Rian Ikbal / 705966
Configuring Operation
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 2
Comprehensive Management System Solution
OSS or integrated
NMS Service
Integrated NMS & OSS CORBA management
layer
CORBA CORBA
iManager T2100
Network
iManager T2100
MML MML MML
management
layer
iManager T2000 iManager T2000 iManager T2000
iManager T2000 NE
LCT
Qx Qx Qx Qx management
layer
NE layer
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 3
Introduction to Management Systems
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 4
Contents
Configuring Operation
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 5
T2000 Web LCT – Main Characteristics
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 6
T2000 Web LCT – Function
The T2000 Web LCT provides the following NE-layer management functions:
Service configuration (including PDH and SDH microwave services)
Protection configuration (intermediate frequency protection, SNCP, LMS
P)
Setting and query of the intermediate frequency attributes
Setting and query of the radio frequency attributes
Data services : support the 10M/100M fast Ethernet transparent transmi
ssion board EFT4 and L2 switching board EMS6
Setting and viewing of alarms and performance data
Communication and security
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 7
T2000 Web LCT – Application Scenario
Engineering Deployment
The commissioning engineer installs the Web LCT on a PC. And the
n configuring and commissioning the local or remote NEs by using t
he Web LCT.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 8
Contents
Configuring Operation
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 9
Configuration Operation
Managing NEs
Configuring radio links
Creating cross-connections of se
rvices
Configuring the clock
Configuring the orderwire
Customizing the alarm management
solution
Starting the monitoring of the N
E performance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 10
Web LCT Configuration – Logging In to an NE
Step1 Double-click the T2000 Web LCT shortcut icon on the desktop to launch the T2000
Web LCT.
Step2 The User Login screen is displayed. Enter the user name and password. Click Login.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 11
Managing NEs – Creating an NE
1. Click NE Search and specify the search criteria. Select the NE to be added to create a new
NE.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 12
Managing NEs – Creating an NE
2. Create an NE directly. Click the “Add NE” and Enter the information of the NE and
create the NE.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 13
Managing NEs – Logging In to an NE
Step 1: In the NE List, select the target NE and click NE Login.Then, the
IE displays the NE Login dialog box.
• Step 2:Enter the User Name and the Password. Then, click OK.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 14
Managing NEs – Modifying the NE ID
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 15
Managing NEs – Modifying the NE ID
Step 2 Click Modify NE ID. The system displays the Modify NE ID dialog box.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 16
Managing NEs – Modifying the NE IP
Select the NE from the Object Tree in the NE Explore. Choose Comm
unication > Communication Parameters from the Function Tree.
Set the IP.
Click Apply.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 17
Managing NEs – Configuring Logical Boards
Click the Slot Layout tab and click Add Logical Boards. Based on the slot layout, the NE
automatically configures the logical boards that are required but still not be configured for
certain physical boards.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 18
Managing NEs –Synchronizing the NE Time
Ensure that the time zone and time on the Web LCT computer are correctly set.
Select the NE from the Object Tree in the NE Explore. Choose Configuration > NE Time Localization
Management from the Function Tree.
Correctly set the time zone and daylight saving time (DST) of the NE depending on the location of the NE.
Click Apply.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 19
Managing NEs –Synchronizing the NE Time
Select the NE from the Object Tree in the NE Explore. Choose Configuration > NE Time
Synchronization from the Function Tree.
After the synchronization mode and relevant parameters are set, click Apply.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 20
Contents
Configuration Operation
Managing NEs
Configuring radio links
Creating cross-connections of se
rvices
Configuring the orderwire
Customizing the alarm management
solution
Starting the monitoring of the N
E performance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 21
Creating IF 1+1 Protection
Select the NE from the Object Tree in the NE Explorer. Choose Configuration > Link
Configuration from the Function Tree. Click the IF 1+1 Protection tab.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 22
Creating IF 1+1 Protection
Click New. The system displays the Create IF 1+1 Protection dialog box. Set the
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 23
Creating IF 1+1 Protection
IF 1+1 protection support external external switching operation. The external switching
priority from the highest to the lowest is Clear switching, Lockout switching, Forced
switching, Manual switching.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 24
Configuring the IF/ODU Information of a Radio Link
Select the NE from the Object Tree in the NE Explore. Choose Configuration > Link Configuration
from the Function Tree. Click IF/ODU Configuration. Click an IF board or ODU. Then, the system
displays the IF/ODU information of the radio link to which the IF board belongs. Set the corresponding
IF information of the radio link. Click Apply. Set the corresponding ODU information of the radio link.
Click Apply.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 25
Configuring the Parameters of IF Ports
Select the IF board from the Object Tree in the NE Explore. Choose Configuration > IF
Interface from the Function Tree. Click the IF Attributes tab. Here can set the working
mode, link ID, IF port loopback, 2M bit/s wayside service.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 26
Configuring the Parameters of IF Ports
Click the ATPC Attributes tab. Set each parameter for the ATPC attributes. The ATPC Enable
status, ATPC Upper Threshold, ATPC Lower Threshold, ATPC Adjustment can be configured here.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 27
Configuring the Parameters of ODU Ports
Select the ODU from the Object Tree in the NE Explore. Choose Configuration > ODU
Interface from the Function Tree. Click the Radio Frequency Attributes tab. Configure
the transmit frequency and T/R spacing. Click Apply.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 28
Configuring the Parameters of ODU Ports
Click the Power Attributes tab. Configure the transmit power of the ODU.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 29
Contents
Configuration Operation
Managing NEs
Configuring radio links
Creating cross-connections of servi
ces
Configuring the orderwire
Customizing the alarm management so
lution
Starting the monitoring of the NE p
erformance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Creating Cross-Connections of Point-to-Point
Services
In a cross-connection of point-to-point services, one service source corresponds to one
service sink. This operation is applicable to VC12, VC3, and VC4 SNCP services.
Procedure
Select the NE from the Object Tree in the NE Explore. Choose Configuration > Cross-
Connection Configuration from the Function Tree.
Note: Click Scheme to change the VC-12 timeslot numbering scheme used for the cross-
connections
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Creating Cross-Connections of Point-to-Point
Services
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 32
Creating Cross-Connections of Point-to-Point
Services
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 33
Contents
Configuration Operation
Managing NEs
Configuring radio links
Creating cross-connections of servi
ces
Configuring the orderwire
Customizing the alarm management so
lution
Starting the monitoring of the NE p
erformance
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 34
Configuring the Orderwire
Select the NE from the Object Tree in the NE Explore. Choose Configuratio
n > Orderwire from the Function Tree. Click the General tab. Configure th
e orderwire information.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 35
Browse Alarms
By using the Web LCT, you can browse the current and history alarms, the reporting status
of alarms for an NE and boards, and abnormal events.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 36
Adjusting the Alarm Management Function
Adjust the alarm management function of a board or port according to the service
availability, thus improving the alarm monitoring efficiency.
The common alarm management functions as list:
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 37
Starting the Monitoring of the NE Performance
Select the NE from the Object Tree in the NE Explore. Choose Performance > NE Performance
Monitor Time from the Function Tree.
Set the performance monitoring parameters according to the requirements. Normally, enable the
15-minute and the 24-hour performance monitoring at the same time
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 38
Browse Performance
You can browse the current and history performance data, UAT events, threshold
crossings, and performance monitoring status. You can set the performance
threshold and reset a board registry.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 39