Selcom Midi Supra V2 PDF 3 1 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

SELCOM

MIDI/SUPRA V2
LEARN PROCEDURE

Supported exclusively by Wittur UK

Preparation for learning:

 Take the car away from the landing doors (out of door zone).

 Mount the reference switch in any way, that the switch and magnet are opposite when the door panels are closed

 Service Drive has to be activated.

 Hold both test drive buttons until the motor gives a long buzz, and the service light comes on (Ser).

State

Service Drive

Reference Switch

Dip Switch S1/1

 Drive the doors closed using the test buttons. Make sure that the skate is relaxed when the buttons are released.
For fixed couplers, fully close the doors.

1
 If the skate is not relaxed, quickly press the door open button so that the skate relaxes but the door panels
don’t move.

 Switch the power off.

Learning of coupler width and door width (Standard):

 Switch power on. Put the drive into service mode and, using the test buttons, move door out of reference switch area
(Ref LED has to be off).

 Move the door by hand in close direction until door is fully closed (Ref LED is on).

 Press both test drive buttons for at least 6 seconds until the motor has vibrated 5 times.

 Release one of the test drive buttons (keep pressing one of them) door starts automatic learning.

 ATTENTION. The door panels will move as long as one of the service drive buttons is pressed. In case of any
mechanical malfunction, release the button and the door stops. A short stop of the door movement will not lead
to cancelling the automatic learning procedure.

 Hold the button until the door finished learning cycles (at least two door openings).

 Release the test drive button after the vibration of the motor signals end of learning and the State LED (ST) goes out.

 Press both service drive buttons to release the service mode (motor will vibrate and Ser LED will go out).

Learning of door width only (Fixed coupler):

 Switch power on.

 Press both test drive buttons for at least 6 seconds until the motor starts and has vibrated 4 times.

 Release one of the test drive buttons (keep pressing one of them) door starts automatic learning.

 ATTENTION. The door panels will move as long as one of the service drive buttons is pressed. in case of any
mechanical malfunction, release the button and the door stops. A short stop of the door movement will not lead to
cancelling the automatic learning procedure.

 Hold the button until the door finished learning cycles (at least two door openings).

 Release the test drive button after the vibration of the motor signals end of learning and the State LED (ST) goes out.

 Press both service drive buttons to release the service mode (motor will vibrate and Ser LED will go out).
2
Learning door width and coupler width without reference sensor:

 Turn off power, move door, by hand, from closed position to around 50mm in open direction.

 Switch on dip switch S1/1 and turn on power.

 Move door, by hand, into the close end position.

 Press both test drive buttons for at least 6 seconds until the motor has vibrated 5 times.

 Release one of the test drive buttons (keep pressing one of them) door starts automatic learning.

 ATTENTION. The door panels will move as long as one of the service drive buttons is pressed. In case of any
mechanical malfunction, release the button and the door stops. A short stop of the door movement will not lead to
cancelling the automatic learning procedure.

 Hold the button until the door finished learning cycles (at least two door openings).

 Release the test drive button after the vibration of the motor signals end of learning and the State LED (ST) goes out.

 Turn off dip switch S1/1.