Smart Switch Modelo DS 3e1326p Si Hikvision

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

DS-3E1326P-SI

Smart Managed 24-Port 100 Mbps PoE Switch

Smart managed switches are developed by Hikvision, featuring easy management and maintenance. You can easily deploy,
monitor and expand your surveillance system anytime and anywhere with our software platforms. You can view the network
topology, monitor the health of the network and receive device alarms in real time, which greatly reduces the cost of
network operation and maintenance.

 24 × 100 Mbps PoE RJ45 port, 2 × gigabit combo.


 IEEE 802.3at/af standard for PoE ports.
 Network topology management, alarm push, network health monitor.
 6 kV surge protection for PoE ports.
 AF/AT camera can reach up to 300 m in extend mode.

Specification
General
Shell Metal material
Net Weight 2.83 kg (6.24 lb)
Gross Weight 3.33 kg (7.34 lb)
Dimensions (W × H × D) 440.00 mm × 44.00 mm × 221.00 mm (17.32'' × 1.73'' × 8.70'')
Operating Temperature 0 °C to 45 °C (0 °F to 113 °F)
Storage Temperature -40 °C to 85 °C (-40 °F to 185 °F)
Operating Humidity 5% to 95% (no condensation)
Relative Humidity 5% to 95% (no condensation)
Power Supply 100~240 V AC, 50/60 Hz, Max. 6.5 A
Installation Mode Rack (equipped with mounting ears)
Max. Power Consumption 400 W
Power Consumption in Idle 10 W
Surge Protection 6 kV
Network Parameters
Ports 24 × 10/100 Mbps PoE port,2 × Gigabit combo
MAC Address Table 16 K
Switching Capacity 14.8 Gbps
Packet Forwarding Rate 11.01 Mpps
Internal Cache 4 Mbits
PoE Power Supply
PoE Standard IEEE 802.3af,IEEE 802.3at
PoE Power Pin 8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-);
PoE Port PoE: Ports 1 to 24
Max. Port Power 30 W
PoE Power Budget 370 W
Software Function
Ports 1 to 24: up to 300 m.
Long Range
Long range performance may vary depend on camera model or cable condition.
Ports 1 to 24: port isolation mode to improve network security.
Port Isolation Ports in an isolation group cannot communicate with each other, but they can
communicate with ports outside the isolation group.
PoE Watchdog Ports 1 to 24: auto detect and restart the cameras that do not respond.
QoS is used to allocate bandwidth to different services so as to provide end-to-end
service quality assurance.
QoS
Support port-based priority configuration.
Support SP, WRR priority schedule mode.
Loop prevention is used to prevent the switching network from forming loops, which
will seriously affect network communication. Disabled by default.
Loop Prevention
Support 802.1D STP.
Suppport 802.1w RSTP.
VLAN is used for network scale planning and network health improvement.
Support 802.1Q.
VLAN Configurable VLAN ID from 1-4094.
Support Trunk, Access port mode.
Support Max. 4094 VLAN.
Support one-click activation and remote management via Hik-Partner Pro. Functions
supported:
1. Display the port rate.
2. Display the port bandwidth utilization rate.
HPP
3. Display topology information.
4. Display the alarm status.
5. Restart ports and devices.
6. Remotely upgrade the device.
Remote upgrade, default parameters recovery, logs viewing, basic network
System Maintenance
parameters configuration, import and export configuration, time sync
Port rate-limiting is used for port bandwidth adjustment to prevent network
Port Rate-Limiting
congestion.
Storm control is used to prevent switch ports from being blocked by broadcast or
multicast storms in the LAN, which may affect network communication.
Storm Control
Support port rate limiting based on broadcast, multicast, and unknown unicast
packets.
Approval
FCC (47 CFR Part 15, Subpart B);
CE-EMC (EN 55032: 2015, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN
EMC 50130-4: 2011 +A1: 2014, EN 55035: 2017);
IC (ICES-003: Issue 6);
RCM (ASNZS CISPR 32: 2015)
UL (UL 60950-1);
CB (IEC 60950-1:2005, AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second
Safety Edition);
CE-LVD (EN 60950-1: 2006 + A11: 2009 +A1: 2010+A12: 2011+A2: 2013, EN 62368-1:
2014+A11: 2017)
CE-RoHS (201165EU);
Chemistry WEEE (201219EU);
Reach (Regulation (EC) No.19072006)

Typical Application


Physical Interface
Front Panel

Rear Panel


Available Model
DS-3E1326P-SI
DS-3E1326P-SI V2

Dimension (Unit: mm)

Accessory
 Optional
HK-SFP-1.25G-1310-DF- HK-SFP-1.25G-20-1310-
HK-SFP-1.25G-20-1550 HK-SFP-1.25G-20-1310
MM DF
SFP Module SFP Module
SFP Module SFP Module

You might also like