Vortex Flow-Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Inserts for Sewer Odor and Corrosion Control

M U N I C I P A L

S Y S T E M S

S ewe r D r o p S t r u c t u r e s Pumping Stations Fo rc em ain Disc harge

w w w. i p ex i n c . c o m

We build tough products for tough environments

VORTEX FLOW

A SIMPLE SOLUTION FOR ODOR AND CORROSION CONTROL

ydrogen sulfide (H2s) gas and other odorous gases are a fact of life with sanitary sewer drop structures. When these gases become airborne, they not only generate complaints from the neighborhood, but also impact air quality and cause corrosion within the sewer system. Municipalities spend millions on various forms of odor and corrosion control, yet many of these methods are only partially successful and require a considerable amount of maintenance and chemicals. A new solution for municipalities is the IPEX Vortex Flow Insert (VFI), a revolutionary technology for eliminating odorous emissions and minimizing corrosion in vertical sewer drops. With no moving parts and requiring no maintenance, VFIs have delivered significant cost savings in installations across North America. The VFIs patented spiral flow design eliminates odorous and corrosive gases in a unique way. It uses the wastewaters own flow energy to suppress the turbulence which releases noxious gases. The spiral flow creates a downdraft which traps airborne gases and forces air into the sewage flow to oxidize odorous gases. By installing a Vortex drop structure, municipalities can save thousands of dollars in monthly chemical feed, air-phase treatment and maintenance costs. In addition, land developers can save hundreds of thousands of dollars in excavation costs in areas where conventional drop structures are not allowed.

Flow is accelerated to Supercritical

Influent Line

BUILT-TO-SPEC FOR ANY SIZE


Manholes, chambers and pumping stations are built in a variety of sizes. For that reason, IPEX custom designs and custom builds every Vortex Flow Insert. The Vortex drop height can be as little as 5 feet or more than 100 feet tall. Shop drawings are prepared and submitted to the customer, and each phase of the project is tightly-controlled to ensure the project's success. IPEX VFIs are sized based on the peak flow that the unit is required to handle. The insert can be installed in a standard manhole without restricting access for maintenance.
5

100

HOW IT WORKS

1
Drop Structure

VORTEX TOP FORM


The wastewater flows into the Vortex Top Form which directs the flow around a channel of decreasing radius. At the same time, the Vortex channel slopes downward to accelerate the wastewater to a supercritical velocity.

Vortex Top Form

Vortex Top Cut

VORTEX DROP SHAFT


Once the flow is channeled into the smaller Drop Shaft, the velocity and centrifugal forces generated within the VFI cause the flow to hug the inside walls of the Vortex Drop Shaft. This spiraling flow creates a negative air core, which draws airborne gases down the Drop Shaft to the Energy Dissipation Pool. Frictional forces created within the Vortex Drop Shaft assist in dissipating the fluid energy.

Vortex Channel

Vortex Drop Shaft

ENERGY DISSIPATION POOL


The flow exit is submerged in the Energy Dissipation Pool at the bottom of the Vortex. Air and gases drawn down the air core are forced back through the wastewater and are re-entrained into the flow. This significantly increases the dissolved oxygen concentration in the wastewater, and the re-entrained odorous compounds are then quickly oxidized.

Flow Exit

Energy Dissipation Pool

WINNER OF THE APWA TECHNICAL ACHIEVEMENT AWARD


The American Public Works Association presents Technical Innovation Awards to designers of devices, processes or systems that benefit public works by serving the public and protecting the environment. Dr. Eugene Natarius, creator of the Vortex Drop Structure, received an award for his revolutionary design. Since then, units have been installed in cities across North America including municipalities in Ontario, California and Ohio.

Effluent Line

R E D U C E D E X C AVAT I O N C O S T S A N D L O N G T E R M

hile Vortex Flow Inserts leave manholes and pumping stations smelling better, they can also make a land developers job easier and less costly. Due to the odor and corrosion problems of conventional drop structures, many municipalities have banned them altogether. Until now, the only alternative available to land developers was to install sewers with a gradual grade to trunk sewers deep underground, a practice which can cause the cost of excavation to skyrocket. But by installing Vortex Drop Structures (drop structures with Vortex Flow Inserts), land developers can now comply with municipality concerns and save thousands, if not millions, in excavation costs. No wonder developers across North America are taking advantage of this revolutionary technology.

Finally, we have a lon system odor and cor cost that requires no definitely recommen

Frank A. Badinski, C.E.T., Asset Management Coordina Regional Municipality of Yo NAAPI Chair; NASTT Great Lakes St. Law

HOW VORTEX FLOW CAN SAVE MUNICIPALITIES MONEY


REDUCED CORROSION EXTENDS SEWER LIFE
Hydrogen sulfide (H2s) emissions from forcemain discharges can literally eat through a concrete drop manhole. By oxidizing dissolved H2s, a Vortex Flow Insert in a municipal sewer drop can significantly reduce concrete and metal corrosion, extending sewer life and saving the municipality money.

ELIMINATES ODOR TREATMENT COSTS


By increasing dissolved oxygen levels in wastewater and oxidizing sulfides and other odorous compounds, the use of a Vortex Flow Insert in a drop structure eliminates the need for costly chemical injection, high-maintenance biofilters and air scrubbers.

IMPROVES WASTE WATER QUALITY


Because a Vortex drop structure reduces the odorous and corrosive elements in the flow, a Vortex Flow Insert, installed upstream of a treatment plant, can actually improve wastewater quality prior to treatment, reducing treatment costs at sewage plants.

REDUCED MAINTENANCE COSTS


The use of a Vortex drop structure eliminates the corrosion of concrete and metal sewer components, dramatically reducing municipal maintenance costs of manholes and sewers.

S AV I N G S

APPLICATIONS

ng-term solution to our sanitary rrosion problems. It is a one-time o ongoing maintenance.I would nd this product.

ator, rk;

wrence and Atlantic Canada Vice-Chair.

Manholes, Chambers and Forcemains Wherever you have a drop from one pipe to another, Vortex drop structures can transform drop manholes from potential maintenance problems into effective aeration devices that control odor and corrosion.

Pumping Station Wet Wells A Vortex drop structure can minimize gas emissions from pumping station wet wells.

Steep Grade Sewers Vortex Flow can dissipate the flow energy of water running down a steep grade, reducing the flows discharge speed.

Turbine Discharges By dramatically reducing the


flow energy of water through turbine discharges, Vortex Flow helps to reduce the environmental disturbance when the flow is released into rivers and lakes.

TYPICAL VORTEX FLOW PROJECT


T Y P I CA L P RO J E C T F L OW

TYPICAL PROJECT FLOW FOR A VORTEX FLOW INSERT


S T E P 1 : D E S I G N I N F O R M AT I O N F O R M Customer provides a completed Design Information Form to IPEX which assists IPEX engineers in developing a conceptual design. STEP 2: CONCEPTUAL DESIGN IPEX designs the unit based on the Design Information Form. IPEX provides conceptual drawings for the project. IPEX provides an engineering estimate. STEP 3: DIMENSION SIGN-OFFS Once the project has been bid and IPEX has received the purchase order from an approved IPEX municipal distributor, IPEX will send Dimension Sign-Offs to the Project Engineer and Contractor to verify that all the data is correct. S T E P 4 : D E TA I L E D D E S I G N Upon receiving the completed Dimension Sign-Offs, IPEX design engineers will begin the Detailed Design process. S T E P 5 : FA B R I CAT I O N Once the Detailed Design has been completed, the fabrication of the Vortex unit will commence. S T E P 6 : S H I P M E N T & I N S TA L L AT I O N Once the fabrication process has been completed, the Vortex will be shipped to the jobsite along with a full set of detailed installation instructions.

R E C O G N I Z E D A S A N E W A N D I N N OVAT I V E P RO D U C T B Y T H E U. S . E PA The U.S. Environmental Protection Agency (U.S. EPA) is charged by Congress with protecting the nations land, air, and water resources. In the July 2006 publication, Emerging Technology for Conveyance Systems New Installations and Rehabilitation Methods (EPA Report: 832-R-06-004) the Vortex Flow Insert was recognized as a new and innovative product.

D E S I G N I N F O R M AT I O N F O R M

Complete this form and fax it back to us at (905) 403-1124.

Name Company City Phone Project Name Engineer

Title Address Province Fax Project Location (City, Prov, ) Bid Date

Dept.

Postal Code E-mail Owner Name Construction Launch Date

Drop Structure Information * See reverse for a depiction of a typical drop structure layout and use to answer questions 2 6. 1) New or Existing Drop Structure 2) Manhole Diameter 3) Ground Elevation 4) Manhole Floor Elevation 5) Influent Line Elevation 6) Effluent Line Elevation 7) Comments on any unique details NEW EXISTING _________________ ft | m _________________ ft | m _________________ ft | m _________________ ft | m _________________ ft | m _______________________ _________

Company classification: Architect/Design Firm Builder/Developer Operator/Plant Maintenance Contractor Distributor/Wholesaler Engineering Firm Government OEM - Product(s) Manufactured: ______________ Utility Other: _____________________________________ Product interests: PVC Pressure Systems PVC Sewer Systems Irrigation Systems Piping Systems for Water and Waste Water Treatment Plants Sewage Force Mains Service Pipe and Compression Fittings Trenchless Piping Systems I would like: PVC Pressure System Design PVC Sewer System Design Surge Pressures in PVC Installation Guide Longevity of PVC Hydraulics of PVC Pipe How PVC compares to other materials

______________________________________________ ___________________ Flow Information (Please provide us with the flow rate the Vortex will initially experience and also the estimated build out flow rate.) 1) Gravity, Forcemain or Wet Well 2) Todays Peak flow Dry Weather 3) Todays Average flow Dry Weather 4) Todays Peak flow Wet Weather 5) Build Out Peak flow Dry Weather 6) Build Out Avg. flow Dry Weather 7) Build Out Peak flow Wet Weather 8) Expected Sewage Velocity 9) Expected Build Out Time Frame GRAVITY FORCEMAIN WET WELL

_________________ MGD | m3/h _________________ MGD | m3/h _________________ MGD | m3/h _________________ MGD | m3/h _________________ MGD | m /h _________________ MGD | m /h _________________ FPS | m/s _________________ YEARS
3 3

10) Pump rate capacity of all pumps (if applicable) _________________ MGD | m3/h Influent Line Information 1) Influent line material 2) Influent line nominal diameter 3) Influent line outer diameter 4) Influent line inner diameter 5) Slope of influent line _________________ _________________ in | mm _________________ in | mm _________________ in | mm _________________ %

I would also like to know about other IPEX products: Plumbing and mechanical piping systems Electrical or telecommunications piping systems Irrigation piping systems PE Electrofusion systems for gas and water Industrial piping systems

VORTEX FLOW INSERT


D E S I G N I N F O R M AT I O N

GROUND ELEVATION ft m

MANHOLE DIAMETER Please complete flow information and influent line properties on reverse ft m

INFLUENT ELEVATION ft m

MANHOLE FLOOR ELEVATION ft m

EFFLUENT ELEVATION ft m

C O N C E P T U A L D R AW I N G

VORTEX FLOW

ITS A SIMPLE WAY TO ELIMINATE SEWER ODOR EMISSIONS

NO MORE COSTLY CHEMICAL INJECTION NO MORE HIGH-MAINTENANCE BIOFILTERS NO MORE AIR SCRUBBERS NO MORE MANHOLE SEALS

The Tree design is a registered trademark of Julius Smann Ltd. and is used with permission.

PRODUCTION

Fabrication of a 60 MGD Vortex unit Austin, Texas.

Hydrostatic testing of a large Vortex unit.

Shipping from fabrication plant, Mississauga, Ontario.

INSTALLATION

Offloading a Vortex Top Form.

A uniquely flanged Vortex, Vancouver, British Columbia.

Vortex with a flanged entrance, Manassas, Virginia.

Vortex Top Form to be secured to structure, Alexandria.

Strapping detail on Vortex unit, Buckeye, Arizona.

Securing Vortex Flow unit, Burlington, Kentucky.

Vortex unit being strapped and adapted to inlet pipe.

Vortex Flow operating in a pumping station wet well, Jacksonville, Florida.

Vortex Flow Insert reducing H2S concentration levels, Camden County, New Jersey.

SALES AND CUSTOMER SERVICE


Call IPEX Inc. Toll free: (866) 473-9462

w w w. i p e x i n c . c o m About the IPEX Group of Companies


As leading suppliers of thermoplastic piping systems, the IPEX Group of Companies provides our customers with some of the worlds largest and most comprehensive product lines. All IPEX products are backed by more than 50 years of experience. With state-of-the-art manufacturing facilities and distribution centers across North America, we have established a reputation for product innovation, quality, end-user focus and performance. Markets served by IPEX group products are:
Electrical systems Telecommunications and utility piping systems PVC, CPVC, PP, ABS, PEX, FR-PVDF and PE pipe and fittings

(1/4" to 48")
Industrial process piping systems Municipal pressure and gravity piping systems Plumbing and mechanical piping systems PE Electrofusion systems for gas and water Industrial, plumbing and electrical cements Irrigation systems

Vortex FlowTM is manufactured by IPEX Inc. Vortex FlowTM is a trademark of IPEX Branding Inc.

This literature is published in good faith and is believed to be reliable. However, it does not represent and/or warrant in any manner the information and suggestions contained in this brochure. Data presented is the result of laboratory tests and field experience. A policy of ongoing product improvement is maintained. This may result in modifications of features and/or specifications without notice.

BRMNVFIP090202R 2009 IPEX MN0021C

You might also like