SGT 750 Brochure
SGT 750 Brochure
SGT 750 Brochure
Count on it.
The Siemens SGT-750 gas turbine is designed to meet the highest demands for efficiency, reliability, uptime and environmental compatibility. Combining years of experience and proven, cuttingedge technology with new ideas throughout the design process, the results are nothing less than impressive. Count on it.
and cycling capability both support intermediate to continuous operation with improved turndown capability, high efficiency and low emission levels. Through the use of a free power turbine, the 36 MWe SGT-750 is also well suited where grid requirements call for maintained power output in the event of frequency drop.
A complete solution.
The SGT-750 is delivered as a complete package. In a module that is just as carefully designed as the core engine, supporting systems and customized solutions interact to create an entity that delivers secured return on investment.
Footprint: Driver package: 12.8 x 4.3 (m) Power generation: 20.3 x 4.75 (m)
Siemens SGT-750
Proven technology. Perfected results.
6
1 2
9 6
7 5
Easy access and emission control This can design provides for excellent maintainability and easy-access exchangeability without casing disassembly. The fourth generation of Siemens DLE burners offer dual-fuel on-line switchover capability, increased power turndown range and emission control.
2 7
Online monitoring
All SGT-750 are mapped with infrared (IR) cameras during engine delivery test and during regular scheduled inspections. Early warning faster maintenance The IR cameras enable early detection of possible deviations, helping to keep the turbine in a good, healthy condition. The IR images also speed up the service procedure by giving accurate diagnostic information to technicians.
12
Built-in serviceability.
The design and construction of the SGT-750 was created with maximized serviceability and minimized load-to-load downtime in focus. To start with, the modular build-up facilitates swift disassembly and parts replacement. And with a 24-hour engine swap time, downtime can be kept to an absolute minimum.
34
68
102
136
A
On-site borescope inspections.
B
Hot sections parts replacement. Can be performed off-site using the replacement concept 34,000 and 102,000 hours.
C
Complete turbine overhaul can be performed off-site using the 68,000 hours replacement concept.
The figure shows scheduled maintenance of the SGT-750. With the option to choose from an on- or off-site maintenance concept during Level B and C inspection, downtime can be shortened with 10 and 11 days respectively if a replacement turbine is used leading to 17 maintenance days in 17 years. The schedule illustrated include time for other activities such as gearbox inspections and checkups of auxiliary equipment. Load-to-load engine swap time is just 24 hours.
13
Technical data.
Power generation 35.93 MW(e) Fuel: Natural gas Frequency: 50/60 Hz Electrical efficiency: 38.7 % Heat rate: 9296 kJ/kWh (8811 Btu/kWh) Turbine speed: 6100 rpm Compressor pressure ratio: 23.8:1 Exhaust gas flow: 113.3 kg/s (249.8 lb/s) Exhaust temperature: 462 C (864 F) NOx emissions (with DLE, corrected to 15 % O2 dry): 15 ppmV Mechanical drive 37.11 MW (49,765 bhp) Fuel: Natural gas Efficiency: 40.0 % Heat rate: 9002 kJ/kWh (6,362 Btu/bhp) Turbine speed: 3050-6405 rpm Compressor pressure ratio: 23.8:1 Exhaust gas flow: 113.3 kg/s (249.8 lb/s) Temperature: 462 C (864 F) NOx emissions (with DLE, corrected to 15 % O2 dry): 15 ppmV Extensive program for long-term service agreements Support program Preventive maintenance Corrective maintenance Full operation and maintenance program (O&M)
14
490
480
470
460
450
440
15
Published by and copyright 2010: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sector Oil & Gas Division Wolfgang-Reuter-Platz 47053 Duisburg, Germany Siemens Energy, Inc. 10730 Telge Road Houston, Texas 77095, USA Siemens Industrial Turbomachinery AB SE-612 83 Finspong, Sweden For more information, please contact our Customer Support Center. Tel: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: [email protected] Oil & Gas Division Order No. E50001-G430-A112-X-4A00 Printed in Sweden Dispo 34806, c4bs No. 7477, WS 11102.
Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.
www.siemens.com/energy