DB WMZ DFS Imf en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Technical data sheet

Flow sensor IMF for heat


and cold measurement
for nominal flows of qp 3.5 to 10 m3/h
as standard in metrological class 2 in accordance with DIN EN 1434-1

ZENNER offers a complete series for horizontal and


vertical installation positions with the type IMP flow
sensors. The flow sensors can be operated in a tem-
perature range from 5 to 120 °C and are therefore suit-
able for a wide range of applications from multi-family
houses to district heating measuring points.

All versions have an MID type examination certificate


and/or a type examination certificate for cold meters
in Germany and conformity assessment in metrologi-
cal class 2. So they fulfil the requirements of technical
guideline K9 of PTB for measuring points with nominal
sizes > qp 6.

The connection and construction dimensions corre-


spond to DIN EN 1434-2 and DIN EN ISO 4064. Further-
more flange versions are available with flange dimen-
sions corresponding to DIN EN 1092.

Product characteristics
■■ As standard for metrological class 2, fulfils the
requirement of technical guideline 9 of PTB
■■ Permitted temperature range: 5... 120 °C
■■ Suitable for water glycol heat carriers
(without conformity assessment)
■■ Downpipe and riser pipe versions also available in the
special short overall lengths 135 mm (for qp 3.5 and 6)
and 150 mm (for qp 10)
■■ Flange versions as standard in pressure stage PN 25
■■ Optimal for combination with the heat meter
calculator ZENNER multidata WR3 or
other standard calculators
Technical data sheet Flow sensor IMF

Technical data flow sensor model IMF

Nominal flow qp m³/h 3.5 3.5 6 6 6 6 10 10


Nominal diameter DN mm 25 25 25 25 32 32 40 40
Inch 1 - 1 - 1¼ - 1½ -
Overall length without connectors L2 mm 260 260 260 260 260 260 300 300
Overall length with connectors L1 mm 378 - 378 - 384 - 428 -
approx.
Thread meter G x B D1 Inch 1¼ Flange 1¼ Flange 1½ Flange 2 Flange
Thread connector R x D2 Inch 1 - 1 - 1¼ - 1½ -
Metrological class Standard: Class 2, optionally class 3 according to EN 1434
Installation position Horizontal (the register always has to face upwards)
Pulse value l/pulse 10 10 10 10 10 10 10 10
Pulse cable length m 1.5 / 3 (extendable by 7 m)
Maximum flow qs m³/h 7 12 12 12 12 12 20 20
Maximum flow (*) qi m³/h 0.14 0.12/0.24 0.12/0.24 0.12/0.24 0.12/0.24 0.12/0.24 0.2/0.4 0.2/0.4
Media temperature range °C 5 ≤ Θq ≤ 120
Pressure class PN/PS bar 16 (Connector) / 25 (Flange)
Highest permissible ambient temperature 55 °C
Ambient conditions / - climatic Lowest permissible ambient temperature 5 °C
influence figures Protection class IP 65
- mechanical class M2
- electromagnetic class E2
Pressure loss at qp bar ≤ 0.25

Water
Heat carrier water-glycol mixture (without conformity assessment)

Height H1 mm 160 160 160 160 160 160 174 174


H2 mm 40 40 40 40 40 40 50 50
Width B mm 95 95 95 95 95 95 110 110
Weight approx. kg 2.9 4.5 2.9 4.5 2.9 5.8 5.1 9.5

*
optionally

Dimensions IMF

2
Technical data sheet Flow sensor IMF

Technical data flow sensor model IMF-ST, IMF-FA

Nominal flow qp m³/h 3.5 3.5 6 6 6 10 10


Nominal diameter DN mm 25 25 25 25 32 40 40
Inch 1 1 1 1 1¼ 1½ 1½
Overall length without connectors L2 mm 135 150 135 150 150 150 200
Overall length with connectors L1 mm 253 268 253 268 274 278 328
approx.
Thread meter G x B D1 Inch 1¼ 1¼ 1¼ 1¼ 1½ 2 2
Thread connector R x D2 Inch 1 1 1 1 1¼ 1½ 1½
Metrological class Standard: Class 2, optionally class 3 according to EN 1434
Installation position Horizontal (the register always has to face upwards)
Pulse value l/pulse 10 10 10 10 10 10 10
Pulse cable length m 1.5 / 3 (extendable by 7 m)
Maximum flow qs m³/h 7 7 12 12 12 20 20
Maximum flow (*) qi m³/h 0.14 0.14 0.12/0.24 0.12/0.24 0.12/0.24 0.2/0.4 0.2/0.4
Media temperature range °C 5 ≤ Θq ≤ 120
Pressure class PN/PS bar 16
Highest permissible ambient temperature 55 °C
Ambient conditions / - climatic Lowest permissible ambient temperature 5 °C
influence figures Protection class IP 65
- mechanical class M2
- electromagnetic class E2
Pressure loss at qp bar ≤ 0.25

Water
Heat carrier water-glycol mixture (without conformity assessment)
206 (ST) 231 (ST)
Height H1 mm 195 195 195 195 195
197 (FA) 212 (FA)
Width B mm 95 95 95 95 95 110 110
Weight approx. kg 3.1 3.1 3.1 3.1 3.1 5.5 5.5

*
optionally

Dimensions IMF-ST Dimensions IMF-FA

3
Technical data sheet Flow sensor IMF

Nominal diame- Overall length Installation Pressure


Nominal size qp (m3/h) Connection Article number
ter DN (mm) position stage
3.5 25 260 Thread Horizontal PN 16 147981 / 157958*
3.5 25 260 Flange Horizontal PN 25 150218 / 157959*
3.5 25 135 Thread Riser pipe PN 16 150299
3.5 25 150 Thread Riser pipe PN 16 147982 / 163592*
3.5 25 135 Thread Downpipe PN 16 150300
3.5 25 150 Thread Downpipe PN 16 150301 / 157960*
6 25 260 Thread Horizontal PN 16 150302 / 157961*
6 32 260 Thread Horizontal PN 16 147983
6 25 260 Flange Horizontal PN 25 150303 / 157962*
6 32 260 Flange Horizontal PN 25 150304
6 25 135 Thread Riser pipe PN 16 150305
6 25 150 Thread Riser pipe PN 16 150306 / 163593*
6 32 150 Thread Riser pipe PN 16 147989
6 25 135 Thread Downpipe PN 16 150307
6 25 150 Thread Downpipe PN 16 150308 / 157963*
6 32 150 Thread Downpipe PN 16 150309
10 40 300 Thread Horizontal PN 16 147990 / 157964*
10 40 300 Flange Horizontal PN 25 150310 / 157965*
10 40 150 Thread Riser pipe PN 16 147991
10 40 200 Thread Riser pipe PN 16 150311 / 163594*
10 40 150 Thread Downpipe PN 16 150312
10 40 200 Thread Downpipe PN 16 150313 / 157966*
Pulse cable extension set, comprising: Cable connection piece with protection class IP 65 / 68,
152146
two-wire cable (length approx. 7 m, fitted with wire end ferrules), 2 adhesive seals
Versions for cooling meters in Germany (for consumption billing with cooling meters in Germany a separate domestic
*

type examination certificate and conformity assessment is required)

Technical data pulsers

Subject to technical modifications. We accept no liability for any errors or misprints. ZRI_SAP163937_190517_EN
Counter output
class according to EN 1434-2 OA
Switch variants Reed contact
Polarity reversal possible
Duration of the pulse ≥ 100 ms
Pulse break ≥ 100 ms
Bounce time ≥ 1 ms
Input magnitude 30 V
Greatest input current 27 mA
Protection resistor 68 Ohm
Pulse value In accordance with the details on the type plate
Connection line length, max. 25 m

ZENNER International GmbH & Co. KG


Römerstadt 6 | 66121 Saarbrücken | Germany
Phone +49 681 99 676-30 E-mail [email protected]
Telefax +49 681 99 676-3100 Internet www.zenner.com

You might also like