltage
(Initial)

Nominal operating
current
[10%] (at 20C 68F)
40.0mA

Coil resistance
[10%] (at 20C 68F)

Nominal operating
power
(at 20C 68F)

125

33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
80 mA

180
405
720
1,620
2,880
62.5

66.7mA
44.4mA
33.3mA
22.2mA
16.7mA
8.3mA

90
202.5
360
810
1,440
5,760

Max. applied voltage


180% of nominal voltage
(at 20C 68F)

200mW

130% of nominal voltage


(at 70C 158F)
[When using relays at
85C 185F, see Notes*4]
150% of nominal voltage
(at 20C 68F)

400mW

110% of nominal voltage


(at 70C 158F)
[When using relays at
85C 185F, see Notes*4]

2. Specications
Characteristics

Contact

Item
Arrangement
Contact resistance (Initial)
Contact material

Nominal switching capacity (resistive load)

Rating
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (reference value)*1
Insulation resistance (Initial)
Breakdown voltage
(Initial)

Between open contacts


Between contact and coil

Temperature rise (coil)


Electrical
characteristics
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20C 68F)
(Initial)
Release time (at nominal voltage) (at 20C 68F)
(Initial)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)

Shock resistance
Mechanical
characteristics
Expected life
Conditions

Conditions for operation, transport and storage*3


Max. operating speed

Unit weight

Specications
Standard type

High capacity type


1 Form C
1 Form A
1 Form C
Max. 100m (By voltage drop 6 V DC 1 A)
AgSnO2 type
N.O. side:
N.O. side:
5 A 125 V AC,
10 A 125 V AC,
2 A 250 V AC,
5 A 250 V AC,
5 A 125 V AC,
10 A 125 V AC,
3 A 30 V AC
5 A 30 V AC
2 A 250 V AC,
5 A 250 V AC,
N.C. side:
N.C. side:
5 A 30 V DC
5 A 30 V DC
2 A 125 V AC,
3 A 125 V AC,
1 A 250 V AC,
2 A 250 V AC,
1 A 30 V DC
1 A 30 V DC
N.O. side:
N.O. side:
625 VA, 90 W
1,250 VA, 150 W
625 VA, 150 W
1,250 V AC, 150 W
N.C. side:
N.C. side:
250 VA, 30 W
500 V AC, 30 W
250 V AC, 110 V DC (0.3A)
N.O.: 5 A, N.C.: 2 A
N.O.: 10 A, N.C.: 3 A
200 mW
400 mW
200 mW
400 mW
100 mA, 5 V DC
Min. 1,000 M (at 500 V DC) Measurement at same location as Breakdown voltage section.
1 Form A

1,000 Vrms for 1 min.

750 Vrms for 1 min.


1,000 Vrms for 1 min.
750 Vrms for 1 min.
4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 45C 113F
Max. 45C 113F
(By resistive method, nominal coil voltage
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
applied to the coil; contact carrying current:
5A, at 70C 158F)
10A, at 70C 158F)
8,000 V
Max. 20 ms (excluding contact bounce time.)
Max. 10 ms (excluding contact bounce time) (Without diode)
294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 107
Ambient temperature: 40C to +70C 40F to +158F (class E insulation),
40C to +85C 40F to +185F*4 (class B insulation)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 7 g .25 oz

* Specications will vary with foreign standards certication ratings.


Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with
20C 68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.

ASCTB185E 201509-T

Partly to Be Discontinued: 10A type (Made in Thailand)


Last time buy: September 30, 2016

JQ

3. Expected electrical life


Type
1 Form A

Standard type

N.O.
1 Form C
N.C.

1 Form A

N.O.

High capacity type


1 Form C

N.C.

Switching capacity
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
3 A 30 V DC
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC

No. of operations

3 A 125 V AC
2 A 250 V AC
1 A 30 V DC

2105
2105
105

5104
2105
2105
105
5104
2105
2105
105
2105
2105
105
5104
5104
105
5104
5104
105

REFERENCE DATA
1.-(1) Max. switching capacity (1 Form A type)

1.-(2) Max. switching capacity (1 Form C type)


100

Contact current, A

Contact current, A

100

AC resistive load (High capacity type)


10
5

100 250

10
5
3
2
AC resistive load
1 (High capacity type)
N.C. side
AC resistive load
(Standard type)
N.C. side

1 AC resistive load (Standard type)

10

AC resistive load
(High capacity type) N.O. side
AC resistive load
(Standard type) N.O. side

10

1,000

100 250

1,000

Contact voltage, V

Contact voltage, V

Standard type
2. Life curve

3.-(1) Operate & release time (1 Form A type)

3.-(2) Operate & release time (1 Form C type)

Ambient temperature: room temperature

Tested sample: JQ1a-12V-F, 25 pcs.

Tested sample: JQ1-24V-F, 25 pcs.

125V AC
resistive load
10
250V AC
resistive load

6
Operate time
4

2
Release time
1

Contact current, A

80

100

120

Max.
Max.
Min.
Min.

6
Operate time
4
Max.
Max.
Min.
Min.

2
Release time

150

Coil applied voltage, %V

Operate & release time, ms

Operate & release time, ms

Life, 104

100

80

100

120

150

Coil applied voltage, %V

ASCTB185E 201509-T

Partly to Be Discontinued: 10A type (Made in Thailand)


Last time buy: September 30, 2016

JQ
4.-(1) Coil temperature rise (1 Form A type)

4.-(2) Coil temperature rise (1 Form C type)

Contact carrying current: 3 A, 5 A


Measured portion: Inside the coil

Contact carrying current: 3 A, 5 A


Measured portion: Inside the coil
70

40

Temperature rise, C

Temperature rise, C

50

5 A at 70C
5 A at 85C

30

20
3 A at 70C

60
5 A at 70C
50
3 A at 70C
40
5 A at 85C
30
3 A at 85C
20

3 A at 85C
10

10
0

100 110 120 130 140 150 160 170 180 190

100

110

120

Coil applied voltage, %V

130

140

150

160

Coil applied voltage, %V

5.-(1) Ambient temperature characteristics


(1 Form A type)

5.-(2) Ambient temperature characteristics


(1 Form C type)

Tested sample: JQ1a-24V-F


Contact carrying current: 3 A, 5 A

Tested sample: JQ1-24V-F


Contact carrying current: 3 A, 5 A
400

300
1
2
200
3
5

Coil applied voltage, %V

Coil applied voltage, %V

400

100

300
1

200

3
5

100
6

7
0

20

30

40

50

60

70

80

90

20

30

7
40

Ambient temperature, C

50

60

70

80

90

Ambient temperature, C

1 Allowable ambient temperature against


% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 3 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 5 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 3 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 5 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
7 Pick-up voltage

High capacity type


1. Life curve

2.-(1) Operate & release time (1 Form A type)

2.-(2) Operate & release time (1 Form C type)

Ambient temperature: room temperature

Tested sample: JQ1aP-12V-F, 25 pcs.

Tested sample: JQ1P-12V-F, 25 pcs.

250V AC resistive load

Operate time

Max.
Min.
Max.
Min.

10

Release time

80

100

Contact current, A

120

150

3.-(2) Coil temperature rise (1 Form C type)


Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil

60

Operate time
4
Max.
Max.
Min.
Min.

80

100

120

150

Coil applied voltage, %V

Contact carrying current: 5 A, 10 A


Measured portion: Inside the coil

60

Release time

3.-(1) Coil temperature rise (1 Form A type)

70

Coil applied voltage, %V

70

Operate & release time, ms

125V AC resistive load


10

Operate & release time, ms

Life, 104

100

10 A at 85C
50
10 A at 70C
40
5 A at 70C

30

Temperature rise, C

Temperature rise, C

10 A at 85C
10 A at 70C
50
5 A at 70C

40

5 A at 85C
30

5 A at 85C
20

20

10

10

100

120

140

160

180

Coil applied voltage, %V

100

110

120

130

140

150

160

Coil applied voltage, %V

ASCTB185E 201509-T

Partly to Be Discontinued: 10A type (Made in Thailand)


Last time buy: September 30, 2016

JQ

4.-(1) Ambient temperature characteristics


(1 Form A type)

4.-(2) Ambient temperature characteristics


(1 Form C type)

Tested sample: JQ1aP-24V-F


Contact carrying current: 5 A, 10 A

Tested sample: JQ1P-24V-F


Contact carrying current: 5 A, 10 A
400

Coil applied voltage, %V

Coil applied voltage, %V

400

300

200

3
5

300
1

2
3

200

100

100
6

1 Allowable ambient temperature against


% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 5 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 10 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 5 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 10 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
7 Pick-up voltage

20

30

7
40

50

60

70

80

90

20

30

Ambient temperature, C

7
40

50

60

70

80

90

Ambient temperature, C

DIMENSIONS (mm inch)

The CAD data of the products with a

CAD Data

mark can be downloaded from: http://industrial.panasonic.com/ac/e/

External dimensions

CAD Data

1 Form A

1 Form A

10
.394

20
.787

Schematic (Bottom view)


1 Form C
COM

N.O.

Coil

COM

N.O.

Coil

15.6
.614

N.C.

0.4
.016
7.62
.300

4.2
.165
0.5 dia.
.020 dia.

10.16
.400
0.3
.012

7.62
.300
0.3
.012

7.62
.300
0.8
.031

1 Form C

1 Form A

10
.394

20
.787

10.16
.400

15.6
.614

4.2
.165
0.5 dia.
.020 dia.

7.62
.300

4-1.3 dia.
4-.051 dia.

7.62
.300

0.4
.016
7.62
.300

PC board pattern (Bottom view)


1FormC
10.16
.400

7.62
.300

5-1.3 dia.
5-.051 dia.

7.62
.300

2.54
.100
10.16
.400
0.3
.012

5.08
.200

2.54
.100
0.3
.012
0.3
.012

Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 5mm .197 inch:
Min. 5mm .197 inch:

7.62
.300
0.8
.031

Tolerance: 0.1 .004

General tolerance
0.2 .008
0.3 .012
0.4 .016

ASCTB185E 201509-T

Partly to Be Discontinued: 10A type (Made in Thailand)


Last time buy: September 30, 2016

JQ
SAFETY STANDARDS
Item
Standard type
(5A) 1 Form A

UL/C-UL (Recognized)
File No.
Contact rating
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC

Standard type
(5A) 1 Form C

E43028

5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC

High capacity type


(10A) 1 Form A

E43028

High capacity type


(10A) 1 Form C

E43028

10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC

CSA (Certied)
File No.
Contact rating
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC

File No.
40011435

VDE (Certied)
Contact rating
5A 250V AC (cos =0.4)

File No.

TV (Certied)
Rating

SEMKO (Certied)
File No.
Contact rating

B 11 04
5A 250V AC (cos =0.4)
13461 296 5A 30V DC (0ms)

817138

3(2)A 125V AC
2(1)A 250V AC
5A 30V DC

40011435

5A 250V AC (cos =0.4)


(N.O.)
3A 250V AC (cos =0.4)
(N.C.)

B 11 04
5A 250V AC (cos =0.4)
13461 296 5A 30V DC (0ms)

817138

3(2)A 125V AC
2(1)A 250V AC
5A 30V DC

LR26550

10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC

40011435

10A 250V AC (cos =0.4)

B 11 04
10A 250V AC (cos =0.4)
13461 296 5A 30V DC (0ms)

817138

5(3)A 250V AC
5A 30V DC

LR26550

10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC

40011435

(N.O.)
10A 250V AC (cos =0.4)
(N.C.)
3A 250V AC (cos =0.4)

B 11 04
10A 250V AC (cos =0.4)
13461 296 5A 30V DC (0ms)

817138

5(3)A 250V AC
5A 30V DC

NOTES
Note about relay installation orientation
Top

When installing with the relay terminals parallel to the ground, the contact terminals at
the bottom and the coil terminals at the top, component friction will occur after
numerous switching actions or due to vibration in the non-excitation state.
Since this may cause the relay to stop functioning when the pick-up voltage increases
even if the nominal voltage is applied, please do not install using this orientation.

Bottom

For Cautions for Use.

ASCTB185E 201509-T

You might also like