IUW
Ultrasonic bulk water meter for use in drinking water distribution and industrial applications

The IUW ultrasonic bulk water meter is used to


record high and fluctuating flows in drinking water
distribution and in industry, with a very low pressure
loss at the same time. Two pairs of ultrasonic sensors
ensure optimum measurement accuracy. The IUW is
factory-fitted with a 9-digit LCD display and an NFC
interface. This enables a subsequent connection of
a wM-Bus (OMS) or LoRaWAN®-NDC module. Via the
plug and play function of the NDC module, the radio
technology set on the meter is automatically adopted
by the NDC module. All variants are approved for any
installation and are therefore also suitable for riser and
downpipe installation. A head-down mounting is also
possible. All materials, which are used in the drinking
water section, comply with the required standards,
guidelines and the current German drinking water
approval (other country-specific drinking water
approvals on request).

Performance characteristics at a glance Applications


■ Switchable radio technology ■ For measuring the consumption of cold and clean drinking
■ Highest precision and reliability even in case of low flow water or service water up to 50° C
rates ■ For measuring high flow rates
■ Protection class IP68
■ No moving parts in the flow sensor AMR options
■ Insensitive to deposits and particles ■ NFC interface (= Near Field Data Capture) for connecting
■ No straight inlet or outlet needed (U0/D0) according to an external NDC module and for device configuration
OIML R49 and DIN EN ISO 4064
■ Battery powered LCD register with NFC interface
■ Smart functions
■ Alarm and statistic functions
■ Galvanically separated NFC interface
■ Battery life > 15 Years
■ Operating pressure MAP 16
■ Approved in accordance with MID
■ Plug and play detection of radio technology via NDC
radio module
■ Configuration-App
■ Mechanical/electromagnetic environment class M2/E2
IUW

Technical data

Nominal diameter DN mm 50 50 65 65 80 80 100


Permanent Flowrate Q3 m³/h 25 40 40 63 63 100 100
Attainable measuring range Q3/Q1 R 500 800 500 800 500 800 500
Standard measuring range 1 Q3/Q1 R 500 500 500 500 500 500 500
Overload Flowrate Q4 m³/h 31.25 50.00 50.00 78.75 78.75 125.00 125.00
Overload Flowrate max. Q 4M m³/h 55.00 55.00 87.00 87.00 138.00 138.00 220.00
Minimum flowrate 2
Q1 m³/h 0.05 0.08 0.08 0.13 0.13 0.20 0.20
Transitional flowrate 2
Q2 m³/h 0.08 0.13 0.13 0.20 0.20 0.32 0.32
Lower measuring limit - l/h 25 25 40 40 63 63 100
min l 1 1 1 1 1 1 1
Display range
max m³ 999.999 999.999 999.999 999.999 999.999 999.999 999.999
Temperature range - °C 0.1 - 50 0.1 - 50 0.1 - 50 0.1 - 50 0.1 - 50 0.1 - 50 0.1 - 50
Operating pressure MAP bar 0.3 - 16 0.3 - 16 0.3 - 16 0.3 - 16 0.3 - 16 0.3 - 16 0.3 - 16
Pressure loss class at Q3 ∆p bar 0.16 0.25 0.16 0.25 0.10 0.10 0.10
Mechanical environmental condition - - M2 M2 M2 M2 M2 M2 M2
Electromagnetic ambient class 4 - - E2 E2 E2 E2 E2 E2 E2
Climatic environment 3 - °C 5 - 55 5 - 55 5 - 55 5 - 55 5 - 55 5 - 55 5 - 55
Flow profile sensitivity - - U0/D0 U0/D0 U0/D0 U0/D0 U0/D0 U0/D0 U0/D0

Dimensions and weights:

Nominal diameter DN mm 50 50 65 65 80 80 100


Overall length L mm 200/270 200/270 200/300 200/300 225/300/350 225/300/350 250/350/360
Height H mm 60 60 73 73 94 94 104
Height H1 mm 150 150 165 165 203 203 221
Width B mm 120x120 120x120 145x145 145x145 = D =D =D
Width B1 mm 135 135 150 150 <D <D <D
Flange diameter D mm 165 165 185 185 200 200 220
Bolt circle diameter D1 mm 125 125 145 145 160 160 180
Number of bolts - pcs. 4 4 4 4 8 8 8
Screw size - mm M16 M16 M16 M16 M16 M16 M16
Bolt diameter - mm 19 19 19 19 19 19 19
Weight approx. - kg 7.0/8.8 7.0/8.8 8.7/10.8 8.7/10.8 11.6/12.6/13.9 11.6/12.6/13.9 13.7/16.2/16.3

1
Other measuring ranges (R) on request
2
Values refer to standard measuring range
3
Condensation possible
4
During electromagnetic interference. there may be disruptions in the data transmission between the NFC interface and the NDC module. which can lead to a
lack of radio transmission. However. the counting progress on the measuring device itself is not affected.
Attention: not all versions are available in all markets

Dimensions

2
IUW

Technical data

Nominal diameter DN mm 100 125 125 150 150 200


Permanent Flowrate Q3 m³/h 160 160 250 250 400 400
Attainable measuring range Q3/Q1 R 800 500 800 500 800 500
Standard measuring range 1
Q3/Q1 R 500 500 500 500 500 500
Overload Flowrate Q4 m³/h 200.00 200.00 312.50 312.50 500.00 500.00
Overload Flowrate max. Q 4M m³/h 220.00 344.00 344.00 550.00 550.00 865.00
Minimum flowrate 2 Q1 m³/h 0.32 0.32 0.50 0.50 0.80 0.80
Transitional flowrate 2
Q2 m³/h 0.51 0.51 0.80 0.80 1.28 1.28
Lower measuring limit - l/h 100 100 250 250 250 400
min l 1 1 1 10 10 10
Display range
max m³ 999.999 999.999 999.999 9.999.999 9.999.999 9.999.999
Temperature range - °C 0.1 - 50 0.1 - 50 0.1 - 50 0.1 - 50 0.1 - 50 0.1 - 50
Operating pressure MAP bar 0.3 - 16 0.3 - 16 0.3 - 16 0.3 - 16 0.3 - 16 0.3 - 16
Pressure loss class at Q3 ∆p bar 0.10 0.10 0.10 0.10 0.10 0.10
Mechanical environmental condition - - M2 M2 M2 M2 M2 M2
Electromagnetic ambient class 4
- - E2 E2 E2 E2 E2 E2
Climatic environment 3 - °C 5 - 55 5 - 55 5 - 55 5 - 55 5 - 55 5 - 55
Flow profile sensitivity - - U0/D0 U0/D0 U0/D0 U0/D0 U0/D0 U0/D0

Dimensions and weights:

Nominal diameter DN mm 100 125 125 150 150 200


Overall length L mm 250/350/360 250 250 300/500 300/500 350
Height H mm 104 117 117 135 135 162
Height H1 mm 221 247 247 277 277 326
Width B mm =D =D =D =D =D =D
Width B1 mm <D <D <D <D <D <D
Flange diameter D mm 220 250 250 285 285 340
Bolt circle diameter D1 mm 180 210 210 240 240 295
Typische Fehlerkurve IUW
Number of bolts - pcs. 8 8 8 8 8 12
Screw size - mm M16 M16 M16 M20 M20 M20
Bolt diameter - mm 19 19 19 23 23 23
Weight approx. - kg 13.7/16.2/16.3 16.4 16.4 24.1/29.4 24.1/29.4 35.5
1
Other measuring ranges (R) on request
2
Values refer to standard measuring range
3
Condensation possible
4
During electromagnetic interference, there may be disruptions in the data transmission between the NFC interface and the NDC module, which
can lead to a lack of radio transmission. However, the counting progress on the measuring device itself is not affected.
Attention: not all versions are available in all markets

10
1,00
9
Pressure loss [bar]

8
7
6
5
Error in %

4
Fehler [%]

3
2
0,10
1
0
-1
-2
-3
-4
-5
-6
0,01
10 100 1000 10000 -7
-8 Q1 Q2 Q3 Q4
Flow rate [m /h]
3
-9 Flow rate [m3/h]
Pressure loss curve -10 Typical pressure loss curve Durchfluss [m³/h]
0,04 0,4 4 40

3
Subject to modifications and errors excepted. We accept no liability for any errors or misprints. SAP163479_240318_EN

ZENNER International GmbH & Co. KG


Heinrich-Barth-Straße 29
66115 Saarbrücken
Germany
Phone +49 681 99 676-30
Fax +49 681 99 676-3100
E-Mail [email protected]
Internet www.zenner.com