XHD Durt Tracker - Bastidor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

XHD DURT TRACKER ®

® Belt Cleaner
More than twice the size of ordinary belt cleaners,
XHD Belt Cleaners withstand
the most punishing conditions
above or below ground.
The XHD Belt Cleaners
provide effective carryback
removal in the face of high-
speed belts, large head
pulleys, high volumes or large
lumps of material, or other
conditions that spell trouble
for conventional cleaners.

Martin Engineering’s XHD DURT TRACKER® Belt Cleaners are protected by U.S. Patents #4,917,231; #4,658,949;
#4,953,689; and corresponding international patents issued and pending.

Features and Benefits:


◆No More Bent Mainframes
The undisputed heavyweight champion of carryback removal , the XHD Pre - Cleaner is built
rugged to stand up to abuse . Massive blades — more than twice as large as standard belt clean-
ers — are secured in all - metal track . Overhanging blade “skirts” keep material out of the track .
◆“Thinking Big” Reduces Service
Blades that are twice as big as conventional cleaners means they last longer. You’ll spend less
money on replacement blades, and less time installing them .
◆Simple Maintenance
Assembly, disassembly, and service of the XHD Pre - Cleaner requires only hand tools . To
remove blades , unbolt either side of track , or slide blade off either end .
◆CARP Constant Angle Blade Design
The XHD Pre - Cleaner uses rugged MSHA - accepted urethane blades with a 6 .5 in. (165 mm)
wear life . The patented “CARP ” constant cleaning angle provides effective carryback removal
with minimal pressure , reducing wear on blade , belt , and splice .

MARTIN ENGINEERING • ONE MARTIN PLACE • NEPONSET, IL 61345-9766 • USA


PHONE 1-800-544-2947 or 309-594-2384 • FAX 309-594-2432 © COPYRIGHT 1997
Form No.
Specifications L3370-01-2/00
Page 2 of 4
Maximum Belt Speed 1200 fpm (6.1 m/sec)
Maximum Service Temperatures Continuous 150° F (65° C)
Intermittent 180° F (82° C)
Minimum Head Pulley Diameter (Pre-Cleaner) 16 in. (400 mm)
Mounting Distance from Pulley Pre-Cleaner (pulley dia. > 30 in. [760 mm]) 4.75 in. (120 mm)
Secondary Cleaner 8.50 in. (216 mm)
Wear Life (Amount Of Usable Blade) Pre-Cleaner 6.5 in. (165 mm)
Secondary Cleaner Tungsten Carbide 1 in. (25 mm)
Other Blades 2 in. (50 mm)
Recommended Tensioner XHD Air Tensioner P/N 32135
XHD Spring Tensioner P/N 35392
XHD Dual Tensioner P/N 35392-2

XHD DURT TRACKER® XHD DURT TRACKER®


Pre-Cleaner Secondary Cleaner
15.50 (394)
15.17 (385)

10.05 (255)
12.50 (318)

Blade Specifications
Cleaner Blade Blade Blade Blade Replacement
Material Order Code Width Wear Life Blade
in. (mm) in. (mm) Part Number
Pre-Cleaner Urethane (Full) * 13.0 (330) 6.5 (165) 32136-13
Urethane (Half) * 6.5 (165) 6.5 (165) 32136-06

Secondary Tungsten Carbide T 9.0 (225) 1.0 (25) 32633-T


Chrome-Plated TC C 9.0 (225) 1.0 (25) 32633-C
Urethane U 9.0 (225) 2.0 (50) 32633-U
Stainless Steel S 9.0 (225) 2.0 (50) 32633-S
Mild Steel M 9.0 (225) 2.0 (50) 32633-M
Heat-Treated Steel H 9.0 (225) 2.0 (50) 32633-H

* High-performance urethanes are available.


Consult your Martin Engineering representative
for assistance in specifying nonstandard products.

MARTIN ENGINEERING • ONE MARTIN PLACE • NEPONSET, IL 61345-9766 • USA


PHONE 1-800-544-2947 or 309-594-2384 • FAX 309-594-2432 © COPYRIGHT 1997
Form No.
L3370-01-2/00
Page 3 of 4

XHD DURT TRACKER® Data


Number Belt Shipping
Maximum of Blades Coverage Weight
Belt Frame Track Dim. C
Width†† Length††† Length
in. (mm) in. (mm) in. (mm) Pre Sec Pre Sec Pre Sec
Dim. A Dim. B in. (mm) in. (mm) lb (kg) lb (kg)
18 (400-500) 54.81 (1392) 18.81 (478) 1.0 1 13.1 (333) 9 (229) 166 (75) 172 (78)
24 (500-650) 65.31 (1659) 25.31 (643) 1.5† 2 19.6 (498) 17 (432) 185 (84) 192 (87)
30 (650-800) 72.00 (1829) 32.00 (813) 2.0 3 26.2 (665) 25 (635) 210 (95) 222 (101)
36 (800-1000) 86.44 (2196) 38.44 (976) 2.5† 4 32.7 (830) 33 (838) 233 (106) 248 (112)
42 (1000-1200) 93.00 (2362) 45.00 (1143) 3.0 5 39.3 (998) 41 (1041) 258 (117) 276 (125)
48 (1200-1400) 107.50 (2731) 51.50 (1308) 3.5† 5 45.8 (1163) 41 (1041) 281 (127) 302 (137)
54 (1400-1600) 114.19 (2901) 58.19 (1478) 3.5† 6 45.8 (1163) 49 (1245) 305 (138) 326 (148)
60 (1600-1800) 128.63 (3287) 64.63 (1642) 4.5† 7 58.9 (1496) 57 (1448) 329 (149) 356 (161)
72 (1800-2000) 135.25 (3435) 71.25 (1810) 5.0 8 65.5 (1664) 65 (1651) 353 (160) 383 (174)
84 (2000-2200) 156.50 (3975) 84.50 (2146) 6.0 10 78.6 (1996) 81 (2057) 401 (182) 437 (198)
96 (2200-2400) 169.50 (4305) 97.50 (2476) 7.0 11 91.7 (2329) 89 (2261) 449 (204) 491 (223)
102 (2400-2600) 184.05 (4266) 104.05 (2643) 7.5† 12 98.2 (2494) 97 (2464) 473 (215) 518 (235)
108 (2600-2800) 191.05 (4675) 111.00 (2819) 8.0 13 104.8 (2662) 105 (2667) 497 (225) 545 (247)
120 (2800-3000) 204.00 (5182) 124.00 (3147) 8.5† 14 111.4 (2829) 113 (2870) 521 (236) 571 (259)

† For better belt coverage, a “half blade” is added to these assemblies.


†† Metric belt sizes are standard industry belting sizes rather than conversions.
††† End weldments telescope into track to eliminate need to cut mainframe during installation. Extra-long mainframes
are available. See your Martin Engineering representative for assistance in specifying nonstandard products.

XHD DURT TRACKER® Dim. C


Pre-Cleaner

Dim. B

Dim. B

14.13 (360)
Dim. A
Dim. C

Dim. A XHD DURT TRACKER®


Secondary Cleaner

MARTIN ENGINEERING • ONE MARTIN PLACE • NEPONSET, IL 61345-9766 • USA


PHONE 1-800-544-2947 or 309-594-2384 • FAX 309-594-2432 © COPYRIGHT 1997
Form No.
L3370-01-2/00
Page 4 of 4

XHD Mounts and Tensioners


Dual tensioners are required for belts 48 in. (1200 mm)
24.25 (616)
and over; add suffix “-2R” to belt cleaner part number.
XHD Flange Mount Air Tensioner P/N 32135
XHD Spring Tensioner P/N 35392 12.50
(318) 6.00
XHD Dual Tensioner P/N 35392-2 (152)

XHD “L” Bracket P/N 32339


XHD “Z” Bracket Assembly P/N 32481
XHD Corner Flange Bracket P/N 32818 4.00 (102)

Shock Ring Mount “L” Bracket P/N 33333 15.13 (384) Retracted
for use with Air Tensioner and CYA® Door 20.13 (511) Extended

XHD Flange Mount


XHD Spring Lever Hanger Mount P/N 27382-SL Air Tensioner

Accessories

XHD Air Contol Kit P/N 32181


XHD Air Control Kit P/N 32181-L
with Lockable Regulator
Lanyard Winch Assembly P/N 32263
CYA Inspection Door (18 x 24)
®
P/N 27658-1824

Cleaner Assembly Part Numbers


XHD Cleaner Assemblies include mainframe and
blades only; XHD Mounts and Tensioners must
be ordered separately.
XHD Spring Tensioner
XHD Pre-Cleaner
with Aluminum Track P/N 32333-XXXXX*
with Stainless Steel Track P/N 32133-XXXXX*
XHD Secondary Cleaner
with Aluminum Track P/N 32638-XXXX**
with Stainless Steel Track P/N 32639-XXXX** 12.00
3.00
(76) (305)

* Replace first XXX with belt width in inches and last XX with Blade Order Code
** Replace first XXX with belt width in inches and last X with Blade Order Code
(See Blade Specifications Chart)

16.50
(419)

8.75
(222)
XHD Spring Lever
Hanger Mount
Corner Flange Bracket

MARTIN ENGINEERING • ONE MARTIN PLACE • NEPONSET, IL 61345-9766 • USA


PHONE 1-800-544-2947 or 309-594-2384 • FAX 309-594-2432 © COPYRIGHT 1997