5 11 2 8 7 15

The TD62LM and TD62M are maintainable high pressure thermodynamic steam traps with integral strainer and a replaceable seat to ease maintenance. They have been specifically designed for mains drainage applications up to 62 bar g. The TD62LM is specifically designed for relatively small condensate loads on superheat and mains drainage applications. An insulating cover is fitted as standard to prevent the trap being unduly influenced by excessive heat loss when subjected to low ambient temperatures, wind or rain. Standards This product fully complies with the requirements of the European Pressure Equipment Directive 97 /23 /EC. Certification This product is available with certification to EN 10204 3.1. Note: All certification / inspection requirements must be stated at the time of order placement.

Description

9 6 10 14 13

4 1 10 8A 9 3

Sizes and pipe connections

DN15, DN20 and DN25 Standard flange to ANSI B 16.5 Class 300 and 600, and JIS / KS 40K. ANSI Class 150 RF connections are available to special order.

Pressure / temperature limits


Temperature C Steam saturation curve A

Pressure bar g

Materials
No. 1 2 3 4 5 6 *7 8 8A 9 Part Body Top cover Bottom cover Strainer screen Insulating cover Disc Seat Cover studs (top) Cover studs (bottom) Cover nuts Material Steel ASTM A217 WC6 Steel ASTM A217 WC6 Steel ASTM A217 WC6 Stainless steel 100 mesh 316L Aluminium Chromium steel Chromium steel Steel ASTM A193 B16 Steel ASTM A193 B16 Steel ASTM A194 8M Spirally wound stainless steel with exfoliated graphite filler Stainless steel Spirally wound stainless steel with exfoliated graphite filler Spirally wound stainless steel with exfoliated graphite filler Stainless steel

The product must not be used in this region. The product should not be used in this region or beyond its operating range as damage to the internals may occur. A - B Flanged to ANSI B 16.5 Class 600. A - C Flanged to JIS /KS 40K. A - D Flanged to ANSI B 16.5 Class 300. Body design conditions PMA Maximum allowable pressure TMA Maximum allowable temperature Minimum allowable temperature PMO Maximum operating pressure for steam service ANSI 600 103 bar g @ 93C 525C @ 42.7 bar g 0C 62 bar g @ 482C

10 Cover gaskets 11 Name-plate 13 Inner seat gasket 14 Outer seat gasket * 15 Ferrule

TMO Maximum operating temperature 525C @ 42.7 bar g Minimum operating temperature 0C Maximum operating TD62LM 50% of upstream pressure PMOB backpressure TD62M 80% of upstream pressure TD62LM 8 bar g Minimum operating pressure TD62M 1.4 bar g Designed for a maximum cold hydraulic test pressure of 155 bar g

* Note: Item 15 (ferrule) is pressed into item 7 (seat).

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice.

Copyright 2006

Dimensions /weights (approximate) in mm and kg


Size DN15 DN20 DN25 A 87 87 87 ANSI ANSI JIS/KS 600 300 40K B B B C 147 135 146 92 151 138 146 92 160 147 156 92 D 72 72 72 E 40 40 40 F 30 30 30 Weight 8.5 8.5 9.1

Spare parts

The spare parts available are shown in solid outline. Parts shown in broken line are not supplied as spares. Available spares Insulating cover Set of cover studs and nuts (set of 8) Seat and disc assembly Strainer screen 100 mesh Set of gaskets (packet of 3 sets) Cover gaskets (3 off) 5 8, 8A, 9 6, 7, 10, 13, 14, 15 4 10, 13, 14 10

F Withdrawal distance C

How to order spares Always order spares by using the description given in the column headed 'Available spares' and state the size and type of trap. Example: 1 - Strainer screen for a Spirax Sarco DN25 TD62LM thermodynamic steam trap (ASTM body). A 5

D 6 10 B E Withdrawal distance 7 + 15 14 13 8

Capacities

Condensate kg /h


8A

Minimum operating pressure 8 bar for the TD62LM Differential pressure bar (x 100 = kPa)

Safety information, installation and maintenance

10

For full details see the Installation and Maintenance Instructions (IM-P068-58) supplied with the product. Installation note: Preferably install in horizontal pipelines with the insulating cover uppermost although it can be fitted in other positions. After 24 hours in service the cover nuts should be checked for tightness. Disposal The product is recyclable no ecological hazard is anitcipated with the disposal of this product, providing due care is taken.

9 Recommended tightening torques or Item No. mm 8 and 8A M10 x 1.5 9 17 A /F

How to order

Example: 1 off Spirax Sarco DN20 TD62LM thermodynamic steam trap with ASTM steel body having an integral strainer having a replaceable seat and flanged ANSI 600 connections suitable for steam mains drainage. An aluminium insulating cover shall be fitted as standard.

Nm 20 - 25 45 - 50

TD62LM and TD62M Thermodynamic Steam Traps with replaceable seats ASTM Body (Flanged connections)

TI-P068-20 ST Issue 7