Vortex Flow-Catalogue
Vortex Flow-Catalogue
Vortex Flow-Catalogue
M U N I C I P A L
S Y S T E M S
w w w. i p ex i n c . c o m
VORTEX FLOW
ydrogen sulfide (H2s) gas and other odorous gases are a fact of life with sanitary sewer drop structures. When these gases become airborne, they not only generate complaints from the neighborhood, but also impact air quality and cause corrosion within the sewer system. Municipalities spend millions on various forms of odor and corrosion control, yet many of these methods are only partially successful and require a considerable amount of maintenance and chemicals. A new solution for municipalities is the IPEX Vortex Flow Insert (VFI), a revolutionary technology for eliminating odorous emissions and minimizing corrosion in vertical sewer drops. With no moving parts and requiring no maintenance, VFIs have delivered significant cost savings in installations across North America. The VFIs patented spiral flow design eliminates odorous and corrosive gases in a unique way. It uses the wastewaters own flow energy to suppress the turbulence which releases noxious gases. The spiral flow creates a downdraft which traps airborne gases and forces air into the sewage flow to oxidize odorous gases. By installing a Vortex drop structure, municipalities can save thousands of dollars in monthly chemical feed, air-phase treatment and maintenance costs. In addition, land developers can save hundreds of thousands of dollars in excavation costs in areas where conventional drop structures are not allowed.
Influent Line
100
HOW IT WORKS
1
Drop Structure
Vortex Channel
Flow Exit
Effluent Line
R E D U C E D E X C AVAT I O N C O S T S A N D L O N G T E R M
hile Vortex Flow Inserts leave manholes and pumping stations smelling better, they can also make a land developers job easier and less costly. Due to the odor and corrosion problems of conventional drop structures, many municipalities have banned them altogether. Until now, the only alternative available to land developers was to install sewers with a gradual grade to trunk sewers deep underground, a practice which can cause the cost of excavation to skyrocket. But by installing Vortex Drop Structures (drop structures with Vortex Flow Inserts), land developers can now comply with municipality concerns and save thousands, if not millions, in excavation costs. No wonder developers across North America are taking advantage of this revolutionary technology.
Finally, we have a lon system odor and cor cost that requires no definitely recommen
Frank A. Badinski, C.E.T., Asset Management Coordina Regional Municipality of Yo NAAPI Chair; NASTT Great Lakes St. Law
S AV I N G S
APPLICATIONS
ng-term solution to our sanitary rrosion problems. It is a one-time o ongoing maintenance.I would nd this product.
ator, rk;
Manholes, Chambers and Forcemains Wherever you have a drop from one pipe to another, Vortex drop structures can transform drop manholes from potential maintenance problems into effective aeration devices that control odor and corrosion.
Pumping Station Wet Wells A Vortex drop structure can minimize gas emissions from pumping station wet wells.
Steep Grade Sewers Vortex Flow can dissipate the flow energy of water running down a steep grade, reducing the flows discharge speed.
R E C O G N I Z E D A S A N E W A N D I N N OVAT I V E P RO D U C T B Y T H E U. S . E PA The U.S. Environmental Protection Agency (U.S. EPA) is charged by Congress with protecting the nations land, air, and water resources. In the July 2006 publication, Emerging Technology for Conveyance Systems New Installations and Rehabilitation Methods (EPA Report: 832-R-06-004) the Vortex Flow Insert was recognized as a new and innovative product.
D E S I G N I N F O R M AT I O N F O R M
Title Address Province Fax Project Location (City, Prov, ) Bid Date
Dept.
Drop Structure Information * See reverse for a depiction of a typical drop structure layout and use to answer questions 2 6. 1) New or Existing Drop Structure 2) Manhole Diameter 3) Ground Elevation 4) Manhole Floor Elevation 5) Influent Line Elevation 6) Effluent Line Elevation 7) Comments on any unique details NEW EXISTING _________________ ft | m _________________ ft | m _________________ ft | m _________________ ft | m _________________ ft | m _______________________ _________
Company classification: Architect/Design Firm Builder/Developer Operator/Plant Maintenance Contractor Distributor/Wholesaler Engineering Firm Government OEM - Product(s) Manufactured: ______________ Utility Other: _____________________________________ Product interests: PVC Pressure Systems PVC Sewer Systems Irrigation Systems Piping Systems for Water and Waste Water Treatment Plants Sewage Force Mains Service Pipe and Compression Fittings Trenchless Piping Systems I would like: PVC Pressure System Design PVC Sewer System Design Surge Pressures in PVC Installation Guide Longevity of PVC Hydraulics of PVC Pipe How PVC compares to other materials
______________________________________________ ___________________ Flow Information (Please provide us with the flow rate the Vortex will initially experience and also the estimated build out flow rate.) 1) Gravity, Forcemain or Wet Well 2) Todays Peak flow Dry Weather 3) Todays Average flow Dry Weather 4) Todays Peak flow Wet Weather 5) Build Out Peak flow Dry Weather 6) Build Out Avg. flow Dry Weather 7) Build Out Peak flow Wet Weather 8) Expected Sewage Velocity 9) Expected Build Out Time Frame GRAVITY FORCEMAIN WET WELL
_________________ MGD | m3/h _________________ MGD | m3/h _________________ MGD | m3/h _________________ MGD | m3/h _________________ MGD | m /h _________________ MGD | m /h _________________ FPS | m/s _________________ YEARS
3 3
10) Pump rate capacity of all pumps (if applicable) _________________ MGD | m3/h Influent Line Information 1) Influent line material 2) Influent line nominal diameter 3) Influent line outer diameter 4) Influent line inner diameter 5) Slope of influent line _________________ _________________ in | mm _________________ in | mm _________________ in | mm _________________ %
I would also like to know about other IPEX products: Plumbing and mechanical piping systems Electrical or telecommunications piping systems Irrigation piping systems PE Electrofusion systems for gas and water Industrial piping systems
GROUND ELEVATION ft m
MANHOLE DIAMETER Please complete flow information and influent line properties on reverse ft m
INFLUENT ELEVATION ft m
EFFLUENT ELEVATION ft m
C O N C E P T U A L D R AW I N G
VORTEX FLOW
NO MORE COSTLY CHEMICAL INJECTION NO MORE HIGH-MAINTENANCE BIOFILTERS NO MORE AIR SCRUBBERS NO MORE MANHOLE SEALS
The Tree design is a registered trademark of Julius Smann Ltd. and is used with permission.
PRODUCTION
INSTALLATION
Vortex Flow Insert reducing H2S concentration levels, Camden County, New Jersey.
(1/4" to 48")
Industrial process piping systems Municipal pressure and gravity piping systems Plumbing and mechanical piping systems PE Electrofusion systems for gas and water Industrial, plumbing and electrical cements Irrigation systems
Vortex FlowTM is manufactured by IPEX Inc. Vortex FlowTM is a trademark of IPEX Branding Inc.
This literature is published in good faith and is believed to be reliable. However, it does not represent and/or warrant in any manner the information and suggestions contained in this brochure. Data presented is the result of laboratory tests and field experience. A policy of ongoing product improvement is maintained. This may result in modifications of features and/or specifications without notice.