Designed for

Ultrasound
your everyday
Affiniti
Stepping up to today’s Philips Affiniti ultrasound system
means stepping up to the next level of performance for
a con�dent diagnosis using streamlined work�ow.

Intuitive use
User interface and work�ow are shared across Affiniti
and EPIQ Elite ultrasound systems, aiding productivity. 21.5" monitor
Enhance user work�ow with automatic system
guided protocols that can be easily customized
to suit your needs

Tablet-like 12" touchscreen 12"


with work�ow-related controls for ease of use
touchscreen
At just 83.5 kg (184 lb), the system is
16% lighter than its predecessor system

Shared transducer family across Affiniti


and EPIQ Elite systems helps maximize your investment

Effective tools
Philips Collaboration Live* communication and
collaboration platform enables 100% of patient
consultations to be conducted using tele-health.**

Consumes nearly 40%


less power compared to our
legacy predecessor system

Battery backup with sleep mode allows


the system to sleep in 2 seconds and
return to full functionality in 20 seconds

Wireless networking aids work�ow

This printed copy is not an official Philips hard copy, use for reference only
* Contract required. Collaboration Live is intended for remote diagnostic use on Release 9.0 or higher.
** Based on responses from 107 participants. Results of customer case studies are not predictive of results in other cases. Results in other cases may vary.
Con�dent decisions

Tissue aberration Auto Doppler


correction for vascular imaging offers
color-box positioning and sample
provides superb imaging
performance across a
variety of MSK applications 67.9% volume placement in just three steps,
with an average of 67.9% fewer
button pushes¹
fewer button
pushes
1. Philips Auto Doppler Clinical Study, Dec. 2011.

Automatically Tissue Speci�c PureWave


adjust >
Presets (TSPs) imaging across all major clinical

7,500
parameters
automatically adjust over 7,500
parameters to optimize the
segments allows scanning of a
wide range of technically
transducer for the speci�c exam type difficult patients

Liver Fat Contrast-enhanced


Quanti�cation (LFQ) ultrasound (CEUS)
tools provide quantitative allows clinicians to study
ultrasound parameters to assist enhancement patterns of liver
physicians in the management lesions in real time, allowing
of patients with fatty liver disease for fast and con�dent diagnosis

Shear wave Fusion and navigation


elastography tool offers interventional radiologists
fast and effective fusion of CT, MR, PET
is non-invasive, reproducible
and easily used to assess or CBCT images with live ultrasound in
liver stiffness under one minute

Find out more at www.philips.com/GI

© 2022 Koninklijke Philips N.V. All rights are reserved. www.philips.com


Philips reserves the right to make changes in speci�cations Printed in the Netherlands.
and/or to discontinue any product at any time without
notice or obligation and will not be liable for any 4522 991 78041 * JUL 2022
consequences resulting from the use of this publication.
Trademarks are the property of Koninklijke Philips N.V.

This printed copy is not an official Philips hard copy, use for reference only
or their respective owners.