Filters

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

PRICE LIST

Service Intervals Preventative Maintenance

1 September 2007
This price list replaces all previous price lists. Technical alterations reserved.

st

www.donaldson.com

Service Intervals and Service-kits..................................................................................... 4 Aftercooler Water cooled UFK-W ..................................................................................... 6 Aftercooler Air cooled UFK-L............................................................................................ 6 Cyclone Separator AG-Z, SG-Z........................................................................................ 6 Demister UFD................................................................................................................. 6 Ultra-Filter filters DF 0035 DF 1100 ...............................................................................7 Industrial filter Prefilter PE, SB ......................................................................................8 Industrail filter - Fine filter FF............................................................................................9 Industrial filter - Micro filter MF.........................................................................................9 Industrial filter Sub micro filter SMF ...............................................................................9 Industrial filter - Activated carbon filter AK.........................................................................9 Silicone-free filter PEP, SBP, FFP, MFP, SMFP.............................................................. 10 Medical vacuum filter MVAK, FFMV ............................................................................... 10 Vacuum filter VAK ......................................................................................................... 10 High-pressure micro filter HD-MF ................................................................................... 10 Membrane Compressed Air Dryer FRL - Maintenance unit SF ..........................................11 Membrane Compressed Air Dryer VarioDry SP................................................................11 Process filter P-SRF N, P-SRF, P-GS, P-BE....................................................................12 Process filter housing P-EG ............................................................................................12 Refrigeration compressed air dryer Buran SD 0010 SD 1650 .........................................13 Refrigeration compressed air dryer Buran DC 0020 DC 0085 .........................................14 Refrigeration compressed air dryer Boreas SD 1950 SD 12500......................................15 Refrigeration compressed air dryer Boreas DV 1800 - DV 14250 .16 Refrigeration compressed air dryer Bora HPD 0040 HPD 5000 ....................................17 Refrigeration compressed air dryer Buran HTD 0010 HTD 0225.....................................17 Activated carbon adsorber Ultrasorp AKC 0005 - 8750 .....................................................18 Adsorption dryers 0005 - 0100 ........................................................................................19 Ultrapac 2000 ................................................................................................................19 Ultrapure 2000 ...............................................................................................................19 Medipac 2000 ................................................................................................................19 Oilfreepac 2000 .............................................................................................................19 Heatless adsorption dryers Ultrapac HED, ALD, MSD ......................................................20 Purification system Oilfreepac OFP..................................................................................21

Ultrapure ALG 0035S 0375S.......................................................................................22 High Pressure Unit Ultradryer HLP PN 25 PN 40..........................................................23 Heat regenerated adsorption dryers Ultradryer HRE / HRS / HRG 0375 - 8750 .................24 Oil/water separation systems UFS-SP, UFS-SP N, UFA-AC ............................................25 Chillers Ultracool UC .....................................................................................................26 Condensate drains UFM-T, UFM-P ................................................................................27

Donaldson-Service-Logistics
Service Intervals and Service-kits Service Factory - The Donaldson idea is successful: from the development, to production and installation, up to full-service for the compressed air user, Donaldson has control over the service-logistics. A product is only as good as the service that is provided with it! - Correct. But the product must fulfil all requirements to ensure efficient business. Therefore Donaldson Ultrafilter products are designed to be service friendly, and the Donaldson service logistics are based on a clear and manageable maintenance concept. Service-kits and Carepacs are the main components of the service logistics for all Donaldson Ultrafilter products and systems. - Hence quality can easily be achieved!

On the following pages the service intervals are documented. Adherence to these secures the function of the components and systems as well as the quality of the compressed air, at the lowest power utility and best power efficiency. Regular and professional service is also a prerequisite for keeping guarantee claims and insurance entitlements up right.

The Donaldson Ultrafilter Service-kits, simplify the service performance and ensures efficient, economical and prompt service. For every product, product group or system Donaldson Ultrafilter offers a special Service-kit that matches the service intervals and includes the required wear parts, components and a description of the maintenance work to be performed.

The respectively required Service-kits are included and clearly classified in the following tables. Service-kits required for annual service intervals are marked with an A (a=annual). The extended Service-kits are marked as Carepacs and apart from all wear parts also contain the spare components that would be required for the revision of a system as well as the appropriate maintenance and operation manuals.

This documentation is a component of the Donaldson service logistics and an integrated part of the Donaldson service concept. Service means more to Donaldson than just customer service or service in the classical sense. With established and new developed service Donaldson supports the compressed air user in his efforts to be successful and competitive. The demand for service is always individual and tailor made to the requirements of the customer. With the new Service-kits and combined logistics Donaldson can live up to its expectations.

The Donaldson service offer comprises all performances from the planning, commissioning, installation, training of service people, maintenance and full-service, up to leak detection as well as determining and surveillance of the compressed air quality. With more than 350 service technicians the Donaldson service is present worldwide and short travelling distances guarantee prompt service. This saves time and money. The main goal of the Donaldson service is however to avoid emergency calls by means of a preventative maintenance. Hence for these many cost conscious compressed air users have signed up with Donaldson for long-term service agreements.

12 Months

3 Years

Product
Remarks Aftercooler Water cooled UFK-W UFK-W Service inspection Service-kit Drain UFZ Aftercooler Air cooled UFK-L UFK-L Service inspection Service-kit Drain UFZ Cyclone Separator AG-Z, SG-Z AG-Z SG-Z Service inspection Service-kit Drain UFZ Drain UFM-T Demister UFD UFD Service inspection Service-kit B Drain UFM-T Scope of service inspection 0035 8750
Examination according to operation manual Option Superplus and Standard Option Superplus Standard Option Superplus

0100 10500
Examination according to operation manual

X X X

0100 5000
Examination according to operation manual

X X X

0125 2250 1650 15000


Examination according to operation manual

X X X X

X X X

During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. Establish the condition of the system Optical controlling of the cyclone separator Testing and cleaning of the cooler Checking and cleaning of all condensate drain devises Installing the consumable replacement set of the drain Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

12 Months

3 Years

Product
Remarks Ultra-Filter Filters DF 0035 DF 1100 P B V M S Service inspection Service-kit A Standard, Plus Service-Kit A Superplus Drain UFM-T, UFM-P Ultra-Filter Filter A Service inspection Service-kit A Standard, Plus Service-Kit A Superplus DF 0035 DF 1100
Examination according to operation manual Examination according to operation manual

DF 0035 DF 1100

X X X X

X X

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. Filter is taken out of operation (secure no pressure!) Cleaning of the condensate collection area Exchange of the filter element Exchange of the seal of the housing Testing and servicing, respectively changing the drain If necessary confirming and giving notice of receipt to the service notification (Economizer) Sticking on of the service label Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

12 Months

3 Years

Product
Remarks Industrial filter Prefilter PE, SB PE Service inspection Service-kit A Drain UFM-P Drain UFM-T SB Service inspection Service-kit A Drain UFM-P Drain UFM-T Scope of service inspection
Standard larger than 0108 Option Superplus Standard larger than 0108 Option Superplus

0002 1920
Examination according to operation manual

X X X X

0002 1920
Examination according to operation manual

X X X X

During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. Filter is taken out of operation (secure no pressure!) Cleaning of the condensate collection area Exchange of the filter element Exchange of the seal of the housing Testing and servicing respectively changing of the drain If necessary confirming and giving notice of receipt of the service notification (Economizer) Sticking on of the service label Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

12 Months

3 Years

Product
Remarks Industrial filter - Fine filter FF FF Service inspection Service-kit Drain UFM-P Drain UFM-T Industrial filter - Micro filter MF MF Service inspection Service-kit Drain UFM-P Drain UFM-T SMF Service inspection Service-kit Drain UFM-P Drain UFM-T AK Service inspection Service-kit Scope of service inspection
Standard larger than 0108 Option Superplus Standard larger than 0108 Option Superplus Standard larger than 0108 Option Superplus

0002 1920
Examination according to operation manual

X X X X

0002 1920
Examination according to operation manual

X X X X

Industrial filter Sub micro filter SMF 0002 1920


Examination according to operation manual

X X X X

Industrial filter - Activated carbon filter AK 0002 1920


Examination according to operation manual

X X

During each inspection the Donaldson-service performs the following standard procedures: 1. Filter is taken out of operation (secure no pressure!) 2. Cleaning of the condensate collection area 3. Exchange of the filter element 4. Exchange of the seal of the housing 5. Testing and servicing, respectively changing the drain 6. If necessary confirming and giving notice of receipt to the service notification (Economizer) 7. Sticking on of the service label 8. Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

12 Months

3 Years

Product
Remarks Silicone-free filter PEP, SBP, FFP, MFP, SMFP PEP SBP FFP MFP SMFP Service inspection Service-kit A Drain UFM-P Drain UFM-T Medical vacuum filter MVAK, FFMV MVAK, FFMV Service inspection Service-kit A Vacuum filter VAK VAK Service inspection Service-kit A High-pressure micro filter HD-MF HD-MF Service inspection Service-kit Scope of service inspection 0003 0072
Examination according to operation manual Standard larger than 0108 Option Superplus

0002 1920
Examination according to operation manual

X X X X

0002 0192
Examination according to operation manual

X X

0002 1920
Examination according to operation manual

X X

X X

During each inspection the Donaldson-service performs the following standard procedures: 1. Filter is taken out of operation (secure no pressure!) 2. Cleaning of the condensate collection area 3. Exchange of the filter element 4. Exchange of the seal of the housing 5. Testing and servicing, respectively changing the drain 6. If necessary confirming and giving notice of receipt to the service notification (Economizer) 7. Sticking on of the service label 8. Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

10

12 Months

3 Years

Product
Remarks Membrane Compressed Air Dryer FRL - Maintenance unit SF SF Service inspection Filter element Drain Membrane Compressed Air Dryer VarioDry SP SP Service inspection Filter element Membrane performance test Scope of service inspection 5 32
Examination according to operation manual

0002 0150
Examination according to operation manual

X X X

X X X

During each inspection the Donaldson-service performs the following standard procedures: 1. Filter is taken out of operation (secure no pressure!) 2. Cleaning of the condensate collection area 3. Exchange of the filter element 4. Exchange of the seal of the housing 5. Testing and servicing, respectively changing the drain 6. If necessary confirming and giving notice of receipt to the service notification (Economizer) 7. Sticking on of the service label 8. Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

11

12 Months

3 Years

Product
Remarks Process filter P-SRF N, P-SRF, P-GS, P-BE P-SRF N Service inspection Filter element Gasket & washer set P-SRF Service inspection Filter element Gasket & washer set P-GS Service inspection Filter element Gasket & washer set P-BE Service inspection Filter element Gasket & washer set Process filter housing P-EG P-EG Service inspection Gasket & washer set Scope of service inspection 0006 1920
Examination according to operation manual

03/10 30/50
Examination according to operation manual

X X X

03/10 30/50
Examination according to operation manual

X X X

03/10 30/50
Examination according to operation manual

X X X

03/10 30/50
Examination according to operation manual

X X X

X X

During each inspection the Donaldson-service performs the following standard procedures: 1. Filter is taken out of operation (secure no pressure!) 2. Cleaning of the condensate collection area 3. Exchange of the filter element 4. Exchange of the seal of the housing 5. Testing and servicing, respectively changing the drain 6. Sticking on of the service label 7. Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

12

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type

Remarks Refrigeration compressed air dryer Buran SD 0010 SD 1650 SD 0010 A SD 1650 AP Service inspection Service-kit A Carepac e Carepac c
Refrigerant-compressor kit if required for breakdown elimination Examination according to operation manual

X X X* X*

* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. Recording the condition of the system 2. Visual check of the refrigeration cycle and the filters 3. Air-tight test of the refrigeration cycle under system pressure 4. Testing of the refrigeration compressor, valves and if necessary new adjusting 5. Testing and cleaning of the evaporator 6. Testing of the refrigerant, the control unit and the expansion valve 7. Testing of the refrigerant evaporation and re-setting if required 8. Checking of all electrical components, resistors and indicator lamps 9. Checking of the refrigeration compressor and the effectiveness 10. Cleaning and checking of the condensate blow-off device 11. Checking of the filter elements 12. Testing of the refrigeration compressor and final safety test of the complete compressed air dryer 13. Maintenance service of the fridge dryer: Elimination of smaller malfunctions to the equipment as far as this is possible without extremely time consuming repairs and additional material 14. Recording of the data and inspection contents in a service report

5 Years

13

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type

Remarks Refrigeration compressed air dryer Buran DC 0020 DC 0085 DC 0020 A DC 0085 A Service inspection Service-kit A Carepac e Carepac c
Refrigerant-compressor kit if required for breakdown elimination Examination according to operation manual

X X X* X*

* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. Recording the condition of the system 2. Visual check of the refrigeration cycle and the filters 3. Air-tight test of the refrigeration cycle under system pressure 4. Testing of the refrigeration compressor, valves and if necessary new adjusting 5. Testing and cleaning of the evaporator 6. Testing of the refrigerant, the control unit and the expansion valve 7. Testing of the refrigerant evaporation and re-setting if required 8. Checking of all electrical components, resistors and indicator lamps 9. Checking of the refrigeration compressor and the effectiveness 10. Cleaning and checking of the condensate blow-off device 11. Checking of the filter elements 12. Testing of the refrigeration compressor and final safety test of the complete compressed air dryer 13. Maintenance service of the fridge dryer: Elimination of smaller malfunctions to the equipment as far as this is possible without extremely time consuming repairs and additional material 14. Recording of the data and inspection contents in a service report

5 Years

14

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Refrigeration compressed air dryer Boreas SD 1950 SD 12500 SD 1950 SD 12500 Service inspection Service-kit A Carepac e Carepac c Scope of service inspection
During each inspection the Donaldson-service performs the following standard procedures: 1. Recording the condition of the system 2. Visual check of the refrigeration cycle and the filters 3. Air-tight test of the refrigeration cycle under system pressure 4. Testing of the refrigeration compressor, valves and if necessary new adjusting 5. Testing and cleaning of the evaporator 6. Testing of the refrigerant, the control unit and the expansion valve 7. Testing of the refrigerant evaporation and re-setting if required 8. Checking of all electrical components, resistors and indicator lamps 9. Checking of the refrigeration compressor and the effectiveness 10. Cleaning and checking of the condensate blow-off device 11. Checking of the filter elements 12. Testing of the refrigeration compressor and final safety test of the complete compressed air dryer 13. Maintenance service of the fridge dryer: Elimination of smaller malfunctions to the equipment as far as this is possible without extremely time consuming repairs and additional material 14. Recording of the data and inspection contents in a service report Refrigerant-compressor kit if required for breakdown elimination Examination according to operation manual

X X X

5 Years

15

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Refrigeration compressed air dryer Boreas DV 1800 DV 14250 DV 1800 DV 14250 Service inspection Service-kit A Carepac e Carepac c Scope of service inspection
During each inspection the Donaldson-service performs the following standard procedures: Refrigerant-compressor kit if required for breakdown elimination Examination according to operation manual

X X X

1. Recording the condition of the system 2. Visual check of the refrigeration cycle and the filters 3. Air-tight test of the refrigeration cycle under system pressure 4. Testing of the refrigeration compressor, valves and if necessary new adjusting 5. Testing and cleaning of the evaporator 6. Testing of the refrigerant, the control unit and the expansion valve 7. Testing of the refrigerant evaporation and re-setting if required 8. Checking of all electrical components, resistors and indicator lamps 9. Checking of the refrigeration compressor and the effectiveness 10. Cleaning and checking of the condensate blow-off device 11. Checking of the filter elements 12. Testing of the refrigeration compressor and final safety test of the complete compressed air dryer 13. Maintenance service of the fridge dryer: Elimination of smaller malfunctions to the equipment as far as this is possible without extremely time consuming repairs and additional material 14. Recording of the data and inspection contents in a service report

5 Years

16

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Refrigeration compressed air dryer Bora HPD 0040 HPD 5000 Refrigeration compressed air dryer Buran HTD 0010 HTD 0225 HPD HTD Service inspection Service-kit A Carepac e
Refrigerant-compressor kit if required for breakdown elimination *acc. to application

0040 5000 0010 0225


Examination according to operation manual

X X X* X*

Carepac c

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures:

1. Recording the condition of the system 2. Visual check of the refrigeration cycle and the filters 3. Air-tight test of the refrigeration cycle under system pressure 4. Testing of the refrigeration compressor, valves and if necessary new adjusting 5. Testing and cleaning of the evaporator 6. Testing of the refrigerant, the control unit and the expansion valve 7. Testing of the refrigerant evaporation and re-setting if required 8. Checking of all electrical components, resistors and indicator lamps 9. Checking of the refrigeration compressor and the effectiveness 10. Cleaning and checking of the condensate blow-off device 11. Checking of the filter elements 12. Testing of the refrigeration compressor and final safety test of the complete compressed air dryer 13. Maintenance service of the fridge dryer: Elimination of smaller malfunctions to the equipment as far as this is possible without extremely time consuming repairs and additional material 14. Recording of the data and inspection contents in a service report

5 Years

17

12 Months

3 Years

Product
Remarks Activated carbon adsorber Ultrasorp AKC 0005 - 8750 AKC Service inspection Carepac 0005 8750
Examination according to operation manual

X*

X X
* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. Visual controlling of the activated carbon desiccant Checking of the desiccant and exchanging it according to the service interval Leakage-test under pressure Test-run under pressure New operation start-up of the activated carbon desiccant Checking of the compressed air quality Recording of the data and inspection contents in a ser vice report

18

5 Years

Type

24 Months

3 Months

6 Months

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Adsorption dryers 0005 - 0100 Ultrapac 2000 Service inspection Service-kit A Carepac Ultrapure 2000
Medipac 2000

0005 0100
Examination according to operation manual

X X X*

0005 0100
Examination according to operation manual

Service inspection Service-kit A Carepac 1 Carepac 2 Oilfreepac 2000 Service inspection Service-kit A Carepac

X X X X

0005 0100
Examination according to operation manual

X X X*
* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. Visual check of the adsorption dryer and filters 2. Checking of the pre and after filter elements and exchange of the elements 3. Testing and cleaning of the condensate drains 4. Checking all valves, cleaning and lubrication if required 5. Checking and if necessary exchanging of the silencer elements 6. Checking all electrical components and indicator lamps 7. Checking the desiccant and exchanging it according to the service interval 8. Leakage-test under pressure 9. Test-run and adjacent controlling 10. Checking the switch-over of the adsorption dryer 11. New operation start-up of the dryer 12. Checking of the compressed air quality 13. Recording of the data and inspection contents in a service report

5 Years

19

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Heatless adsorption dryers Ultrapac HED, ALD, MSD HED, ALD, MSD Service inspection Service-kit A Recalibration dewpoint transmitter Carepac HED, ALD, MSD Service inspection Service-kit A Recalibration dewpoint transmitter Carepac
Option Ultraconomy Option Ultraconomy

0005 1000
Examination according to operation manual

X X X X

1350 - 8750
Examination according to operation manual

X* X* X X X
* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Visual check of the adsorption dryer and filters Checking of the pre and after filter elements and exchange of the elements Testing and cleaning of the condensate drains Checking all valves, cleaning and lubrication if required Checking and if necessary exchanging of the silencer Checking all electrical components and indicator lamps Checking the desiccant and exchanging it according to the service interval Leakage-test under pressure Test-run and adjacent controlling Checking the switch-over of the adsorption dryer New operation start-up of the dryer Checking of the compressed air quality Recording of the data and inspection contents in a service report

5 Years

20

12 Months

3 Years

Product
Remarks Purification package Oilfreepac OFP OFP Service inspection Service-kit A AK-Adsorber filling Recalibration dewpoint transmitter Carepac OFP Service inspection Service-kit A AK-Adsorber filling Recalibration dewpoint transmitter Carepac
Option Ultraconomy Option Ultraconomy

0005 1000
Examination according to operation manual

X X X* X X

1350 - 8750
Examination according to operation manual

X* X* X X* X X
* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Visual check of the adsorption dryer and filters Checking of the pre and after filter elements and exchange of the elements Testing and cleaning of the condensate drains Checking all valves, cleaning and lubrication if required Checking and if necessary exchanging of the silencer Checking all electrical components and indicator lamps Checking the desiccant and adsorber and exchanging them according to the service interval Leakage-test under pressure Test-run and adjacent controlling Checking the switch-over of the adsorption dryer New operation start-up of the dryer Checking of the compressed air quality Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

21

12 Months

3 Years

Product
Remarks Breathing air system Ultrapure ALG ALG Service inspection Service-kit A OX-Adsorber filling AK-Adsorber filling SP-Adsorber filling Recalibration dewpoint transmitter Carepac
Option Ultraconomy / central control system

35 S 375 S
Examination according to operation manual

X X X* X* X* X X
* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Visual check of the adsorption dryer and filters Checking of the pre and after filter elements and exchange of the elements Testing and cleaning of the condensate drains Checking all valves, cleaning and lubrication if required Checking and if necessary exchanging of the silencer Checking all electrical components and indicator lamps Checking the desiccant and adsorber and exchanging them according to the service interval Leakage-test under pressure Test-run and adjacent controlling Checking the switch-over of the adsorption dryer New operation start-up of the dryer Checking of the compressed air quality Recording of the data and inspection contents in a service report

5 Years

Type

24 Months

3 Months

6 Months

22

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

High Pressure Unit Ultradryer HLP PN 25 PN 40 HLP Service inspection Service-kit A Recalibration dewpoint transmitter Carepac Inlet filter Condensate drain Carepac Service inspection Service-kit A Service-kit B Recalibration dewpoint transmitter Carepac Inlet filter Condensate drain
Option: Ultraconomy Option: Electronic condensate drain Option Ultraconomy Option: Ultraconomy Option: Electronic condensate drain Option: Ultraconomy

0040 0155
Examination according to operation manual

X* X* X* X X X X X X* X* X X X X X X

0260 - 1200
Examination according to operation manual

X* X* X* X X X X X X* X* X X X X X X

* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Visual check of the adsorption dryer and filters Checking of the pre and after filter elements and exchange of the elements Testing and cleaning of the condensate drains Checking all valves, cleaning and lubrication if required Checking and if necessary exchanging of the silencer Checking all electrical components and indicator lamps Checking the desiccant and exchanging it according to the service interval Leakage-test under pressure Test-run and adjacent controlling Checking the switch-over of the adsorption dryer New operation start-up of the dryer Checking of the compressed air quality Recording of the data and inspection contents in a service report

5 Years

23

24 Months

12 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Heat regenerated adsorption dryers Ultradryer HRE / HRS / HRG 0375 - 8750 HRE / HRS / HRG Service inspection Service-kit A Service-kit B Desiccant analysis Recalibration dewpoint transmitter Service-kit B
Option Ultraconomy

0375 8750
Examination according ot operation manual

X* X* X* X* X* X*
* acc. to application

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Visual check of the adsorption dryer and filters Leakage test under operation pressure Checking the valves, cleaning and lubrication if required Checking of the dewpoint and the regeneration air cycle adjusting if required Checking and cleaning of the condensate drain as well as the silencer Checking of the regulator and the controller Checking the desiccant load Checking of all electrical components, relays and signal lamps Performance check of the electrical and pneumatic components Disassembly and checking of the filter elements Test-run and adjacent control Compressed air quality check Recording of the data and inspection contents in a service report

5 Years

24

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Oil/water separation systems UFS-SP, UFS-SP N, UFA-AC UFS SP / UFS-SP N Quality test Service inspection Carepac UFA-AC Service inspection Service-kit A Carepac 1 Scope of the service inspection UFS-SP 0008 0256
Examination according to operation manual

5 240
Testing of the waste water milkiness every 14 days Examination according to operation manual

X X

X X X

Scope of the service inspection UFA-AC

During each inspection the Donaldson service performs During each inspection the Donaldson service performs the following standard procedures: the following standard procedures: 1. Testing of the waste water quality and separation 2. Testing and if necessary adjusting of the oil outlet 3. Emptying of the oil canister in the suitable waste disposal vessel 4. A waste water sample has to be taken from the sample-tap 5. If the sample should be murky the desiccant needs to be changed 6. Emerging water should be tested for clearness 7. Emptying out and cleaning of the oil / water separator system 8. Exchange of the sedimentation tray and the coalescence filter 9. Exchange of the pre adsorber and the AKadsorbers 10. Operation start of the oil / water separator system 11. Checking of the flow 12. Recording of the data and inspection contents in a service report 1. Testing of the waste water quality and separation 2. Emerging water should be tested for clearness 3. Testing and if necessary adjusting of the oil outlet 4. Checking the parameter and the operations message 5. Emptying of the oil canister in the suitable waste disposal vessel 6. Test the filter element of the compressed air filter and change yearly 7. Empty and clean all vessels 8. Exchange of the sedimentation tray and the coalescence filter 9. Controlling the detergent supply and refilling the detergent 10. Controlling the condensate discharge collecting basin 11. Controlling the collecting basin 12. Special rinsing of the membranes with the service detergent 13. Operation start of the Ultraaqua with water 14. Checking of the flow 15. Adjusting of the level-measurement 16. Recording of the data and inspection contents in a service report

5 Years

25

12 Months

24 Months

3 Months

6 Months

3 Years

Product

Type Remarks

Chillers Ultracool UC UC Service inspection Service-kit A Carepac e Carepac c


Respectively for breakdown elimination * acc. to application

0010 1700
Examination according to operation manual

X X X* X*

Scope of service inspection


During each inspection the Donaldson-service performs the following standard procedures: 1. Check that the water temperature on the regulating thermostat display is approximately similar to that of the adjustable point 2. Check the ambient temperature and the condensation pressure (temperature). If the temperature difference exceeds 20C the condenser should be cleaned. 3. Check the evaporation pressure (temperature). If the temperature difference exceeds 8C, the evaporator should be cleaned. 4. Check that the pump pressure is similar to the nominal one (indicated on the characteristics plate). Adjust the pressure if necessary. 5. UC-MINI and UC-MIDI Standard series: check the condition of the wa ter filter if available 6. UC-MIDI Superplus: check the condition of the water filter casing (in the tank); if the pressure exceeds 0,5 bar the filter element should be exchanged 7. During device is turned off (main-switch off) the drain should be cleaned with a compressed air stream starting on the inside and working your way through the outside 8. Housing should be cleaned inside and outside especially taking care of cleaning the dust on the water pump frame 9. Filter elements should be changed and the water circulation should be replaced by clean water 10. Sticking on the service label 11. Recording of the data and inspection contents in service report

5 Years

26

12 Months

24 Months

3 Months

6 Months

3 Years

Product
Condensate drains UFM-T, UFM-P UFM-T Service inspection Service-kit A UFM-P Service inspection Service-kit A Scope of service inspection

Type Remarks 05 100 20HP


Examination according to operation manual

X X

Examination according to operation manual

X X

During each inspection the Donaldson-service performs the following standard procedures: 1. 2. 3. 4. 5. 6. 7. 8. Take the condensate drain out of operation (pressure-free and voltage-free) Cleaning of the condensate collection area Exchange of the consumable parts set when exchanging all seals Checking and cleaning of the control solenoid valve Cleaning of the dirt-collector (if available) Mounting and re-connection of the condensate drain Functional test Recording of the data and inspection contents in s service report

27

5 Years

Donaldson. And everything just got better.


Total Filtration Management
Donaldson offers a wide variety of solutions to reduce your energy costs, improve your productivity, guarantee production quality and help protect the environment. Compressed Air Filtration, Sterile Filtration, Process Filtration, Refrigerant Drying, Adsorption Drying, Condensate Drains, Condensate Purification Systems, Water Chillers, Air / Oil Seperation, Dust and Fume Removal, Process Air and Gas Processing, Oil Mist Separation

Total Filtration Service


A comprehensive range of services especially designed to keep your production at peak performance and at the lowest total cost of ownership. Donaldson Europe B.V.B.A. Research Park Zone Interleuvenlaan 1 B-3001 Leuven Belgium Phone +32 (0)16 38 39 70 Fax +32 (0)16 38 39 38 [email protected] Donaldson Filtration Deutschland GmbH Bssingstrae 1 42781 Haan Tel +49 (0)21 29 56 90 Fax +49 (0)21 29 56 91 00 [email protected] www.donaldson.com

Ultrafilter

You might also like