CYK10/CYK11
a0018829
Measuring system
1 Transmitter
2 Memosens extension cable CYK11 (optional)
3 Junction box (optional)
4 Memosens data cable CYK10 or fixed cable
5 Sensor
Memosens Memosens makes your measuring point safer and more reliable:
• Non-contact, digital signal transmission enables optimum galvanic isolation
• No contact corrosion
• Completely watertight
• Laboratory sensor calibration possible, thus increasing measured value availability
• Predictive maintenance thanks to recording of sensor data, e.g.:
– Total hours of operation
– Hours of operation with very high or very low measured values
– Hours of operation with high temperatures
– Number of steam sterilizations
– Sensor condition
a0013430
2 Endress+Hauser
CYK10/CYK11
Connection in explo-
sion-hazardous areas
a0018789
It is not allowed to use CYK11 as an extension for CYK10-based measuring system in hazardous areas.
For hazardous areas it is recommended to use continuous and not extended Memosens measuring cable
CYK10.
Endress+Hauser 3
CYK10/CYK11
Cable specification
CYK10 CYK11
Conductor/Construction 4 cores 6 cores
Outer diameter (mm) 6,3 6,3
Shielding Yes Yes
Bending radius solid 5xD 5xD
Bending radius flexible 10xD 10xD
Performance characteristics
Resistance CYK10 CYK11
UV resistant Yes Yes
Clear of ozon-depleting substances Yes Yes
Halogen-free No Yes
RoHs-compliant Yes Yes
Flame-resistant Yes Yes
Oil-resistant - Yes
Environment
Ambient temperature range CYK10 CYK11
Temperature min. -25 °C (-13 °F) -30 °C (-22 °F)
Temperature max. 135 °C (277 °F) 90 °C (194 °F)
Degree of protection • Memosens data cable CYK10: IP 68 (Memosens: 1 bar (15 psi), 25 °C (77 °F), 1 mol/l KCl, 45 days;
M12: 0.1 bar (2 psi), 50 °C (131 °F), 3 mol/l KCl, 30 days)
• Memosens extension cable CYK11: IP 68 (M12: 0.1 bar (2 psi), 50 °C (131 °F), 3 mol/l KCl, 30 days)
in mated condition
a0003350
Instead of GY you can also ground over the cable clamp in the transmitter.
CYK10 with M12 plug
a0016912
4 Endress+Hauser
CYK10/CYK11
a0015715-en
a0015716-en
a0016506-en
a0016913
Endress+Hauser 5
CYK10/CYK11
a0016200
Ex approval CYK10-G**a, a = 1, 2
CYK10-I**a, a = 1, 2
• IECEx
Ex ia IIC T3/T4/T6 Ga
• ATEX
II 1G Ex ia IIC T3/T4/T6 Ga
• FM/CSA
IS/NI CLI Div1&2 GP ABCD
• Nepsi
II 1G Ex ia IIC T3/T4/T6 Ga
6 Endress+Hauser
CYK10/CYK11
Ordering information
Product structure You can create a valid and complete order code using the Endress + Hauser Configurator tool on the Internet.
Enter the following addresses in your browser to access the relevant product page:
www.products.endress.com/cyk10
www.products.endress.com/cyk11
1. The following options are available on the right-hand side of the page:
Endress+Hauser 7
TI00118C/07/EN/13.11
71139045