Microlife FR1DZ1
Microlife FR1DZ1
Microlife FR1DZ1
Non-contact Infrared Forehead Thermometer Dear customer, We thank you for having purchased Microlife FR1DZ1, the thermometer that takes a fast, precise body temperature reading from a distance. Microlife FR1DZ1 is a high quality product incorporating the latest technology and tested in accordance with international standards. With its unique technology, the Microlife FR1DZ1 can provide a stable, heat-interference-free reading with each measurement. The instrument performs a self-test every time it is switched on to always guarantee the specified accuracy of measurement. The Microlife FR1DZ1 allows a simple and quick measurement of body temperature. Please keep in mind that, like any skin temperature, the temperature at the forehead and temporal area might differ from the core body temperature (e.g. obtained by rectal measurement). For example a basic physiologic effect called vasoconstriction can occur in the early stages of fever, resulting in a cool skin effect, so the recorded temperature using a forehead thermometer may be suspiciously low. If the measurement result is not consistent with the patients finding or suspiciously low, repeat the measurement every 15 minutes or double check the result by another core body temperature measurement, e.g. use an infrared eardrum thermometer or a rectal pen-type thermometer. Skin temperature of babies reacts very quickly to the ambient temperature. Therefore, do not take a measurement while or after nursing, as the skin temperature may be lower than the core temperature.
Table of Contents 1. Features 2. Important Safety Instructions 3. Product Overview 4. Icons and display sequence 5. Directions of Use 6. Reference site 7. Switching between C and F 8. Recalling Readings in Memory Mode 9. Error Messages 10. Cleaning and Storage 11. Battery Replacement 12. Guarantee 13. Technical Specifications 14. Website
1. Features Non-contact Measurement within seconds The innovative infrared sensor measures temperature without even touching the subject for a safe and sanitary measurement within seconds. Human and Object Measurement Conveniently measures the temperature of a human being or an object with its sliding switch. Customized and Localized Option of Measurement Reference site selection function enables you to take measurement for readings comparable to readings taken at conventional measuring sites (rectal, oral, axillar) with a common pen-type thermometer. Tracking light Blue tracking light easily keeps you concentrated to the measured area while scanning the forehead above the eye brow with the thermometer at a distance.
1
Fever Alarm Red LCD glow and ten short beeps alert the patient that he/she may have a fever. Multiple Reading Recalls Recall the last 30 readings when you enter the Memory Mode. Auto-Display Memory The last reading is automatically displayed for 2 seconds when the unit is switched on. 2. Important Safety Instructions This instrument may be used only for the purpose described in this booklet. The manufacturer cannot be held liable for damage caused by incorrect application. Never immerse the thermometer into water or other liquids (not waterproof). For cleaning, please follow the instructions in the Cleaning and Storage section. Keep the instrument away from direct exposure to the sun and keep it in a dust-free, dry area with a temperature between -20 to 50 C (-4.0 122 F). Do not use the thermometer if there are signs of damage on the probe area or on the unit itself. If damaged, do not attempt to repair the instrument. Please contact the nearest Microlife customer service center. This thermometer consists of high-quality precision parts. Do not drop the unit! Protect it from severe impact. Do not twist the unit or the measuring probe. Warning: The use of this thermometer is not a substitute for consultation with your physician.
No. 1
Description Displays measurements and other thermometer symbols Press and release immediately to enter Memory Mode. Press and hold for 3 seconds to switch between C and F . Press to measure the temperature. Press to switch the thermometer on or off. Covers the battery for protection. Focus on the subject to measure temperature. Infrared sensor to measure the temperature. Sliding the switch down and up again activates the reference site selection. See Selecting the Reference Site. Slide the switch up to activate the body mode. Slide the switch down to activate the object mode. There is a screw on the battery cover to protect the cover.
3
3 4 5 6 7
Slide switch
screw
4. Icons and Control Display The icons on the display indicate different settings of the thermometer: Setting Description Icon The thermometer will take or has taken a Body mode body temperature. The thermometer will take or has taken an Object mode object temperature. The thermometer will take or has taken a Celsius display temperature in degree Centigrade. The thermometer will take or has taken a Fahrenheit display temperature in degree Fahrenheit. When this icon flashes, the body temperaOral reference site ture measured corresponds to the oral temperature. Axillary reference site When this icon flashes, the body temperature measured corresponds to the axillary temperature. Rectal reference site When this icon flashes, the body temperature measured corresponds to the rectal temperature. The thermometer displays a stored temperMemory recall ature from the memory.
In different stages of the operation sequence, the display shows different types of information. Display area Sequence Description Press the O/I button to turn on the unit. All segPower On ments are displayed for 2 seconds. Last Memory The last reading is displayed for 2 seconds with M icon, measuring Mode icon (body or object), and reference site icon(rectal, oral or axillar) The C or F icon is continuously flashing. The unit Ready is ready for measurement with measuring Mode icon (body or object), and reference site icon (rectal, oral or axillar) in Body mode. Measurement The reading is shown on the display area with measuring Mode icon (body or object), and referCompleted ence site icon(rectal, oral or axillar) in Body mode. After 2 seconds, the C or F icon flashes again. Further Measurement The unit is now ready for the next measurement.
4
5. Directions of Use Measuring Body Temperature 1.Make sure the mode switch is in the upper position to enter the Body Mode. 2.Press the O/I button. The LCD is activated and performs an all segment check. 3.The last readings are displayed on the LCD for 2 seconds.
4.The thermometer is ready for measurement when A short beep sound is heard The C/F and the reference site icon on the LCD are flashing. 5.For starting the measurement, aim the probe at the center of the forehead with any distance of no more than 5cm. If the forehead area is covered with hair, sweat or dirt, please remove them beforehand to improve the reading accuracy. 6. Then keep pressing the Start button. The blue tracking light is activated as a reference of area under detection.You can take measurement at any distance within 5 cm seeing the blue light. Steadily move the thermometer towards the temple to detect the body temperature. As the sensor scans the area, quick beep sounds will be emitted as indicator of temperature detecting process. The beep sounds will slow down to indicate that the body temperature has already been detected. 7.As soon as beeps slow down, please release the Start button to get the result. Stop aiming the probe. The display area shows the measured temperature. 8.Body temperature intelligent analysis. If the detected temperature is lower than fever level, a long beep is emitted and the result is displayed with a green backlight. If the detected temperature is equal to or higher than fever level, ten short beeps
5
will be emitted while the result is displayed with a red backlight to alert the patient of possible fever. Site option Rectal Oral Underarm Fever level 37.8C/100.04F 37.5C/99.5F 37.2C/98.96F
(Based on physician recommendation, temperatures taken at different body sites belong to varied ranges. Fever levels also comply with this logic.) Measuring Object Temperature 1.Make sure that the mode switch is in the lower position to enter the Object Mode. 2.Press the O/I button. The LCD is activated and performs an all segment check. 3.The last reading is displayed on the LCD for 2 seconds.
4.The thermometer is ready for measurement when A short beep sound is heard C/F icon on the LCD is flashing. 5.Aim the probe at the center of the object with any distance of no more than 5 cm. If there is water, dust or dirt, please wipe them beforehand to improve the reading accuracy. 6.Then keep pressing the Start button. The blue tracking light is activated and the sensor measures the temperature. 7.Release the Start button after a few seconds to get the result and a long beep will be heard. Stop aiming the probe. The display area shows the measured temperature. Note: Patients and the thermometer should stay in steady-state room conditions for at least
6