AVR-15 Manual E
AVR-15 Manual E
AVR-15 Manual E
, Ltd AVR-15
AVR-15
User Manual
Web Site:http://www.monicon.com.tw
E - m a i l :s a l e s @ m o n i c o n . c o m . t w
Monicon International Co., Ltd AVR-15
1. Description:
The AVR-15 stabilizes the output voltage by detecting the phase output and make
necessary adjustments to the exciter accordingly. The AVR-15 is suitable for use on
brushless generator model.
2. Wiring:
:
The range of sensing the phase voltage in the AVR-15 is AC 110 /220V. The input
voltage for AVR-15 is 100 ~ 240VAC, 50/60Hz. Please follow the instructions and wiring
diagram for the AVR-15 to prevent any malfunctions.
2.1. AC input Terminals are for Genset voltage sensing and power for AVR-15.
※Warning:
:The power input for AVR-
AVR-15 must not exceed 240V
240V AC.
3. Adjustments:
:
3.1 Frequency Setting:
:
Please switch frequency selector to “ON” position when rated frequency is 50Hz
※Warning:
Warning: Pl
Please
ease pay extra attentions when setting
setting up the voltage and frequency
selectors;
selectors; incorrect settings could damage the AVR or the generator.
※Note:
Note: Make sure all the wires, connections, and settings are all correct and turn
the Volt and Stable fully counterclockwise
counterclockwise before starting the generator.
Monicon International Co., Ltd AVR-15
4. Excitation:
:
※ Warning:
Warning:Incorrect wiring of Genset
Genset or operation of the AVR for the first time or the
residual magnetism voltage is less than 5V or (F+) and (F-
(F-) is connected reversely;
reversely;
the generator will not be able to build up voltage.
If the Genset can not build up the voltage, please shut down the generator and than
perform the following steps:
4.1. Please shut down the generator and check the wiring.
4.1.1 Incorrect wiring:Please rewire and than start the generator again.
4.1.2 If Genset still can not build up the voltage, please shut down the generator
and proceed to step 4.2.
4.1.3 If wiring is correct, please shut down the Genset and proceed to step 2.
4.2. Please shut down the generator before perform the following steps
4.2.1 Reverse (F+) and (F-) connections, than start the Genset again.
4.2.2 If Genset still can not build up the voltage, an external power source must be
Monicon International Co., Ltd AVR-15
used to excite the magnetism. Please make sure the generator has been
completely shut down before proceed to step 3.
4.3 . Please shut down the generator before perform the following steps
4.3.1 Disconnect AVR terminals (F+) and (F-), then use 3-12V DC (e.g. battery) as
power source and connect the positive terminal to a current limiting resistor
5~50Ω/30W, then connect to the positive terminal of the Genset and
negative to the negative terminal of the Genset. (Please refer to figure. 4)
Power up for 3 seconds and then disconnect the power source. Remove the
AVR power input and start the Genset. Wait until the rated idle speed, than
measure the residual magnetic voltage.
4.3.2 If the residual magnetic voltage is greater than 5V AC, please shut down the
Genset and reconnect the AVR than start the Genset again.
4.3.3 If the residual magnetic voltage is less than 5V AC, please repeat step 3
again.
4.4. If the residual magnetic voltage is greater than 5V AC and the Genset still can not
build up the voltage, please replace with another AVR.
Warning:
※Warning : Over excitation may damage the exciter or the AVR.
5. Specifications:
:
、C) Voltage 110/220, single phase 2 wires,
Voltage Detection Range(A、
Frequency 50/60 Hz
(Factory default setting: 220VAC, 60 Hz)
6. Troubleshooting:
:
7. Dimensions:
Figure 1
Figure 2
Monicon International Co., Ltd AVR-15
Figure 3
Monicon International Co., Ltd AVR-15
Figure 4:Excitation