NI ELVIS II Prototyping Board Pinouts
NI ELVIS II Prototyping Board Pinouts
NI ELVIS II Prototyping Board Pinouts
2 DIO 0 GROUND NC NC DIO 14 DIO 12 DIO 10 DIO 8 GROUND BoardID6 BoardID4 BoardID2 BoardID0 GROUND NC DIO 22 DIO 20 DIO 18 DIO 16 NC PFI 5 PFI 2 PFI 11 PFI 0 PFI 4 PFI 8 PFI 12 GROUND reserved AIGND AI 7+ SIDE B -15V -15V GROUND GROUND GROUND GROUND DIO 7 DIO 5 DIO 3 DIO 1 GROUND NC NC DIO 15 DIO 13 DIO 11 DIO 9 GROUND BoardID7 BoardID5 BoardID3 BoardID1 GROUND DIO 23 DIO 21 DIO 19 DIO 17 SB_PRES PFI 6 PFI 7 PFI 10 PFI 1 PFI 3 PFI 13 PFI 9 PFI 14 GROUND reserved AIGND AI 7-
41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62
AI 6+ AI 5+ AI 4+ AIGND AI 3+ AI 2+ AI 1+ AI 0+ AISENSE KEYWAY KEYWAY NC SYNC FGEN GROUND NC DUTBase GROUND AO0 GROUND Supply-
AI 6AI 5AI 4AIGND AI 3AI 2AI 1AI 0NC KEYWAY KEYWAY NC FM AM VCC GROUND NC DUT+ GROUND AO1 GROUND Supply+
Description
DC Power Supplies DC Power Supplies DC Power Supplies DC Power Supplies Digital input/output
BoardID<0..7>
SB_PRES
PFI <0..2>, Programmable Functions <5..7>,<10..11> Interface PFI 8 Programmable Function Interface PFI 9 Programmable Function Interface PFI 12 Programmable Function Interface PFI 3 Programmable Function Interface PFI 4 Programmable Function Interface PFI 13 Programmable Function Interface PFI 14 Programmable Function Interface AIGND Analog Inputs AI <0..7> Analog Inputs
+15 V Fixed Power Supply -15 V Fixed Power Supply +5 V Fixed Power Supply Ground Digital Lines P0.0 through P0.23 These channels are general purpose DIO lines that are used to read or write data. These eight lines signify the unique ID of each type of prototyping board by shorting them to VCC or to GROUND. This signal is used to indicate whether the prototyping board is inserted completely or not. It should be connected to VCC directly without the pull-up resistor. PFI Lines PFI Lines - Default function: Counter 0 Source PFI Lines - Default function: Counter 0 Gate PFI Lines - Default function: Counter 0 Out PFI Lines - Default function: Counter 1 Source PFI Lines - Default function: Counter 1 Gate PFI Lines - Default function: Counter 1 Out PFI Lines - Default function: Frequency Output Analog Input Ground Ground reference for the Analog Input signals. Analog Input Channels 0 through 7 Positive and negative input channels lines to differential AI channels.
AI SENSE
Analog Inputs
Analog Input Sense Reference for the analog channels in nonreferenced single-ended (NRSE) mode. Function Generator Output TTL output synchronized to the FGEN signal. Amplitude Modulation Input Analog input used to modulate the amplitude of the FGEN signal. Frequency Modulation Input Analog input used to modulate the frequency of the FGEN signal. Base excitation for bipolar junction transistors. Excitation terminal for Capacitance and Inductance measurements (DMM), Impedance Analyzer, 2-Wire Analyzer, and 3-Wire Analyzer. Virtual ground and current measurement for capacitance and inductance measurements (DMM), the Impedance Analyzer,2-Wire Analyzer, and 3-Wire Analyzer. Analog Output Channels 0 and 1 Used for the Arbitrary Waveform Generator. +5V Pull-up signal Positive Variable Power Supply Output of 0 to 12 V. Negative Variable Power Supply Output of 12 to 0 V.
FGEN SYNC AM
FM
Function Generator
Base DUT+
DUT-
AO <0..1>
Analog Outputs
Note: All the PFI lines can be configured as static digital I/O or Counter/Timer. When PFI lines are configured as Static Digital I/O, the mapping relationship in DAQmx is as follows: PFI<0..7> to P1.<0..7> PFI<8..14> to P2.<0..6> The diagram below shows the pin order of the connector with side B visible.