2, 000 V AC

breakdown voltage,
2 Form C and 2 A relays

RoHS compliant

TX RELAYS

FEATURES

TYPICAL APPLICATIONS

1. 2,000 V breakdown voltage between


contact and coil
2. Outstanding surge resistance.
1,500 V 10160 sec. (FCC part 68)
(open contacts)
2,500 V 210 sec. (Telcordia)
(contact and coil)
3. Nominal operating power: High
sensitivity of 140mW
4. High contact capacity: 2 A 30 V DC
5. Compact size
15.0 (L) 7.4 (W) 8.2 (H) mm
.591 (L) .291 (W) .323 (H) inch
6. High contact reliability
High contact reliability is achieved by
the use of gold-clad twin crossbar
contacts, low-gas formation materials,
mold sealing the coil section, and by
controlling organic gas in the coil.
*We also offer a range of products
with AgPd contacts suitable for use
in low level load analog circuits
(Max. 10V DC 10 mA).

1. Communications (xDSL,
Transmission)
2. Measurement
3. Security
4. Home appliances, and audio/visual
equipment
5. Medical equipment

ORDERING INFORMATION
TX 2
Contact arrangement
2: 2 Form C
Surface-mount availability
Nil: Standard PC board terminal type
SA: SA type
Operating function
Nil: Single side stable
LT: 2 coil latching
Terminal shape
Nil: Standard PC board terminal or surface-mount terminal
Nominal coil voltage (DC)*
3, 4.5, 5, 6, 9, 12, 24V
Contact material
Nil: Standard contact (Ag+Au clad)
1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable)
Packing style
Nil: Tube packing
X: Tape and reel (picked from 1/3/4/5-pin side)
Z: Tape and reel packing (picked from the 8/9/10/12-pin side)
Note: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.

ASCTB18E 201407-T

TX
TYPES
1. Standard PC board terminal
Contact
arrangement

Nominal coil
voltage

2 Form C

3 V DC
4.5 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC

Single side stable


Part No.
TX2-3V
TX2-4.5V
TX2-5V
TX2-6V
TX2-9V
TX2-12V
TX2-24V

2 coil latching
Part No.
TX2-LT-3V
TX2-LT-4.5V
TX2-LT-5V
TX2-LT-6V
TX2-LT-9V
TX2-LT-12V
TX2-LT-24V

Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.


Note: Please add -1 to the end of the part number for AgPd contacts (low level load).

2. Surface-mount terminal
1) Tube packing
Contact
arrangement

Nominal coil
voltage

2 Form C

3 V DC
4.5 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC

Single side stable


Part No.
TX2SA-3V
TX2SA-4.5V
TX2SA-5V
TX2SA-6V
TX2SA-9V
TX2SA-12V
TX2SA-24V

2 coil latching
Part No.
TX2SA-LT-3V
TX2SA-LT-4.5V
TX2SA-LT-5V
TX2SA-LT-6V
TX2SA-LT-9V
TX2SA-LT-12V
TX2SA-LT-24V

Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.


Note: Please add -1 to the end of the part number for AgPd contacts (low level load).

2) Tape and reel packing


Contact
arrangement

Nominal coil
voltage

2 Form C

3 V DC
4.5 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC

Single side stable


Part No.
TX2SA-3V-Z
TX2SA-4.5V-Z
TX2SA-5V-Z
TX2SA-6V-Z
TX2SA-9V-Z
TX2SA-12V-Z
TX2SA-24V-Z

2 coil latching
Part No.
TX2SA-LT-3V-Z
TX2SA-LT-4.5V-Z
TX2SA-LT-5V-Z
TX2SA-LT-6V-Z
TX2SA-LT-9V-Z
TX2SA-LT-12V-Z
TX2SA-LT-24V-Z

Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol -Z is not marked on the relay. X type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please add -1 to the end of the part number for AgPd contacts (low level load).

RATING
1. Coil data
1) Single side stable
Nominal coil
voltage
3

Pick-up voltage
(at 20C 68F)

Drop-out voltage
(at 20C 68F)

V DC

4.5 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC

75%V or less of
nominal voltage*
(Initial)

10%V or more of
nominal voltage*
(Initial)

Nominal operating
current
[10%] (at 20C 68F)
46.7 mA
31 mA
28.1 mA
23.3 mA
15.5 mA
11.7 mA
5.8 mA

Coil resistance
[10%] (at 20C 68F)

Nominal operating
power

Max. applied voltage


(at 20C 68F)

140 mW

150%V of
nominal voltage

64.3
145
178
257
579
1,028
4,114

2) 2 coil latching
Nominal coil
voltage
3

Set voltage
(at 20C 68F)

Reset voltage
(at 20C 68F)

V DC

4.5 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC

75%V or less of
nominal voltage*
(Initial)

75%V or less of
nominal voltage*
(Initial)

Nominal operating
current
[10%] (at 20C 68F)
Set coil
Reset coil
66.7 mA
66.7 mA
44.5 mA
40 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA

44.5 mA
40 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA

Coil resistance
[10%] (at 20C 68F)
Set coil
45

Reset coil
45

101.2
125
180
405
720
2,880

101.2
125
180
405
720
2,880

Nominal operating
power
Set coil

Reset coil

200 mW

200 mW

Max. applied voltage


(at 20C 68F

150%V of
nominal voltage

*Pulse drive (JIS C 5442-1986)

ASCTB18E 201407-T

TX
2. Specifications
Characteristics

Contact

Item
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Single side stable
Nominal operating
power
2 coil latching
Insulation resistance (Initial)
Between open contacts
Breakdown voltage
Between contact and coil
(Initial)
Between contact sets
Between open contacts
Surge breakdown
voltage (Initial)
Between contacts and coil

Rating

Electrical
characteristics

Temperature rise (at 20C 68F)


Operate time [Set time] (at 20C 68F)
Release time [Reset time] (at 20C 68F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical (Standard contact)
Shock resistance

Mechanical
characteristics

Expected life

Conditions for operation, transport and storage*2

Conditions

Max. operating speed (at rated load)


Unit weight

Specifications
2 Form C
Max. 100 m (By voltage drop 6 V DC 1A)
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load)
Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load)
220V DC
Standard contact: 2 A, AgPd contact: 1 A
10A 10mV DC
140 mW (3 to 24 V DC)
200 mW (3 to 24 V DC)
Min. 1,000M (at 500V DC) Measurement at same location as Initial breakdown voltage section.
1,000 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10160s) (FCC Part 68)
2,500 V (210s) (Telcordia)
Max. 50C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 5 mm
Min. 108 (at 180 cpm)
Min. 105 (2 A 30 V DC resistive), 5105 (1 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: 40C to +85C (up to 24 V coil) 40F to +185F (up to 24 V coil)
[40C to +70C (48 V coil) 40F to +158F (48 V coil)];
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 2 g .071 oz

Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level])
*2 Refer to AMBIENT ENVIRONMENT in GENERAL APPLICATION GUIDELINES.

REFERENCE DATA
1. Maximum switching capacity

2. Life curve

3. Mechanical life

Ratio against the rated voltage, %V

Tested sample: TX2-5V, 10 pcs.


Operating speed: 180 cpm

2.0

100
No. of operations 104

Switching current, A

3.0

DC resistive load

1.0

0.5
0.4
0.3

50
30V DC
resistive load

30
20
10

0.2

100
90
80

Pick-up voltage

70

Max.

60

Min.

50
40
30

Drop-out voltage

20

Max.
Min.

10
0

20 30

50
100
200 300
Contact voltage, V

1.0
2.0
Switching current, A

10

100
1,000
No. of operations, 104

10,000

4. Electrical life (2A 30V DC resistive load)

5. Coil temperature rise

Tested sample: TX2-5V, 6 pcs.


Operating speed: 20 cpm

Tested sample: TX2-5V, 6 pcs.


Point measured: Inside the coil
Ambient temperature: 25C 77F, 85C 185F

Change of contact resistance


100

90

90

80

Pick-up voltage

70

Max.

60

Min.

50
40

Drop-out voltage

30

Max.

20

80
70
60
50
40

Max.

30

Min.

+25C +77F
+85C +185F

60
50
40
30

2A
2A

20

0A
0A

20
Min.

10
0

70
Temperature rise, C

100

Contact resistance, m

Ratio against the rated voltage, %V

Change of pick-up and drop-out voltage

4 5 6 7 8 9
No. of operations, 104

10

10

10
0

4 5 6 7 8 9
No. of operations, 104

10

100 110

120 130 140 150


Coil applied voltage, %

ASCTB18E 201407-T

TX
6-(2). Operate and release time (without diode)

7. Ambient temperature characteristics

Tested sample: TX2-5V, 10 pcs.

Tested sample: TX2-5V, 10 pcs.

Tested sample: TX2-5V, 5 pcs.

5
Operate and release time, ms

Max.
Min.

Max.
Min.

Operate and release time, ms

5
Operate time
Release time

Rate of change, %

6-(1). Operate and release time (with diode)

Operate time
Release time

Max.
Min.

40 20
2

20

Drop-out
voltage x
x
Pick-up voltage

20 40 60 80
Ambient temperature, C
20

Max.
Min.

40

40
70

80

90
100 110 120
Coil applied voltage, %V

70

80

90
100 110 120
Coil applied voltage, %V

Tested sample: TX2-12V, 2 pcs.

Tested sample: TX2-12V, 2 pcs.

Insertion loss, dB

8-(2). High frequency characteristics


(Insertion loss)

Isolation, dB

8-(1). High frequency characteristics


(Isolation)

100

50

9. Malfunctional shock (single side stable)


Tested sample: TX2-5V, 6 pcs.

Z'
Y
Y'

Z XX'

Deenergized condition
Energized condition

Y
1000m/s 2

X
1000m/s2

Z
1000m/s2

1000m/s 2
Z'

1000m/s2
X'

1.0
0.8
0.6
0.4
1000m/s 2
Y'

0.2
10

100
Frequency, MHz

1,000

10

100
Frequency, MHz

1,000

Tested sample: TX2-12V, 6 pcs.


ON

ON

Pick-up voltage
0
5

ON

Rate of change, %

Rate of change, %

Rate of change, %

10-(2). Influence of adjacent mounting

Tested sample: TX2-12V, 6 pcs.


Rate of change, %

10-(1). Influence of adjacent mounting

OFF OFF

5
Drop-out voltage

0
5

OFF
0

2
4 6
8 10
.079 .157 .236 .315 .394
Inter-relay distance

ON

5
Pick-up voltage
0

ON

ON
OFF

5
Drop-out voltage
0

OFF
5
OFF
0

, mm inch

2
4 6
8 10
.079 .157 .236 .315 .394
Inter-relay distance

, mm inch

11. Pulse dialing test

Circuit

458

0.08
F
48V DC

0.08
F

458
Wire spring relay

4
TX
3

Ratio against the rated voltage, %V

Change of pick-up and drop-out voltage

Change of contact resistance

100

100

90

90

80

Pick-up voltage

70

Max.
Min.

60
50
40
Drop-out voltage

30
20

Max.
Min.

80
70
60
50

Max.

40
Min.

30
20
10

10
0

Contact resistance, m

Tested sample: TX2-5V, 6 pcs.


(35 mA 48 V DC wire spring relay load)

10

20
30
40
No. of operation, 104

50

10

20
30
40
No. of operations, 104

50

Note: Data of surface-mount type are the same as those of PC board terminal type.

ASCTB18E 201407-T

TX
DIMENSIONS (mm inch)

The CAD data of the products with a

CAD Data

mark can be downloaded from: http://industrial.panasonic.com/ac/e/

1. Standard PC board terminal and Self clinching terminal


Single side stable type
CAD Data
External dimensions

2 coil latching type


External dimensions

Standard PC board terminal


15.00
.591

Standard PC board terminal

7.40
.291

0.50
.020
1.15
.045

5.08
.200

3.50
.138

2.54
.100

0.65
.026

0.50
.020
1.15
.045

0.25
5.08 .010
.200

5.08
.200

2.54
.100

General tolerance: 0.3 .012

PC board pattern
(Bottom view)

Schematic (Bottom view)


Single side stable

10.16
.400

2.54
.100

+
5.08
.200

8-1.0 dia.
8-.039 dia.

PC board pattern
(Bottom view)
12.7
.500

3 4 5
2.54
.100

10 9 8
10-1.0 dia.
10-.039 dia.

(Deenergized condition)

0.25
5.08 .010
.200

3.50
.138

Schematic (Bottom view)


2 coil latching
+

5.08
.200
12

8.20
.323

General tolerance: 0.3 .012

Direction indication

Tolerance: 0.1 .004

7.40
.291

15.00
.591

0.65
.026 8.20
.323

12

3 4 5 6

10 9 8 7

Direction indication

Tolerance: 0.1 .004

(Reset condition)

2. Surface-mount terminal
CAD Data

External dimensions (General tolerance: 0.3 .012)


Single side stable type
2 coil latching type

Type

15
.591
8.2
8.4
.323 .331

SA type
0.5
.020

0.65
.026
5.08
.200

15
.591

7.4
.291

5.08
.200
9.40.5
.370.020

2.54
.100

Suggested mounting pad (Top view) (Tolerance: 0.1 .004)


Single side stable type
2 coil latching type
7.4
.291

8.2
8.4
.323 .331

0.25
.010
0.5
.020

0.65
.026
5.08
.200

2.54
.100

5.08
.200
9.40.5
.370.020

1
3.16 .039
.124
0.25
.010

5.08
.200

2.54
.100

5.08
1 .200
3.16 .039
.124
7.24
.285

2.54
.100

7.24
.285

Schematic (Top view)


Single side stable

12

10 9 8

4 5

Direction indication

(Deenergized condition)

2 coil latching

12

10 9 8 7

4 5 6

Direction indication

(Reset condition)

ASCTB18E 201407-T

TX
NOTES
1. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1) stripe

Stopper (gray)

Stopper (green)

2) Tape and reel packing (surface-mount


terminal type)
(1) Tape dimensions

2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
A

mm inch
1.5
Relay polarity bar .059
(Z type)

+0.1
0
+.004
0

dia.
dia. 2.0
.079

1.75
.069

4.0
.157

0.4
.016

C
A

Relays

11.5
.453

D
16.0 10.0 .394
.630

15.5
.610

24.0 0.3
0.2
.945 .012 9.2.008
.362

Tape coming out direction

Please chuck the


portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.

(2) Dimensions of plastic reel


mm inch

2.0
.079
13 dia.
.512 dia.

21 dia.
.827 dia.

For general cautions for use,


please refer to the Cautions for
use of Signal Relays or General
Application Guidelines.

380 dia.
14.961 dia.
80 dia.
3.150 dia.

ASCTB18E 201407-T