3gen 400-600
3gen 400-600
3gen 400-600
APPLICATIONS INCLUDE
Industrial equipment Test and measurement Telecommunications Peripherals Audio/broadcast Automation Linear and rotary motion
3A 3A 10A 3A
PRINCIPLE OF OPERATION
HIGH FREQUENCY MAGNETIC AMPLIFIER
385VDC BUS
L N E EMI FILTER
GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards Leakage current Weight (Note 11) Input/output Input/chassis (Note 9) 20ms typ after loss of AC power 82% typ. 3000VAC 1500VAC 200kHz IEC60950, UL1950 CSA22.2 No. 950 1.25mA, 250VAC, 60Hz 2.5kg LxWxH See AN105 270 x 127 x 65 mm 400,000 hours
See AN105 for individual module margin capabilities (Note 7) Zero 500ms 0.5V drop
Size MTBF
ENVIRONMENTAL SPECIFICATION Operating temperature (See derating curve) See AN105 -20C to +50C Derate 2.5% per C up to +70C -40C to +85C Non-condensing 5% to 95% RH 10-200Hz, 1.5G 3000 bumps, 10G (16ms) half sine
INPUT SPECIFICATIONS Input voltage range Input frequency range Inrush current Harmonic distortion NOTES
1 2 3 4 5 For higher power applications please see 6 slot datasheet. Outputs are user adjustable or factory set to your requested voltage. 25% to 75% load change. Whichever is greater. 20MHz bandwidth. (See AN105 for specification below 0C). Straight line on all outputs. On Module 70 current limit adjustable from 50% to 110%. Optional foldback on Module 70. Contact Cool Power Solutions Oy for details and AN105. 100V isolation between each output and 500V to chassis. All outputs except Module 70, which has 5.0% minimum load for full specification. Contact factory for 400Hz operation. For nominal output voltages and full load. The specifications contained in this data sheet are believed to be correct at time of publication. Specifications are subject to change without notice. This product is not intended for use as a stand alone unit and must be installed by authorised personnel in order to maintain approvals.
50%
6 7 8 9 10 11
Ambient Temperature C
QP AV
Connectors: J1 Line Input Connector J2 Options See AN105 for Pin-out J3 Output Signals See AN105 for Pin-out J4 Output Connector
1.38 (35.00)
AIRFLOW
7.87 (200.00)
1.38 (35.00)
J4
J3
J2
1.36 (34.70)
2.36 (60.00)
5.00 (127.00)
Accessories: 61069 Parallel Link 61070 Series Link 362D010 U Link OPCONN4 Mating Connector for options + Module 1-6 signals OPCONN6 Mating Connector for Module 70 signals
1.27 (32.30)
J1
0.39 (10.00)
1.63 (41.5)
All Dimensions Inches (mm) Mounting Holes [M4] on Base and Side Max screw penetration is 4mm
OUTPUT SIGNALS
Output control signals are available on all output modules. Modules 1 to 6 Power good signal Output inhibit signal Remote adjust (margin) Module 70 Additional Features (See AN105) Adjustable Current Limit Foldback or Straight Line Current limiting Bias Voltage Selectable Output Inhibit or Enable
(Dual output modules: output signals available on first [top] output only).
HOW TO ORDER
3G 4 C 1 2 2 5 - 05
Note: Calculate power requirements by summing output powers calculated at NOMINAL output voltages. Series Number of slots Power Slot A Slot B Slot D Slot C Option code
3
Specification of power supply detailed above:
4 slot series Maximum output power: 600W 5V @ 30A; 12V @ 20A; 12V @ 20A; 24V @ 3A; 24V @ 3A Mains Power Fail Signal + Logic Inhibit
Production configuration:
Units are shipped with nominal output voltages unless production configuration is specified. Excelsys can configure to your exact requirements, through use of appropriate parallel and series busbars and through voltage adjustment to specific set points. Please refer to configuration sheet for details (MD-3GCONFIG-05/00) and for part number assignment to our website at www.coolpowersolutions.fi
3gen FLEXIBILITY
Using Modules in Parallel
+S +V 0V -S
+S +V 0V -S
+S +V 0V -S
Notes: Maximum current = (I1 + I2) x .9 Use two parallel links (P/N 61069)
Notes: Maximum voltage to chassis is 500V Use series link (P/N 61070) Reverse bias diodes may be required for certain applications, eg. large capacitive loads Notes: Where the sensing point is remote from the output of the power supply, to avoid spurious noise pick-up it may be necessary to: 1 2 Use twisted pair sense wires. Use R C as shown (R1 = 100) (R2 = 10) (C = 22F).
Remote Sensing
R1
+S +V 0V -S
C + R2 C +
Notes: See Application Note AN105, or visit our website www.coolpowersolutions.fi for full details.
Input Mains Power Fail Signal AC OK... Optocoupler Conducting (See AN105)
Module Inhibit
Module Inhibit
Module Voltage