Owner`s Manual

GENERATOR

KB3800GF KB3800GFE KB5000GF

KB5000GFE KB6500GF KB6500GFE


-
-1-
KB8000GF KB8000GFE KB8000GFS

KB9000GF KB9000GFE GF9000GFS

IMPORTANT NOTICES

Please pay special attention to statements by the following words:

WARNING
A warning is used to alert the user to fact that hazardous operating and maintenance procedures may result in

injury to or death of personnel if not strictly observed.

CAUTION
A caution is used to alert the user to fact that hazardous operating and maintenance procedures may result in

-
-2-
damage to or destruction of equipment if not strictly observed.

NOTE
A note is used to give helpful information.

This manual should be considered as a permanent part of the unit and should remain with the unit when resold.

The installation and major repair work shall be carried out only by specially trained personnel.

Contents

SAFETY 5
Safety Label Locations 5
Safety Information 6
CONTROLS 9
Engine Switch 9
Recoil Starter 9
Fuel Valve Lever 10

-
-3-
Chock Rod 10
Ground Terminal 11
Oil Alert System 11
Circuit Breaker 12
GENERATOR USE 13
Connection to Building Electrical System 13
Ground Terminal 13
AC Applications 14
AC Operations 16
PRE-OPERATION CHECK 17
Engine Oil 17
Fuel 18
STARTING THE GENERATOR/STOPPING THE GENERATOR
20
SERVICE 20
MAINTENANCE 24
Maintenance Safety 25
Emission Control System Information 27

-
-4-
Maintenance Schedule 29
Engine Oil Change 30
Air Cleaner Service 31
Spark Plug Service 33
TRANSPORTING/STORAGE 36
ASSEMBLY OF PARTS 39
TROUBLESHOOTING 43
SPECIFICATIONS 45
WIRING DIAGRAM 46
OPEION EQUIPMENT 47

SAFETY

SAFETY LABELL LOCATIONS


These labels warn you of potential hazards that can cause serious injury. Read them carefully.
If a label comes off or becomes hard to read, contact your Generator dealer for a replacement.

-
-5-
NOTICE

Never remove the WARNING label.

SAFETY

SAFETY INFORMATION

Generators are designed to give safe and dependable service if operated according to instructions. Read and
understand this owner’s manual before operating your generator. You can help prevent accidents by being
familiar with your generator’s controls, and by observing safe operating procedures.

-
-6-
Operator Responsibility
·Know how to stop the generator quickly in case of emergency.
·Understand the use of all generator controls, output receptacles, and connections.
·Be sure that anyone who operates the generator receives proper instruction. Do not let children operate the
generator without parental supervision.

Carbon Monoxide Hazards


·Exhaust contains poisonous carbon monoxide, a colorless and odorless gas. Breathing exhaust can cause loss
of consciousness and may lead to death.
·lf you run the generator in an areas that is confined, or even partially enclosed, the air you breathe could contain
a dangerous amount of exhaust gas. To keep exhaust gas from accumulating, provide adequate ventilation.

SAFETY
Electric Shock Hazards
·The Generator produces enough electric power to cause a serious shock or electrocution if misused.

·Using a generator or electrical appliance in wet conditions, such


as rain or snow, or near a pool or sprinkler system, or when your

-
-7-
hands are wet, could result in electrocution. Keep the generator dry.

·If the generator is stored outdoors, unprotected from the weather, check all electrical components on the control
panel, before each use. Moisture or ice can cause a malfunction or short circuit in electrical components which
could result in electrocution.

·Do not connect to a building electrical system unless an isolation switch


has been installed by a qualified electrician.
·The circuit maintenance and installation need to be gone on by
professional , and meet the following standard;
1) Article 551 of the National Electrical Code ,ANSVNFPA 70-1990,and
2) The standard for Recreational Vehicles, ANSVNFPA 501 C-1990.

SAFETY

Fire and Burn Hazards


·The exhaust system gets hot enough to ignite some materials.
-Keep the generator at least 3 feet (1 meter) away form buildings and other equipment during operation
-Do not enclose the generator in any structure.
-
-8-
-Keep flammable materials away form the generator.

·The muffler becomes very hot during operation and remains hot for a while after stopping the engine .Be careful
not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors.

·Gasoline is extremely flammable and is explosive under certain conditions. Do not smoke or allow flames or
sparks where the generator is refueled or where gasoline is stored. Refuel in a well-ventilated area with the
engine stopped.

·Fuel vapors are extremely flammable and may ignite after the engine has started. Make sure that any spilled
fuel has been wiped up before starting the generator.
CONTROLS
Engine Switch

To start and stop the engine

Switch position:

OFF: To stop the engine.

-
-9-
ON: To run the engine. electric start recoil start

START:To start the engine (only for electric start)

NOTICE

If the start motor has not any respond, please check the circuit break off or on.

Recoil Starter
To start the engine, pull the starter grip lightly resistance is
felt, then pull briskly.
NOTICE
Do no allow the starter grip to snap back against the engine.
Return it gently to prevent damage to the starter.

CONTROLS

Fuel Valve Lever


The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the ON position, fuel is
allowed to flow from the fuel tank to the carburetor. Be sure to return the fuel valve
lever to the OFF position after stopping the engine.
-
- 10 -
Choke Rod
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed
by operating the choke lever manually. Pull the rod out toward CLOSED to enrich the mixture for cold starting.

CONTROLS

Ground Terminal
The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts
-
- 11 -
of the generator, and the ground terminals of each receptacle.

Before using the ground terminal, consult a qualified electrician, electrical inspector or local agency having

jurisdiction for local codes or ordinances that apply to the intended use of the generator.

Oil Alert System


The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the

crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will automatically

stop the engine (the engine switch will remain in the ON position). The Oil Alert system should not take place of

checking the oil level before each use.

If engine stops or not restart, check the engine oil level (see page 26) before troubleshooting in other areas

CONTROLS
CIRCUIT BREAKER
The AC circuit breaker will automatically switch OFF if there is a short
circuit or a significant overload of the generator at the receptacle.

-
- 12 -
If the AC circuit breaker is switched OFF automatically, check that
the appliance is working properly and does not exceed the rated
load capacity of the AC circuit before switching the circuit breaker
ON again.

The circuit breaker may be used to switch the generator AC power ON or OFF.

Voltage selector switch (only for dual voltage system)


The Voltage selector switch switches the main power carrying windings of the generator to produce “120V
ONLY” or “120V/240V”. If a 240V appliance is connected to the 4-prong receptacle, the switch must be in the
“120/240V” position. If only a 120V appliance is being connected to any of the120V 3-prong receptacles, select
the “120V ONLY” position.

CONTROL
Switch Position
120/240V: The 120Vand 120/240V receptacles can be used simultaneously.
120V ONLY: ONLY the 120V receptacles can be used. Do not use the 120/240V receptacle in this position.
The most power will be available at the 30A 120V locking plug receptacle.
-
- 13 -
GENERATOR
USE

Connections to Building Electrical System


Connections for standby power to a building electrical system must be made by a qualified electrician. The
-
- 14 -
connection must isolate the generator power from utility power, and must comply with all applicable laws and
electrical codes. A transfer switch, which isolates generator power from utility power, is available through
authorized generator dealer.
WARNING
Improper connections to a building electrical system can allow electrical current from the generator to back feed
into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines
during a power outage, and the generator may explode, burn, or cause fires when utility power is restored.
Consult the utility company or a qualified electrician.

Ground Terminal
The generator ground terminal is connected to the frame of the generator, the metal non-current carrying
parts of the generator, and ground terminals of each receptacle.
Before using the ground terminal, consult a qualified electrical inspector or local agency having jurisdiction for
local codes or ordinances that apply to the intended use of the generator.

GENERATOR
USE

AC Applications
-
- 15 -
Before connecting an appliance or power cord to the generator:
· Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical
shock.
·If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately.
Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of
the generator has been exceeded.
·Make sure that the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed
the maximum power rating of the generator. Power levels between rated and maximum may be used for no more
than 30 minutes.

NOTICE
Substantial overloading will open the circuit breaker. Exceeding the time limit for maximum power operation or
slightly overloading the generator may not switch the circuit breaker OFF, but will shorten the service life of the
generator.

GENERATOR
USE

-
- 16 -
AC OPERATION
1. Start the engine (see page 16).
2. Switch ON the AC circuit breaker.
3. Plug in the appliance .

NOTICE
·Be sure that all appliances are in good working order before connecting them to the generator. If an appliance
begins to operate abnormally, becomes sluggish, or stops suddenly, turn off the engine switch immediately.
Then disconnect the appliance and examine it for signs of malfunction.
·Most motorized appliances require more that rated wattage for startup. Do not exceed the current limit specified
for any one receptacle. If an overloaded circuit causes the AC circuit breaker to switch OFF, reduce the electrical
load on the circuit, wait a few minutes and then reset the circuit breaker.

PRE-OPERATION
-
- 17 -
CHECK

ENGINE OIL
NOTICE
Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils
will damage the engine and are not recommended.

Check the oil level BEFORE EACH USE with the generator on a level
surface and the engine stopped.
Use 4-stroke motor oil that meets or exceeds the requirements for API
service classification SJ. Always check the API SERVICE label on
the oil container to be sure it includes the letters SJ.

SAE 10W-30 is recommended for general, all-temperature use. Other


viscosities shown in the chart may be used when the average
temperature in your area is within the indicated range.

PRE-OPERATION
-
- 18 -
CHECK
1. Remove the oil filler cap and wipe the dipstick clean.
2. Check the oil level by inserting the dipstick into the filler
neck without screwing it in.
4. If the level is low, fill to the top of the oil filler neck with the
recommended oil.

Fuel
Check the fuel gauge, and refill the tank if the fuel level is low.
Refuel carefully to avoid spilling fuel. Do not fill above the shoulder of the fuel strainer.
WARNING
Gasoline is highly flammable and explosive, and you can be burned or seriously injured when refueling.
·Stop engine and keep heat, sparks, and flame away.
·Refuel only outdoors.
·Wipe up spills immediately.
Fuel tank capacity:
25L (6.6 US gal)

-
- 19 -
PRE-OPERATION
CHECK
NOTICE
Fuel can damage paint and plastic. Be careful not to spill fuel when filing your fuel tank. Damage caused by
spilling fuel is not covered under warranty.
Use unleaded gasoline with a pump octane of 86 or higher.
This engine is certified to operate on unleaded gasoline.
Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life,
Never use stale or contaminated gasoline or oil/gasoline mixture.
Avoid getting dirt or water in the fuel tank.
Occasionally you may hear a light “Spark knock” or “pinging”(metallic rapping noise) while operating under heavy
loads. This is no cause for concern.
If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of gasoline. If
spark knock or pinging persists, see an authorized to manual.

NOTICE
Running the engine with persistent spark knock or pinging is misuse, and the Distributor’s Limited Warranty dies

-
- 20 -
not cover parts damaged by misuse.
STARTING THE ENGINE/STOPPING THE
ENGINE

Starting the Engine


1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is
connected.
2. Turn the fuel valve lever to the ON position.
3. Turn the choke rod to the CLOSED position.
4. Move the engine switch to the ON position.
5. Pull the starter grip lightly until resistance is felt, then pull briskly.

NOTICE
Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the
starter or housing.
6. As the engine warms up, slowly push the choke rod to the OPEN position.

Stopping the engine


In an emergency:
To stop the generator in an emergency, turn the engine switch to the OFF position.

In normal use:
1. Turn the AC circuit breaker to the OFF position.
-
- 21 -
2. Turn the engine switch to the OFF position.
3. Turn the fuel valve lever to the OFF position.
SERVICE

Always do as the following so as to keep the generator in a sound condition.

WARNING
1. Always connect the 2.If the generator is to supply tow or above loads
generator to the earth or the Recreational with power supply, be sure to connect them one
vechicle to prevent misusing with wire. with higher start current fist.

-
- 22 -
Don’t move the earth wire during normal

maintenance or repair.
SERVICE

3. The following table gives reference information for connecting the electric appliances to the generator.

-
- 23 -
SERVICE

4. Connecting methods are illustrated as follow.


a) Correct b) Correct

c) Forbidden
WARNING
When connect the generator home power supply,
be sure that a skilled electrician dose this job.
Improper connecting between the generator and
-
- 24 -
loads may cause damage to the generator,
even a fire.

MAINTENANCE
The Importance of maintenance
Good maintenance is essential for safe, economical, and trouble-tree operation. It will also help reduce air
pollution.

WARNING
Improper maintenance, or failure to correct a problem before operation, can cause malfunction in with you can
be seriously hurt or killed.
Always follow the inspection and maintenance recommendations and schedules in this owner’s manual.

To help you properly care for your generator, the following pages include a maintenance schedule, routine
inspection procedures, and simple maintenance procedures using basic hand tools. Other service tasks that
are more difficult, or require special tools, are best handled by professionals and are normally preformed by
generators or other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If you operate your generator under sever
conditions, such as sustained high-load or high-temperature operation, or use it in unusually wet or dusty
conditions, consult your servicing needs and use.

-
- 25 -
Maintenance, replacement, or repair of the emission control devices and systems may be preformed by any
engine repair establishment or individual, using parts that are “certified” to EPA standards.
MAINTENANCE
Maintenance Safety
Some of the most important safety precautions follow. However, we can not warn you of every conceivable
hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a
given task.

WARNING
Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed.
Always follow the procedures and precautions in the owner’s manual.

Safety precautions
·Make sure the engine is off before you begin any maintenance or repairs. This will eliminate several potential
hazards:
----Carbon monoxide poisoning from engine exhaust.
Be sure there is adequate ventilation whenever you operate the engine.
----Burns from hot parts.
-
- 26 -
Let the engine and exhaust system cool before touching.

MAINTENANCE

----Injury from moving parts.

Do not run the engine unless instructed to do so.

·Read the instructions before you begin, and make sure you have the tools and skills required.

·To reduce the possibility of fire of explosion. be careful when working around gasoline. Use only a

nonflammable solvent, not gasoline, to clean parts. Keep cigarettes, sparks and flames away from all fuel-related

parts.

Remember that your servicing dealer knows your generator best and is fully equipped to maintain and repair it.

To ensure the best quality and reliability, use only new, genuine parts or their equivalents for repair or
replacement.

-
- 27 -
MAINTENANCE

Emission Control System Information


Soured of Emissions
The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of
hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form
photochemical smog when subjected to sunlight, Carbon monoxide does not react in the same way, but it is
toxic.
Engine utilizes lean carburetor setting and other systems to reduce the emissions of carbon monoxide, oxides of
nitrogen, and hydrocarbons.

Tampering and Altering


Tampering with or altering the emission control system may increase emissions beyond the legal limit. Among
those acts that constitute tampering are:
·Removal or alteration of any part of the intake , fuel , or exhaust systems.
·Altering or defeating the governor linkage or speed-adjusting mechanism to cause the engine to operate outside
its design parameters.

-
- 28 -
MAINTENANCE
Problems That May Affect Emissions
If you are aware of any of the following symptoms, have your engine inspected and repaired by your servicing
dealer.
·Hard starting or stalling after starting.
·Rough idle.
·Misfiring or backfiring under load.
·Afterburning(backfiring).
·Black exhaust smoke or high fuel consumption.

Replacement Parts
The emission control systems on your generators were designed, built, and certified to conform with
EPA and California emission regulations. We recommend the use of generators parts whenever you have
maintenance done. These original-design replacement parts are manufactured to the same standards as the
original parts, so you can be confident of their performance. The use of replacement parts that are not of the
original design and quality may impair the effectiveness of your emission control system.
A manufacturer of an aftermarket part assumes the responsibility that the part will not adversely affect emission
performance. The manufacturer or rebuild of the part must certify that use of the part will not result in a failure of
the engine to comply with emission regulations.

Maintenance
Follow the maintenance schedule on page 12.Remenber that this schedule is based on the assumption that
your machine will be used for its designed purpose. Sustained high-load or high-temperature operation, or use in
unusually wet or dusty conditions, will require more frequent service.
MAINTENANCE

-
- 29 -
Maintenance Schedule
REGULAR SERVICE PERIOD (3) Before each Fist month or Every 3 Every 6 Every year
ITEM Performed at every indicated use 20 Hrs. months or 50 months or or 300 Hrs.
Month or operating hour interval, whichever Hrs. 100 Hrs.
comes fist
· Engine oil Check level ○
Change ○ ○
· Air filter Check ○
Clean ○(1)
Replace ○*
· Spark plug Check-adjust ○
Replace ○
Spark arrester Clean ○
· Idle speed Check-adjust ○(2)
· Valve clearance Check-adjust ○(2)
· Combustion chamber Clean After every 500Hrs. (2)
· Fuel tank and filter Clean ○(2)
· Fuel tube Check Every 2 years (Replace if necessary) (2)

·Emission related items.


(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by an authorized generator dealer, unless the owner has the proper tools and is
mechanically proficient. See the Shop Manual.
(3) For commercial use, long hours of operation to determine proper maintenance intervals.
MAINTENANCE

ENGINE OIL CHANGE


-
- 30 -
Drain the oil while the engine is warm to assure rapid and complete draining.

1. Remove the drain plug and sealing washer, remove the oil filler cap, and drain the oil.
2. Reinstall the drain plug and sealing washer. Tighten the plug securely.
3. Refill with the recommended oil (see page 14) and check the oil lever.

Oil capacity:
1.1l (1.2US qt)

Wash your hands with soap and water after handing used oil.
Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you take it in
a sealed container to your local service station or recycling center for reclamation. Do not throw it in the trash,
pour it on the ground, or down a drain.

MAINTENANCE

-
- 31 -
Air Cleaner Service
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner
regularly. Service more frequently when operation the generator in extremely dusty areas.
NOTICE
Never run the generator without the air filter. Rapid engine wear will result.
1. Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element.
2. Wash the air cleaner element in a solution of household detergent and warm water, then rinse thoroughly, or
wash in nonflammable or high flashpoint solvent. Allow the air cleaner element to dry thoroughly.
3. Soak the air cleaner element in clean engine oil and squeeze out the excess oil. The engine will smoke
during initial startup it too much oil is left in the air cleaner element.
4. Reinstall the air cleaner element and the cover.

MAINTENANCE

Fuel Sediment Cup Cleaning


-
- 32 -
The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine
has not been run for a long time, the sediment cup should be cleaned.

1. Turn the fuel valve lever to the OFF position. Remove the sediment cup, O-ring, and filter.
2. Clean the sediment cup, O-ring, and filter in nonflammable or high flash point solvent.
3. Reinstall the filter, O-ring, and sediment cup.
4. Turn the fuel valve lever ON and check for leaks.

MAINTENANCE
Spark Plug Service
-
- 33 -
In order to service the spark plug, you will need a spark plug wrench (commercially available).
Recommended spark plugs: NHSP LD F7TC
To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.
If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler.
1. Remove the spark plug cap.
2. Clean any dirt from around the spark plug base.
3. Use a spark plug wrench to
remove the spark plug.
4. Visually inspect the spark plug.
Discard it if the insulator is cracked
or chipped. Clean the spark plug
with a wire brush if it is to be reused.
5. Measure the plug gap with a feeler gauge.
Correct as necessary by carefully bending the
side electrode.

The gap should be: 0.70-0.80 mm (0.028-0.031 in)

MAINTENANCE
6. Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent

-
- 34 -
cross-threading.
7. After the spark plug is seated, tighten with a spark plug wrench to compress the washer.
-If installing a new spark plug, tighten 1/2turn after the spark plug seats to compress the washer. If reinstalling a
used spark plug, tighten 1/8-1/4 turn after the spark plug seats to compress the washer.
NOTICE
The spark plug must be securely tightened. An improperly tightened spark plug can become very hot and could
damage the engine.
Never use spark plugs which have an improper heat range. Use only the recommended spark plugs or
equivalent.
Spark Arrester Maintenance
If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding.
NOTICE
The spark arrester must be serviced every 100 hours to maintain its efficiency.

MAINTENANCE

Clean the spark arrester as follows:


-
- 35 -
1. Loosen the screw by the exhaust port of the muffler and remove the spark arrester.
2. Use a brush to remove carbon deposits from the spark arrester screen.
Inspect the screen for breaks or tears and replace it if necessary.
3. Install the spark arrester in the reverse order of removal.

TRANSPORTING/STORAGE

-
- 36 -
When transporting the generator, turn the engine switch and the fuel valve OFF. Keep the generator level to
prevent fuel spillage. Fuel vapor or spilled fuel may ignite.

WARNING
Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine cool before
transporting or storing the generator.

Take care not to drop or strike the generator when transporting. Do not place heavy objects on the generator.

Before storing the unit for an extended period:

1. Be sure the storage area is free of excessive humidity and dust.


2. Service according to the table below:

TRANSPORTING/STORAGE

-
- 37 -
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARO STARTING
Less than 1 month No preparation required
1 to 2 months Fill with fresh gasoline and add gasoline conditioner*.
Fill with fresh gasoline and add gasoline conditioner*.
2 months to 1 year
Drain the carburetor float bowl.
Fill with fresh gasoline and add gasoline conditioner*.
Remove the spark plug. Put a tablespoon of engine oil into the cylinder. Turn the
engine slowly with the pull rope to distribute the oil.
1 year or more Reinstall the spark plug.
Change the engine oil.
After removal from storage, drain the stored gasoline into a suitable container,
and fill with fresh gasoline before starting.
*Use gasoline conditioners that are formulated to extend storage life.
Contact your authorized generator dealer for conditioner recommendations.

TRANSPORTING/STORAGE

-
- 38 -
Storage
1、 Drain the carburetor by loosening the screw.
Drain the gasoline into a suitable container.

WARNING
Gasoline is extremely flammable and is explosive under certain
conditions. Perform task in a well-ventilated area with the engine stopped. Do not smoke or allow flames or
sparks in the area during this procedure.
2、 Change the engine oil (see page 25-26).
3、 Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the
engine several revolutions to distribute the oil, then reinstall the spark plug.
4、 Slowly pull the starter grip until resistance is felt.
At this point, the piston is coming up on its compression
stroke and both the intake and exhaust valves are
closed. Storing the engine in this position will help
to protect is from internal corrosion.
ASSEMBLY OF
PARTS
-
- 39 -
Installation of battery
1. Put the battery on the frame of battery (Note: the pole face inside of the frame).
2. Hang one end of the tie rod in the holes both sides of the battery, then drill the other end through the holes of
fixing board.
3. Keep the fixing board to the edge of opposite side of poles.
4. Spin the M6 nut on the tie rod and reinforce it.
5. Connect the anode wire on the anode pole
and cover the red rubber lagging on the anode
pole. Connect the negative wire on the negative
pole and cover the black rubber lagging on the
negative pole.

ASSEMBLY OF
-
- 40 -
Battery use:
1. The specification of battery recommended: 12V, 9AH
2. Don’t connect the anode and negative pole erroneously, when use the battery.
3. The battery need to be injected electrolyte before use.
4. The height of electrolyte need to be inspected each month. When the height is low, please inject distilled
water or pure water between upper level and low level (Don’t use electrolyte and tap water).
5. The battery need to be clean. If the electrolyte is spattered on the generator set, the grounding and
down-lead will be eroded. Please wash them with water if erosion.

WARNING
1. The explosive gas will be happened when use the battery. So don’t close with fire, spark and reinforce of
grounding and down-lead.
2. The battery includes strong acid. Don’t spatter battery on your skin and in your eyes. If it happens, wash your
skin or eyes with water right now. if it very serious, go to the doctor for help.
3. Please note that if the battery is smirched by gasoline, oil or organic impregnant, the rind of the battery will be
damaged.
4. When replacing the new battery, please send the old battery to recycle bin. Don’t discard it optionally.

ASSEMBLY OF

-
- 41 -
PARTS
NOTICES

Check and make sure that the electrolyte level of each battery cell is between is upper and lower level marks

1. upper level mark 2.lower lever mark

Fig.19

In order to extend the life of the accumulator, please


pay attention to the maintenance of the accumulator.
Please inspect the electrolyte surface every month. If the electrolyte
surface decreases the lowest or protection board, add distilled water or pure water to the highest surface. Acid,
alkali, non-pure water (such as tap water, river water, sea water) are forbidden as supply liquid.
The accumulator after added liquid should be used in time. It should be charged regularly. if hasn’t been used for
a long time.
Charge requirement of the accumulator: charge 3 – 5hours according to 1/10 current of rated capacity of the
accumulator.
Avoid overcharge, overdid charge. Back charge is forbidden.

ASSEMBLY OF

-
- 42 -
PARTS
Wheel
Fit the four wheels to the generator with bolts and nuts.
Before starting the generator, press the lock system of wheels to prevent displacement during the work time.

TROUBLESHOOTING
-
- 43 -
When the engine will not start:
Is there fuel in the tank? NO
Refill the fuel tank.

YES

Is there enough oil in the engine? NO


Add the recommended oil.

YES
NO
Readjust gap and dry the spark
Is the spark plug in good
l R l it if
condition. YES
YES
YES NO Readjust gap and dry the spark
Is the spark plug in good plug. Replace it if necessary.

YES

To check:
If the engine still does not start,
take the generator to an 1) Turn off the engine switch and loosen the drain
authorized to manual.
screw.

-
- 44 -
SPECIFICATIONS
DF3800H DF5000H DF6500H DF8000H DF9000H
Model DFD3800H DFD5000H DFD6500H DFD8000H DFD9000H
DFY3800H DFY5000H DFY6500H DFY8000H DFY9000H

Rated Frequency 50Hz(60Hz)

Rated Power 3.0KW(3.5Kw) 4.0KW(4.5Kw) 5.0KW(5.5Kw) 6.0KW(6.5kw) 7.0KW(7.5KW)

Generator Max. Power 3.5KW(4.0Kw) 4.5KW(5.0Kw) 5.5KW(6.5Kw) 7.5KW(8.0Kw) 8.0KW(9.0KW)

Rate Voltage 230V(240V) 120/240V(110/220V)

Power Factor 1.0

DJ177FD DJ188FD DJ190FD


Model
(DJ177FD-B) (DJ188FD-B) (DJ190FD-B)

Type 4-stroke/air cooling/single cylinder/OHV horizontal shaft

Displacement 270cm3 389cm3 420 cm3

Ignition Model Transistorized Magneto

Engine Starting Model Recoil Start (electric start)

Max. Output 9HP/3600rmp 13HP/3600rmp 15 HP/3600rmp

Fuel Tank Capacity 25L(6.6Gal)

Oil Capacity 1.1L(0.29Gal)

Continuous Work
8Hr 8Hr 7Hr 7.5Hr 6.5Hr
Time (full load)

Dimensions
Generating 700mm×530mm×570mm(890mm×560mm×600mm)
(l×w×h)(mm)
set
Dry Weight (kg) 68kg(78kg) 80kg(92kg) 85kg(97kg) 88kg(98kg) 92kg(103kg)

-
- 45 -
WIRING DIAGRAM
R R R R
Ci r cui t Br eaker

Y/ G
Bl Bl

Bl
Y/ G
Y/ G +
Mai n coi l LB
LB

DC coi l 1 Bl Gr

Br Br
R R R
Bl
O O G
Br Br Y/ G
FS
Y/ G
E
W W Bl / W Bl
IG
R R
Bu Bu Bl / W LED D R Bl
O
Bu Bu Cont r ol panel bl ock
Bl / W Bl
Exci t at i on coi l Bl

R
O O
Magnet i c f i el d
coi l
W Bl / W Bl
Gener at or bl ock

O
i
l
f uel sol enoi d
f uel Spar k I gni t i on coi l
Engi ne bl ock Val ve
pr ot ect or pl ug
Bl Bl ack P Pi nk
I gni t i on swi t ch connect i ng
O Or ange Br / R Br own/ Red
- Bu Bl ue LB Li ght bl ue I G E FS G DF3800H- DF9000H WI RI NG DI ARAM
Gr Gr ay Y/ G Yel l ow/ Gr een ON - 46 - ( SI NGE VOLTAGE)
R Red W Whi t e OFF
Ci r cui t Br eaker
R R R W
R
Gr Socket
W W Socket
Y/ G
W W
Bl Bl Bl Bl Socket
Y/ G

Mai n coi l
W
Y/ G
Y/ G
WIRING DIAGRAM
Y/ G Cont r ol panel bl ock
LB Bl + Y/ G
Y/ G
LB
Gr R R
DC coi l 1 G P REMOT
Br / R Br / R
FS Br / R P START
Bl BAT O
Bu SYSTEM
Br Br ST Y/ G Bu Bu
E LB
IG LB
Br Br
DC coi l 2 R
W LED D

R Br / R
Br R Bl Bl
Bu O
Br / R
Bu Bu
Exci t at i on coi l O Bl / W
Bl / W
R
Bl
O Bu
Magnet i c f i el d Br O Bl / W Bl
coi l R
W
St ar t r el ay
Gener at or bl ock
W

Oi l al er t uni t
f uel sol enoi d
Char ge Coi l Bat t er y Mot or f uel Spar k I gni t i on coi l
Val ve
pr ot ect or pl ug Engi ne bl ock
Bl Bl ack P Pi nk
I gni t i on swi t ch connect i ng
O Or ange Br / R Br own/ Red

Bu Bl ue LB Li ght bl ue I G E BATST FS G
Gr Gr ay Y/ G Yel l ow/ Gr een
DFY3800H- DFY9000H WI RI NG DI AGRAM
OFF ( DUAL VOLTAGE)
R Red W Whi t e ON
St ar t

-
- 47 -
WIRING DIAGRAM

-
- 48 -
WIRING DIAGRAM
Ci r cui t Br eaker
R R R W
R
Gr Socket
W W Socket
Y/ G
W W
Bl Bl Bl Bl Socket
Y/ G
W Y/ G
Y/ G
Mai n coi l Y/ G Cont r ol panel bl ock
LB Bl + Y/ G
Y/ G
LB
Gr R R
DC coi l 1 G P REMOT
Br / R Br / R
FS Br / R P START
Bl BAT O
Bu SYSTEM
Br Br ST Y/ G Bu Bu
E LB
IG LB
Br Br
DC coi l 2 R
W LED D

R Br / R
Br R Bl Bl
Bu O
Br / R
Bu Bu
Exci t at i on coi l O Bl / W
Bl / W
R
Bl
O Bu
Magnet i c f i el d Br O Bl / W Bl
coi l R
W
St ar t r el ay
Gener at or bl ock
W

Oi l al er t uni t
f uel sol enoi d
Char ge Coi l Bat t er y Mot or f uel Spar k I gni t i on coi l
Val ve
pr ot ect or pl ug Engi ne bl ock
Bl Bl ack P Pi nk
I gni t i on swi t ch connect i ng
O Or ange Br / R Br own/ Red
- Bu Bl ue LB Li ght bl ue I G E BATST FS G
Gr Gr ay Y/ G Yel l ow/ Gr een
DFY3800H- DFY9000H WI RI NG DI AGRAM
OFF - 49 -
( DUAL VOLTAGE)
R Red W Whi t e ON
St ar t
WIRING DIAGRAM
Ci r cui t Br eaker
R R R R

Y/ G Y/ G
W
W W

Y/ G
Y/ G
Mai n coi l
Cont r ol panel bl ock
LB Bl + Y/ G
Y/ G
LB
Gr R R
DC coi l 1 G P REMOT
Br / R Br / R
FS Br / R P START
Bl BAT O
Bu SYSTEM
Br Br ST Y/ G Bu Bu
E LB
IG LB
Br Br
DC coi l 2 R
W LED D

R Br / R
Br R Bl Bl
Bu O
Br / R
Bu Bu
Exci t at i on coi l O Bl / W
Bl / W
R
Bl
O Bu
Magnet i c f i el d Br O Bl / W Bl
coi l R
W
St ar t r el ay
Gener at or bl ock
W

Oi l al er t uni t
f uel sol enoi d
Char ge Coi l Bat t er y f uel Spar k I gni t i on coi l
Val ve
pr ot ect or pl ug Engi ne bl ock
I gni t i on swi t ch connect i ng
- Bl Bl ack P Pi nk
O Or ange Br / R Br own/ Red I G E BATST FS G - 50 -
Bu Bl ue LB Li ght bl ue OFF
ON DFY3800H- DFY9000H WI RI NG DI ARAM
Gr Gr ay Y/ G Yel l ow/ Gr een
( SI NGE VOLTAGE)
R Red W Whi t e St ar t
WIRING DIAGRAM

R
R R W W
Ci r cui t Br eaker
Gr Socket Socket Socket
+
W W
Bl Bl Bl Bl

Cont r ol panel bl ock


Mai n coi l

Dc coi l 1

I gni t i on swi t ch
R R G
0 O FS
Br / R Br / R
Bu Bu BAT
ST
Y/ G Y/ G E
Bl Bl IG
Dc coi l 2
W
R Bl Bl
Bu
Bu
Exci t at i on coi l Bl / W Bl / W

Bl / W
Magnet i c f i el d Bl Bl
coi l R St ar t r el ay
Oi l al er t uni t

Gener at or bl ock
W

f uel sol enoi d


Char ge Coi l Bat t er y f uel Spar k I gni t i on coi l
Val ve
pr ot ect or pl ug Engi ne bl ock
Bl Bl ack P Pi nk I gni t i on swi t ch connect i ng
-
O Or ange Br / R Br own/ Red I G E BATST FS G- 51 -
Bu Bl ue LB Li ght bl ue OFF
DFD3800H- DFD9000H WI RI NG DI AGRAM
Gr Gr ay Y/ G Yel l ow/ Gr een ON
( VOLTAGE)
R Red W Whi t e St ar t
R
R R W W
Ci r cui t Br eaker
Gr Socket Socket Socket
+
W W
Bl Bl Bl Bl

Cont r ol panel bl ock


Mai n coi l

Dc coi l 1

I gni t i on swi t ch
R R G
0 O FS
Br / R Br / R
Bu Bu BAT
ST
Y/ G Y/ G E
Bl Bl IG
Dc coi l 2
W
R Bl Bl
Bu
Bu
Exci t at i on coi l Bl / W Bl / W

Bl / W
Magnet i c f i el d Bl Bl
coi l R St ar t r el ay
Oi l al er t uni t

Gener at or bl ock
W

Bl Bl ack P Pi nk f uel sol enoi d


Char ge Coi l Bat t er y f uel Spar k I gni t i on coi l
Val ve
O Or ange Br / R Br own/ Red pr ot ect or pl ug Engi ne bl ock
Bu Bl ue LB Li ght bl ue
I gni t i on swi t ch connect i ng
Gr Gr ay Y/ G Yel l ow/ Gr een
R Red W Whi t e I G E BATST FS G
OFF
ON DFD3800H- DFD6500H WI RI NG DI AGRAM
St ar t ( DOUBLE VOLTAGE)

-
- 52 -
OPTIONAL EQUIPMENT
Intelligence Protect Switch
1. When the load reaches the rated power, indicator light turns green.
2. When the load reaches the maximum power, indicator light runs red, the buzzer alarms.
3. When the load exceeds the maximum power for 1 minute, it automatically switches off the output.
4. Press the switch, the generator set works again.

Automatic Generator System (AGS)


After installation, be sure the machine is not overloaded. Once the electricity goes out, the generator will cut off
outside circuit, starting and generating automatically. As the outsides power-supply becomes normal, the
generator will cut off itself and connect the circuit automatically.
NOTICE
If machine cannot start, please check that whether the indicator glitters when start the machine. And add oil if it
glitters
1. Be sure the load won’t be overloaded, then install the generator set;
2. Usually , the AGS switch on the control panel will be on “automatic” position, and the key on “running”

-
- 53 -
position.
3. To put the choke switch on the “off” position.

OPTIONAL EQUIPMENT

Alarm System
1) The indicator light will be on when oil is insufficient and machine starts, the indicator light will be off

when oil is sufficient.

2) When the machine is running, the indicator will be on if the oil is insufficient, the indicator will be off

when oil is at critical position.

Clip battery

Fuel level indicator

-
- 54 -
OPTIONAL EQUIPMENT
Engine No.
remote start:

Aim remote start the gasoline engine (distance between more than 50m).

Requirement:

1. Turn off the machine manually after remote starting is acceptable;

2. Turn off the machine by remote key after manually start is acceptable;

3. Turn off the machine by remote key after remote start is acceptable;

4. Following is not acceptable when manually start and remote start:

(1) start

(2) turn off

(3) connect the fuel electromagnetism valve;

5. Once the remote start broken, manually start will be another option;
-
- 55 -
6. Remote start be useless after start;
OPTIONAL EQUIPMENT

7. After recoil start, remote turn off is acceptable;

Min. start voltage:6.2V

When turn off by remote key, it should last 8 seconds.

Remote start should last 4seconds.

WARING

Please make sure the 12V (DC) line connect to battery before starting, otherwise the remote start system will be

damaged during machine running.

-
- 56 -
-
- 57 -
-
- 58 -
-
- 59 -
-
- 60 -