POWER PLANT CHEMISTRY

AFTER CATION CONDUCTIVITY(ACC)


What is After Cation
Conductivity(ACC)

• Cation Conductivity also known as


Acid Conductivity and Conductivity
After Cation Exchange (CACE) is the
measure of electrolytic conductivity of
a liquid sample after that liquid sample
has passed through an ion exchange
resin column containing cation resin in
the hydrogen form.
WHY ACC IS MEASURED

The measurement was adopted for monitoring the


power plant steam / water cycle as it can detect
low levels of anion contaminants such as
chlorides, sulphates, and organic acids (parts per
billion) on a continuous basis, while at the same
time the measurement is very simple and easy to
maintain.
Where ACC Measured?
Typically measured on Main Steam or Reheat Steam samples,
Condensate samples, Feed-water samples, and Boiler or Heat
Recovery Steam Generator evaporator drum samples

TYPICAL DIAGRAM OF A POWER PLANT


SIGNIFICANCE OF ACC
• In the power plant Steam-water cycle is maintained at a high
purity level to minimize the potential for corrosion and
deposition. This steam and water will typically be
conditioned with an alkaline chemical such as ammonia to
further reduce the potential for corrosion.
HOW ACC MEASURED
• In practice, a cooled sample of condensate or high purity water flows
through a cation exchanger in the hydrogen form. The cation resin
replaces contaminating cations such as Ca++, Mg++, Na+, NH4+, and
amines in the sample with hydrogen ions.
NaCl, KCl , CaSO4,MgCl , NH4OH etc
Contaminated Sample with minerals

+ Na+Cl- Na+ + HCl


(MINERAL) (ACID)
(CATION EXCHANGE RESIN)
CATION COLUMN

ION-EXCHANGE REACTIONS HCl, H2SO4, H2O etc


HOW ACC MEASURED…

• The hydrogen ions exchanged for the other cations in the


sample increase the conductivity contributed by the
contaminant salts of mineral acid anions listed above by 3 or 4
times. Thus the cation exchange column can be thought of as a
"conductivity amplifier" for mineral and organic acid
contaminants; increasing the sensitivity of the conductivity
analyzer to low levels of contamination. "

IN CASE OF CONTAMINATION

IN CASE OF NORNAL SAMPLE CONDITIONING


CATION COLUMN ARRENGEMENT
IN SWAS PANEL
CATION COLUMN ARRENGEMENT
IN SWAS PANEL

THREE-WAY VALVE

CONDUCTIVITY CELL

CATION COLUMN