KPR-10 Percentage Biased Differential Relay Trainer is a rouged training system for the Electrical laboratories mounted
on Aluminum profile rack with sturdy table top flat panel. Each panel has ABS molded plastic sturdy enclosure with 4mm
shrouded connectors showing circuit diagram & its connection tag numbers for easy understanding and connections. The
product helps you to get fully acquainted with the basic concepts and functioning of a Percentage Biased Differential
Relay.

Specification
 Machine trainer having control panel provided in 30X30mm
Aluminum profile rack with 2 railing sturdy table top flat panel.
 Electrical Control panels are provided in Slidable ABS plastic panel
mounted on the aluminum rack with mimic diagram.
 Modular type flat panel carrying various high voltage components
housed in ABS plastic enclosure to minimize shock possibility.
 Modular & Slidable panel for easy site servicing not close control
 All input & output are terminated in 4mm BS-10 shrouded
connector, provided with 4mm shrouded cable for experiments.
 3 Phase AC Power Supply Panel - MP1
 4Pole 415V/4A MCB C Curve, Uimp 6kV, confirming to EN/IEC 60947-2
 9A Contactor with 230V / 50 Hz / 5VA COIL operating time 10-20ms, MOR-3600cyc/h, Uimp 8kV, confirming to
EN/IEC 60947
 Bimetallic Class 10 thermal O/L relay with range 1.6A - 2.5A, Uimp 6kV conforming to IEC 60947-4-1
 R-Y-B Input display Indicators.
 Manual start / stop with local trip contact

 3 Phase AC Measurement Panel (2nos)- MP3


 Bidirectional Multifunction
 3 Phase ¾ wire, 415V, CT Input 5A, Accuracy Class 1, Measurement CAT III
 Alphanumeric LED/LCD display, Aux supply 230V AC/DC, 45-65 Hz, 5W
 V,I, Hz, Pf, KVA, KW, KWH
 RS485 Communication Modbus RTU
 1 Phase AC Power Supply Panel - MP2
 1Pole 230V/4A MCB C Curve, Uimp 6kV, confirming to EN/IEC 60947-2 (2 No’s)
 Input Supply Indicators (2No’s).
 Lamp Load E27 Socket with ON/OFF 6A toggle Switch.
 Current & Elapsed Timer Panel (2No’s) - MP26/I/II
 AC Ammeter 20 A
 Counter Range 999.001 Sec
 Resolution 1 m Sec
 Voltage / Current Injector Panel (2No’s) - MP8/I/II
 Dimmerstat Input Voltage 230V AC, 50 Hz, Output Voltage 0-230V / 3A
 Short Circuit Transformer Input Voltage 230V / 3A AC, Output Voltage 0-2-8V / 12A taps
 Current Transformer Panel (2No’s) - MP27
 3 No’s of 5/5A CT
 Primary & Secondary Terminal brought out on 4mm BS-10 shrouded connector

TABLE TOP PANEL


 AC/DC Resistive Load Panel - MP20
 9 way Switch selectable 400W Resistive load of OFF/750E/600E/300E/212E/162E/125E/112E/100E + 60E Tap for DC
series Generator
 7 way Switch selectable 3 no’s of 400W Resistive load of OFF/10KΩ, 5KΩ, 3.5KΩ, 2.5KΩ, 2KΩ, 1.5KΩ
 Star Delta Transformer Panel
 3 Phase 1KVA Star-Star Transformer or Star-Delta Transformer
 Primary:0-415V, Secondary: 0-415V or 0-230V
 3 Phase Numerical high speed Percentage biased Differential relay
 Continuous display of sensing Phase current, Differential Current
 2 NO & 2 NC Trip contacts
 Current Rating 5A
 Wide setting range 10% - 50% for bias in steps of 5%

 Working Table - KWT-01 (Optional)


 MS Work Table Size 1200x750x850 (L x W x H), with four castor wheels including two lockable wheels with 3 Drawers
size of L450mm x W500mm x H200mm.
 ACCESSORIES
 Set of 4mm Shrouded Cables required for experiments
 Set of Manuals with Experiments.
 3 phase Dimmer input 415V/50Hz, Output 0-415V/3A (Optional)
 Demo CD showing Experiments (Optional)

 EXPERIMENT LIST
 Study of pick up test for differential relay
 Study of transformer out zone or non-trip faults.
 Study and plot characteristics of % biased differential relay
 Study of transformer protection for in zone trips faults