Curiba Site Layout

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

REPUBLIC OF THE PHILIPPINES

OFFICE OF THE BUILDING OFFICIAL


MUNICIPALITY OF CORELLA

RECOMMENDING APPROVAL AS TO:


8
LEGEND
HEAD ARCHITECTURAL SECTION:
SECTION DATE:
NO. FACILITIES AREA (SQ.M.) 13 12 9
7
1 BUILDING FOOTPRINT 90.00
11 5
2 CONSTRUCTION AREA 200.00
14 10
3 UTILITY 8.00 15 6
4 GUARD-HOUSE 10.00 BUILDING OFFICIAL: DATE:
16
5 EMPLOYEE PARKING 50.00
6 SITE OFFICE 15.00
7 WELFARE FACILITIES 34.00
8 PPE STORAGE 16.00
9 BUNKHOUSE 42.00
10 HEAVY-EQUIPMENT PARKING 129.60 3
11 PORTABLE TOILETS 12.50
1 4
12 OFF-LOADING AREA 26.95
13 FABRICATION AREA 19.95
14 MATERIAL STORAGE 40.00 2
15 EQUIPMENT STORAGE 16.80
16 WASTE MANAGEMENT 10.75

P
E
R
I M
E
T
2 SITE PLAN (3D MODEL)
E

E
R

N
C

F 5 SP1 NTS
E
N . 0
N

C 0
E
E

M
F
E

P
R
N

6.0 I V
0 P
R

R
A
I

O
5 4 P T
L

E
T

E
R A Careful planning and allocation of relevant facilities on the construction site are crucial for ensuring efficient and safe
E

T C
2
Y

Y C operations. Establishing facilities such as a bunkhouse, material and equipment storage, welfare facilities, a site office,
M

L E
S
T

utilities, portable toilets, an off-loading area, PPE storage, and a guard house ensures that the project runs smoothly and
I

I
N S
R
R

E
R that the well-being of the workers is prioritized.
E

O
E

A
P

D
P

3 The bunkhouse provides essential accommodation for workers, especially those coming from distant locations. This facility
O

6 minimizes travel time and ensures workers are well-rested and ready to start their day punctually, which is vital for
P
1
R

E
R maintaining productivity and meeting project deadlines. Material and equipment storage is essential for safeguarding tools
P

I
M
E and materials from theft, damage, and adverse weather conditions. Proper storage facilities help ensure that everything
T
10 E needed for construction is readily available and in good condition, which prevents delays caused by lost or damaged
7 R
F
E
materials.
N
C 1
E
Welfare facilities, including break rooms, dining areas, and first aid stations, are necessary for the health and morale of the
8 workforce. Providing spaces where workers can rest and take their meals comfortably increases productivity and reduces
13 the risk of accidents caused by fatigue. A well-equipped first aid station ensures that any injuries can be promptly
4 9 12 addressed, which is crucial for worker safety.

E
C
P

E
R
O N
P The site office serves as the command center for the project, allowing project managers and engineers to oversee
N
E
E

R
T
11 I activities, hold meetings, and maintain important documentation. It is central for coordination, planning, and communication,
F

Y
ensuring the project remains on schedule and any issues are promptly addressed. Utilities such as water and electricity are
L

L
I N
16
R

E indispensable for powering construction equipment and providing necessary services, ensuring that work can proceed
E

14 15 without interruption.
T

T
E

3
R

Portable toilets are essential for maintaining hygiene and sanitation on the construction site. Providing clean and
M

E
I

convenient facilities for workers helps maintain a healthy work environment. The off-loading area is designated for the
R

P delivery and unloading of materials. Having a specific area for this purpose helps manage the flow of materials efficiently,
E

R P
O

O E
P R
reducing potential disruptions and hazards.
P

E I M
R

R E
T T
Y E
P

L R
I N
E
F
E
N
PPE storage (Personal Protective Equipment) is vital for ensuring that all safety gear is properly stored and easily
C
E accessible to workers. This includes helmets, gloves, vests, and other protective gear necessary for safe construction

1 SITE PLAN LAYOUT practices. Ensuring that PPE is well-maintained and readily available reduces the risk of accidents and injuries on site.
Lastly, the guard house is crucial for security. It ensures constant monitoring of the site, preventing unauthorized access
and theft, and providing a sense of safety for both workers and equipment.
SP1 1:600 MTS 2
These facilities are indispensable for the effective, safe, and smooth operation of the construction site. By strategically
planning and assigning areas for these essential facilities, the project can proceed efficiently, ensuring the well-being of
workers and the successful completion of the two-storey residential building.

SEAL: PROJECT: OWNER: DATE NO. REVISIONS BY DATE SHEET CONTENT SHEET NO.
3.0 DESIGN ASSOCIATES JAN LLUMAR C. CURIBA
ARCHITECT SITE PLAN LAYOUT
SITE PLAN (3D MODEL)
PROPOSED TWO-STOREY RESIDENTIAL HOUSE MR. CHRISTIAN REY LUMANTAO
3F ARCHITECTURE DEPARTMENT, CEAID BUILDING, TEL (+63-032) 2550138
BISU-MC, NORTH CPG AVE., TAGBILARAN CITY, BOHOL 6300
NOTE: THIS DRAWING AS AN INSTRUMENT OF SERVICE IS A
PROPERTY OF THE ARCHITECT. AS SUCH, IT MUST NOT BE
REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT
REG.NO. : 012345

DATE : SEP 26, 2022


PTR NO. : 6789101

DATE : AUG. 17, 2024


CHECKED: JRO DRAWN: MAC SCALE
SP1
PERMISSION. ALL DRAWINGS ARE TO BE RETURNED TO THE
R.A. 545 TIN NO. : 123-456-789 AT : TAGBILARAN CITY ADDRESS: TANDAY, CORELLA, BOHOL 6337 ADDRESS: (BARANGAY), CORELLA, BOHOL 6337 AS SHOWN @ 20X30
ARCHITECT WHEN NO LONGER IN USE. APPROVED: BRS DATE: 10/02/2024