AVR-15 Manual E

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Monicon International Co.

, Ltd AVR-15

AVR-15
User Manual

Web Site:http://www.monicon.com.tw 
E - m a i l :s a l e s @ m o n i c o n . c o m . t w
Monicon International Co., Ltd AVR-15

1. Description:
The AVR-15 stabilizes the output voltage by detecting the phase output and make
necessary adjustments to the exciter accordingly. The AVR-15 is suitable for use on
brushless generator model.

2. Wiring:

The range of sensing the phase voltage in the AVR-15 is AC 110 /220V. The input
voltage for AVR-15 is 100 ~ 240VAC, 50/60Hz. Please follow the instructions and wiring
diagram for the AVR-15 to prevent any malfunctions.

2.1. AC input Terminals are for Genset voltage sensing and power for AVR-15.

※Warning:
:The power input for AVR-
AVR-15 must not exceed 240V
240V AC.

2.2. Connect output terminals(F+)、(F-) to the exciter on the generator.

2.3. External connector EXT.VR is for external potentiometer (1KΩ 1W VR).


2
※Warning: :Please use AWG14
AWG14 or 2.05mm
2.05mm 85℃ 85℃ 600 V wire for connectors AC、
AC、F+、
F+、
insolated
F-. For use on external potentiometer, please use insolated wires.

3. Adjustments:

3.1 Frequency Setting:

Please switch frequency selector to “ON” position when rated frequency is 50Hz

3.2 Voltage Setting:



Please switch voltage selector to “ON” position when the rated output phase voltage
is 110V AC.

※Warning:
Warning: Pl
Please
ease pay extra attentions when setting
setting up the voltage and frequency
selectors;
selectors; incorrect settings could damage the AVR or the generator.

※Note:
Note: Make sure all the wires, connections, and settings are all correct and turn
the Volt and Stable fully counterclockwise
counterclockwise before starting the generator.
Monicon International Co., Ltd AVR-15

3.3 Genset Voltage Fine Tune(Volt):



After Genset has successfully started and in rated speed, slowly turn Volt clockwise
to the rated voltage. (If EXT.VR is connected with a potentiometer, please adjust the
potentiometer to the center position)

3.4 Genset Stabilization Adjustment(Stable):



To adjust the feedback timing, slowly turn the Stable clockwise. We suggest using
analog DC voltmeter to monitor (F+) and (F-) then fine tune the meter until the
movement is at minimum. Over adjustment may cause unstable voltage output. Under
adjustment may have significant changes on the output voltage under heavy load.

3.5 Genset Low Frequency Setting(U/F):



Please do not adjust this setting, the U/F setting has been adjusted at the factory. Its
purpose is to activate the low frequency protection. When the output frequency of the
generator is lower than this setting, the AVR ceases the output and activates LED warning
light automatically.

4. Excitation:

※ Warning:
Warning:Incorrect wiring of Genset
Genset or operation of the AVR for the first time or the
residual magnetism voltage is less than 5V or (F+) and (F-
(F-) is connected reversely;
reversely;
the generator will not be able to build up voltage.

If the Genset can not build up the voltage, please shut down the generator and than
perform the following steps:

4.1. Please shut down the generator and check the wiring.
4.1.1 Incorrect wiring:Please rewire and than start the generator again.
4.1.2 If Genset still can not build up the voltage, please shut down the generator
and proceed to step 4.2.
4.1.3 If wiring is correct, please shut down the Genset and proceed to step 2.

4.2. Please shut down the generator before perform the following steps
4.2.1 Reverse (F+) and (F-) connections, than start the Genset again.
4.2.2 If Genset still can not build up the voltage, an external power source must be
Monicon International Co., Ltd AVR-15
used to excite the magnetism. Please make sure the generator has been
completely shut down before proceed to step 3.

4.3 . Please shut down the generator before perform the following steps
4.3.1 Disconnect AVR terminals (F+) and (F-), then use 3-12V DC (e.g. battery) as
power source and connect the positive terminal to a current limiting resistor
5~50Ω/30W, then connect to the positive terminal of the Genset and
negative to the negative terminal of the Genset. (Please refer to figure. 4)
Power up for 3 seconds and then disconnect the power source. Remove the
AVR power input and start the Genset. Wait until the rated idle speed, than
measure the residual magnetic voltage.
4.3.2 If the residual magnetic voltage is greater than 5V AC, please shut down the
Genset and reconnect the AVR than start the Genset again.

4.3.3 If the residual magnetic voltage is less than 5V AC, please repeat step 3
again.
4.4. If the residual magnetic voltage is greater than 5V AC and the Genset still can not
build up the voltage, please replace with another AVR.
Warning:
※Warning : Over excitation may damage the exciter or the AVR.

5. Specifications:

、C) Voltage 110/220, single phase 2 wires,
Voltage Detection Range(A、
Frequency 50/60 Hz
(Factory default setting: 220VAC, 60 Hz)

Input Voltage Range(B、


、C) Voltage: 100~240 VAC single phase 2 wires
Frequency: 50/60 Hz

Voltage Adjustable Range When External VR is 1KΩ and ±7%

Min. rated power is 1W

Voltage Adjustable Rate: < ±0.5 %


Min. Excitation Voltage: Residual voltage > 5 VAC
Magnetic Field
Field Output: Continuous current:15A,intermittent: 20 A
Exciter Resistance: 15Ω(Min)
100Ω(Max)
Monicon International Co., Ltd AVR-15
Low Frequency Protection:
Protection Genset 60 Hz: Lower than 55Hz, AVR ceases
output (Default setting)
Genset 50 Hz: Lower than 45Hz, AVR ceases
output (Default setting)
EMI Protection: Build in EMI filter
Power Consumption: 10 Watt(Max)。
Fuse 16A / 250V / 20mm
Working Temperature: 0 ℃ ~ 65 ℃。
Storage Temperature: ﹣20 ℃ ~ 85 ℃。
Dimensions: W 100 * H 58 * D 150 mm。
Weight: 312g ± 15g

6. Troubleshooting:

Scenario Possible Cause Solution


 Bad connections on (F+、F-) Please refer to figure 3 and 4.
 Low residual voltage Please see 4.3、figure4
No output
 Low engine speed Please refer to Genset manual
voltage
 Faulty generator Please refer to Genset manual
 Blown Fuse Replace fuse with same spec.
High output  Bad connections or incorrect settings Please refer to figure 3 and 4
voltage on voltage sensing switch.
 Incorrect settings on Voltage sensing Please refer to figure 3 and45
switch
 Bad connections on external Please check the wiring and
Low output potentiometer follow the diagram
voltage  Faulty or damaged potentiometer Test and replace potentiometer
 Low engine speed Please refer to Genset manual
 Incorrect exciter installed Please refer to Genset manual
 Blown Fuse Replace fuse with same spec
Unstable  Miss adjustment on STAB
output voltage
Burned Fuse  Too much current on exciter Please refer to Genset manual
Replace fuse with same spec
Monicon International Co., Ltd AVR-15

7. Dimensions:

Figure 1

Figure 2
Monicon International Co., Ltd AVR-15

8. Wiring Diagram and Settings:


Figure 3
Monicon International Co., Ltd AVR-15

Figure 4:Excitation