WE3 Series of Premium - Efficiency

Three - phase Asynchronous Motor

www.wolong.com/en
www.atb-motors.com
WE.18-10.EN
2
Introduction
Cast iron specification

Sincerity, Harmony and Creativity

Who are we? And what can we offer?

Established in 1984, Wolong Electric Group Co., Ltd was listed on the Shanghai Stock Exchange in June 2002. The Wolong Group
currently has 55 Subsidiaries, more than 18.500 staff, assets of 3.2 billion and an annual revenue of 4.5 billion USD in 2016. The
company is mainly focused on three product chains: Motor and Drives, Transformers and Power Supply.

The history of the ATB Group (Antriebs Technik Bauknecht), with a shareholding of 100 % by Wolong, dates back more than 90
years. With 12 manufacturing bases and more than 3.000 staff in Europe the ATB group includes brands such as Brook Cromp-
ton, Laurence Scott, Morley and Schorch, Other brands within the Wolong group are CNE, OLI and SIR.

Today, the Wolong Electric Group ranks amongst the leading global companies, offering more than 130 years of experience and
expertise.

The product portfolio covers a de range of rating from a few Watts to 130 MWatt of motors and drives, generators, power supply
batteries, electric transmission and transformation equipment and other related products. These can be standard solutions,
customised solutions and design-to-order solutions including complete drive systems for a wide range of applications in low
and high volumes. Our products are widely used in home appliances such as air conditioners, washing machines, kitchen and
garden tools -and also in standard and heavy duty industrial applications such as Oil and Gas, Power Generation, Mining, Ma-
rine, Railway, Electrical Vehicles and many others.

Cast iron specification

Specification

Standard product Option

Frame size 80-355

Enclosure IP55 IP56, IP65

Mounting option Foot (B3), Flange (B5), Face (B14) Foot & Flange (B35), Foot & Face (B34)

Terminal box position Top Right hand side, left hand side

Voltage 400, 380 (V) 500, 690, 415, 440, 460, 480 (V)

Frequency 50 Hz 60 Hz

Cooling IC411 IC410, IC418

Bearing location Drive end Non drive end

Lubrication 80 - 180 double-shielded bearings Regreasing facility

200-355 regreasing facility

Insulation class F class H or Nano Insulation (Pg 14)

Temperature rise class B class F

Paint colour on request

Fan cover Steel

Thermal protection PTC, PTO, PT100

Anti condensation heaters 100 - 355

Drain holes 80 - 355

Inverter Duty (with derate) Variable Torque 10:1

Constant Torque: 2:1 Alternative speed range

Ambient temperature -15˚C to + 40˚C

The above specification and options give a brief summary of features available for the WE3 cast iron range.
For a full listing of optional features, please contact Wolong sales.
General
Quality assurance

3
CE labels
Standards and regulations

Quality assurance CE label


The entire order realisation process for electrical machines, The motors bear the CE label pursuant to the Low Voltage
from quotation to delivery including the integration of our Directive 2014/35/EC or the ErP Directive 2009/125/EC. On
suppliers, is based on a generally accepted quality assurance 29/12/2009, the Machinery Directive 2006/42/EC came into force
system pursuant to ISO 9001, which is constantly monitored which clearly exempts induction motors. The EMC Directive
and undergoes further development. 2014/30/EC rates induction motors as benign equipment and
The designs, technical data and illustrations contained in this exempts them explicitly from its scope.
documentation are subject to change. The motors of this technical list are therefore now only subject
They are only binding upon written confirmation. to the Low Voltage Directive.

Standards, codes, regulations and specifications


The motors conform to the relevant standards and regulations,
including without limitation the following:

Title IEC DIN/EN GB standard

Rotating electrical machines


IEC 60034-1 DIN EN 60034-1 GB 755
Rating and performance
Determination of losses and efficiency IEC 60034-2-1 DIN EN 60034-2-1 GB/T1032
IP degrees of protection IEC 60034-5 DIN EN 60034-5 GB/T 4942.1
Methods of cooling (IC code) IEC 60034-6 DIN EN 60034-6 GB/T 1993
Types of construction (IM code) IEC 60034-7 DIN EN 60034-7 GB/T 997
Terminal markings and direction of rotation IEC 60034-8 DIN EN 60034-8 GB 1971
Noise limits IEC 60034-9 DIN EN 60034-9 GB 10069.3
Built-in thermal protection; rules for protection IEC 60034-11 DIN EN 60034-11 GB/T 13002

Starting performance of single-speed three-phase cage induction motors,


IEC 60034-12 DIN EN 60034-12 GB/T 22210
excluding multi-speed ­motors, for voltages up to and including 690 V/50 Hz
Mechanical vibration of certain machines with shaft heights of 56 mm and above IEC 60034-14 DIN EN 60034-14 GB10068
Rotating electrical machines - Part 25: Guidance for the design and performance
IEC 60034-25 DIN EN 60034-25
of cage induction motors designed for converter supply
Efficiency classes of three-phase squirrel cage motors IEC 60034-30-1 DIN EN 60034-30-1 GB18613
IEC standard voltages IEC 60038 DIN IEC 60038
Three-phase motors for general use with standardized dimensions and outputs IEC 60072 1) DIN EN 50347 GB/T 4772.1

1)
IEC 60072 only provides for dimensions but does not define any output classifications.
(tolerances acc. to EN 50347)
Technical explanations
Three-phase alternating current, rated power

4
Rated-load torque, speed
Connection

Three-phase alternating current Speed-torque characteristic


The term three-phase alternating current is used if the exist-
ing three-phase system carries three individual alternating
voltages that have identical values, but show a 120-degree
phase shift. The three connections of the three-phase system
are called L1, L2 and L3.

Rated power
The rated power is supplied at the motor’s shaft end:
PN = !w3 3 UN 3 IN x cos w 3 h [W]
or
PN = !w3 3 UN 3 IN 3 cos w 3 h 3 10–3 [kW]
UN = rated voltage at the motor [V]
IN = rated current [A]
cos w = power factor
Connection
h = efficiency
Basically, there are two different ways to connect the motor’s
The same formulae, but without the concatenation factor !w
3, three phases.
can be used for single-phase motors.
Star connection
Rated-load torque If the U 2, V 2 and W 2 winding ends are connected to each other,
the star connection with a neutral point is formed.
The rated-load torque is determined as follows Rated voltage UN, i.e. total voltage at 2 of the 3 phases that are
PN shifted by 120 degrees each; rated current IN, i.e. current at
MN = 9550 × [Nm]
nN the individual system connections, which means
UN = !w 3 × Uph
PN = rated power [kW] IN = Iph
nN = rated speed [min–1]
The SI unit is Newton meter.
1
1 Nm = kgm
9.81

Speed
Delta connection
The no-load speed corresponds to the synchronous speed If the end of each phase winding is connected to the start of
reduced by the slip. The motor’s synchronous speed is deter- the next phase winding, the delta connection is formed. Such a
mined as follows connection does not include a neutral point.
f × 60 Rated voltage UN, i.e. voltage at 2 of the 3 system connections.
nS = [min–1] Rated current IN, i.e. total current at 2 of the 3 phases that are
p
shifted by 120 degrees each, which means
f = frequency [Hz] UN = Uph
p = number of pole pairs IN = !w
3 3 Iph

The synchronous speed is reduced to the rated speed by the


slip s that is required for power output (refer to technical data).
nN = nS × 3 (1 – s) [min–1]
nS = synchronous speed [min–1]

In general, three-phase motors with a power of up to 4 kW


are provided with direct-on-line starting, while three-phase
motors with a power from 5.5 kW upwards are provided with
star-delta starting.
Technical explanations

5
Degree of protection
Condensate drainage holes

Degree of protection according to IEC 60034-5

Degree of
Scope of protection (test conditions) Motor design Explanation
protection 1)
Protection against electric shock and the Protection against the
ingress of solid foreign bodies ­ingress of water
IP 54 Full protection against contact with and Water sprayed onto the Standard design The motors can be installed in a dusty or
approach to live parts, as well as con- machine from all directions damp environment. Such conditions are also
tact with moving parts inside the housing. may not have any detrimen- permissible for the insulation of the stator
Protection against detrimental dust de- tal effects. winding. Motors that are exposed to moder-
posits. The ingress of dust is not com- ate environmental influences during proper
pletely blocked, however, dust ingress is storage or installation in premises used for
IP 55 2) reduced to ensure that satisfactory ma- A jet of water from a noz- industrial purposes do not require any spe-
chine operation will not be affected. zle, pointed at the machine cial measures. Standard N 04 paint provides
from all directions, has no sufficient protection for the impact ­occurring
detrimental effects. ­under such conditions.
In case of extreme climatic conditions, an
IP 55 degree of protection is required with
additional measures, e.g. in case of per-
Special design on manent moisture (more than 80  % relative
customer’s request humidity), damp tropical climate, aggressive
industrial atmosphere, unprotected outdoor
installation with the risk of stormy rain, and
IP 56 Splashes of water caused in coastal climate.
by heavy seas or strong
jets do not penetrate the
housing in detrimental
­quantities.
IP 65 Full protection against contact with and A jet of water from a noz-
approach to live parts, as well as con- zle, pointed at the machine
tact with moving parts inside the hous- from all directions, has no
ing. Protection against the ingress of dust detrimental effects.
(dust-tight).

For all types of construction with the shaft end in a downward position, the design “with drip roof” is recommended, in order
to prevent the ingress of water at the second non-drive shaft end. For all types of construction with the shaft end in an upward
position, a suitable cover, which prevents the dropping of small parts onto the fan cowl, is a prerequisite. This does not apply
when the motor is attached to a driven machine, which then provides cover. However, the cooling air flow may not be affected by
such a cover. Motors that are installed out of doors must be protected against intensive solar radiation (for IM V1 with drip roof).

Condensate drainage holes


Motors up to and including frame size 355 are not provided Note:
with condensate drain holes. In addition to the “normal use” as specified in the operating
They will be installed only at special request, which has to be and maintenance instructions, motors with condensate drain
explicitly specified in the order. holes, which owing to the motor’s degree of protection are
The position of these holes depends on the motor’s type of sealed tightly with a screw, must be drained at reasona-
construction and mounting position. ble intervals (in accordance with the degree of condensate
Condensate drain holes are positioned at the lowest point (in formation).
the end shield or motor housing) depending on the order.
Technical explanations

6 Mounting arrangements

Mounting arrangements

The most common mounting arrangements are shown in the IM B3 in IM B6, IM B7, IM B8, IM V5 or IM V6,
following table. The dimensional drawings show the range of IM B5 in IM V1 or IM V3,
frame sizes for which the individual types of construction are IM B14 in IM V18 or IM V19.
available. Further types of construction are available on request. For motors up to frame size 315 (standard design without con-
The basic type of construction is specified on the rating plate densate drain). Owing to the fact that the terminal boxes are
according to code I, IEC 60034-7. Standard motors, i.e. frame rotatable by 90 degrees, connection of the motors to the supply
sizes 80 – 355, which are ordered as the basic types of construc- system is provided for in all types of construction.
tion (universal types of construction) IM B3, IM B5 or IM B14,
can also be operated in the following non-standard mounting
positions1) :

Code I (Code II) Code I (Code II)


Foot-mounting
­motors
All frame sizes IM B3 (IM 1001) IM B8 (IM 1071)
–– Shaft in a horizontal po- –– Shaft in a horizontal po-
sition sition
–– Feet on the floor –– Feet upward
IM B6 (IM 1051) IM V5 (IM 1011)
–– Shaft in a horizontal po- –– Shaft in a vertical down-
sition ward position
–– Feet on the wall and left –– Feet on the wall
when looking at the shaft
end
IM B7 (IM 1061) IM V6 (IM 1031)
–– Shaft in a horizontal po- –– Shaft in a vertical upward
sition position
–– Feet on the wall and right –– Feet on the wall
when looking at the shaft
end
Flange-mounting IM B5 (IM 3001) IM B35 (IM 2001)
motors, FF flange –– Shaft in a horizontal po- –– Shaft in a horizontal po-
with through-holes sition sition
All frame sizes –– Feet on the floor
­former designation
acc. to DIN: A-flange IM V1 (IM 3011) IM V15 (IM 2011)
–– Shaft in a vertical down- –– Shaft in a vertical down-
ward position ward position
–– Feet on the wall

IM V3 (IM 3031) IM V35 (IM 2031)


–– Shaft in a vertical upward –– Shaft in a vertical upward
position position
–– Feet on the wall

limited bearing load with vertical installation


Technical explanations

Types of construction 7
Mounting arrangements

Code I (Code II) Code I (Code II)


Flange-mounting IM B14 (IM 3601) IM B34 (IM 2101)
motors, FT flange –– Shaft in a horizontal po- –– Shaft in a horizontal po-
with tapped holes sition sition
up to frame size –– Feet on the floor
160; former desig-
nation acc. to DIN:
IM V18 (IM 3611) IM V17 (IM 2111)
–– Shaft in a vertical down- –– Shaft in a vertical down-
C-flange
ward position ward position
–– Feet on the wall

IM V3 (IM 3031) IM V37 (IM 2131)


–– Shaft in a vertical upward –– Shaft in a vertical upward
position position
–– Feet on the wall

Motors without IM B9 (IM 9101) IM B15 (IM 1201)


end shield and –– Threaded tension bolts –– Feet and threaded tension
rolling-­contact –– Shaft in a horizontal po- bolts
bearing at the sition –– Shaft in a horizontal po-
drive end sition
Technical explanations
Shaft ends, Key and Keyway

8
Balancing, mechanical running smoothness
Coupling drive

Shaft ends Balancing


The shaft ends are cylindrical and both their design, size and On all motors, the rotors are dynamically balanced with a half
performance classification conform to IEC 50347. Motors from key at operating speeds according to DIN ISO 21940-32:2012.
frame size 80 upwards are equipped with shaft ends that have In accordance with this standard, letter symbols additionally
internal threads conforming to DIN 332-2 for the fitting of belt specify the type of key and keyway balancing on the rating
pulleys and couplings. The design of the featherkeys conforms plate or the face of the drive shaft. (H – half key balancing,
to DIN 6885-1; the keys are always included in the motor de- F – full key balancing).
livery packages. The use of high-quality, rolling-contact bearings as well as
On customer request, motors are delivered with a second free compliance with the fit tolerances ensure reliable running
shaft end. smoothness and vibration severity grade. The catalogued
motors conform with vibration severity grade “A” according
Key & Keyway to IEC 60034-14.
It must be ensured that transmission elements (belt pulleys,
The key and keyway correspond to form A according to
couplings, gear wheels, etc.) without slots are dynamically
DIN 6885-1. The tolerances of the featherkey and the feath-
balanced at the intended speed.
erkey way are in accordance with IEC 50347.
Furthermore, it is important that the hub length corresponds
Frame sizes 80 – 355 dimensions of the key and keyway and
to the length of the key, as, failing this, additional residual
position in the shaft end: central
unbalances would affect the motor’s vibration.
According to the regulation IEC 60034, rotors are designed for
Frame
size
Length an overspeed test speed equal to 1.2 times the highest safer
Minimum lengths acc. to rated speed.
Width Height Standard
DIN EN 50347
mm mm mm mm
Vibration
80 6 6 32 32
90 8 7 40 40 In case of special requirements, vibration severity grade “B”
100 + 112 8 7 50 50 is available on a surcharge basis:
132 10 8 70 70
The subsequent vibration severity limits are valid for motors
160 12 8 100 90
running at no load in an uncoupled mode with free suspension.
180 14 9 100 100
200 16 10 100 100
Vibration Vibration velocity in mm/s
225/2 16 10 100 100
severity Speed range Effective height to shaft centre value
225/4 18 11 125 125
grade in mm
250/2 18 11 125 125
min–1 ≤132 160 – 280  280>
250/4 18 11 125 125
280/2 18 11 125 125 A 120 to 3600 1.6 2.2 2.8
280/4 20 12 125 125 B 120 to 3600 0.7 1.1 1.8
315/2 18 11 125 125 According to IEC 60034-14 (VDE 0530, part 14)
315/4 22 14 140 140
355/2 20 12 125 125
Coupling
355/4 25 14 140 140
Torsionally flexible coupling is permitted for all motors. How-
ever, it must be taken into consideration that torsionally flexible
couplings also require very precise alignment of the machines
to be coupled, in order to exclude vibrations during running to
the greatest possible extent and to ensure that the bearings’ life
is not reduced by non-permissible loads. The coupling of 2-pole
motors (with synchronous speeds of 3000 min-1 at 50 Hz and
3600 min-1 at 60 Hz) must be carried out with the utmost care
and precision. It is essential to ensure that the coupling half
on the motor end is dynamically balanced on a plain mandrel.

Fitting and extraction of belt pulleys and couplings


Belt pulleys and couplings must be fitted and extracted using
special tools.
Mechanical construction

Cooling method 9
Cooling method
The motors are fitted with fans made of plastic or metal that provide cooling regardless of the direction of rotation of the motor.
The built-in fan moves the cooling air from the non-drive end to the drive end. For this reason, it is essential that the openings
of the fan cowl ensure free air inflow. Correct cooling depends on observing a minimum space between the fan cowl and any
existing wall.
The cooling methods for electrical machines are stated in code according to IEC 60034-6. The code consists of the letters
IC (International Cooling) and a three-digit number.

• IC 410: Totally enclosed non-ventilated: cooling without using a fan, by natural ventilation and radiation on the enclosed
motor surface.
• IC 411: Totally enclosed fan-cooled: cooling air is blown over the totally enclosed motor surface by a fan mounted on the
shaft.
• IC 418: External surface-cooled: Cooling air is blown over the totally enclosed motor surface. The motor is positioned in
the external air flow and can be self-ventilated or also non-ventilated.

The standard featured in this list are classified in the cooling method IC 411 (surface-cooled)
Due consideration must be given to heat incidence and heat radiation (e.g. solar radiation, media temperatures, ...).
Mechanical construction

10 Bearings

Bearings
The motors are equipped with rolling-contact bearings on the drive end and the non-drive end. The bearings in motors up to and
including frame size 180 are permanently lubricated. Motors of frame size 200 have a regreasable bearing. Other on request.
These motors are fitted with an additional plate stating details about the specific lubricant, the quantity required and the
greasing intervals.

Bearing type (bearing selection can be changed according to customer needs)

Frame size Number of poles Drive end Non drive end

80 2~6 6204ZZ 6204ZZ


90 2~6 6205ZZ 6203ZZ
100 2~6 6206ZZ 6205ZZ
112 2~6 6206ZZ 6206ZZ
132 2~6 6208ZZ 6305ZZ
160 2~6 6309ZZ 6307ZZ
180 2~6 6310ZZ 6308ZZ
200 2 6312 6212
200 4~6 6312 6212
225 2 6312 6312
225 4~6 6313 6312
250 2 6313 6313
250 4~6 6314 6313
280 2 6314 6314
280 4~6 6317 6314
315 2 6317 6317
315 4~6 6319 6319
355 2 6319 6319
355 4~6 6322 6322
Mechanical construction

11
Lubrication
Permissible forces at the shaft end

Lubrication Permissible forces at the shaft end


Standard motors are lubricated for life. In the case of increased The specified values are valid for the bearings and drive end
load and extreme temperatures, special greases are available. shaft ends contained in this list, taking a calculated life of L10h
= 20000 h as the basis. They are permitted for both horizontal
and vertical shafts. The table contains data concerning the per-
missible radial force FR at a distance x from the shaft shoulder.

Permissible radial force


Frame sizes 80-355

Frame Radical Force F0 (N)

2P 4P 6P

FR x=0 FR x=max FR x=0 FR x=max FR x=0 FR x=max

WE3-80 485 400 625 515 735 605


WE3-90 725 605 920 775 10990 910
WE3-100 1010 830 1270 1040 1520 1240
WE3-112 1030 840 1310 1060 1550 1250
WE3-132 1490 1180 1940 1530 2260 1780
WE3-160 1540 1210 2040 1590 2330 1820
WE3-180 2000 1550 2350 1950 2800 2250
WE3-200 2550 2100 3350 2750 3900 3200
WE3-225 3050 2550 3750 2950 4550 3600
WE3-250 3650 2950 4400 3600 5350 4350
WE3-280 3350 2800 8700 7200 10800 8900
WE3-315 3950 3350 9900 8100 12100 9900
WE3-355 4250 3750 10300 9000 13000 11000
Electrical design

12
Power
Tolerances

Power Tolerances
The rated power and operating values specified in the selec- According to DIN EN 60034-1, the following tolerances apply
tion tables are applicable to the S1 service type as defined to the electrical values specified in the rating tables:
by IEC 60034-1 at a rated frequency of 50 Hz, rated voltage,
a coolant temperature (KT) of max. 40 °C and a site altitude Efficiency h:
of up to 1000 m above sea level. The motors can also be
used at coolant temperatures from 40 °C to max. 60 °C, or PN ≤ 150kW –15 % (1 – h)
a site altitude of more than 1000 m above sea level. In these PN > 150 kW –10 % (1 – h)
cases, the rated power specified in the selection tables
must be reduced in accordance with the below chart and/ 1 – cos w
or a larger motor type or higher temperature class must Power factor cos w: –
6
be selected. Motors for higher coolant temperatures are
available on request.

Slip s at nominal load and rated-load operating temper-


ature:

> 1 kW ± 20 % of the guaranteed slip


< 1 kW ± 30 % of the guaranteed slip

Locked-rotor torque: –15 %


Coolant temp. in °C Breakdown torque: –10 %
Locked-rotor current: +20 %

Rated current:
The rating tables specify the rated currents only for a rated
voltage of 400 V. In the case of any other voltages, the rated
currents change in reverse proportion to the voltages:
U IN
=
UN I
From this, it follows:
Site altitude above sea level U×I
IN =
UN

Occasional excess current


According to DIN EN 60034-1, motors with a rated power
of up to 315 kW, running at rated-load operating temper-
ature, can withstand excess current of 1.5 times the rated
current for a period of 2 minutes without their lifetimes
being adversely affected.
Electrical design

Efficiency 13
Efficiency according to IEC 60034-30-1
2-pole
PN (kW) 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200-375
IE1 50 Hz 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.8 94.0
(η %) 60 Hz 74.0 78.5 81.0 81.5 84.5 1) 86.0 87.5 87.5 88.5 89.5 89.5 90.2 91.5 91.7 92.4 93.0 93.0 93.0 94.1 2) 94.1 3) 94.1
IE2 50 Hz 77.4 79.6 81.3 83.2 84.6 85.8 87.0 88.1 89.4 90.3 90.9 91.3 92.0 92.5 92.9 93.2 93.8 94.1 94.3 94.6 94.8 95.0
(η %) 60 Hz 75.5 82.5 84.0 85.5 87.5 1) 88.5 89.5 90.2 90.2 91.0 91.0 91.7 92.4 93.0 93.0 93.6 94.5 94.5 95.0 2) 95.4 3) 95.4
IE3 50 Hz 80.7 82.7 84.2 85.9 87.1 88.1 89.2 90.1 91.2 91.9 92.4 92.7 93.3 93.7 94.0 94.3 94.7 95.0 95.2 95.4 95.6 95.8
(η %) 60 Hz 77.0 84.0 85.5 86.5 88.5 1) 89.5 90.2 91.0 91.0 91.7 91.7 92.4 93.0 93.6 93.6 94.1 95.0 95.0 95.4 2) 95.8 3) 95.8
IE4 50 Hz 83.5 85.2 86.5 88.0 89.1 90.0 90.9 91.7 92.6 93.3 93.7 94.0 94.5 94.8 95.0 95.3 95.6 95.8 96.0 96.2 96.3 96.5
(η %) 60 Hz 82.5 85.5 86.5 88.5 89.5 1) 90.2 91.7 92.4 92.4 93.0 93.0 93.6 94.1 94.5 94.5 95.0 95.4 95.4 95.8 2) 96.2 3) 96.2

4-pole
PN (kW) 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200-375
IE1 50 Hz 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.8 94.0
(η %) 60 Hz 77.0 79.0 81.5 83.0 85.0 1) 87.0 87.5 88.5 89.5 90.5 91.0 91.7 92.4 93.0 93.0 93.2 93.2 93.5 94.5 2) 94.5 3) 94.5
IE2 50 Hz 79.6 81.4 82.8 84.3 85.5 86.6 87.7 88.7 89.8 90.6 91.2 91.6 92.3 92.7 93.1 93.5 94.0 94.2 94.5 94.7 94.9 95.1
(η %) 60 Hz 78.0 84.0 84.0 87.5 87.5 1) 89.5 89.5 91.0 91.0 92.4 92.4 93.0 93.0 93.6 94.1 94.5 94.5 95.0 95.0 2) 95.0 3) 95.4
IE3 50 Hz 82.5 84.1 85.3 86.7 87.7 88.6 89.6 90.4 91.4 92.1 92.6 93.0 93.6 93.9 94.2 94.6 95.0 95.2 95.4 95.6 95.8 96.0
(η %) 60 Hz 83.5 86.5 86.5 89.5 89.5 1) 91.7 91.7 92.4 93.0 93.6 93.6 94.1 94.5 95.0 95.4 95.4 95.4 95.8 96.2 2) 96.2 3) 96.2
IE4 50 Hz 85.7 87.2 88.2 89.5 90.4 91.1 91.9 92.6 93.3 93.9 94.2 94.5 94.9 95.2 95.4 95.7 96.0 96.1 96.3 96.4 96.6 96.7
(η %) 60 Hz 85.5 87.5 88.5 91.0 91.0 1) 92.4 92.4 93.6 94.1 94.5 94.5 95.0 95.4 95.4 95.8 96.2 96.2 96.2 96.5 2) 96.5 3) 96.8

6-pole
PN (kW) 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200-375
IE1 50 Hz 70.0 72.9 75.2 77.7 79.7 81.4 83.1 84.7 86.4 87.7 88.6 89.2 90.2 90.8 91.4 91.9 92.6 92.9 93.3 93.5 93.8 94.0
(η %) 60 Hz 72.0 75.0 77.0 78.5 83.5 1) 85.0 86.0 89.0 89.5 90.2 91.0 91.7 91.7 91.7 92.1 93.0 93.0 94.1 94.1 2) 94.1 3) 94.1
IE2 50 Hz 75.9 78.1 79.8 81.8 83.3 84.6 86.0 87.2 88.7 89.7 90.4 90.9 91.7 92.2 92.7 93.1 93.7 94.0 94.3 94.6 94.8 95.0
(η %) 60 Hz 73.0 85.5 86.5 87.5 87.5 1) 89.5 89.5 90.2 90.2 91.7 91.7 93.0 93.0 93.6 93.6 94.1 94.1 95.0 95.0 2) 95.0 3) 95.0
IE3 50 Hz 78.9 81.0 82.5 84.3 85.6 86.8 88.0 89.1 90.3 91.2 91.7 92.2 92.9 93.3 93.7 94.1 94.6 94.9 95.1 95.4 95.6 95.8
(η %) 60 Hz 82.5 87.5 88.5 89.5 89.5 1) 91.0 91.0 91.7 91.7 93.0 93.0 94.1 94.1 94.5 94.5 95.0 95.0 95.8 95.8 2) 95.8 3) 95.8
IE4 50 Hz 82.7 84.5 85.9 87.4 88.6 89.5 90.5 91.3 92.3 92.9 93.4 93.7 94.2 94.5 94.8 95.1 95.4 95.6 95.8 96.0 96.2 96.5
(η %) 60 Hz 84.0 88.5 89.5 90.2 90.2 1) 91.7 92.4 93.0 93.0 94.1 94.1 95.0 95.0 95.4 95.4 95.8 95.8 96.2 96.2 2) 96.2 3) 96.5
1)
at 3.7 kW
2)
at 150 kW
3)
at 185 kW
Electrical design
Temperature class, insulation

14
Direction of rotation
Types of service

Temperature classes Types of service


According to DIN EN 60034, insulating materials, including Types of service Designation Required data
impregnants, are classified in temperature classes, to which according to
exactly defined temperature values are assigned. DIN EN 60034-1
S1 Continuous running duty
(constant load)
S2 Short-term duty Operating duration
(constant load)
S3 Periodic duty (constant Cyclic duration factor
load/standstill)
S4 Intermittent period- Cyclic duration factor
ic duty with starting Mass moment of inertia
(starting/constant load/of the motor
40 40 40
standstill) Mass moment of inertia
of the loading machine
S5 Intermittent periodic Cyclic duration factor
duty with electric brak- Mass moment of inertia
TRL Temperature rise limit (temperature rise) in K (mean value ing (starting/constant of the motor
in Kelvin) load/braking/standstill) Mass moment of inertia
CT Coolant temperature
of the loading machine
MPT Maximum allowable permanent temperature in °C (for the hottest
point of the winding) S6 Continuous-operation Cyclic duration factor
periodic duty (constant
Insulation load/no load)
S7 Continuous-operation Mass moment of inertia
All motors are designed in accordance with temperature class periodic duty with elec- of the motor
155 (F). At rated power and in direct on-line operation, motor tric braking (starting/ Mass moment of inertia
utilization corresponds to temperature class 130 (B). constant load/braking/ of the loading machine
The used insulating material systems largely protect the wind- standstill)
ing against the influence of gases, vapours, dust and oil. They S8 Continuous-operation Mass moment of inertia
withstand normal climate loads according to IEC 60721-3 and periodic duty with load/ of the motor
are tropic-proof. speed changes Mass moment of inertia
of the loading machine
Temperature class 155 (F) Load/speed/cyclic dura-
tion factor
As the standard design motors specified in this list are utilized
S9 Duty with non-periodic on request
in accordance with temperature class 130 (B), it is possible to load and speed varia-
either increase the rated power for frame size 80 to 355 motors tions
in continuous operation with a coolant temperature of 40 °C by S10 Duty with discrete con- Load/application time
10 %, or to raise the coolant temperature from 40 °C to 60 °C stant loads Relative thermal life
in operation at rated power. expectancy
Motors for higher coolant temperatures are available on re-
quest. Recommended values for
Operating duration: 10, 30, 60 and 90 minutes
Direction of rotation Cyclic duration factor: 15; 25; 40 and 60 %
Cycle time: 10 minutes
Motors can be operated in both directions of rotation. If the line
For the S2-S8 types of services, the starting counter-torque
phases are connected to the U1, V1, W1 motor terminals in a L1,
must be specified.
L2, L3 order, the direction of rotation is clockwise when looking
at the drive end, in accordance with IEC 60034-8. The direction
of rotation can be reversed by exchanging any two phases.
Electrical design
Thermal motor protection

15
Space heater
Starting frequency

Thermal motor protection Space heater


The thermal motor protection of the stator windings should To reduce condensation inside the motor, motors can be
be chosen to ideally suit the operating conditions. In addition equipped with space heaters which are available on request
to motor protecting switches with thermally delayed overcur- at a surcharge. For the normal supply voltage, refer to the
rent protection, motors can also be protected by thermistor ­table. Other supply voltages are available on request. The space
detectors, integrated into the winding. "Thermal motor pro- heater must not be on during operation.
tection" (TMS) provides increased protection by monitoring the Alternatively, it is possible to connect a voltage of approx.
temperature at a critical point in the winding. Thus, conditions 5 – 10% of the motor’s rated voltage to the U1 and V1 termi-
such as reduced cooling or increased ambient temperatures nals (single-phase), in order to provide for sufficient heating
are detected, which a bimetal trip element does not register. of the stator winding.
In special cases, such as reversing duty, frequent operation
or conversion, the bimetal trip element cannot be adjusted to Space heater overview
provide sufficient protection. In such cases, it is essential to
use thermal motor protection. Usually, PTC thermistors are Frame size Supply voltage Heating output
employed as temperature detectors, however in special cases,
V W
NTC thermistors are used.
100 230 30
In order to protect all the motor windings, each winding incor-
112 230 30
porates one thermistor per phase.
132 230 40
Motors protected exclusively by PTC (so-called motor protec-
160 230 40
tion exclusively by PTC thermistors) are available on request.
180 230 50
The control unit which is required in addition to the PTC dis-
200 230 50
connects the motor winding from the supply when the nominal
225 230 60
response temperature (NAT) is reached. A maximum of 6 PTC
thermistors can be connected to one control unit. 250 230 60
280 230 60
315 230 2 x 80
355 230 2 x 110

Starting frequency
The number of starts/h specified in the following table are
permissible without closer checks on the following conditions.
Load moment of inertia # rotor moment of inertia; counter-­
torque increasing with the square of the speed to nominal
torque; starts at regular intervals.

Shaft height Permissible number of starts/h


2-pole 4-pole 6-pole
180 15 30 50
200 + 225 8 15 30
250 – 315 4 8 12
Three-phase squirrel-cage a.c motors

16
Product information requirements according to Regulation 640/2009
Nameplate

Nameplate

Super-high efficiency
three-phase induction motor

The technical data according to Annex 1 (2) of Regulation 1 Type 13 Protection class
640/2009 are numbered through from point 1 to 20 and 2 Rated voltage 14 Insulation class
are listed below with reference to the nameplate and the 3 Rated current 15 Noise
tables with the electrical data in this chapter. 4 Rated power 16 Manufacturing number
5 Efficiency 17 Front bearing type
6 The service factor 18 Rear bearing type
7 Duty type 19 Date of production
8 Rated frequency 20 QR code
9 Power factor
10 Rated speed
11 Weight
12 Connection
Three-phase squirrel-cage a.c. motors

Type designation 17
Type designation, frame sizes 80-355
The full type designation is stated in the rating tables.
It is structured as follows:

WE3 - 160 L - 2 - х

Environmental condition code


(Needed when there are special design requirements)
F1-Indoor anti-medium corrosion type
F2-Indoor anti-strong corrosion type
WF1-Outdoor anti-medium corrosion type
WF2-Outdoor anti-strong corrosion type
TH-Humid tropics
G-Highland
Poles
Length of FS e.g. S means short FS, L means long FS
Frame Size
WE3 Series three-phase asynchronous motor, IE3 efficiency.

Name of the manufacturer

Nameplate
WE3 Series
Three - phase Asynchronous Motor

18 Technical parameters 2 & 4 poles 50Hz

Technical parameters 2 pole 50Hz

Rated Rated Rated Efficiency Power factor


Rated Rated Starting Starting Breakdown Moment
current current current Weight Noise Torque
Output Speed 50% 75% 100% 50% 75% 100% Torque Current Torque of inertia
Type at 380 V at 400 V at 415 V
Load Load Load Load Load Load
PN IN IN IN n  Cosφ mM MN
Tst/TN Ist/IN TM/TN dB(A) (kgm2)
(kW) (A) (A) (A) (min-1) (%) kg (Nm)
WE3-80M1-2 0.75 1.72 1.64 1.58 2860 79.3 81.1 80.7 0.73 0.79 0.82 2.3 7.0 2.3 12 62 0.00099 2.50
WE3-80M2-2 1.1 2.43 2.31 2.23 2880 79.6 82.5 82.7 0.73 0.76 0.83 2.2 7.3 2.3 12.5 62 0.00129 3.65
WE3-90S-2 1.5 3.22 3.06 2.95 2885 84.1 84.9 84.2 0.74 0.81 0.84 2.2 7.6 2.3 22.5 67 0.00137 4.97
WE3-90L-2 2.2 4.58 4.35 4.19 2870 85.8 86.5 85.9 0.74 0.82 0.85 2.2 7.6 2.3 24 67 0.00160 7.32
WE3-100L-2 3 6.02 5.71 5.51 2900 86.2 87.4 87.1 0.79 0.84 0.87 2.2 7.8 2.3 34 74 0.00531 9.88
WE3-112M-2 4 7.84 7.45 7.18 2900 88.7 89.2 88.1 0.78 0.85 0.88 2.2 8.3 2.3 41 77 0.00690 13.2
WE3-132S1-2 5.5 10.6 10.1 9.75 2920 88.9 89.6 89.2 0.78 0.85 0.88 2.0 8.3 2.3 60 79 0.01447 18.0
WE3-132S2-2 7.5 14.4 13.7 13.2 2905 89.9 90.6 90.1 0.79 0.85 0.88 2.0 7.9 2.3 63 79 0.01842 24.7
WE3-132L-2 9.2 17.5 16.7 16.1 2905 89.9 91.0 90.6 0.79 0.85 0.88 2.0 7.9 2.3 75 79 0.02345 30.2
WE3-160M1-2 11 20.6 19.6 18.9 2940 89.9 91.1 91.2 0.78 0.86 0.89 2.0 8.1 2.3 110 81 0.04558 35.7
WE3-160M2-2 15 27.9 26.5 25.5 2930 91.3 92.1 91.9 0.79 0.86 0.89 2.0 8.1 2.3 118 81 0.05260 48.9
WE3-160L-2 18.5 34.2 32.5 31.3 2930 92.2 92.7 92.4 0.81 0.87 0.89 2.0 8.2 2.3 132 81 0.06312 60.3
WE3-180M-2 22 40.5 38.5 37.1 2945 92.1 92.9 92.7 0.81 0.87 0.89 2.0 8.2 2.3 158 83 0.09162 71.3
WE3-200L1-2 30 54.9 52.1 50.3 2970 91.3 92.9 93.3 0.80 0.87 0.89 2.0 7.6 2.3 256 84 0.18377 96.5
WE3-200L2-2 37 67.4 64.0 61.7 2970 91.8 93.3 93.7 0.78 0.86 0.89 2.0 7.6 2.3 260 84 0.21675 119
WE3-225M-2 45 80.8 76.8 74.0 2970 92.4 94.0 94.0 0.83 0.88 0.90 2.0 7.7 2.3 330 86 0.35520 145
WE3-250M-2 55 98.5 93.5 90.2 2970 93.0 94.3 94.3 0.78 0.86 0.90 2.0 7.7 2.3 395 89 0.44658 177
WE3-280S-2 75 134 127 122 2980 93.5 94.7 94.7 0.83 0.87 0.90 1.8 7.1 2.3 571 91 0.81913 241
WE3-280M-2 90 160 152 146 2980 93.3 95.0 95.0 0.80 0.87 0.90 1.8 7.1 2.3 657 91 1.02392 289
WE3-315S-2 110 195 185 179 2985 93.8 95.2 95.2 0.86 0.89 0.90 1.8 7.1 2.3 910 92 1.39782 353
WE3-315M-2 132 234 222 214 2985 94.0 95.4 95.4 0.84 0.87 0.90 1.8 7.1 2.3 1230 92 1.54652 423
WE3-315L1-2 160 279 265 256 2985 94.7 95.6 95.6 0.85 0.88 0.91 1.8 7.2 2.3 1345 92 2.02237 513
WE3-315L2-2 185 185 323 307 296 2985 94.6 95.7 95.7 0.86 0.88 0.91 1.8 7.2 2.2 1410 92 2.15685 593
WE3-315L3-2 200 200 349 331 319 2985 95.2 95.8 95.8 0.87 0.89 0.91 1.8 7.2 2.2 1450 92 2.37926 641
WE3-355M1-2 220 384 364 351 2990 95.5 95.8 95.8 0.87 0.89 0.91 1.6 7.2 2.2 1590 100 4.01523 705
WE3-355M2-2 250 436 414 399 2990 95.4 95.8 95.8 0.88 0.89 0.91 1.6 7.2 2.2 1607 100 4.71113 801
WE3-355L1-2 280 488 464 447 2990 94.8 95.8 95.8 0.88 0.89 0.91 1.6 7.2 2.2 1837 100 4.29613 897
WE3-355L2-2 315 549 522 503 2990 95.3 95.8 95.8 0.88 0.89 0.91 1.6 7.2 2.2 1860 100 5.71224 1009
WE3-3551-2 355 355 619 588 567 2990 95.3 95.8 95.8 0.88 0.89 0.91 1.6 7.2 2.2 2085 104 6.47780 1138
WE3-3552-2 375 375 654 621 598 2990 95.3 95.8 95.8 0.88 0.89 0.91 1.6 7.2 2.2 2285 104 6.47780 1202

Technical parameters 4 pole 50Hz

Rated Rated Rated Efficiency Power factor


Rated Rated Starting Starting Breakdown Moment
current current current Weight Noise Torque
Output at 380 V at 415 V Speed 50% 75% 100% 50% 75% 100% Torque Current Torque of inertia
Type at 400 V
Load Load Load Load Load Load
PN IN IN IN n  Cosφ mM MN
Tst/TN Ist/IN TM/TN dB(A) (kgm2)
(kW) (A) (A) (A) (min-1) (%) kg (Nm)
WE3-80M1-4 0.55 1.38 1.31 1.26 1425 77.9 80.8 80.8 0.57 0.68 0.75 2.3 6.6 2.3 14 56 0.00182 3.69
WE3-80M2-4 0.75 1.84 1.75 1.69 1425 79.6 82.4 82.5 0.57 0.69 0.75 2.3 6.6 2.3 15.5 56 0.00234 5.03
WE3-90S-4 1.1 2.61 2.48 2.39 1430 83.2 84.6 84.1 0.56 0.69 0.76 2.3 6.8 2.3 23 59 0.00340 7.35
WE3-90L-4 1.5 3.47 3.30 3.18 1425 84.7 85.8 85.3 0.58 0.70 0.77 2.3 7.0 2.3 26 59 0.00429 10.1
WE3-100L1-4 2.2 4.76 4.52 4.36 1445 84.8 86.8 86.7 0.64 0.75 0.81 2.3 7.6 2.3 35 64 0.01021 14.5
WE3-100L2-4 3 6.34 6.02 5.80 1420 85.7 87.7 87.7 0.65 0.76 0.82 2.3 7.6 2.3 41 64 0.01392 20.2
WE3-112M-4 4 8.37 7.95 7.66 1450 88.5 89.2 88.6 0.69 0.78 0.82 2.2 7.8 2.3 50 65 0.02010 26.3
WE3-132S-4 5.5 11.2 10.7 10.3 1460 89.3 90.0 89.6 0.67 0.77 0.83 2.0 7.9 2.3 70 71 0.03208 36.0
WE3-132M-4 7.5 15.0 14.3 13.7 1445 90.9 91.2 90.4 0.70 0.80 0.84 2.0 7.5 2.3 76.5 71 0.03609 49.6
WE3-132L-4 9.2 18.3 17.4 16.8 1445 91.2 91.7 90.9 0.70 0.80 0.84 2.0 7.5 2.3 85 71 0.04061 60.8
WE3-160M-4 11 21.5 20.4 19.7 1470 90.7 91.6 91.4 0.70 0.80 0.85 2.2 7.7 2.3 121 73 0.08875 71.5
WE3-160L-4 15 28.8 27.3 26.3 1470 92.0 92.5 92.1 0.74 0.82 0.86 2.2 7.8 2.3 129 73 0.10593 97.4
WE3-180M-4 18.5 35.3 33.5 32.3 1475 92.0 92.8 92.6 0.71 0.81 0.86 2.0 7.8 2.3 173 76 0.17329 120
WE3-180L-4 22 41.8 39.7 38.3 1475 92.2 93.0 93.0 0.72 0.82 0.86 2.0 7.8 2.3 184 76 0.19736 142
WE3-200L-4 30 56.6 53.8 51.9 1475 92.7 93.6 93.6 0.76 0.83 0.86 2.0 7.3 2.3 270 76 0.41523 194
WE3-225S-4 37 69.6 66.1 63.7 1480 92.4 93.9 93.9 0.74 0.82 0.86 2.0 7.4 2.3 305 78 0.45833 239
WE3-225M-4 45 84.4 80.2 77.3 1480 92.8 94.2 94.2 0.75 0.82 0.86 2.0 7.4 2.3 335 78 0.52839 290
WE3-250M-4 55 103 97.6 94.1 1480 93.0 94.6 94.6 0.77 0.82 0.86 2.2 7.4 2.3 451 79 0.83961 355
WE3-280S-4 75 136 129 125 1485 93.3 95.0 95.0 0.78 0.85 0.88 2.0 6.9 2.3 598 80 1.46336 484
WE3-280M-4 90 163 155 129 1485 93.6 95.2 95.2 0.76 0.83 0.88 2.0 6.9 2.3 684 80 1.79595 579
WE3-315S-4 110 197 187 180 1490 93.6 95.4 95.4 0.82 0.86 0.89 2.0 7.0 2.2 890 88 2.92524 707
WE3-315M-4 132 236 224 216 1490 94.8 95.6 95.6 0.82 0.87 0.89 2.0 7.0 2.2 1240 88 3.26277 849
WE3-315L1-4 160 285 271 261 1490 95.2 95.8 95.8 0.84 0.86 0.89 2.0 7.1 2.2 1390 88 3.93783 1029
WE3-315L2-4 185 185 329 313 302 1490 95.3 95.3 95.9 0.83 0.86 0.89 2.0 7.1 2.2 1420 88 5.06613 1190
WE3-315L3-4 200 200 352 334 322 1490 95.8 96.0 96.0 0.86 0.88 0.90 2.0 7.1 2.2 1440 88 5.06292 1286
WE3-355M1-4 220 387 368 354 1495 95.8 96.0 96.0 0.84 0.87 0.89 2.0 7.1 2.2 1645 95 8.85473 1412
WE3-355M2-4 250 440 418 403 1495 95.6 96.0 96.0 0.85 0.88 0.90 2.0 7.1 2.2 1665 95 8.21532 1597
WE3-355L1-4 280 493 468 451 1495 95.4 96.0 96.0 0.85 0.88 0.90 2.0 7.1 2.2 1658 95 10.54836 1797
WE3-355L2-4 315 554 526 507 1495 94.9 96.0 96.0 0.86 0.87 0.90 2.0 7.1 2.2 1815 95 9.17059 2022
WE3-3551-4 355 355 639 607 585 1495 94.9 96.0 96.0 0.84 0.85 0.88 1.7 7.0 2.2 1995 102 10.31692 2275
WE3-3552-4 375 375 674 641 618 1495 94.9 96.0 96.0 0.84 0.85 0.88 1.7 7.0 2.2 2085 102 12.22746 2395
WE3 Series
Three - phase Asynchronous Motor

Technical parameters 6 pole 50Hz 19


Technical parameters 6 pole 50Hz

Rated Rated Rated Efficiency Power factor


Rated Rated Starting Starting Breakdown Moment
current current current Weight Noise Torque
Output Speed 50% 75% 100% 50% 75% 100% Torque Current Torque of inertia
at 380 V at 400 V at 415 V
Type Load Load Load Load Load Load

PN IN IN IN n  Cosφ mM MN
Tst/TN Ist/IN TM/TN dB(A) (kgm2)
(kW) (A) (A) (A) (min-1) (%) kg (Nm)
WE3-80M1-6 0.37 1,09 1.04 1 925 72.7 74.8 73.5 0.50 0.62 0.70 2.0 6.0 2.1 13 54 0.00212 3.82
WE3-80M2-6 0.55 1,5 1.43 1,38 925 77.0 78.6 77.2 0.53 0.65 0.72 2.0 6.0 2.1 15.5 54 0.00329 5.68
WE3-90S-6 0.75 2,03 1.93 1,86 940 77.5 79.3 78.9 0.51 0.64 0.71 2.0 6.0 2.1 24 57 0.00553 7.62
WE3-90L-6 1.1 2,83 2.69 2,59 945 81.1 82.1 81.0 0.55 0.67 0.73 2.0 6.0 2.1 27.5 57 0.00719 11.1
WE3-100L-6 1.5 3,78 3.60 3,47 960 81.5 83.2 82.5 0.57 0.68 0.73 2.0 6.5 2.1 37 61 0.01302 14.9
WE3-112M-6 2.2 5,36 5.09 4,91 950 82.6 84.5 84.3 0.56 0.67 0.74 2.0 6.6 2.1 46 65 0.02092 22.1
WE3-132S-6 3 7,2 6.84 6,59 960 82.4 86.4 85.6 0.57 0.68 0.74 2.0 6.8 2.1 57 69 0.02681 29.8
WE3-132M1-6 4 9,46 8.99 8,66 960 86.4 87.3 86.8 0.57 0.68 0.74 2.0 6.8 2.1 63 69 0.03412 39.8
WE3-132M2-6 5.5 12,7 12.0 11,6 965 87.3 88.2 88.0 0.58 0.69 0.75 2.0 7.0 2.1 78 69 0.04874 54.4
WE3-160M-6 7.5 16,2 15.4 14,8 970 88.0 89.2 89.1 0.63 0.74 0.79 2.0 7.0 2.1 116 73 0.11731 73.8
WE3-160L-6 11 23,1 22.0 21,2 970 89.3 90.4 90.3 0.64 0.75 0.8 2.0 7.2 2.1 142 73 0.17394 108
WE3-180L-6 15 30,9 29.3 28,2 975 90.5 91.4 91.2 0.69 0.78 0.81 2.0 7.3 2.1 181 73 0.26935 147
WE3-200L1-6 18.5 37,8 36.0 34,7 980 90.5 91.7 91.7 0.69 0.77 0.81 2.0 7.3 2.1 234 73 0.40188 180
WE3-200L2-6 22 44,8 42.5 41 980 91.2 92.2 92.2 0.68 0.77 0.81 2.0 7.4 2.1 254 73 0.46886 214
WE3-225M-6 30 59,1 56.2 54,1 980 91.8 92.9 92.9 0.78 0.81 0.83 2.0 6.9 2.1 328 74 0.96248 292
WE3-250M-6 37 71,7 68.1 65,7 985 92.6 93.3 93.3 0.72 0.80 0.84 2.0 7.1 2.1 416 76 1.27630 361
WE3-280S-6 45 85,8 81.6 78,6 985 92.0 93.7 93.7 0.78 0.82 0.85 2.0 7.3 2.0 543 78 2.64945 439
WE3-280M-6 55 103 98.1 94,6 985 92.6 94.1 94.1 0.76 0.83 0.86 2.0 7.3 2.0 635 78 3.32721 536
WE3-315S-6 75 143 136 131 990 94.3 94.6 94.6 0.77 0.80 0.84 2.0 6.6 2.0 1190 83 3.64703 727
WE3-315M-6 90 170 161 155 990 94.2 94.9 94.9 0.73 0.80 0.85 2.0 6.7 2.0 1320 83 4.24246 873
WE3-315L1-6 110 207 196 189 990 94.8 95.1 95.1 0.76 0.81 0.85 2.0 6.7 2.0 1430 83 5.21004 1066
WE3-315L2-6 132 244 232 224 990 94.9 95.4 95.4 0.77 0.83 0.86 2.0 6.8 2.0 1610 83 6.17762 1280
WE3-355M1-6 160 160 296 281 271 995 95.3 95.6 95.6 0.85 0.84 0.86 1.8 6.8 2.0 1710 85 9.81353 1551
WE3-355M2-6 200 200 365 346 334 995 94.6 95.8 95.8 0.81 0.84 0.87 1.8 6.8 2.0 1850 85 12.26691 1939
WE3-355L1-6 220 401 385 372 995 94.6 95.8 95.8 0.82 0.84 0.86 1.8 6.8 2.0 1905 85 13.37093 2112
WE3-355L2-6 250 250 456 433 417 995 95.2 95.8 95.8 0.82 0.85 0.86 1.8 6.8 2.0 2015 91 14.47495 2424
WE3-3551-6 280 511 491 473 995 95.2 95.8 95.8 0.82 0.85 0.86 1.8 6.8 2.0 2285 91 15.21097 2687
WE3-3552-6 315 315 575 546 526 995 95.2 95.8 95.8 0.82 0.85 0.86 1.8 6.8 2.0 2350 91 15.94698 3054
WE3 Series
Three - phase Asynchronous Motor

20 B3 cast iron motor installation and dimensions

B3 cast iron motor installation and dimensions

WE3-80-180

AD
F ES

HD
GD

AC
G

H
K
A
E C B

HA
AB
L

WE3-200-315 AD

F ES
HD
GD

AC
G

D
HA
H

K
A
E C B
AB
L

Subject to modifications Drawings for information purpose only


WE3 Series
Three - phase Asynchronous Motor

B3 cast iron motor installation and dimensions 21


B3 cast iron motor installation and dimensions

FRAME SIZE A B C D E F G H K AB AC AD HD L ES GD HA

80 125 100 50 19 40 6 15,5 80 10 157 163 136 221 299 32 21,5 10


90S 140 100 56 24 50 8 20 90 10 170 177 149 244 329 40 27 10
90L 140 125 56 24 50 8 20 90 10 170 177 149 244 351 40 27 10
100L 160 140 63 28 60 8 24 100 12 200 208 163 268 393 45 31 14
112M 190 140 70 28 60 8 24 112 12 226 226 189 305 408 45 31 15
132S 216 140 89 38 80 10 33 132 12 262 252 203 340 445 60 41 16
132M/L 216 178 89 38 80 10 33 132 12 262 252 203 340 483 60 41 16
160M 254 210 108 42 110 12 37 160 14,5 314 318 256 421 584 90 45 20
160L 254 254 108 42 110 12 37 160 14,5 314 318 256 421 628 90 45 20
180M 279 241 121 48 110 14 42,5 180 14,5 349 360 279 463 646 100 51,5 22
180L 279 279 121 48 110 14 42,5 180 14,5 349 360 279 463 684 100 51,5 22
200L 318 305 133 55 110 16 49 200 18,5 388 396 321 526 796 98 59 25
225S 356 286 149 60 140 18 53 225 18,5 431 442 345 570 846 110 64 28
225M-2 356 311 149 55 110 16 49 225 18,5 431 442 345 570 841 90 59 28
225M-4/6 356 311 149 60 140 18 53 225 18,5 431 442 345 570 871 110 64 28
250M-2 406 349 168 60 140 18 53 250 24 484 488 446 696 929 110 64 30
250M-4/6 406 349 168 65 140 18 58 250 24 484 488 446 696 929 110 69 30
280S-2 457 368 190 65 140 18 58 280 24 542 547 449 728 1007 110 69 35
280S-4/6 457 368 190 75 140 20 67,5 280 24 542 547 449 728 1007 110 79,5 35
280M-2 457 419 190 65 140 18 58 280 24 542 547 449 728 1055 110 69 35
280M-4/6 457 419 190 75 140 20 67,5 280 24 542 547 449 728 1055 110 79,5 35
315S-2 508 406 216 65 140 18 58 315 28 628 631 507 822 1132 110 69 40
315S-4/6 508 406 216 80 170 22 71 315 28 628 631 507 822 1162 140 85 40
315M-2 508 457 216 65 140 18 58 315 28 628 631 507 822 1232 110 69 40
315M-4/6 508 457 216 80 170 22 71 315 28 628 631 507 822 1262 140 85 40
315L-2 508 508 216 65 140 18 58 315 28 628 631 507 822 1232 110 69 40
315L-4/6 508 508 216 80 170 22 71 315 28 628 631 507 822 1262 140 85 40
355M-2 610 560 254 75 140 20 67,5 355 28 740 709 644 999 1432 110 79,5 45
355M-4/6 610 560 254 95 170 25 86 355 28 740 709 644 999 1462 160 100 45
355L-2 610 630 254 75 140 20 67,5 355 28 740 709 644 999 1602 110 79,5 45
355L-4/6 610 630 254 95 170 25 86 355 28 740 709 644 999 1632 160 100 45
3551/2-2 630 630 254 75 170 20 71 355 35 740 709 644 999 1632 140 85 45
3551/2-4/6 630 630 254 95 210 25 100 355 35 740 709 644 999 1672 200 116 45
WE3 Series
Three - phase Asynchronous Motor

22 B5 cast iron motor installation and dimensions

B5 cast iron motor installation and dimensions

WE3-80-180

S
M

HD
GD

AC
N
P
G

D
E

WE3-200-355

S
F

HD
GD

AC
A
P
G

D
E

Subject to modifications Drawings for information purpose only


WE3 Series
Three - phase Asynchronous Motor

B5 cast iron motor installation and dimensions 23


B5 cast iron motor installation and dimensions

FRAME SIZE D E F G M N P S T AC AD L GD

80 19 40 6 15,5 165 130 200 4-12 3,5 163 136 299 21,5
90S 24 50 8 20 165 130 200 4-12 3,5 177 149 329 27
90L 24 50 8 20 165 130 200 4-12 3,5 177 149 351 27
100L 28 60 8 24 215 180 250 4-14.5 4 208 163 401 31
112M 28 60 8 24 215 180 250 4-14.5 4 226 189 417 31
132S 38 80 10 33 265 230 300 4-14.5 4 252 203 454 41
132M/L 38 80 10 33 265 230 300 4-14.5 4 252 203 492 41
160M 42 110 12 37 300 250 350 4-18.5 5 318 256 590 45
160L 42 110 12 37 300 250 350 4-18.6 5 318 256 634 45
180M 48 110 14 42,5 300 250 350 4-18.7 5 360 279 655 51,5
180L 48 110 14 42,5 300 250 350 4-18.8 5 360 279 693 51,5
200L 55 110 16 49 350 300 400 4-18.9 5 396 321 796 59
225S 60 140 18 53 400 350 450 8-18.5 5 442 345 846 64
225M-2 55 110 16 49 400 350 450 8-18.5 5 442 345 841 59
225M-4/6 60 140 18 53 400 350 450 8-18.5 5 442 345 871 64
250M-2 60 140 18 53 500 450 550 8-18.5 5 488 446 929 64
250M-4/6 65 140 18 58 500 450 550 8-18.5 5 488 446 929 69
280S-2 65 140 18 58 500 450 550 8-18.5 5 547 449 1007 69
280S-4/6 75 140 20 67,5 500 450 550 8-18.5 5 547 449 1007 79,5
280M-2 65 140 18 58 500 450 550 8-18.5 5 547 449 1055 69
280M-4/6 75 140 20 67,5 500 450 550 8-18.5 5 547 449 1055 79,5
315S-2 65 140 18 58 600 550 660 8-24 6 631 507 1132 69
315S-4/6 80 170 22 71 600 550 660 8-24 6 631 507 1162 85
315M-2 65 140 18 58 600 550 660 8-24 6 631 507 1232 69
315M-4/6 80 170 22 71 600 550 660 8-24 6 631 507 1262 85
315L-2 65 140 18 58 600 550 660 8-24 6 631 507 1232 69
315L-4/6 80 170 22 71 600 550 660 8-24 6 631 507 1262 85
355M-2 75 140 20 67,5 740 680 800 8-24 6 709 644 1432 79,5
355M-4/6 95 170 25 86 740 680 800 8-24 6 709 644 1462 100
355L-2 75 140 20 67,5 740 680 800 8-24 6 709 644 1602 79,5
355L-4/6 95 170 25 86 740 680 800 8-24 6 709 644 1632 100
3551/2-2 80 170 22 67,5 740 680 800 8-24 6 709 644 1632 85
3551/2-4/6 110 210 21 86 740 680 800 8-24 6 709 644 1672 116

Subject to modifications Drawings for information purpose only


WE3 Series
Three - phase Asynchronous Motor

24 B35 cast iron motor installation and dimensions

B35 cast iron motor installation and dimensions

WE3-80-180

M
S

AD
F

HD
GD
P

AC
N
G

D
E

H
K
A
C B

HA
L AB

WE3-200-355

T
AD

S
F
HD
GD

AC
A
P
G

D
E
HA
H

K
A
C B
AB
L

Subject to modifications Drawings for information purpose only


WE3 Series
Three - phase Asynchronous Motor

B35 cast iron motor installation and dimensions 25


B35 cast iron motor installation and dimensions

FRAME SIZE A B C D E F G H K M N P S T AB AC AD HD L GD HA

80 125 100 50 19 40 6 15,5 80 10 165 130 200 4-12 3,5 157 163 136 221 299 21,5 10

90S 140 100 56 24 50 8 20 90 10 165 130 200 4-12 3,5 170 177 149 244 329 27 10

90L 140 125 56 24 50 8 20 90 10 165 130 200 4-12 3,5 170 177 149 244 351 27 10

100L 160 140 63 28 60 8 24 100 12 215 180 250 4-14.5 4 200 208 163 268 401 31 14

112M 190 140 70 28 60 8 24 112 12 215 180 250 4-14.5 4 226 226 189 305 417 31 15

132S 216 140 89 38 80 10 33 132 12 265 230 300 4-14.5 4 262 252 203 340 454 41 16

132M/L 216 178 89 38 80 10 33 132 12 265 230 300 4-14.5 4 262 252 203 340 492 41 16

160M 254 210 108 42 110 12 37 160 14,5 300 250 350 4-18.5 5 314 318 256 421 590 45 20

160L 254 254 108 42 110 12 37 160 14,5 300 250 350 4-18.6 5 314 318 256 421 634 45 20

180M 279 241 121 48 110 14 42,5 180 14,5 300 250 350 4-18.7 5 349 360 279 463 655 51,5 22

180L 279 279 121 48 110 14 42,5 180 14,5 300 250 350 4-18.8 5 349 360 279 463 693 51,5 22

200L 318 305 133 55 110 16 49 200 18,5 350 300 400 4-18.9 5 388 396 321 526 796 59 25

225S 356 286 149 60 140 18 53 225 18,5 400 350 450 8-18.5 5 431 442 345 570 846 64 28

225M-2 356 311 149 55 110 16 49 225 18,5 400 350 450 8-18.5 5 431 442 345 570 841 59 28

225M-4/6 356 311 149 60 140 18 53 225 18,5 400 350 450 8-18.5 5 431 442 345 570 871 64 28

250M-2 406 349 168 60 140 18 53 250 24 500 450 550 8-18.5 5 484 488 446 671 929 64 30

250M-4/6 406 349 168 65 140 18 58 250 24 500 450 550 8-18.5 5 484 488 446 671 929 69 30

280S-2 457 368 190 65 140 18 58 280 24 500 450 550 8-18.5 5 542 547 449 728 1007 69 35

280S-4/6 457 368 190 75 140 20 67,5 280 24 500 450 550 8-18.5 5 542 547 449 728 1007 79,5 35

280M-2 457 419 190 65 140 18 58 280 24 500 450 550 8-18.5 5 542 547 449 728 1055 69 35

280M-4/6 457 419 190 75 140 20 67,5 280 24 500 450 550 8-18.5 5 542 547 449 728 1055 79,5 35

315S-2 508 406 216 65 140 18 58 315 28 600 550 660 8-24 6 628 631 507 822 1132 69 40

315S-4/6 508 406 216 80 170 22 71 315 28 600 550 660 8-24 6 628 631 507 822 1162 85 40

315M-2 508 508 216 65 140 18 58 315 28 600 550 660 8-24 6 628 631 507 822 1232 69 40

315M-4/6 508 508 216 80 170 22 71 315 28 600 550 660 8-24 6 628 631 507 822 1262 85 40

315L-2 508 508 216 65 140 18 58 315 28 600 550 660 8-24 6 628 631 507 822 1232 69 40

315L-4/6 508 508 216 80 170 22 71 315 28 600 550 660 8-24 6 628 631 507 822 1262 85 40

355M-2 610 560 254 75 140 20 67,5 355 28 740 680 800 8-24 6 740 709 644 999 1432 79,5 45

355M-4/6 610 560 254 95 170 25 86 355 28 740 680 800 8-24 6 740 709 644 999 1462 100 45

355L-2 610 610 254 75 140 20 67,5 355 28 740 680 800 8-24 6 740 709 644 999 1602 79,5 45

355L-4/6 610 610 254 95 170 25 86 355 28 740 680 800 8-24 6 740 709 644 999 1632 100 45

3551/2-2 610 610 254 80 170 22 67,5 355 35 740 680 800 8-24 6 740 709 644 1010 1632 85 45

3551/2-4/6 610 610 254 110 210 21 86 355 35 740 680 800 8-24 6 740 709 644 1010 1672 116 45

Subject to modifications Drawings for information purpose only


WE3 Series
Three - phase Asynchronous Motor
Terminal Box

26
Size of Lifting eye
Threaded hole by shaft end

Terminal Box

Single hole cable grand can be locked the diameter of


Frame AxBxH(mm) Cable entry Terminal thread
cable grand (mm)
80 90x96x50 1-M25x1.5 Ø8-Ø12 M4
90-100 102x110x57.5 1-M25x1.5 Ø8-Ø12 M5
112-132 136x146x72 2-M25x1.5 Ø8-Ø12 M5
160-180 171x181x91 2-M32x1.5 Ø16-Ø21 M6
200-225 220x230x113 2-M50x1.5 Ø32-Ø39 M8
250-280 270x280x116.5 2-M63x1.5 M10
Ø37-Ø44
315 312x329x175 2-M63x1.5 M12
355 382x402x200 2-M72x2 Ø45-Ø53 M16

Size of lifting eye

Horizontal mounting
Frame size Lifting eye size
Quantity Position
H80-90S --- --- --- --- --- ---
H90L~112 M8 1
H132 M10 1
Top
H160 M12 1
H180 M16 1
H200-225 M20 2
H250-280 M24 2 Top, both sides of terminal box
H315 M30 2 Left front and right rear view from shaft end
H355 M36 2

Threaded hole by shaft end (selectabletable)

No. Frame size Hole size


1 H80 M6*16
2 H90 M8*19
3 H100 M10*22
4 H112 M10*28
5 H132 M12*28
6 H160 M16*36
7 H180 M16*36
8 H200-280 M20*42
9 H315 M20*42
10 H355 M20*45
Contact
AsiaWolong International Europe America’s

Zhejiang Wolong International Business Co., Ltd Wolong EMEA (Germany) Wolong Americas LLC
No.1801, Renmin West Road Schwalmstraße 289 26410 Oakridge DR, suite #101
Shangyu, Zheijang, China 41238 Mönchengladbach Spring, TX 77380, USA
T +86 (0) 575 823 98874 T +49 (0) 7182 14–1 T +1 (346) 616-0102
F +86 (0) 575 821 76717 F +49 (9) 7182 14-590
[email protected] [email protected] [email protected]
www.wolong.com/en www.wolong.com/en www.wolong.com/en

www.wolong.com/en www.atb-motors.com