Axial Piston Compact Unit A10CO
Axial Piston Compact Unit A10CO
Axial Piston Compact Unit A10CO
Hydraulics
Electric Drives
and Controls
Pneumatics
Service
Automation
Mobile
Hydraulics
RE 92 730/01.98
1/8
open circuit
Size 45
Series 52
Nominal Pressure 250 bar
Peak Pressure 315 bar
Contents
Features
Ordering code
Hydraulic fluid
Technical data
2/8
A10CO | RE 92 730/01.98
Ordering code
A10C
O 45
/ 52
Hydraulic fluid
Mineral oil (without prefix)
Axial-piston pump
Compact unit in swashplate design, adjustable
Nominal pressure 250 bar, peak pressure 315 bar
A10C
Operating mode
O
Pump, open-circuit
Size
Displacement volume Vg max (cm3)
45
Control options
Pressure controller
DR
DRG
DRG
DFR
DFR
DFR
DR
DFR1
see RE 92703
cw
anti-cw
Seals
V
1"
1"
7/8"
Mounting flange
C
SAE 2-hole
Port for service lines
Pressure port B
Suction port S
Pressure port B
Suction port S
07
12
Boost pump
with integrated boost pump
H00
Valves
with integrated pressure relief valves
Filtration
Filter installed in boost circuit
without filter, mounting option only
F
D
= available
= in preparation
H00 2
RE 92 730/01.98 | A10CO
3/8
Hydraulic fluid
Comment on selecting hydraulic fluid
To select the correct hydraulic fluid it is necessary to know the
operating temperature in the tank (open circuit) in relation to
ambient temperature.
The hydraulic fluid must be selected in such a way that service
viscosity lies within the optimum range (opt) for the operating
temperature span, see shaded area in the chart.
We recommend selecting the next higher viscosity class in each
case.
Example: An ambient temperature of X C will produce an
operating temperature in the tank of 60 C. Given the optimum
service viscosity range (opt; shaded area), this will require
viscosity classes VG 46 or VG 68; class to select: VG 68.
Note: The leakage oil temperature, affected by pressure and
speed, is always higher than tank temperature. However,
temperature must not exceed 90 C anywhere in the system.
Please contact us if it is not possible to meet the above conditions
due to extreme service parameters or high ambient temperature.
Selection diagram
- 20
20
60
40
80
1000
600
400
100
80
60
40
36
opt
Viscosity (mm2 / s)
00
68
46
32
22
1
VG
VG
VG
VG
VG
200
100
1000
20
15
10
- 25
16
- 10
t min = 25 C
10
30
50
70
90
10
temperature
t ( C)
t max = + 90 C
4/8
A10CO | RE 92 730/01.98
Technical data
Service pressure range, input
Absolute pressure at port S
pabs min __________________________________________________________________ 0.8 bar
pabs max ____________________________________________________________________ 5 bar
Service pressure range, output
Pressure at port B
Nominal pressure pN _____________________________________________ 250 bar
Peak pressure pmax _______________________________________________ 315 bar
(pressures to DIN 24312)
Direction of flow
S to B.
45
Displacement volume
Vg max
cm3
45
Max. speed *
at Vg max
no max
rpm
2750
at no max
qVo max
L/min
123
at no max
Po max
kW
52
at Vg max
Tmax
Nm
181
kgm2
0.0047
0.6
kg
27.2
Fax max
1500
Fq max
1500
Application of forces
Fq
Fax
X/2 X/2
X
Calculating size
Volumetric flow
qV =
Drive torque
T =
Drive power
P =
Vg n v
[L/min]
1000
1.59 Vg p
[Nm]
100 mh
2 T n
60000
Tn
9549
qV p
600 t
[kW]
Vg
p
n
v
mh
t
RE 92 730/01.98 | A10CO
Size 45
n = 1500 rpm
n = 2600 rpm
120
100
50
qV
80
PqV max
60
40
30
40
20
PqV
20
10
0
50
100
150
200
250
60
5/8
6/8
A10CO | RE 92 730/01.98
Before finalising your design, please request certified assembly drawing.
Subject to alteration without notice.
DR
DFR
DFR1 /52 R -V U C 07 H00 2 D
DRG
12
F
102
127,5
31
L1
80
21,5
15,1
87
90
101
7/8"
G
M2
G
21
9,5
1 3/8" UNF
57
S
M1
A/C
10
41
10
32
70,5
102,5
185
244
235
175
94
B
View W
109
SW 19
50 Nm
SW 19
10 Nm
SW 6
View V
Pressure port B
52,4 +0,2
- 0,2
M10
26,2 +0,2
- 0,2
Model 12
S
25
RE 92 730/01.98 | A10CO
7/8
DR
DFR
DFR1 /52 L -V U C 07 H00 2 D
DRG
12
F
141,5
109
102,5
31
L1
21,5
15,1
101,5
7/8"
G
M2
21
9,5
M1
S
A/C
1 3/8" UNF
57
99,2
185
View W
175
94
SW19
10Nm
80
SW19
50Nm
SW 6
157
164
S
70,5
View V
Model 07
M33x2
M48x2
1 3/8" UNF-2B
Model 12
SAE 1" (standard pressure)
M48x2
1 3/8" UNF-2B
X
Control pressure port
M14x1,5
with pressure controller DR X port closed
G
Transmission lubrication port M18x1,5
M10x1
M1, M2 Measurement ports
M14x1,5
M18x1,5
M10x1
25
Ports
B
Pressure port
S
Suction port
A/C Filter port, feed pump
to DIN 71457-A1,2
L
Case drain port
Case drain port
L1
M10
102
26,2 +0,2
- 0,2
52,4 +0,2
- 0,2
10
8/8
A10CO | RE 92 730/01.98
Circuit diagram
Type A10CO 45 DFR /52 X- V U C XX H00 2D
F
X
LS
1 bar
A
must be set 10% higher
than DR-control
C
M2
S
not supplied with unit
100 m
L, L1
M1
Ports
B
S
A/C
L, L1
Pressure port
Suction port
Filter port, feed pump
Case drain ports
X
Control pressure port
with pressure controller DR X port closed
G
Transmission lubrication port
M1, M2 Measurement ports
Bosch Rexroth AG
Mobile Hydraulics
Product Segment Axial Piston Units
Horb Plant
An den Kelterwiesen 14
72160 Horb, Germany
Telephone +49 (0) 74 51 92-0
Facsimile +49 (0) 74 51 82 21
[email protected]
www.boschrexroth.com/brm