User Manual

Dear users:

Thank you for using our Company’ products.

Please read this guide seriously and storage carefully.

In order for you to better use and maintain this product, (here in

after referred as EV charging station).

The EV charger includes the high voltage circuit, low voltage

circuit. Please do not disassemble or refit by yourself.

The fault caused by this won't belong to the warranty.

Our company won't responsible for the injure caused by this.

This manual is used to use this product correctly, It's not the

configuration instruction of this product.

About the configuration status, please read the relevant contracts

of EV charger (if you have), or advisory the agency.

3
User Manual

CATALOGUE
CATALOGUE
Introduction

1 Product appearance and type --------------------------------page 7, 8

2 Product description of appearance

2.1 SES Charger -----------------------------------------page 9

2.2 E-stop and incoming line ------------------------------page 9

4.LED screen & Protect function -------------------------------page10

5.Technical parameters --------------------------------------Page11-17

6.How to charge --------------------------------------------page18

7. How to use wifi ------------------------------------------page19-32

8 How to install---------------------------------------------page32-47

9.FAQ-----------------------------------------------------Page48-51

10.Contact-------------------------------------------------page51

CATALOGUE

4
User Manual

Application:

EV charger is used to offer the AC power for the vehicle with an battery charger.

EV charger can be assembled in all kind of parking lot public, company and

community.

It is also can be assembled in kind of large, medium and small charge station.

It is suitable all kinds of parking lot unmanned, users can charge, pay, etc.

independently.

Supporting smart charging.

Supporting APP smart control (remote start charge, reserving charging, set

charging current, display and view charging status, etc. APP’s name is DUOSIDA

Charge, you can find it in Google play or apple store.)

Remark: smart charging require EV charger containing WiFi modules. WiFi modules are
optional.

5
User Manual

WARNING

It's may cause danger and harm, or damage the device if you don't in

accordance with safety guide.

Electrical and fire risk:

Don't use damaged and smudgy charge connector.

The electrical system for the connection of the EV charger must be inspected by

professional, meet the current requirements of the station, also installed a

residual current short circuit (RCB)

Don't follow the safety instructions can result in danger and injury, as well as

damage to the equipment.

Check the charging station and connector and see if there are any visible

damage before each use.

EV chargers can only be used to charge electric vehicles (EVs) or hybrid vehicles

(PHEVs).

Do not install the charging station in a closed container to avoid overheating.

6
User Manual

Brief instruction
Product appearance and type

SES Charger with cable

SES Charger with socket

7
User Manual

IEC Charging Mode: Mode3 Case C

IEC Charging Mode: Mode3 Case B

Remark: 1 For case B, You need to buy a charging cable separately.


2 (a) Socket-outlet, (b) Plug, (c) Cable, (d) Vehicle connector, (e) Vehicle
coupler, (f) Vehicle inlet, (g) Charging station, (h) EV socket-outlet, (i) EV
plug.

8
User Manual

Description of appearance

Arc status light

LED screen

Annular status light


Socket (2030)

Inlet wire Outlet wire (2080)

9
User Manual

Description of LED screen

Voltage Current KW/h Duration

Temperature

Protection Function

Over temperature protect Over current protect

Over voltage protect Low voltage protect

Leakage current protect E-stop switch

E-stop switch Lightning protection

Protection Class of Case


Indoor and outdoor use

10
User Manual

Technical parameters
The dimensions

11
User Manual

1.Style - wall mounted

Technical specifications:
Installation method: wall mounted
Maximum power: 22kW
Communication interface: (optional)
 GPRS ■ WIFI ■ RFID
Outdoor protection:
Without power supply - the waterproof protection
grade can reach up to IP55
With power supply-The waterproof protection grade
state can reach up to IP54,under coupling state
Safety regulation: Meet IEC 61851 and IEC 62196
Operating temperature:
ambient temperature - 30 ℃ to 50 ℃

Output type:
EN 61851-1 MODE 3 OR MODE 2
22KW:400VAC@32A

Basic functions:
Starting mode: charge when plug, smart charge for
APP
Reminder function: charging indication and fault
indication
Self-test function: fault self-position (can be checked
in the background after being networked)
Human-computer interaction:
Safety protection:
Double leakage detection and protection
Emergency stop button protection
Over current, over voltage, under voltage and over
temperature protection
Data record if Power off (can be checked in the
background system if being networked)
Surge protection meets the latest IEC 61851 standard
EMC meets the latest IEC 61851 standard

12
User Manual

2.Style - Stake

Technical specifications:
Installation method: stake-type mounted
Maximum power: 22kW
Communication interface: (optional)
 GPRS ■ WIFI ■ RFID
Outdoor protection:
Without power supply - the waterproof protection
grade can reach up to IP55
With power supply-The waterproof protection grade
state can reach up to IP54,under coupling state
Safety regulation: Meet IEC 61851 and IEC 62196
Operating temperature:
ambient temperature - 30 ℃ to 50 ℃

Output type:
EN 61851-1 MODE 3 OR MODE 2
22KW:400VAC@32A

Basic functions:
Starting mode: charge when plug, smart charge for
APP
Reminder function: charging indication and fault
indication
Self-test function: fault self-position (can be checked
in the background after being networked)
Human-computer interaction:

Safety protection:
Double leakage detection and protection
Emergency stop button protection
Over current, over voltage, under voltage and over
temperature protection
Data record if Power off (can be checked in the
background system if being networked)
Surge protection meets the latest IEC 61851 standard
EMC meets the latest IEC 61851 standard

13
User Manual

Charging plug

V4-DSIEC2b-EV32P V4-DSIEC2e-EV32P

Charging gun : Provide 16A / 32A for choosing

Superior protection performance, the protection

level reaches IP54 (working state)

Certification: CE & TUV

14
User Manual

Technical parameters (32A)

Product type SES-32 Charger with cable SES-32 Charger with socket

Rate voltage 400VAC 400VAC

The max output current 32A/Phase 32A/Phase

Operating frequency 50Hz/60Hz 50Hz/60Hz

The max output power 7-22KW 7-22KW

Human-computer
LED screen LED screen
interaction

Charging control mode Charge when insert Charge when insert

Charging connect type


Case C Case B
(IEC)

Standby power consumption 2W 2W

Communication mode / /

EMI CISPR22/EN 55022 CLASS B CISPR22/EN 55022 CLASS B

EN 61000-4-5 ±2KV/±4KV EN 61000-4-5 ±2KV/±4KV


EMS
perf. Criteria B perf. Criteria B

Executive standard EN 61851-1 & EN 61851-22 EN 61851-1 & EN61851-22

IP55(storage) IP55(storage)
Protection Level
IP54(Mated with vehicle) IP54(Mated with vehicle)

Operation -30-50℃/5%-95% -30-50℃/5%-95%

Temperature/Humidity (non-condensate) (non-condensate)

Altitude <2000m <2000m

Product Weight 6.5Kg 3.5Kg

Product Size 237mm×343mm×115mm 237mm×343mm×115mm

Installation Pedestal/wall installation Pedestal/wall installation

15
User Manual

Technical parameters (16A)

Product type SES-16 Charger with cable SES-16 Charger with socket

Rate voltage 400VAC 400VAC

The max output current 16A/Phase 16A/Phase

Operating frequency 50Hz/60Hz 50Hz/60Hz

The max output power 11KW 11KW

Human-computer
LED screen LED screen
interaction

Charging control mode Charge when insert Charge when insert

Charging connect type Case C Case B

Standby power consumption 2W 2W

Communication mode / /

EMI CISPR22/EN 55022 CLASS B CISPR22/EN 55022 CLASS B

EN 61000-4-5 ±2KV/±4KV EN 61000-4-5 ±2KV/±4KV


EMS
perf. Criteria B perf. Criteria B

Executive standard EN 61851-1 & EN 61851-22 EN 61851-1 & EN61851-22

IP55(storage) IP55(storage)
Protection Level
IP54(Mated with vehicle) IP54(Mated with vehicle)

Operation -30-50℃/5%-95% -30-50℃/5%-95%

Temperature/Humidity (non-condensate) (non-condensate)

Altitude <2000m <2000m

Product Weight(22KW) 5Kg 3.5Kg

Product Size 237mm×343mm×115mm 237mm×343mm×115mm

Pedestal/wall
Installation Pedestal/wall installation
installation

16
User Manual

Naming Technical specifications

Regulations IEC 61851-1

Charging power mode 3 3KW to 22 kW

Nominal voltage 230 V / 400 V / 1/3 AC

Rated current to 16 A adjustable from 6 to 32 A

in 1 A steps

Nominal frequency 50 Hz

connection technology Spring clamp technology

Charging connection / coupling Type 2

Length of charging cable 3,5 m, 5 m, 7,5 m

Operation / status information LED lights and LED screen

IP class IP55 (splash proof)

Residual current detection AC 30mA, DC 6 mA

Ventilation no ventilation is required

operating temperatur -30°C - + 50°C

Protection class I

Overvoltage category III

Certificaiton CE & TUV

17
User Manual

How to charge
SES Charger with
Module Function SES Charger with cable
socket

plug and charge ● ●

RFID module IC card charging ● ●

WiFi module Smart APP Charging ● ●

LED module LED screen display ● ●

LCD module The LCD display ○ ○

Full function
The main board Full function motherboard
motherboard

Light with Top indication ● ●

Light ring Bottom indication ● ●

Leakage current
Leakage protection ● ●
transformer

Current transformer Over-current protection ● ●

Over-voltage protection ● ●

Voltage transformer Under-voltage


● ●
protection

Over-temperature
Temperature sensor ● ●
protection

Emergency stop
Emergency stop ● ●
button

Incoming line through


● ●
terminal

Lightning protection
Lightning protection 10000A 8/20us 10000A 8/20us
device

High precision
Watt-hour meter ○ ○
measurement

Internal measurement ● ●

●Represents has this function ○ Does not have this function

18
User Manual

How to use wifi

1 Power on after the EV charger is installed

*1

*1:After the charger is turned on, the circular indicator light and the arc indicator light turn
red. At this time, the charger needs to be unlocked with the mobile phone APP.

2 Connect to the charger

2.1 In to the WiFi configuration mode


2.1.1 Use IC card to enter WiFi configuration mode

Press emergency stop switch


and swiping card

Please power on again and enter WiFi configuration mode in 2 minutes.

19
User Manual

2.1.2 Or use emergency stop switch to enter WiFi configuration mode

Press and release the


emergency stop switch
repeatedly for 3 times
within 10 seconds

2.2 Use your smart phone to connect the charger's WiFi

Find the network of DUOSIDA_XXXX,


enter the password: duosida@cp

Note: after being connected to the WiFi network of the charger, the mobile phone may
prompt that it cannot connect to the Internet and keep the current connection.

20
User Manual

3 Open the APP

*2

Click the screen to scroll down and


refresh until the list of charge points
appears. After successful activation,
the circular and arc indicators of the
charge point will turn blue

*2:If red appears here, please scroll down again to refresh

Click on and into the


charge point details
page

21
User Manual

4 charger details

Status Charge point


management

Current
Voltage

CP Status*3 Working time

Charged Internal temperature*4


KW/h

Start/Stop Device Setting


charging Schedule IC card
management

*3:Idle is for standby status, 9V is for prepare charging, and 6V PWM is for charging status.
*4 : This temperature for internal chip temperature, higher than the internal environment
temperature about 15 ℃.

22
User Manual

5 Charging procedure

5.1 Plug the charging plug into the electric vehicle charging socket.
5.2 Use the APP to enter the charging details page, and click the start charging button or use
IC card to start charging.

5.3 Click the stop charge button in the APP or use IC to stop charging.
Note: if you use the APP to start charging, then you need to click the stop button in APP
when you want to stop charging(the EV will automatically stop when it is fully charged), and
you must use the IC card to stop charging when you start charging by IC.

23
User Manual

6 Schedule setting

Scheduling tasks are three types:


1Absolute:
During the time period of the task, The charge performs charging according to the set time
point.
Example 1:

4.Send the schedule to


charge point

1.Set the task start time

2.Set the task end time

3. The smaller number means the higher priority task.

5.Click the “+” to add the schedule for charge.


Current can set the MAX charging current. If
write “0” will stop charge during this time, To
write “1” is bypass(the schedule does not to
manage charge point during this time)

24
User Manual

5.Click the Start to enable


task.

Clicking on the start time will affect the actual charging chart.

Click the Start from 6:00am


to 18:00pm

25
User Manual
The task activated between start time and end time only.
If you click the Start at 4:00AM, charger will work at default 32A.

Time period for task control

2Relative:
The charging chart is based from start time of charging session. Example 2:

This part setting same to


example1
“12Hour Later” and “18hour
Later” is from you click Start.

26
User Manual

Click Start before 6:00AM

A:click Start before 6:00AM

B:click Start at 8:00AM

3Recurring:
Loop execution can be set to cycle by day or cycle by week.
Example3:You want to charge from 8pm to next day 6pm on Mondays to Fridays, and all day
on Saturdays and Sundays. We can to set to two Recurring tasks.

27
User Manual

The first task ↑

The second task ↑

28
User Manual

7 IC card management system

For mobile phones that support NFC, special IC CARDS can be added to the IC card
management system of APP. IC card’s ID, effective time, maximum power. Among them, the
maximum available power information is stored on IC card, and other information is stored
in the cache of charger.

Please turn on the NFC switch


on your phone. The APP will
apply for the NFC usage
authorization. Please click the
permission, otherwise the IC
card cannot be added

Click <IC Card> to enter the IC card setting page.

29
User Manual

IC card ID

IC card
effectivetime

Input IC
card KW/h

Place the IC card that needs to be added near the NFC module of the phone. After reading
the information of IC card, the setting window will pop up. Set the KWh and click ok to add. If
there is no response, please change a few more areas to stick, or ask the mobile phone
manufacturer to confirm the location of the NFC module.

Put the IC card IC card enable


near the NFC
module of
mobile phone
again, then
activate the card

The charger owner use the APP to issue CARDS to the user according to the user's demand,
and sets the KWh limit of IC card according to the need. Which chargers can be used and
which chargers can not be used for the IC card set (all Settings are for offline storage, the
electricity information is saved on the IC card, and the authentication information is saved on
the charger);
3、 Use the specified IC card to the corresponding charger, and the card starts charging.
When the charge is completed, the charge can be stopped by swiping the card again.

30
User Manual
If you don't want to charge, you can cancel the current charge by simply swiping the card.
4、 When charging is completed, the user needs to swipe the card to end charging, and the
charge KWh on the card will be deducted from the charging process;
5、 When the balance of KWh on the card is insufficient, the user needs to find the owner to
add the KWh power;

Note: under this mode, the charger can not be open "Plug then charge mode", and “Stop
transaction on EV side disconnect” function can not be stopped by pulling the gun.

8 Charger status

There are 9 states of chargers. The current status information will be displayed on the
corresponding screen. Here is an explanation of 9 working states:
Name explanation
The charger is in an unusable state, under which the
charger cannot be charged:
1、 Charger is unavailable after power on, and needs to
Unavailable
be activated by mobile APP;
2、 In the upgrade state, WIFI will be switched to
unavailable
The charger is in a idle state, in which the user can operate
Available
the charger.
The charger is in the state of preparing charging. The
following situations will trigger the charger to enter the
state of preparation. If the charger enters the state of
preparation without charging, it will return to the state of
availability or charging completion after timeout:
1、 The charger will enter the preparation state when the
charger is inserted, but it still needs user
Preparing authentication to start charging (except the open
plug-in and charging mode). The timeout period for
the plug-in waiting for authentication is 120 seconds,
which can be configured in the APP;
2、 The phone will start charging remotely. If the user
does not have in plug, that will wait for the user to
put in;
3、 Swiping card when no plug inserted into the vehicle.
When all charging conditions are met, the charger will
Charging
enter the charging state.
When the working conditions of the charger are not
satisfied, the charger will enter the state of
SuspendedEVSE
SuspendedEVSE, and SuspendedEVSE will be triggered in
various cases::

31
User Manual
1、 Charger enters protection conditions, such as over
voltage, over current, over temperature, leakage,
emergency stop, etc.;
2、 In the charging process, the scheduling condition is
not satisfied, resulting in the active suspension of
SuspendedEVSE.
SuspendedEV mainly occurs when the S2 switch of the EV
SuspendedEV
is not closed.
1、 In the state of preparation, the charger will enter the
state of charging completion if the plug is inserted
Finishing and the device has timed out;
2、 The charging state will be entered after charge
finished
Reserved No support, not applicable to current charger.
Faulted Charger error occurred.

How to install

1. Installation Guide

1.1Safety and user information

Please observe all safety and user information,

Relevant local regulations for operating electrical

devices always apply.

Indicates:Risks arising from damage to the device

Risks for other users

Indicates:Dangerous electrical currents,

Dangers to life and limb

32
User Manual

Indicates:important information and

particularities

1. Suitable for garages, carports or outdoor as well

as for underground parking garages, apartment

blocks, hotel parking lots etc..

2. for wall mounting or freestanding with matching

Duostar stainless column,

3. IP class: IP 55(Splash-proof)

Charging station should not be directly exposed to

sunlight

The installation site must offer protection against

rain and running water or other liquids

Keep away from fire to ensure personal safety

The installation site must offer sufficient space

33
User Manual

We recommend that this product be installed in a

place that is rainproof and sun proof, or it can be

equipped with protective function. This can reduce

the possibility of failure and extend the life of the

product. If you need support, please contact your

supplier.

1.2 Safety and user information

The rated voltage must Charging station must be connected

be observed. to a protective earth conductor

34
User Manual

1. Ideally, the installation site should 1.Ideally, cable entry is

from

already provide for connection the underside of the

to the electricity grid. housing base

2. Otherwise, a power supply cable 2.Above or below surface

must be installed especially power supply possible

3. If unsure, please contact your

Specialist electrical contractor

Safety and user information

The power supply in the domestic power

distribution box must be protected separately

by a suitable and accurate dimension miniature

circuit breaker (C characteristic)

Complies with all technical safety requirements,

standards and guidelines.

Represents the current state of technology

DC fault current detection is required by law in

many countries

35
User Manual

1.3 Installation requirements

The installation surface The mounting substrate Minimum distances

measures at least must be level and firm to other technical

262 x 222 mm installations must be

(height x width) observed

The installation height is The installation site must be freely

be-tween 140 and 160 cm accessible

(floor to bottom edge of housing)

36
User Manual

1.4 Dos and don'ts

The charging cable must not be The charging cable and the charging

Under strain during the connector must not be driven over

charging process

The charging cable must not The charging cable must be coiled

be kinked or twisted tightly and stored.

37
User Manual

1.5 Installation notes

(De-)installation and repairs must only be

carried out by a specialist electrical contractor

No modifications must be made to the

charging station

None of the components need to be

maintained by the user

Different model has bit difference in size ,

appearance and function , The charging

station can be installed by yourself according

to the following installation procedure

38
User Manual

1.6Cleaning and maintenance

Charging station must only Maintenance must be checked

be cleaned using a dry cloth regularly

Cable must be checked regularly if there is any

damage or aging phenomenon

39
User Manual

1.7 The installation procedure

1.71 Installation tools

Electric drill Wrench adhesive tape bolt driver

Pliers The knife scissors pencil

screw hammer

40
User Manual

1.72 Installation process

1.First, stick the drawing on the 2.Drill holes in the four corners

wall with tape to decide the with an electric drill

drilling hole position

3. Knock the expansion screws in 4.Hang the mounting plate on

fixed holes with hammer he screw

41
User Manual

5.Tighten the screw with a wrench 6.Tighten the screw with a wrench

7.Hang the main body of the 8.Tighten the anti-theft screw to

charging station on the mounting ensure outdoor safety plate

42
User Manual

1. Use a pencil to draw location 10.Use an electric drill to make

where the hook needs to be punched holes in the drawing position

11. Drive the expansion screw in 12.Tighten the screw with a

with a hammer wrench

43
User Manual

1.7.3 Electrical connection


Requirements

Connect the wires to the RCD in sequence

Pay attention to the correct order when connecting.

Reversing the polarity of the cables will destroy the electronics of the wallbox.

Setting the charging current.

The charging current must never be set higher than the line fuse itself.

!!! ATTENTION !!!

If the wallbox is to be operated with an output of 11 kW, it must be protected with a

20 A fuse (over current protection).

Soll die Wallbox mit einer Leistung von 11 kW betrieben werden, ist diese mit einer

Sicherung von 20 A abzusichern.

If the wallbox is to be operated with an output of 22 kW, it must be protected with a

40 A fuse (over current protection).

Soll die Wallbox mit einer Leistung von 22 kW betrieben werden, ist diese mit einer

Sicherung von 40 A abzusichern.

44
User Manual

First commissioning

Pay attention to release the emergency stop switch

Arc-LED and cyclo-LED is blue

The nameplate is located to the left of the charger

You can start charge with plug in charging gun or use APP

the power supply has been established when arc-LED blink and cyclo-LED often on

Before the first commissioning the


According to “Ordinance on general conditions for grid connection and its use for electricity
supply in Low voltage (Low Voltage Connection Ordinance - NAV)“ in §19 the following
points have to be clarified with the network operator:
„Section 19 Operation of electrical systems, consumables and charging devices, own systems
(1) The system and consumables are to be operated by the connectee or user in such a way
that faults occur other connectees or users and disruptive repercussions on network
operator facilities or Third parties are excluded.
(2) Extensions and changes to systems as well as the use of additional consumer devices are
the
Notify network operators if this increases the capacity to be maintained or with network
repercussions is to be expected. Charging devices for electric vehicles are also prior to
commissioning to communicate. Their commissioning also requires the prior consent of the
network operator, if their total rated power exceeds 12 kilovoltampere per electrical system;
is the network operator in this case, obliged to express itself within two months of receiving
the notification. Is that true Network operator, he has the impediment, possible remedial
measures of the network operator and the Connected party or user and a time required for
this by the network operator. The network operator can regulate details of the content and
form of the messages.
(3) The connectee or user must notify the network operator before setting up his own system
do. The connectee or user must take appropriate measures to ensure that his Own plant no
harmful repercussions in the electricity supply network are possible. The connection of own
systems is to be coordinated with the network operator. This can be the connection of
compliance with the make it dependent on measures to be taken to protect against reverse
voltage in accordance with Section 20.“

45
User Manual

- before the first commissioning with an electric car the following tests must be carried out
with an adapter for vehicle simulation (CP) according to VDE 0122-1:

- For planning, installation, operation and use, please follow the “Der Technische Leitfaden
– Ladeinfrastruktur / Elektromobilität (Version 3)” [Editor: DKE, bdew, ZVEH, ZVEI, & VDE]

46
User Manual

Environment

o This device is used to charge electrically operated Vehicles and is


subject to the EU directive 2012/19 / EU on waste electrical and
electronic equipment(WEEE).
o Disposal must be according to national and regional Regulations for
electrical and electronic equipment respectively.
o Old devices and batteries must not be disposed of with household waste
or bulky waste. Before the device disposed of should it be rendered
inoperable.
o Dispose of the packaging material in the Your region's usual collection
container for cardboard, paper and plastics.

47
User Manual

FAQ
Display information
Status indicator light meaning

Condition Arc power indicator light Circular status indicator light Remarks

E-stop Red often on Red often on

Standby Blue breathing lamp Blue breathing lamp

Prepare for Simple one has no this


Green often on Green often on
charging state

Charging Green often on Green breathing lamp

End of Individual models have


Green often on Blue often on
charging no this state

Electric leakage Red breathing lamp Red breathing lamp

Over voltage
Red often on Blue often on
Less voltage

Over current
Red often on Green often on
protection

Over
temperature Red often on Blue breathing lamp
protection

Hardware
Red often on Green breathing lamp
failure

Power off Not bright Not bright

Maintenance Notes
Check whether the line is aging with the monthly power cut .
Conduct leakage test on the external leakage protector to ensure the normal operation
of the leakage protector.
Oberve incoming lines to make sure no wires is damaged.

48
User Manual

Breakdown and maintenance

The meaning of the error code


Display code Meaning of code Solution
Please ensure safety before releasing the
0x00010001 The emergency stop switch is triggered
emergency stop switch
Reserved, without this function, temperature control
0x00010002 Over Temperature
sensor must be connected
0x00010003 Over current protection Please ensure that safe and start charging
0x00010004 Over voltage Protection Please ensure that safe and start charging
0x00010005 Low-voltage protection Please ensure that safe and start charging
Abnormal code of modules outside the main board

Maintenance or professional personnel are required


0x00020001 The LCD screen anomaly
to check the connection or replacement

0x00020002 The OLED screen anomaly Without this function. Reserved,

Maintenance or professional personnel are required


0x00020003 The RFID screen anomaly
to check the connection or replacement

Abnormal measurement module of Maintenance or professional personnel are required


0x00020004
cover meter to check the connection or replacement

GPRS communication module Maintenance or professional personnel are required


0x00030005
communication abnormal to check the connection or replacement

0x00030006 Electric lock exceptions Reserved,

Abnormal current voltage detection Professional personnel are required to repair or


0x00030010
module return to the factory

Professional personnel are required to repair or


0x00030011 System voltage monitoring anomaly
return to the factory

Professional personnel are required to repair or


0x00030011 System current monitoring anomaly
return to the factory

Professional personnel are required to repair or


0x00030020 System relay abnormal
return to the factory

Professional personnel are required to repair or


0x00030021 System relay cannot be opened
return to the factory

Professional personnel are required to repair or


0x00030022 System relay cannot be closed
return to the factory

Abnormal built-in leakage Professional personnel are required to repair or


0x00030030
protection module return to the factory

49
User Manual

Safety tip
The people who assemble and use the EV charger must response the follow principle

and rule, to confirm the relevant people and device operation normally:

Before device power on, please confirm the device is good earth, to avoid the

unnecessary accident.

All of the tools must be insulating treatment to avoid the short circuit or

personal injury due to uncovered metal touches metal frame.

Don’t refit, add and change any parts whatever any condition.

Confirm the EV charger using life and operation steadily, the device should

keep cleaning, constant temperature and constant humidity as possible. The EV

charger mustn’t use in the environment that contain volatile gas or flammable-explosive

environment.

The input voltage, frequency, device breaker of equipment must be confirmed that

conform to stipulation.
Safety sign
v
Caution: this sign represents it would create danger for costumer

or damage the hardware seriously if operate improperly.

Danger: this sign represents it would create danger for costumer or

damage the hardware seriously if operate improperly.

Caution

Danger!
It would create danger if operate isn’t accord with stipulation.

The EV charger using should accord with technical running normally and

operation safety.

Children mustn’t touch EV charger.

The EV charger must be used with the distribution side that with 2P-40A breaker

50
User Manual

protector.

The EV charger must keep away from firework, dusty and corrosive environment.

The EV charger input high voltage current, please keep personal safety.

If the EV charger break down, it would happen electric shock even death.

The E-stop switch can be pressed to cut power.

Don’t cut the breaker or press the E-stop switch when the EV charger running

normally.

The device can’t be disassembly when it is running.

Contact

Zhangjiagang uchen new energy technology co., Ltd

Add:No 999, Yongjin Road,Miaoqiao,Tangqiao Town,Zhangjiagang

City,Jiangsu Province,China.

Tel:86-158-5164-5966

Email:[email protected]

51