p80rn4182 Ver0 1
p80rn4182 Ver0 1
p80rn4182 Ver0 1
8600
Software Release 4.1.8.2
1. Release Summary
Release Date: 9 February, 2009
Purpose: Software maintenance release to address software issues found both in the field and internally.
NOTE: For those customers who were part of the 4.1.8.0 Controlled Release program, an upgrade to 4.1.8.2 is
not required. The CRs listed in italic below are the external CRs changed between 4.1.8.0 and 4.1.8.2.
When upgrading a pair of IST Core peer switches, special care must be taken due to SMLT architectural change
(see Section 7 - New Features). Unlike previous upgrades, when moving from pre- 4.1.8.x code to any 4.1.8.x or
higher code, the IST peer switch operation will be different during the upgrade process. When the first peer
switch is upgraded (secondary SSF/CPU first, and then primary SSF/CPU), this switch will go into an ALL port
lock state, with the IST_MLT being the only links/ports up and active. The SMLT connected portion of the
network will continue to operate on the second IST Core switch, still running the pre-4.1.8.x image. The user
should now wait approximately 5 minutes until the following message is seen on the upgrade 4.1.8.x switch:
CPU5 [05/15/08 05:33:55] MLT ERROR SMLT initial table sync is delayed or failed. Please check the peer switch
for any partial config errors. All the ports in the switch except IST will remain locked
At this time, the second IST Core peer switch can be upgraded. At that time, and when the 1st now running
4.1.8.x switch sees its IST_MLT connection go down, it will unlock all its ports, and start learning and then
forwarding traffic. This upgrade process will cause some user traffic impact, even for the SMLT connected
portion of the network. The 2nd IST Core switch once finished upgrading should show the following messages in
its log – these should be checked for to confirm proper upgrade and operation:
CPU5 [06/05/08 05:05:45] MLT INFO SMLT MAC/ARP Sync Requested: CAUTION do not take ANY action with
the peer at this time
CPU5 [06/05/08 05:05:46] MLT INFO SMLT MAC /ARP Sync is Complete : Peer can now be used normally
After both IST Core peer switches are upgraded and network is running 'normally', it is now recommended to
power-cycle (re-boot only for single SSF/CPU systems) the one peer switch which was upgraded first so that a
complete "sync" (see Section 7) will now occur.
After upgrading to 4.1.8.x or higher code, the future upgrade process will return to the behavior previously
documented. When one IST Core peer switch is upgraded, the SMLT portion of the network will continue
operation without user impact on the other IST Core peer. The second IST Core peer switch can then be
upgraded in the same manner, resulting in little to no user traffic impact for the SMLT connected portion of the
network.
NOTE: After upgrading there is a very small potential for invalid (but not operationally affecting) ARP entries to
show up in the ARP table. These entries start with an IP address with the number 0 (0.x.x.x). Running the
command ‘show ip arp info 0.’ will show if such entries exist. If no values are returned, then you are all set. If
entries are returned, please contact Nortel Support and request Level 2 GNPS assistance.
3. Platforms Supported
All Ethernet Routing Switch 8600 modules are supported in the 8006, 8010, and 8010co Chassis. Full slot
support for all modules may be dependant on the presence of the High Performance Backplane. Reference
4.1.1.0 RN document below for further details.
Please refer to the following documents for details on the Platforms Supported:
Release Notes for the Ethernet Routing Switch 8600 Series Switch Software Release 4.1.1.0 (Part No.
317177-E)
Installing Ethernet Routing Switch 8600 Switch Modules (Part No. 312749-K Rev 01)
Managing Platform Operations Ethernet Routing Switch 8000 Series Software Release 4.1 (Part No.
315545-E Rev 00)
Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis (Part No. 316314-F Rev 01)
Note: R-series modules are supported in the 8010co chassis with a High Performance Backplane. Please see
ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
p80a4182.mib MIB
3329553
p80a4182.mib.zip MIB (zip file)
533374
p80a4182.md5 md5 checksum file
1768
p80p4182.dld 8600 POS module image
701771
p80t4182.dld 8600 ATM module image
906024
8600 image for the SuperMezz
8909615
p80m4182.img card
Firmware images
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR (only applies to
2284578
8630GBR modules)
SSL Images
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.9.0 or higher.
This software release supports the Web Switching Module (WSM) release WebOS 10.0.34.0. This code is found
on Nortel web site under Content Networking -> Web Switches -> Ethernet Routing Switch Web Switch Module.
This software release supports SDM FW Release up to 2.3.7.0. This code is found on Nortel web site under
Security & VPN -> Service Delivery Module 8660, which provides a link to CheckPoint web site.
This software release supports SDM TPS Release up to4.7.0.2. This code is found on Nortel web site under
Security & VPN -> Service Delivery Module 8660.
To download any of these code releases requires valid Nortel support web access, as well as valid CheckPoint
support site access for most FW code.
The SMLT changes in this release improve this operation significantly, and continue to allow all previous
SMLT/RSMLT topologies to be supported. SMLT Operational Improvements will affect SMLT/RSMLT behavior in
that the actual SMLT/RSMLT connection links on a powered-up IST Core Switch, will take longer to become
active (link status up and forwarding) than with previous versions of code. During this time period the other Peer
IST Core Switch will always be continuing to forward, therefore avoiding any loss of traffic in the network for all
SMLT/RSMLT based connections. The SMLT/RSMLT associated links will not become active upon a boot-up
until the IST is completely up, and a ‘new MAC/ARP/IP sync’ has occurred between the two Core IST Peer
Switches in a Cluster.
Users may see occasional instances where the Remote SMLT Flag is False on both Peer Switches. This is
normal, if the flag clears and is then set properly (False on one side, True on the other), once the FDB age-out for
that associated VLAN has occurred. This behavior has no affect on user traffic operation – no user traffic loss or
disruption will be seen under this condition.
Additionally users will see some new informational log messages generated around this behavior. The new
messages formats are listed below, along with the various situations they will be seen with.
Case 1: Switch running SMLT is reset. Upon switch coming up the below messages are displayed irrespective of
the number of SMLTs:
CPU5 [06/05/08 05:05:45] MLT INFO SMLT MAC/ARP Sync Requested: CAUTION do not take ANY action with
the peer at this time
CPU5 [06/05/08 05:05:46] MLT INFO SMLT MAC /ARP Sync is Complete : Peer can now be used normally
Case 2: System is up and running but SMLT UP event (from down) has happened. One sync message is
displayed for every SMLT that went down and has come up. In the following example, 2 x SMLTs went down and
came up:
CPU5 [06/05/08 05:05:45] MLT INFO SMLT MAC/ARP Sync Requested: CAUTION do not take ANY action with
the peer at this time
CPU5 [06/05/08 05:05:45] MLT INFO SMLT MAC/ARP Sync Requested: CAUTION do not take ANY action with
the peer at this time
CPU5 [06/05/08 05:05:46] MLT INFO SMLT MAC /ARP Sync is Complete : Peer can now be used normally
CPU5 [06/05/08 05:05:46] MLT INFO SMLT MAC /ARP Sync is Complete : Peer can now be used normally
NOTE: To determine which specific SMLT IDs are affect, look for the SMLT ID down/up log messages.
Case 3: When sync fails due to difference in IST Peer software version (pre-4.1.8.x and 4.1.8.x) where one peer
supports MAC/ARP sync but the other does not. Or some other potential issue, such as a mis-configuration or
IST Session not coming up. The system that is reset and is requesting sync, it will keep all the ports locked down
(except IST_MLT) until the IST comes up properly and sync has occurred. After 5 minutes the below Log/Error
messages will be displayed:
CPU5 [05/15/08 05:28:51] MLT INFO SMLT MAC/ARP Sync Requested: CAUTION do not take ANY action with
the peer at this time
< After 5 min>
CPU5 [05/15/08 05:33:55] MLT ERROR SMLT initial table sync is delayed or failed. Please check the peer switch
for any partial config errors. All the ports in the switch except IST will remain locked.
NOTE: All known failover times for SMLT/RSMLT operation are now, and always have been sub-second. With
this release all known fail-back or recovery times have been improved, especially for very large scaled
environments to be within 3 seconds, in order to provided required redundancy for converged networks. These
values are for unicast traffic only. Not all IP Multicast failover or fail-back/recovery situations can provide such
times today, as many situations depend on the IPMC protocol recovery. For best IPMC recovery in
SMLT/RSMLT designs, the use of static RPs for PIM-SM is recommended, with the same CLIP IP address
assigned to both Core IST Peers within the Cluster, and to all switches with a full-mesh or square configuration.
Failover or fail-back/recovery times for any situations that involve high-layer protocols can not always be
guaranteed. Reference the Network Design Guide for your specific code release for recommendations on best
practices to achieve best results. In many situations, it is abnormal corner case events for which times are
extended. As well for all best results, VLACP MUST also be used. The SMLT/RSMLT improvements noted here
have been optimized to function always with VLACP. Therefore for best results a pure Nortel SMLT/RSMLT
design is best. We still support SMLT designs with any non-Nortel devices that support some level of link
aggregation, but fail-back/recovery times can not be guaranteed.
NOTE: VLACP configuration should now use values of 500 msec short timer (or higher) and a minimum timeout-
scale of 5. Lower values can be used, but should any VLACP ‘flapping’ occur, the user will need to increased one
or more of the values. These timers have been proven to work for any large scaled environments (12,000 MACs),
and also provide the 3 second recovery time required for converged networks (5 x 500 = 2.5 seconds). Using
NOTE: If using VRRP with SMLT, users are now HIGHLY (MUST) recommended to use unique VRIDs,
especially when scaling VRRP (more than 40 instances). Use of a single VRID for all instances is supported
within the standard, but when such a configuration is used in scaled SMLT designs, instability could be seen. A
[better] alternative method, which allows scaling to maximum number of IP VLANs, is to use RSMLT designs
instead. See Section 10 in this Readme (page 10) for additional information on how to easily move from VRRP
design to RSMLT design.
NOTE: For any SMLT design, for L2 SMLT VLANs, it is now HIGHLY recommended to change the default VLAN
FDB aging timer from its default value of 300 seconds, to now be 1 second higher that the system setting for the
ARP aging timer. FDB timers are set on a per VLAN basis. If using the default system ARP aging time, config ip
arp aging <minutes>, of 360 (minutes) than the proper value for the FDB aging timer, config vlan x fdb-entry
aging-time <seconds>, should be 21601 seconds, which is 360 minutes (6 hours) plus 1 second. This will have
the system only use the ARP aging timer for aging, versus the FDB aging timer. This value has been shown to
work very well to assure no improper SMLT learning. The use of this timer has one potential side-affect. For
legacy module, this limits the system to around a maximum of 12,000 concurrent MACs; for R-mode system, the
limit remains at 64K, even with timer setting. With this timer, should an edge device move, the system will still
immediately re-learn and re-populate the FDB table properly, and not have to wait for the 6 hour (plus 1 second)
timer to expire. No negative operational affects are known when using this timer value. For non-SMLT based
VLANs the default FDB aging timer of 300 maybe used or can be changed or even also set to 21601. For this
reason the default value of the FDB aging timer will remain at 300 (seconds), within all code releases.
AA1419048-E6 1-port 1000Base-SX Small Form Factor Pluggable (SFP) Gigabit Ethernet Transceiver,
connector type: LC. Digital Diagnostic Monitoring Interface
AA1419049-E6 1-port 1000Base-LX Small Form Factor Pluggable (SFP) Gigabit Ethernet Transceiver,
connector type: LC. Digital Diagnostic Monitoring Interface
AA1419050-E6 1-port 1000BaseXD Small Form-factor Pluggable (SFP) Gigabit Ethernet Transceiver -
1310nm. Diagnostic Monitoring Interface
AA1419051-E6 1-port 1000BaseXD Small Form-Factor Pluggable (SFP) Gigabit Ethernet Transceiver -
1550nm. Digital Diagnostic Monitoring Interface
AA1419052-E6 1-port 1000BaseZX Small Form-Factor Pluggable (SFP) Gigabit Ethernet Transceiver 1550nm.
Digital Diagnostic Monitoring Interface
AA1419053-E6 1-port 1000BaseCWDM Small Form Factor Pluggable GBIC (mini-GBIC, connector type: LC) -
1470nm Wavelength, 40km. Diagnostic Monitoring Interface
AA1419054-E6 1-port 1000BaseCWDM Small Form Factor Pluggable GBIC (mini-GBIC, connector type: LC) -
1490nm Wavelength, 40km. Diagnostic Monitoring Interface
AA1419055-E6 1-port 1000BaseCWDM Small Form Factor Pluggable GBIC (mini-GBIC, connector type: LC) -
1510nm Wavelength, 40km. Diagnostic Monitoring Interface
AA1419056-E6 1-port 1000BaseCWDM Small Form Factor Pluggable GBIC (mini-GBIC, connector type: LC) -
1530nm Wavelength, 40km. Diagnostic Monitoring Interface
AA1419057-E6 1-port 1000BaseCWDM Small Form Factor Pluggable GBIC (mini-GBIC, connector type: LC) -
1550nm Wavelength, 40km. Diagnostic Monitoring Interface
AA1419058-E6 1-port 1000BaseCWDM Small Form Factor Pluggable GBIC (mini-GBIC, connector type: LC) -
1570nm Wavelength, 40km. Diagnostic Monitoring Interface
Switch management
Users will now be allowed to enable ssh-pass-auth when the switch is operating is Hsecure mode.
(Q01818955)
Users will now be allowed to access a switch operating in Hsecure mode with JDM after setting the block-
snmp bootconfig flag to false. This value is not currently preserved over a reboot – see the Outstanding
Issues section below for more information. (Q01811342)
Removal of non-operational I/O cards will now be detected by ERS 8600 and both the CLI and JDM will
properly display the card as not present. (Q01862981/ Q01855789)
When hard or soft resets are now initiated from JDM or other SNMP devices, a log message indicating
the reset type will now be generated. These log messages will have format:
(Q01983973)
Disconnecting an SSH session that had initiated a secure file transfer (an unsupported protocol) can no
longer lead to system instability. (Q01856195)
If the verify-config flag is set to true, ERS 8600 no longer defaults the configuration on boot if an R
module fails to initialize or is not present, even though there exists configuration information for that slot.
(Q01865292)
Platform
Port statistics for 8683XLR modules no longer reflect incorrect high values after a port is disabled and re-
enabled. (Q01890883)
Some versions of a new chassis, any chassis with HW Rev field of 50 or above, where coming out of
manufacturing with the HW Config field set with invalid value. This type of chassis would the show invalid
log message errors regarding Slots 1 and 10 (for 8010 or 8010CO chassis only) not being High
Performance slots, when indeed the slots were HP slots. Loading 4.1.8.2 or higher code into such a
chassis will correctly reprogram the affect field and the chassis will no longer report the invalid error log
messages. (Q01950243-01)
ERS8600 no longer mirrors traffic to the mirroring port when the configuration related to port mirroring is
disabled or deleted. (Q01849168)
ACE filters that match on an IP protocol and have subsequent ACE filters that match on source or
destination IP will now function properly after the switch is rebooted. (Q01814530)
ERS8600 operating in super-mezz mode will now recognize the PCMCIA card properly when the
PCMCIA card is removed and re-inserted without issuing a PCMCIA-stop command before removal, as
well as after initial insertion of the PCMCIA card when the switch was booted without a PCMCIA card.
(Q01907447)
When adding VLANs to a MLT/SMLT with POS ports in it, the STP state will no longer be toggle, which in
the past would cause the SMLT state to also then go down. (Q01974865)
Configuring a VLAN or BRouter port with an IP address space that overlaps an already existing Out-of-
band Management port static route, will no longer cause system instability. Please also reference CR
Q01987429 in the list of Known Issues for some additional information regarding this area of operation.
(Q01974397)
CPU modules are no longer polled for parity errors, as the poll result inaccurately reflected an error
condition. This operation is associated with the detection of FAD / SWIP errors (ER Q01505098 – see
4.1.6.0 Readme). (Q01910296)
A request for statistics on a port which is part of a VLAN on which an ACL is applied and when that port
or a port in the same slot is not specified in the ACE attributes will no longer cause switch connectivity
issues. (Q01865206)
Ping snoop filters will now be properly excluded from the configuration file when a save config is
performed. (Q01895651)
A rare lockup of a data path "lane" on a 8630GBR line card that can occur during a card or switch reboot
has been resolved. This lockup would only occur occasionally when custom queues were configured.
(Q01777369)
The ambient temperature parameter for the new CMHS fans shall now be displayed properly for a system
with these fan types. Release 4.1.8.2 or higher fully supports the new CMHS fans. These fans now ship
with any new chassis, not just for chassis where RS modules are to be deployed. (Q01938086)
FDB entries will no longer incorrectly display the SMLT Remote flag as False/False or True/True on both
the IST pair switches for the same MAC entry. (Q01838871)
Ports RSTP/MSTP related configuration will now be retained after a removal and re-insertion of an I/O
module. (Q01783263/Q01978551)
MLT ports running RSTP no longer experience traffic forwarding issues when individual MLT ports go up
or down. (Q01944595-03, Q01940344)
Legacy module SMLT ports containing 2 or more links configured with RSTP will now properly come up
following a reboot. (Q01943168)
A CPU failover event will no longer incorrectly cause VLACP to bring SMLT ports down. (Q01894048)
ERS8600 no longer displays an error message when a link is brought down which has a static-mcastmac
configured. (Q01881405)
In SMLT environments, rebooting one of the IST peers or toggling the status of SMLT no longer can
cause system instability; this change is associated with SMLT re-architecture. (Q01908107)
VLACP will now converge properly on SMLT ports after HA failover as port locking and unlocking is now
synced properly to the slave CPU. (Q01913866)
MSTP will now properly send BPDUs on HA failover and will no longer cause instability in the network.
(Q01887792)
MSTP will now converge properly when it contains ports that are not part of the CIST instance.
(Q01921984)
IP Unicast
ERS8600 now forwards traffic ingressing on an MLT port when Reverse-Path-Check is enabled in strict
mode. (Q01859755)
The R module error message “COP-SW ERROR Slot #: ercdSetDefaultRoute: rcdRspMalloc failed” that
was being generated during default route updates has been resolved and no longer causes system
instability. (Q01908628-02)
ERS8600 RSMLT edge support now recovers properly when the last active port in any RSMLT VLAN is
bounced. (Q01953415-02)
BGP
When a route-policy is applied to match a particular network and a BGP neighbor is restarted, the "show
ip bgp neighbor advertise-route x.x.x.x" command will now display only the routes that are advertised to
the BGP Peer. (Q01879357)
After deleting a BGP aggregate address, BGP will no longer incorrectly advertise routes back to the
originating BGP peer. (Q01889887)
Multicast
An ERS8600 with an R-module will no longer become unstable when excessive multicast control packets
are received on that module. (Q01872811)
On an ERS8600 using PIM-SM, the multicast route entries will no longer point to the wrong next hop
when there is a change in the network topology. (Q01907611)
A method to solve the issue of connection ID leakage for IP Multicast has now been provided, This
resolves the issue of failed attempts in creating a connection when creating S,G records, and thereby
previously potentially affecting IP Multicast operation. (Q01906890)
8. Outstanding Issues
Enabling of the multicast flooding feature (config ip arp multicast-mac-flooding enable) does not sync to
the slave when the ERS8600 is operating in HA mode. (Q01942511)
SNMP/JDM connectivity is lost after ERS8600 is reset with hsecure flag is set to true (enabled) and block-
snmp flag set to false. To correct, go back and set the block-snmp flag to false. In a future release,
hsecure operation will be modified. (Q01811343/ Q01901801)
The QoS value of unicast packets is retained when forwarded to the CP as exception packets. If enough
packets with high QoS setting are received, this could negatively affect CP handling of other packets. In
general, unicast packets being sent to CP is abnormal, and the root cause of that situation should be
investigated and resolved as a first step. (Q01845219)
On an ERS running BGP and OSPF, when BGP routes are redistributed into the OSPF domain and a
route-policy is used to match and permit a prefix, more specific prefixes do not get redistributed into the
OSPF domain. Care must be taken when using such a configuration. (Q01922909)
VRRP global configuration parameters are set to disable (default is enabled) on deleting a configured
prefix list. This will not affect VRRP operation, but will affect ability to ping the VRRP IP address, and for
VRRP trap operation. This situation only happens upon a prefix list delete, and requires a reconfiguration
of VRRP global parameters to currently resolve. (Q01924298)
When an 8600 port is configured for EAPoL and the clients use certificates problems may exist in the
Radius communication. The 8600 does not increment the IDs for its Access Requests. As well the NAS
port type is not set to Ethernet which may cause problems for any Radius policies. It is recommended to
not use EAPoL with client certificates in association with Radius at this time. (Q01986137)
Multicast operation can be adversely affected if PIM is globally toggled from on to off to on, on the switch
which is the RP. It is recommended to not toggle PIM on any switch which may be an active RP for any
streams. (Q01988012)
If a net management route is added to the boot configuration after VLANs have been configured, there is
no check if the destination network already exists local on the ERS8600. This can lead to the VLAN
losing its IP address. Therefore boot configuration programming of OOB management ports and
associated parameters, such as routes, should take place prior to VLAN configuration. If the VLAN
configuration detects a conflict, it will not allow the configuration to take place. Similar checks will be put
in place in a future release to perform similar check when net management routes are configured.
(Q01987429)
Configuring Distributed MLT or MLT on ERS8600 using 8608GBE cards with STP enabled, could lead to
a port within the MLT being put in a different STP state. (Q01877552)
The "show sys info card" CLI command executed for an 8692 CPU card with Mezz Hardware version E2
does not display the proper Mezz Serial number. (Q01921632)
When an 8648GTR module is connected to classic ethernet modules through an MLT, only the first MLT
port added auto negotiates correctly to 100Mbps Full Duplex whereas the subsequent ports added comes
up as 10Mbps Half duplex. (Q01886904)
On an ERS8600 running OSPF, the command “show vlan info ports [vlan-id]” display inadequate space
between the column head VLAN ID and PORT MEMBER when the ports to be displayed are OSPF
passive port members. (Q01927867)
If UDP forwarding is configured on IST switches, the destination subnet will receive two copies of the
original packet, as both IST switches will receive and forward the packet. If the forwarding address is a
subnet broadcast and that VLAN is configured on both of the IST switches, instability may be observed on
the IST link. (Q01936551)
A PIM BSR may experience instability when a large number of RP sets are configured. For large PIM
implementations, it is recommended to use summarization for RP groups and not use /32 masks. A
warning message will now be generated under these circumstances, stating: "BSR message size is high
at XXXX bytes. Summarize your RP Sets to reduce their size. Failure to do this could lead to system
instability.". This message will be displayed when the BSR message size is 1719 bytes or greater. This
situation will not occur in networks with static RP configurations where no BSR is present. (Q01938405)
When MSTP or RSTP is configured, an SNMP get-next on any MIBs in the tree: 1.3.6.1.2.1.17.1.4.1
(iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1). dot1dBridge(17). dot1dBase(1).
dot1dBasePortTable(4).dot1dBasePortEntry(1)) will return the same OID as the request, potentially
resulting in high CPU utilization. (Q01942480).
The PCMCIA card may become inaccessible and the following error may be shown:
0x53e7ab0 (tLoggerTask): disk cache error: device fe21488 block 57 errnoc0003, disk write failed, data
loss may have occurred.
This error is most likely caused by the switch not running the latest DOSFS code. Workaround: 1) backup
the files from the DOSFS device 2) reformat the DOSFS device with Release 5.0 or later (use the dos-
format command) 3) reinstall the files on the DOSFS device. (Q01986665)
9. Known Limitations
Broadcast and multicast rate limiting may occasionally cause packets to be dropped when traffic levels
are below the configured rate limit when configured on legacy modules. (Q01871916).
The event of discontinuing logging to PCMCIA by the executing the CLI command pcmcia-stop is not
logged into the log file. (Q01774929).
When VLACP is configured, the log message “LACP WARNING Received MAC-mismatched PDUs on
port <port number>, MAC <mac address>, Please check your VLACP configuration.” is sometimes
observed. In the event of a VLACP misconfiguration, this message will be logged continuously in the log
ERS8600 could take a minimum of about 10 seconds to populate an OSPF learned route into the Route
Table Manager as it does not rebuild its router LSAs immediately when the neighbor router changes to
FULL state. (Q01848350)
A “save config” executed from the standby CPU will result in the pcap.cfg data replacing the configuration
data stored in config.cfg on the standby CPU. Changes to the standby CPU configuration should ONLY
be executed from the master CPU, via either “save config” (savetostandby flag set true or “save config
standby <config file name>”. (Q01937023)
SLT configurations where the SLT port and the IST port are configured on the same physical module
(non-best practice design) can experience FDB entry learning issues for MAC addresses learned across
the IST, which can cause connectivity loss. This condition can occur if the module is physically swapped
out during switch operation, or if the module is disabled/enabled via CLI or JDM. All FDB entries will be
relearned after the fdb-ageout time, or can be manually relearned by performing a fdb-entry flush on the
relevant VLANs. (Q01926665)
On an ERS8600 running in SMLT environment using E modules, if the number of ARP and FDB table
entries exceeds 7500, the ARP table entries may experience intermittent corruption when the
corresponding FDB table entries age out. (Q01904966/Q01869054)
On an ERS8600 running VLACP, if the value of VLACP timer is not set to a multiple of 10, VLACP may
not function properly because the VLACP port may not be able to send out any VLACP PDUs. VLACP
timers must always be set to some multiple of 10. (Q01932414)
When multiple ATM PVCs are configured on a port and a static route is configured where the ATM
interface is the next hop, the static route will not be removed from the routing table when a PVC goes
down as detected by F5-OAM. The static route will only be removed when the ARP entry ages out. For a
single PVC configuration, the static route will be removed as the ATM port will go down. (Q01952948)
Please also see Known Limitations Section of the Release Notes for Ethernet Routing Switch 8600
Software Release 4.1.1.0.
Please note the following in regards to mixed module (R/RS and classic E/M) MLT support:
Mixed module MLTs consisting of R and RS module ports and classic E and M module ports will work together
and is fully supported only for common features that function for both types of modules. Many functions and
parameters must be set at the individual port level within the MLT. VLAN assignment, tagging (802.1d) status,
and Spanning Tree Protocol (STP) are examples of functions that are configured at the MLT level and not at the
port level. If a parameter is only available on a subset of the MLT ports, than the use of this parameter is not
supported in a mixed module MLT, and with such use inconsistent behavior can occur. Speed and duplex setting
are examples of port level parameters that are supported on all types of modules, and therefore can always be
used. Note that common port level parameters or functions must always be configured to be the same for all
ports within the MLT. Multicast and broadcast rate limiting is a feature available on both port types, but it operates
differently depending on the module type. Therefore, Nortel recommends not to use this function, as it could lead
to inconsistent or unknown behavior. Egress queue size is a parameter that is only available with R and RS
modules and should not to be used in a mixed module MLT, as the parameter cannot be applied to the E and M
module ports. You need to use caution when using filters in a mixed module MLT. Filter operation can differ
There is little to no software control or checking for mixed module MLT configuration. Before configuring a mixed
module MLT, you should address any questions or concerns to Nortel prior to implementation.
Copyright © 2009 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: 19 November 2008
Purpose: Software maintenance release to address software issues found both in the field and internally.
.
None.
3. Platforms Supported
All Ethernet Routing Switch 8600 modules are supported in the 8006, 8010, and 8010co Chassis. Full slot
support for all modules may be dependant on the presence of the High Performance Backplane. Reference
4.1.1.0 RN document below for further details.
Please refer to the following documents for details on the Platforms Supported:
Release Notes for the Ethernet Routing Switch 8600 Series Switch Software Release 4.1.1.0 (Part No.
317177-E)
Installing Ethernet Routing Switch 8600 Switch Modules (Part No. 312749-K Rev 01)
Managing Platform Operations Ethernet Routing Switch 8000 Series Software Release 4.1 (Part No.
315545-E Rev 00)
Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis (Part No. 316314-F Rev 01)
Note: R-series modules are supported in the 8010co chassis with a High Performance Backplane. Please see
ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
p80a4172.mib MIB
3329497
p80a4172.mib.zip MIB (zip file)
533346
p80a4172.md5 md5 checksum file
1442
p80p4172.dld 8600 POS module image
701771
p80t4172.dld 8600 ATM module image
906024
8600 image for the SuperMezz
8873804
p80m4172.img card
Firmware images
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR (only applies to
2284578
8630GBR modules)
SSL Images
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.9.0 or higher.
This software release supports the Web Switching Module (WSM) release WebOS 10.0.34.0. This code is found
on Nortel web site under Content Networking -> Web Switches -> Ethernet Routing Switch Web Switch Module.
This software release supports SDM FW Release 2.3.7.0. This code is found on Nortel web site under Security &
VPN -> Service Delivery Module 8660.
This software release supports SDM TPS Release 4.7. This code is found on Nortel web site under Security &
VPN -> Service Delivery Module 8660.
To download these code releases may require valid Nortel support web access.
IP Unicast
An ARP processing situation, introduced in the 4.1.6.0 release, that could lead to system instability has
been resolved in this release. Customers experiencing system instability with code releases starting with
4.1.6.0 and up to and including 4.1.7.1 should move to this code release. Customers may want to
consider a pro-active approach of moving to 4.1.7.2 depending upon their current network operation and
code release. This change is the only change between 4.1.7.2 and 4.1.7.1. (Q01923361, Q01925711)
8. Outstanding Issues
Refer to the 4.1.7.1 Release Notes below.
9. Known Limitations
Refer to the 4.1.7.1 Release Notes below.
The CLI command "config sys set reset-passwd snmp-community-strings" is now obsolete and no longer
valid. The documentation in Configuration and Managing Security for ERS8600 regarding this command
is no longer valid. (Q01923596)
Copyright © 2008 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: 02 Sep 2008
Purpose: Software maintenance release to address software issues found both in the field and internally.
3. Platforms Supported
All Ethernet Routing Switch 8600 modules are supported in the 8006, 8010, and 8010co Chassis. Full slot
support for all modules may be dependant on the presence of the High Performance Backplane. Reference
4.1.1.0 RN document below for further details.
Please refer to the following documents for details on the Platforms Supported:
Release Notes for the Ethernet Routing Switch 8600 Series Switch Software Release 4.1.1.0 (Part No.
317177-E)
Installing Ethernet Routing Switch 8600 Switch Modules (Part No. 312749-K Rev 01)
Managing Platform Operations Ethernet Routing Switch 8000 Series Software Release 4.1 (Part No.
315545-E Rev 00)
Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis (Part No. 316314-F Rev 01)
Note: R-series modules are supported in the 8010co chassis with a High Performance Backplane. Please see
ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
p80a4171.mib MIB
3329497
p80a4171.mib.zip MIB (zip file)
533346
p80a4171.md5 md5 checksum file
1442
p80p4171.dld 8600 POS module image
701771
p80t4171.dld 8600 ATM module image
906024
8600 image for the SuperMezz
8873615
p80m4171.img card
Firmware images
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR (only applies to
2284578
8630GBR modules)
SSL Images
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.9.0 or higher.
This software release supports the Web Switching Module (WSM) release WebOS 10.0.34.0. This code is found
on Nortel web site under Content Networking -> Web Switches -> Ethernet Routing Switch Web Switch Module.
This software release supports SDM FW Release 2.3.7.0. This code is found on Nortel web site under Security &
VPN -> Service Delivery Module 8660.
This software release supports SDM TPS Release 4.7. This code is found on Nortel web site under Security &
VPN -> Service Delivery Module 8660.
To download these code releases may require valid Nortel support web access.
Switch management
If a DNS server is configured on the switch and a user does a cut/paste of commands into a telnet
session, all the commands within the cut/paste will now be executed properly. (Q01784202)
Platform
Garbage characters ingressing the console port at a high rate of speed will no longer result in system
instability. (Q01825851)
When a SuperMezz card is enabled and excessive traffic destined to an unknown host is sent to an in-
band VLAN, and there is also a condition of continuous SNMP requests to the switch, the switch will no
longer become unstable. (Q01802463)
A manufacturing issue was identified on some 8005AC power supplies in which the power supply was
incorrectly programmed. This lead to all prior versions of software to not properly recognize these power
supplies. This recognition issue would cause the power supply output power to be defaulted to 690W in
system power calculations, as the power supply will show as 'not recognized'. Other than this the power
supply will function 100% properly. This lower output power calculation could potentially lead to modules
not coming online in a highly populated chassis. This release of software corrects this issue and properly
recognizes the power supply and applies the correct output power to the system power calculations.
(Q01920749)
For Classic modules, if both enable-diffserv and access-diffserv are enabled on a mirrored port, users will
no longer be able to create a port mirror with mode Tx or Both, just Rx. Previously this mirror
configuration was allowed but resulted in potentially corrupted mirrored packets. (Q01744991)
SMLT links configured with VLACP will no longer be intermittently disabled by VLACP after an HA
failover. This situation was seen only after a chassis power cycle, or reset of both SSF/CPUs at the same
time, AND then a follow-on HA failover. If your system gets into this situation, with an older release of
code, a global disable/enable of vlacp (config vlacp dis, then config vlacp en) will rectify the situation. In
order to prevent future failures, after any system/chassis power cycle a reset of the stand-by SSF/CPU,
would be recommended, and will then alleviate the issue from returning. At the same time, because this
only occurs with SMLT ports, even if this situation did occur the SMLT peer will continue to stay up and
run the network without interruption. (Q01913866/Q01894048-03)
On ERS 8600 when port mirroring is configured on R modules, the Tx frames will now be mirrored
properly for mirroring mode Tx or Both. (Q01842897)
When a faulty secondary SSF/CPU is present in a chassis, the Master SSF/CPU will no longer
continuously attempt to bring the faulty SSF/CPU online, potentially causing high CPU utilization.
(Q01869443-03)
Layer 2 switching
Performing a CPU failover on one peer switch within and SMLT pair no longer causes system instability
on the other IST Peer switch due to improper handling within the ARP delete functionality. (Q01907052)
IP Unicast
When viewing the IP -> Policy -> ApplyPolicy tab for the ERS 8600 via Device Manager, the fields
RoutePolicyApply, RedistributeApply, and OSPFInFilterApply are now unchecked by default. This now
matches pre-4.1.x behavior. There is no reason to have every Policy type checked by default, as the
user needs to select (check) the type of policy they wish to apply by using the apply button associated
with this screen. Users should be aware that 4.1.7.1 and above will not function differently than previous
4.1.x releases in how this DM screen functions. Please also note the 4.1 based IP Routing manual will
not be updated and therefore page 639 shows the pre-4.1.7.1 behavior, not the new 4.1.7.1 behavior.
This change has no other functional or operational change. (Q01834790)
When a DHCP/BootP server is connected to a VLAN that is in VRRP backup state and a client is
connected to a VLAN on a different 8600 in VRRP master state, the DHCP/BootP replies will now be
forwarded. Previously in such a configuration the packets were only forwarded by the switch in VRRP
backup state when VRRP backup master was also enabled. (Q01848171)
ERS8600 in an SMLT environment will no longer become unstable with certain traffic patterns also
involving a large number of ARP records. This situation is detailed in CSB 2008008980, which was also
fixed in 4.1.6.3 code. The 4.1.7.1 release has this 4.1.6.3 change included. (Q01862845)
OSPF
When ERS 8600 receives an invalid LSA, it will now send out a BadLSReq which will bring down the
neighbor relationship with the router sending the invalid LSA. (Q01837492)
OSPF routes with a next hop corresponding to the IP address of the RSMLT Peer will no longer be
removed from the route table if the IST_MLT is toggled. (Q01894652)
BGP
In a BGP configuration with a hold-timer of less than 5 seconds and a keepalive-timer of less than 2
seconds, insertion of an R module will no longer cause a loss of BGP peers. (Q01825956)
BGP input policies are now properly applied when a soft-restart is performed. (Q01939163)
Multicast
If an IP prefix list is created via JDM or CLI with a name that contains spaces, and it is used for
configuring an IGMP access control entry, a reboot will no longer cause the configuration to be lost.
(Q01829843)
When multiple IGMP access control lists are configured on a brouter port, the configuration is no longer
lost upon switch reset. (Q01829919)
For PIM over SLT (single link SMLT) configuration, multicast traffic is no longer lost when one of the SLT
links is disconnected. (Q01836125)
For SMLT triangle configurations in which the edge box is running IPMC (PIM-SM), the IST peer switch
with the lower IP address will no longer stop forwarding traffic downstream upon receiving traffic from the
upstream edge router. (Q01890745)
IPX
ERS 8600 will no longer route IPX packets with a broadcast destination MAC unless the packet type is
RIP/SAP. (Q01749446)
8. Outstanding Issues
The CLI command "show vlan info fdb-entry" can display MAC entries where the SMLT remote parameter
indicates either both true or both false for the same MAC entry on each peer IST switch. This condition
has not been seen to create any traffic passing issues. (Q01838871)
When port mirroring is configured on a classic port with RxFilter mode and an ingress filter with an action
of mirror is also applied to that same port, packets are still mirrored when port mirroring is disabled. The
workaround is to disable both port mirroring and the ingress filter action of mirror. (Q01849168)
When attempting to perform a secure file transfer (an unsupported protocol) from within an SSH session
the 8600 will be unstable after leaving the SSH session. Users should not perform unsupported secure
file transfers. (Q01856195)
Module information is incorrectly displayed in CLI and Device Manager after a faulty R module has been
removed from the chassis. (Q01855789, Q01862981)
If Reverse Path Check is enabled in strict mode for a VLAN or Brouter port, traffic ingressing on an MLT
will not properly be forwarded. For now RPC should not be used if the VLAN or Brouter port is associated
with an MLT. This applies only to R-modules as RPC is an R-module only feature. (Q01859755)
For 8630GBR modules, port mirroring does not mirror Tx traffic if the 3DES file is loaded. (Q01842007)
If the login password is changed via Device Manager, the new password will not authenticate on the
WSM card. The workaround is to change the password via the CLI. (Q01867943)
Displaying ACL/ACE statistics via CLI or JDM for an advanced filter that is applied on a VLAN with ports
on different physical modules can sometimes result in high CPU utilization, and slow network
management responsiveness. (Q01865206)
OSPF may lose adjacencies when a file is transferred to /flash memory via the management port and
there is not enough space within the /flash memory. (Q01870315)
If the verify-config flag is set to true, the ERS 8600 defaults the config (verify fails) on boot if an R module
fails to initialize or is pulled out. To not see this behavior, verify-config flag may need to be set to false
(disabled). (Q01865292)
In a RSMLT set-up where the peer core switches both have a Mezz card, there is a loss of connectivity if
the core switch which matches the real default gateway IP address is reset. This situation is not seen in
configurations with no Mezz card present. (Q01864544)
A poorly worded error message is displayed when attempting to configure the port speed to 1000M with
auto-neg disabled on an 8648 GTR module. This setting is not allowed per IEEE 802.3ab standard. In a
future release the message will be improved. (Q01849911)
If a save config to standby fails due to a problem accessing its flash, CPU messages, such as OSPF
hellos, may not be sent during the save attempt. (Q01827936)
9. Known Limitations
Enabling trace level 9 with option "screen on" for a console session may cause IST/OSPF/VRRP
transitions under heavy CPU traffic conditions. This is not observed when the "screen on" option is not
enabled. Tracing with screen option on is never recommended in production networks. (Q01852005)
When an I/O module is inserted/removed from a chassis, VRRP transitions may be seen, if the VRRP fast
advertisement interval has a value of 400ms or below. These transitions can be ignored and
acknowledged after the I/O maintenance activity is completed. (Q01838155)
ERS 8600 may take around 10 seconds to populate an OSPF route into the routing table after it forms full
adjacency with its neighbors. This is the behavior for all code streams, including all older streams, such
as 3.x. (Q01848350)
On R modules a mismatch in the duplex settings may cause improper traffic flows. Users are warned
against improper auto-negotiation settings, which can lead to this behavior. Reference CSB 2008008723.
(Q01804243)
During HA failover running MSTP with default timers, BPDUs are not sent for a long enough period of
time that other MSTP switches can become root bridge, resulting in a loop in the network. This issue is
not seen if the hello timer value is set to minimum of 6 sec and MaxAge to a minimum of 20.
(Q01875995)
In an SMLT set-up with classic modules in non-M mode, if more than 8000 MAC and 8000 ARP entries
are sent to a core switch, there may be a possibility of the SMLT peer ARP entry getting removed from
the ARP table, as the forwarding table could be full. This situation needs many more addresses to be
seen in either M-mode or R-mode. (Q01894730)
Please also see Known Limitations Section of the Release Notes for Ethernet Routing Switch 8600
Software Release 4.1.1.0.
Although the ERS8600 supports 802.1w (RSTP), the product does not completely confirm to the final
standard, only the original draft standard. (Q01875995)
rcPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies a port.
This value is similar to ifIndex in MIB2."
::= { rcPortEntry 1 }
rcPortType OBJECT-TYPE
SYNTAX INTEGER {
other(0), -- no port installed
rc100BaseTX(1), -- (cat 5)
rc100BaseT2(2), -- (cat 3)
rc100BaseF(3), -- (100 mbps fiber)
rc1000BaseF(4), -- (1000 mbps fiber)
rc1000BaseDualF(5), -- (fiber - dual connector)
rc10BaseF(6), -- (10 mbps fiber)
rcPosMMF(7), -- (multi mode fiber)
rcPosSMF(8), -- (single mode fiber)
rcAtm(9), -- (oc3, oc12, ds3, e3)
rcGbicLx(10), -- (gigabit long haul)
rcGbicSx(11), -- (gigabit short haul)
rcGbicXd(12), -- (gigabit extended distance)
rcGbicCu(13), -- (gigabit copper)
rcGbicOther(14), -- (gigabit other)
rcOc3cSM(15), -- (OC-3c SM)
rcOc3cMM(16), -- (OC-3c MM)
rcOc3cCOPPER(17), -- (OC-3c COPPER)
rcOc12cSM(18), -- (OC-12c SM)
rcOc12cMM(19), -- (OC-12c MM)
rcDs3(20), -- (Ds3)
rcE3(21), -- (E3)
rcGbicNone(22), -- (Gbic card feature)
rc1000BaseT(23), -- (1000 base copper)
rcGbicZx(24), -- (gigabit very extended distance)
rcOc3cAtmSM(25), -- (Atm OC-3c SM)
rcOc3cAtmMM(26), -- (Atm OC-3c MM)
rcOc12cAtmSM(27), -- (Atm OC-12c SM)
rcOc12cAtmMM(28), -- (Atm OC-12c MM)
rcOc3cPosSM(29), -- (Pos OC-3c SM)
rcOc3cPosMM(30), -- (Pos OC-3c MM)
rcOc12cPosSM(31), -- (Pos OC-12c SM)
rcOc12cPosMM(32), -- (Pos OC-12c MM)
rcGbic1470(33), -- (gigabit wavelength 1470)
rcGbic1490(34), -- (gigabit wavelength 1490)
Copyright © 2008 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: 26 March, 2008
Purpose: Software maintenance release to address software issues found both in the field and internally.
The new VLACP Global parameters have NOT been added into this release. The addition of these new
parameters is still scheduled for a future release.
In a chassis with all R-modules (most likely R-mode enabled) the following flags will not have no affect
as these parameters are specific to legacy modules and therefore should always be set to false or
disabled:
It is also suggested that for best operation that these flags are disabled (set to false) in any mixed chassis
that has R-modules present.
The smltRemote log message introduced with release 4.1.5.4, has been changed into a trace message and
will not be generated with this code release. Therefore the use of msg-control function to suppress these
messages is no longer needed. (Q01745278)
3. Platforms Supported
All Ethernet Routing Switch 8600 modules are supported in the 8006, 8010, and 8010co Chassis. Full slot
support for all modules maybe dependant on the presence of the High Performance Backplane. Reference
4.1.1.0 RN document below for further details.
Please refer to the following documents for details on the Platforms Supported:
Note: R-series modules are now supported in the 8010co chassis with a High Performance Backplane. Please
see ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
p80a4160.mib MIB
3328560
p80a4160.mib.zip MIB (zip file)
533162
p80a4160.md5 md5 checksum file
1489
p80p4160.dld 8600 POS module image
701771
p80t4160.dld 8600 ATM module image
906024
8600 image for the SuperMezz
8872035
p80m4160.img card
Firmware images
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR (only applies to 2284578
6. Compatibility
This software release supports the Web Switching Module (WSM) release WebOS 10.0.34.0. This code is found
on Nortel web site under Content Networking -> Web Switches -> Ethernet Routing Switch Web Switch Module.
This software release supports SDM FW Release 2.3.7.0. This code is found on Nortel web site under Security &
VPN -> Service Delivery Module 8660.
This software release supports SDM TPS Release 4.7. This code is found on Nortel web site under Security &
VPN -> Service Delivery Module 8660.
To download these code releases may require valid Nortel support web access.
Configuration of greater than 8 ports in a LACP enabled MLT (MLT with aggregate enabled; LAG) is now
permitted. This is not permitted for a ‘normal’ MLT, where 8 static ports are still the maximum allowed. For any
LAG configuration, 8 of the ports will always attempt to be active, while any additional ports will work as standby
links. The standby links will become active ports in the LAG if any active link goes down, thereby providing
bandwidth redundancy for the LAG. There is no configuration support on the ERS8600 for standby links with any
configuration of 8 or less ports. If the far-end device does support standby link configuration with less than 8
ports, the ERS8600 will also now recognize remote ports that are in standby state, and place its appropriate ports
in standby state as well. (Q01767527).
Support for link priority (config eth slot/port lacp port-priority) is NOT supported. Therefore one can not ‘force’ a
port from active to standby, or vice-a verse, via setting port-priority for the individual ports within the LAG.
The log messages associated with Ext-CP Limit have been changed. The new messages are:
CPU5 [03/12/08 15:48:57] SW INFO SysOp remain congested for 5024ms. Total rxDrop = 2724216, qDepth = 0
CPU5 [03/12/08 15:48:57] SW INFO Ports from Soft down List are causing congestion. starting port monitoring
The congested time (milliseconds) should approximate to the configured system minimum congestion timer
(config sys ext-cp-limit min-congestion-time). The default value for this system timer is 3000 milliseconds. Total
rxDrop will indicate how many packets have been dropped due to the congestion. Note that at this time, this
parameter display may be inaccurate (CR Q01845752). This situation will be addressed in a future release.
Right now the exact and actual number of packet drops is not as significant as the indication that it is packet
drops causing the congestion, versus abnormal queuing. A non-zero qDepth value would be an indication that
excess queuing was the cause of the congestion, as either situation can trigger the congestion mechanism to be
run.
The 2nd log message is stating the monitoring of Soft Down ports will now start. It should also state that all ports
configured as Hard Down enabled will now be disabled. This message will be enhanced in a future code release
to state:
"SW INFO Ports from Hard Down List will now be disabled due to SysOp congestion. System will also now
starting port monitoring of the Soft Down List."
where, xx% is the average port utilization for the slot/port in question, and t = the configured port-congestion-time
(config sys ext-cp-limit port-congestion-time) configured in seconds. The default system port congestion timer is 5
seconds.
This message will only be displayed for ports that actually get disabled by Ext-CP Limit, and have been
configured for Soft Down operation. Therefore the above message will also be associated with an existing
message of the format:
CPU5 [03/12/08 15:49:02] SNMP INFO Link Down (4/19) due to ext-cp limit
For any configured Soft Down port to be disabled by Ext-CP Limit, the port utilization must exceed the configured
port level value for threshold utilization rate (config eth slot/port ext-cp-limit SoftDown [threshold-util-rate]). The
default threshold utilization rate is 50%, and valid parameter values are any utilization value between 1 and 100.
Switch management
The definition for 10Gbps is now added in rcPortAdminSpeed Mib. Therefore a MIB query for port
operational speed will now correctly show 10000 (Mbps) for a 10G port. (Q01780945)
Radius accounting now shows correct value of input/output packets for a telnet session to any in-band
interface address. The number of output packets is still shown as zero for a telnet session to the
management port; this is a HW limitation. Also now SNMP-v2 accounting will properly display Client IP-
address, while SNMP-v3 accounting will now display the proper name of SNMP user. (Q01759830)
In the ERS 8600 topology table the name for ERS4500 series switches will now be properly displayed.
(Q01798277)
Users will now be able to connect to ERS 8600 using Secure Copy (SCP) when an access policy with
access-level rwa and access-strict is true are also configured. Previously SSH worked, but SCP did not.
(Q01767930)
Changing the Management Port bootp status to enable or disable from JDM will no longer cause
management connectivity to be lost, via the Management Port. (Q01746388)
The ERS 8600 Management IP now does reply to ping if the ICMP packet is marked with DSCP value of
AF11. Previously this did not occur. (Q01782522)
Platform
When a CPU card is present only in slot 6, the tapmux parity error counters (feature introduced in 4.1.5.4
code – ER 1505098) are no longer incremented for non-faulty cards. (Q01807020)
Traffic loss could be seen on the mirroring port when the mirroring combination was a legacy port with
any ingress (Rx) mirror function and mirroring port was on 8648GTR module. Therefore users will no
longer be allowed to configure ingress mirroring (any mirror function with Rx) if the mirrored port is a
legacy port and the mirroring port belongs to an 8648GTR module. The solution for ingress/Rx mirroring
of legacy ports in a mixed chassis is to also use a legacy port for the output mirroring port. (Q01790729)
Single Fiber Fault Detection (SFFD) now works properly when an 8630GBR module is connected to an
OM1200/OM1400. This is the only current configuration where SFFD should still be used. In all other
configurations, VLACP should be used. The OM series of switches do not support VLACP. (Q01757462)
When the CPU management port is connected to an Ethernet I/O port and speed and duplex is set to 100
Full on both sides, the management port no longer will lose the speed and duplex setting upon a switch
reboot. (Q01737868)
The link-flap-detect feature is now supported on R-modules just as it has always functioned for legacy
modules. (Q01783494)
With enhance-operational-mode flag enabled and a MLT is configured using any WSM ports, the switch is
no longer unstable when the WSM card is pulled out. (Q01815827)
When using PCAP to capture packets, and a large file is transferred between two hosts, PCAP will now
work properly, and for the next attempt PCAP packets will no longer be dropped. (Q01754856)
When the count of parity errors exceeds the user set threshold the CPU is now reset. (Q01505098-02,
Q01727771)
When the PCMCIA system log file exceeds the configuration limit, a warning message informing the user
about this situation will now be logged into the local log file (show log file), the system log file stored on
the PCMCIA and the message will be transferred to any syslog server as well. The message format is:
SW Warning Warning: THE ALLOWED LOG FILE SIZE HAS EXCEEDED CONFIGURATION LIMITS.
THE FILE SIZE IS CURRENTLY xxxxxxx BYTES!!!!
Additionally if space remains on the PCMCIA card, a new log file with an incremented extension, for
example .001, will be created.
(Q01766905)
Layer 2 switching
A MAC address, for which an fdb-filter is configured, is now displayed in the Forwarding table with type as
“mgmt”. (Q01497977-03)
When RSTP/MSTP mode is enabled, a VLAN will now become unreachable when there are no active
ports present in the VLAN. This is now the same behavior as normal STP. (Q01797033)
With RSTP enabled, the configured path cost of a port which is a member of either a MLT or MLT with
LACP (LAG) will no longer be lost (reset to factory default value) when the port is disabled/enabled or
upon a switch reset. (Q01772097)
All IST packets are now sent with proper QoS for p-bits of 7, and are therefore handled properly even
when diffserv is enabled on the IST MLT ports. (Q01772936)
With RSTP enabled, disabling and re-enabling of STP on an RSTP edge-port will no longer cause any
connectivity issues. (Q01753578)
When classic IP traffic filters are created with redirect next-hop option set to a some external interface,
the ERS8600 will no longer forward traffic to the changed next-hop external interface after the IP Address
of the next-hop device is changed or replaced. In order to get such forwarding, the next-hop filter IP
Address will now need to be re-configured. (Q01774902)
©2009 Nortel (9-Feb-2009) Page 34 of 106
With the CPU utilization being high and a log message being repeated a large number of times the CLI
command “show log file tail” will no longer cause switch instability. (Q01780128)
In an SMLT configuration also using HA, FDB entries are now properly synced on both of the IST Peers
after an HA failover. (Q01790052-01)
For Chassis shipped from year 2003 onwards, the CLI command “show sys info” will now properly display
MacAddrCapacity as 4096k. This additional capacity, also obtained via the MAC Address Upgrade Kit
(DS1411015) for older chassis, is required for VLAN scaling. (Q01723144)
ERS 8600 now no longer sends out SLPP packets tagged with ID of VLANs which have been deleted but
were not removed from the SLPP configuration. (Q01782455)
The "unknown-mac-discard activation enable" command should be executed as the last command of all
port security commands. Otherwise the "unknown-mac-discard" function could be activated with default
parameters. In this instance the ERS8600 port will discard all unknown mac packets, even if autolearn
has been set enabled. This can create communication issues. Normally this is not an issue, except
some users like to copy the output of the "show config" command and paste it into another device’s
console when they setup another device. Previously the "show config" always display "unknown-mac-
discard autolearn enable" after "unknown-mac-discard activation enable", and therefore this caused
activation enable to occur before auto-learn could occur. Now the order of lines of the "show config"
display has the "unknown-mac-discard activation enable" command displayed as the last line of port
security commands. (Q01733255)
MLT/SMLT
In a SMLT set-up where wireless APs are connected off of edge switches, a situation for which the
wireless APs could lose synchronization and reset continuously has now been resolved. This situation
was created by the network design, and some of the SMLT changes introduced in the 4.1.3.0 release, as
this situation were not seen with older releases. (Q01799513)
VLACP operation has now been improved to properly bring down the port under some specific failure
situations not previously covered, so that the traffic fails over to another link of the MLT/SMLT thereby
preventing traffic loss. (Q01752976)
On ERS 8600 the SMLT ID will no longer continue to be displayed under IP->RSMLT tab in JDM, if the
corresponding MLT is deleted. (Q01802676)
IP Unicast
With ECMP enabled, all packets having the same source and destination IP and ingressing on an R
module port will now properly follow the same one route. (Q01745613)
The default route now works properly even after multiple failovers when ERS8600 is operating in HA
mode. (Q01744096)
BGP
While configuring BGP Peers or Peer Groups if multiple words are used in a string, the configuration is no
longer lost upon sourcing the configuration file or upon a switch reset. (Q01773745)
BGP packets will now be sent with DSCP value of 0x30 and TOS value of 0xC0. (Q01726133)
Multicast
In a PIM SSM configuration there is no longer duplicate traffic when the DR switch resets and comes
back, or if there is a local interface on the DR connected to the source which is disabled and enabled.
(Q01783623)
ERS 8600 will no longer be occasionally unstable when PIM is disabled on its IST Peer in an SMLT
based configuration. (Q01760775)
If the IST session should go down, multicast data packet coming in on the IST_MLT physical ports no
longer are forwarded to the CPU, but are instead properly forward by hardware. (Q01772951)
If all the ssm-channels are simultaneously deleted and resulting in many simultaneously leave messages
being sent by the switch, the switch is no longer unstable. (Q01814078)
ERS 8600 is no longer unstable when network load balancing mode is configured as multicast.
(Q01790517)
JDM
RMON history could previously not be displayed for certain configurations; this is now resolved by using
JDM 6.0.9.0 or higher. (Q01755752)
If DNS server is configured on ERS 8600 and a user does a cut/paste of commands onto a telnet session
only the first command within the cut/paste will be executed. (Q01784202)
The pcmcia-stop option is displayed twice in the command list in CLI. This is a minor display issue.
(Q01785465)
When modules are inserted in ERS 8600 chassis, BGP can lose its Peers for approximately 10 seconds.
The situation is seen when the hold-timer is configured less than 5 seconds and keep-alive timer is
configured less than 2 seconds. Please reference CSB 20080087818, under ERS 8600 (CS-LAN).
(Q01825956)
Advanced R-module filter operation may not work as expected after a system reboot, as the order of the
filters may not function properly. This is only seen under some very specific filter combinations. If seen
please contact Nortel support who can provide a temporary work-around to have the filters work as
expected. (Q01814530)
On ERS 8600 in a SMLT set-up when the static route next-hop is disabled and enabled, in some specific
scenario there could be loss in connectivity. (Q01827994)
If an IP prefix list is created via JDM or CLI with a name that contains blanks and it is used for configuring
igmp access control entry, upon a re-boot the configuration will not load properly. For now, it is
recommended not to create IP prefix list name with a blank in the name. (Q01829843)
Protocol packets, such as OSPF hellos or VRRP keep-alives may not be sent out while saving the
configuration file in a dual SSF/CPU system, when the backup SSF has a flash/HW problem and the save
config to standby fails. (Q01827936)
SNMP/JDM connectivity is lost after the hsecure flag is set to true (enabled) and the ERS 8600 is reset,
because setting the hsecure flag to true, currently forces the block-snmp flag to operate as being set true,
regardless of the actual setting. Planned future operation is to allow block-snmp flag to be set to either
Similar to the above documented CR, the ssh-pass-auth system parameter (config sys set ssh pass-auth
<true|false>) can not be set true, when hsecure boot flag is enabled or set true. (Q01818955)
Under some rare conditions, an LACP enabled link that is part of a LAG, but is then determined by LACP
to be non-operational, can form a valid connection to the remote device outside of the LAG if that
connection is based on link status only; this operation can lead to a loop between the original LAG, and
the newly formed link connection. An example would potentially be if LACP for both the local and remote
ports is disabled at the port level. For such an operation, it is recommended to first administratively
disable one of the ports, before disabling LACP on both of the ports. (Q01819762)
ERS 8600 can be unstable when garbage characters are hitting the console port at a high rate and at the
same time the user tries to login to the switch. This situation was seen with a terminal server connection
to a console port, and with improper terminal server configuration. At this time proper configuration of
devices connected to console ports is recommended, but this operation will be enhanced by better
protection in a future (4.1.7.0) release. (Q01825851)
When one of the I/O modules is removed from the IST peer, the number of FDB entries on the master
and slave (requires HA configuration) will not be same. The problem happens only when deletion and
learning of FDB entries are happening simultaneously. (Q01788373-01)
Users are recommended not to create more than 117 legacy destination filters having a destination IP
addresss of 0.0.0.0. If a user create more than 117 of such filters it could result in the IST session going
down and traffic loss. Users can look to use an alternative filter configuration, such as using source IP
filters. (Q01787079)
No event notification is logged in system log-file file when the pcmcia-stop command is executed, as
system logging to the pcmcia has already stopped. Users using the pcmcia-stop command should be
aware of this activity prior to, or when, using this command. (Q01774929)
For PIM, a maximum of 100 candidate RPs should be configured. Configuring more could lead to
improper PIM operation. (Q01797061)
On R modules a mismatch in the duplex settings may cause unidirectional traffic flow. Users are warned
against improper auto-negotiation settings, which can lead to this behavior. Reference CSB 2008008723.
(Q01587376)
In a PIM network having a VLAN extended over multiple switches there could be scenarios where the
incoming port is also displayed in the outgoing port list. However multicast data traffic will not flow out of
the incoming port and there is no functional impact. Also the pruned port may stay in prune pending state
in some specific scenarios. (Q01752755)
Upon enabling IP filters on nearly all the ports of the switch at the same time, the CPU utilization may
reach 100% for couple of minutes and user will not be able to access CLI during this time. It is suggested
not to perform such an operation, but instead to enable filters on port-by-port basis. (Q01776709)
Using custom egress queues, i.e. a queue size greater than 8, traffic shaping can cause traffic to be
dropped on all queues if this custom egress queue receives traffic for more than the configured value.
This problem does not occur when the number of balanced queues is reduced to 10 or below or if the min
and max rate values are changed from their default value of 0/0 for all balanced queues. Either of these
can be used as a workaround, but if using custom queues, it is usual for the min and max rates for the
The SDM FW does not support IP Multicast operation (PIM-SM), nor are there any current future plans for
adding this functionality. (Q01345746)
Under High CPU utilization the CP-limit feature may not always function properly. This is one reason Ext-
CP Limit was introduced. Both CP-Limit and Ext-CP Limit can be enabled on any system at the same
time; these are complimentary functions. (Q01804815)
On ERS 8600 running in STP mode, the ports which were part of non-default STG are not added to
default STG once the switch is reset in RSTP mode. A switch reset to RSTP mode, is best to be re-
configured from default settings. (Q01810281)
When a Passport 15K is connected to ERS 8600 using OC3, the Passport 15K does not detect the loss of
signal when the port is disabled on the ERS 8600. (Q01472705)
Do not mix a Non E-Series legacy 8608SX/GBIC module with an 8630GBR while creating an MLT.
(Q01615420)
Enabling of RSTP on ERS 8600 may cause periodic increase of CPU utilization as compared to normal
STG. However the CPU utilization can be decreased by increasing the hello-time in RSTP configuration.
(Q01800935)
Under RSTP port path cost, a port changes its path cost from the default value of 200000000 to some
value depending upon port speed, which is often determined via auto-negotiation. Now if the port is then
disconnected, the port path cost will not return to the default value, but instead will remain at the last
value associated with last speed. Now if the switch is re-booted, the port’s path cost will now return to the
default value of 200000000. (Q01840692)
Please also see Known Limitations Section of the Release Notes for Ethernet Routing Switch 8600 Software
Release 4.1.1.0.
These ports are open purposely. Although the state is shown as Listen for these ports, no connections
will be accepted on these ports unless that particular daemon is enabled. Ex: Telnet on port 23. We
The CLI command “config bootconfig sio modem 8databits true” sets the number of data bits per byte to
8, while a setting of false sets the number of data bits to 7. The documentation in the user manual
Getting Started (P/N 313189-F, rev 00) states the opposite. False is the default parameter value.
(Q01827281)
The CLI command “rstp ethernet slot/port rstp protocol-migration” can be set to a value of true, but once
set a ‘show info’ for this same command, will display false. This is proper and intended operation. For
further details reference the 802.1w standard regarding ‘mcheck’. (Q01840688)
The following documentation is corrected in “Network Design Guidelines - Ethernet Routing Switch 8600
Software - Release 4.1” (313197-E Rev 00) under section “CP-Limit considerations with SMLT IST”
(Q01819869)
APPENDIX
Copyright © 2008 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: 19 Dec 2007
Purpose: Software maintenance release to address customer found software issues.
Release 4.1.5.4 is a replacement maintenance release for Release 4.1.5.0; Release 4.1.5.0 is no longer web
posted. Reference CSB 2007008059 Rev1 on the Nortel support web site. The one change in Release
4.1.5.4 as compared to 4.1.5.0 is that support for ER 01660093, new Global VLACP parameters, has been
removed. Support for this new functionality is now targeted for Release 4.1.6.0 (end of March, 2008
delivery). Other edits to this readme, versus the original 4.1.5.0 readme, are shown in bold italic lettering.
If upgrading to 4.1.5.4 from any other 4.1.x release besides 4.1.4.0 or any pre-4.1.x release (3.7.x or 3.5.x), then
CR 1596219 still applies, such that the user must reconfigure their OSPF MD5 keys, and save the configuration
afterwards. Reference this CR in the 4.1.4.0 Readme. If upgrading from 4.1.4.0, nothing must be done in regard
to this, if the reconfigure and save steps were previously done.
CR 1617338 still applies, in that a system without a Mezz image present should not be boot with Mezz flag
enabled. Any system without a Mezz image present, even if a Mezz is installed, should have the Mezz flag option
disabled.
IMPORTANT NOTE for SMLT Users: 4.1.5.4 introduced CR 1745278 - smltRemote log message maybe sent
every 10 seconds continuously for edge box base vlan MAC. This message will NOT affect system operation, but
instead of being a log message (sent to both log file and SysLog Server) the message should have been a trace
message, as it was meant for internal debug use only. This will be changed in the next release, but for 4.1.5.4 the
message can be ignored, as again the message has no operational affect. To reduce the amount of messages
sent to the log file and SysLog Server, suppress these SMLT messages with the msg-control feature, via the
following configuration:
Resulting in this:
CPU5 [01/21/08 20:59:19] SW INFO msgControl: messages starting with 'smlt’ suppressed.
For upgrades from pre-4.1.x release (3.7.x or 3.5.x) to 4.1.5.4, the LACP status should be checked (especially if
used) as the global default setting for LACP was changed in 4.1.x based code from prior default setting of
enabled to new default setting of disabled. Please also note in the new feature section, a change to the
VlacpEnable global command.
NOTE: If you are a customer who loaded 4.1.5.0 software and enabled the new Global VLACP parameters, and
you are moving to 4.1.5.4 code, you must first manually edit your configuration file to remove the lines below
#
# VLACP CONFIGURATION
#
3. Platforms Supported
Ethernet Routing Switch 8600 modules in 8003, 8006, 8010, and 8010co chassis.
Please refer to the following documents for details on the Platforms Supported:
Release Notes for the Ethernet Routing Switch 8600 Series Switch Software Release 4.1.1.0 (Part No.
317177-E)
Installing Ethernet Routing Switch 8600 Switch Modules (Part No. 312749-K Rev 01)
Managing Platform Operations Ethernet Routing Switch 8000 Series Software Release 4.1 (Part No.
315545-E Rev 00)
Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis (Part No. 316314-F Rev 01)
Note: R-series modules are now supported in the 8010co chassis with a High Performance Backplane. Please
see ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR (only applies to
2284578
8630GBR modules)
SSL Images
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.6.0
This software release supports the Web Switching Module (WSM) running version WebOS 10.0.34.0
This feature provides the functionality of global fdb-filter for R-modules using the existing CLI command, which
previously was only supported with classic non-R modules. Previously for R-module cards we were achieving this
behavior using the R-module advanced filter commands. Now the global fdb-filter will be applicable to all the I/O
modules in the chassis.
The global fdb-filter command allows the user to selectively add a list of source MAC addresses which the user
wants to discard. This feature also allows configuration of multicast MAC address. User will not be allowed to
configure System MAC, static MAC, learned MAC, STP BPDU MAC, SONMP MAC and an all zero MAC address.
Once a MAC entry is added into global discard list, it cannot be configured statistically or learnt on any VLAN/port.
Alternatively, once a MAC is statically configured or learned, these MACs are not allowed as options for the global
fdb-filter command. No bridging and routing will be performed on any packets from these MAC addresses on any
VLAN. Wild card entry is not supported. The addition of MAC address to the global discard list is done via the
following CLI command:
config fdb fdb-filter add <mac>
This command also allows the user to selectively remove the list of MAC addresses from the global discard list.
Once any MAC Entry is removed from the global discard list, bridging and routing can now be performed on all
packets from this MAC address on any VLAN. The deletion of particular MAC address from the global MAC
discard list is done by the following CLI command:
config fdb fdb-filter remove <mac>
The list of MAC address added to the global MAC discard list is displayed via the following CLI command:
There is existing JDM, CLI and MIB support for this functionality.
This feature was introduced to enable software to detect FAD/SWIP problems based on the parity errors detected
on the 869X SF. When this feature is enabled, and the count of parity errors exceeds the user set threshold,
appropriate action is taken, such as logging an error message, notifying using traps and/or disabling the failed
869XSF (monitor mode). This can be configured on both master and slave CPU.
The following CLI commands have been introduced to support this feature.
config bootconfig parity-errors <enable/disable>
This command enables or disables parity error monitoring.
JDM support is not provided for this feature in this release. The following MIBs have been added for this feature.
The exact MIB definitions are provided in the Appendix section.
rcnTmuxParityError
In the previous software release, there was no option available to advertise the circuitless IP interface in the
topology discovery packets. Topology discovery packet always uses the static management IP address.
This feature when enabled allows an ERS8600 to advertise any one of the configured CLIP IP in the topology
discovery packets.
ERS8600 now provides a configurable option to the user for enabling the provision of choice of topology-ip and
also the instance of the CLIP which will be used. When configuring the choice of CLIP-instance mentioned,
ERS8600 will first check the existence of the corresponding CLIP to be advertised in the topology. If this feature is
not used, the ERS8600 continues to use the current behavior.
The following CLI commands are provided in order to enable this feature.
config sys set force-topology-ip-flag <true/false >
This command is used to enable or disable advertising the CLIP in the topology discovery packets. The default
value is set to false (keeps current prior behavior).
NOTE: The CLI syntax for this command is shown wrong under config sys set info. The current CLI syntax
shows CirclessIpId which is wrong, and such syntax will not be recognized. One must use the syntax noted
JDM support is not provided for this feature in this release. The following MIBs have been added for this feature.
The exact MIB definitions are provided in the Appendix section.
rcChasForceTopologyIpFlagEnable
rcChasCircuitlessIpId
VLACP Global Configuration (ER Q01660093) – Support for this functionality has been
removed.
NOTE: JDM support for VlacpEnable is now re-enabled with Release 4.1.5.4. Changes made to this
variable from JDM will continue to take effect, just as with prior code releases.
Switch management
MIB value for ifSpeed is now displayed correctly for any 10 Gigabit interface.(Q01174158-01)
There will be an explicit message logged when a user makes an unsuccessful log-in attempt using
SSH. (Q01638642)
A user will no longer be able to delete the default SNMP-v3 username configuration. (Q01669001)
The same custom banner created and displayed on the Master will now be displayed correctly on the
Standby/Slave SSF/CPU. As well, disabling or enabling the default banner and adding a custom
banner is no longer allowed on the Standy/Slave SSF/CPU. (Q01669927)
Connecting to the Backup CPU via rlogin no longer causes system instability. (Q01690288)
Inserting a corrupted PCMCIA into an ERS8600 no longer causes system instability. (Q01716404-02,
Q01736713)
Platform
During software upgrade or downgrade the 8683XLR module will no longer intermittently timeout and
will load its configuration properly. (Q01677993)
Ports belonging to an 8648GTR and 8648TXE I/O modules can now be configured in the same MLT.
User is required to set the same speed and interface type on these ports. Proper MLT configuration
from a consistent configuration of all ports in the MLT from a speed and duplex view is the
responsibility of the user, as there is no software check to prevent mis-configuration (Q01670186)
FPGA firmware upgrade of a R-module I/O card can now be upgraded successfully if the I/O card is
present in Slot 10. Previous any FPGA firmware upgrade would fail for modules in slot 10.
(Q01678422)
The port link errors stats are now cleared properly when the counters are reset, via the command
config sys set action resetcounters, or equivalent JDM/SNMP command. (Q01578488)
Upon booting an ERS 8600, the PCMCIA card will now be functional after reboot even when there
are a very large number of messages being transferred to the PCMCIA card (system logfile).
(Q01785442)
Layer 2 switching
MSTP traffic is now forwarded over an interface with forceportstate set to enable, upon a switch
reboot. (Q01673927)
Upon switch reboot ERS 8600 now properly forwards traffic over a MLT which has ports with
spanning tree disabled. (Q01678420)
Traps which are sent out for unknown MAC violation now include the MAC address of the offending
device in all scenarios. (Q01644511)
Under MSTP, when CIST is disabled all MST instances are now also disabled. A User will no longer
be able to enable a MST instance if its associated CIST state is disabled. (Q01742111)
When RSTP/MSTP is enabled for a switch, all spanning tree is now disabled on all Single Port SMLT
(SLT) configurations, which is the proper STP setting for any SMLT edge port. (Q01741831)
When a port with operational status down and STP disabled is added to a MLT in RSTP mode,
packets will no longer loop over the MLT links. (Q01687705)
When a static ARP entry associated with a Multicast MAC is created the packets associated with this
IP address will now go out only on ports configured for the static ARP entry. (Q01645944)
In association with NLB operation, when IP ARP multicast-mac-flooding is enabled and the number of
ports where a multicast MAC packet should be sent out is limited via configuration of static-mcastmac
addresses, the multicast MAC packet received on an IST is now forwarded on other ports.
(Q01637863)
Ports which are brought down due to cp-limit, link-flap, loop-detect or SLPP will now be re-enabled
only after the auto-recovery-delay time expires. Auto recovery timer is a global timer and not specific
to ports and hence there is a possibility that the ports are re-enabled by auto-recovery in less time
than the globally configured auto-recovery-delay time. (Q01731886)
Hardware MAC records on R-modules will now be relearned without an interface reset after the
hardware record was deleted due to any normal process. This operation could have previously led to
improper communication and excess latency. (Q01756726-01, Q01756753-01, Q01735232)
Source and destination classic IP traffic filters with mask value of 1 to 7, which were previously not
supported, will now no longer be allowed to be configured. (Q01628617)
CP limit functionality will now bring down the ports properly when the port receives broadcast or
multicast traffic at rate exceeding the configured values. Also 802.1p broadcast packets with priority 7
are no longer recognized as multicast packets. (Q01717469-02, Q01720807-02)
MLT/SMLT
FDB entries learnt over a non-SMLT link are now properly purged on both of the IST Core peer
switches when the non-SMLT link is brought down. (Q01669984)
Static ARP entry added for a host connected to an IST peer switch will no longer be deleted when the
peer switch looses connectivity to the host. (Q01716187)
If there is an additional MLT in parallel to an IST MLT between a pair of Dual Core IST switches
(unusual configuration), the MAC hardware records now get removed properly once the FDB entry
ages out. (Q01667281)
The designated port of an IST MLT is no longer displayed as “Null” on one of the aggregation
switches. Designated port within an MLT is the port that would handle STP, which is not applicable to
any IST MLT as STP is automatically disabled within such an MLT. (Q01671049)
If the RSTP flag is enabled globally, when an SLT link is broken the SMLT status is no longer
incorrectly displayed as SMLT on both aggregation switches. (Q01666744)
In an SMLT environment with VLACP enabled on any 8608 type [E/M] I/O modules, VLACP now
recovers properly upon HA failover. (Q01766647)
In a scaled SMLT environment, IST no longer flaps as a result of losing SMLT Hello messages when
a very large number of SMLT messages are being exchanged between the IST peers. (Q01776485-
01)
The CLI command "show ip rsmlt info" now will display the SLT id correctly when more than 8 SLT
are assigned to a RSMLT enabled VLAN. (Q01675726)
IP Unicast
ERS 8600 now allows configuration of IP address on a VLAN which has tagged Brouter port as a
member. (Q01666040)
ERS 8600 does not allow the configuration of Brouter IP on an untagged port which is already a
member of an IP enabled VLAN. (Q01666045)
ERS 8600 will now forward all traffic belonging to the same source/destination pair to the same next
hop of an ECMP group. (Q01667206)
IP traffic classic filters will now function properly after a change in port status (up/down/up) or a
reboot; this situation was probably introduced in some 4.1.x code, as this previously work in all 3.7.x
releases. (Q01640420)
Adding and deleting routes continuously no longer causes system instability. (Q01734830)
A few specific situations associated with VRRP GARP packets which could lead to ARP and FDB
entries not being programmed with the correct port information, are now handled properly.
(Q01645567)
IST no longer flaps on receiving packet with an unknown destination address. (Q01762359-02)
On ERS 8600 IPv6 ping now works properly for tagged packets also. (Q01640148)
OSPF
ERS 8600 will now remove Type 5 LSA for cases which require Appendix E processing (RFC 2328),
when the route source is removed. (Q01678901-01)
On ERS 8600 with HA mode enabled, primary and secondary OSPF MD5 keys created on the Vlans
will now be displayed properly even after multiple HA failovers. (Q01593252)
BGP
If two BGP peers have static route for the same network they are learned as alternate routes on the
peer, then these routes are now removed from alternate route if the static route goes down.
(Q01731834)
BGP peers will no longer continue to advertise the static route that has been deleted from both the
BGP peers. (Q01725946)
Multicast
The CLI command “show ip igmp snoop” will now display all the VLANs which have IGMP enabled.
(Q01658847-03)
In a multicast over SMLT set-up, when the RP is present on the Non-DR switch, and data is flowing to
the Non-DR, the hardware records are now timely deleted once the sender stops sending data. The
non-deletion of these records could potentially lead to a hardware resource issue. (Q01674098)
ERS 8600 will now generate a trap when IP mroute resource exceeds the pre-configured values.
Previously only a log message was properly generated. (Q01686594)
IGMP sender's port information will now be updated properly when the sender is moved from one port
to another. (Q01679389)
Using custom egress queues, i.e. a queue size greater than 8, for traffic shaping can cause traffic to
be dropped on all queues if this custom egress queue receives traffic more than the configured value.
This problem does not occur when the number of balanced queues is reduced to 10 or below or if the
min and max rate values are changed from their default value of 0/0 for all balanced queues. Either of
these can be used as a workaround, but if using custom queues, it is usual for the min and max rates
for the balanced queues to be adjusted from default values of 0/0 to start with. (Q01735632)
Connecting CPU management port to an Ethernet I/O port and setting the speed and duplex setting
to 100 Full on both sides causes the management port to come up as 100 Half after a switch reboot.
Changing the bootp status to enable or disable from JDM causes management connectivity to be lost.
However, the same problem is not seen from CLI. Please use CLI as a workaround. (Q01746388)
In an SMLT environment receiving IPv6 traffic, the MAC address of a host connected to the edge box
may incorrectly be programmed to point to the IST port instead of the SMLT port when the Neighbor
goes into stale state. In such a scenario, IPv6 traffic may take long time to recover after failover.
(Q01752114)
Issuing a Control-X while in telnet prompt may reboot the switch. At this time, please do not issue
Control-X within a telnet session. (Q01752502)
When a multicast receiver resides on the same port of a sender, the same interface is shown in the
list of incoming port, outgoing port and prune pending port. Showing as outgoing port is incorrect.
(Q01752755)
When using PCAP to capture packets, and a large file is transferred between two hosts, PCAP will
only function once, and for the next attempt stats will display PCAP packets as being dropped at
hardware. This is due to lack of free buffers on Slave/Standby SSF/CPU. (Q01754856)
Trace Level off option is currently not present in the R-Module trace level commands. In order to turn
off tracing user has to reset the level to zero for each of the modules which previous has trace
enabled (Q01756714-01)
Single Fiber Fault Detection does not work properly when an 8630GBR module is connected to an
OM1200/OM1400. For any other configuration, VLACP should be used instead, if any SFFD issues
are seen. (Q01757462)
Non-DR IPv6 OSPF neighbor remains in incomplete state and never recovers when any one of its
OSPF neighbors is reset. (Q01752119)
When RMON is enabled to gather history statistics and the bucket size requested is greater than 375,
the RMON HISTORY tab under ‘Graph’ in JDM becomes unresponsive after a certain time interval.
(Q01755752)
When using an MSS15k PVG switch with 8600 ATM module with an OC3 MDA, at certain link
utilizations, the InDropPkts starts incrementing followed by F5-OAM mismatches finally resulting in
the PVC’s going down. This is due to delay in the lack of free buffers and the ERS8600 responding to
F5 OAM requests. (Q01497294)
The default route stops functioning after multiple failovers when ERS8600 is operating in HA mode.
Workaround for this is to use more specific static routes than the default route, or else not create
multiple failovers for any HA configuration. Alternatively the switch could be changed to work in non-
HA mode. (Q01744096)
VRRP and OSPF transitions are seen on ERS8600 running PIM-SM when the number of IGMP group
members reaches a high value. Workaround for this issue would be to configure IGMP access control
at the edge (IGMP Proxy enabled) to reduce the number of IGMP messages. Once the number of
IGMP group members is reduced, OSPF and VRRP transitions are no longer seen. (Q01732757)
SMLT/SLT configured on ERS8600 remains in SMLT state, when all the ports from the SMLT/SLT
VLAN are removed. (Q01751343)
ERS8600 depends on some of the IGMP-MIBs which are currently discontinued by RFC 2933.
Workaround for this would be to modify the MIB file in text format and replace the occurrence of
IGMP-MIB with IGMP-STD-MIB. (Q01726908)
The following additional error message is displayed while creating an IP subnet based Vlan with a
non-zero instance in RSTP mode. For example if:
config vlan 10 create byipsubnet-mstprstp x.x.x.x/mask, the following additional error code along with:
Error : Only default instance supported in RSTP mode
Error: Error code not found 74526832 (the additional error message; this message can be ignored)
(Q01775159)
When classic IP traffic filters are created with redirect next-hop option set to a some external
interface, the ERS8600 continues forward traffic to the changed next-hop external interface after the
IP address of the next-hop device is changed or replaced. (Q01774902)
For Advanced ACL (R-module filters) the action of drop for next-hop unreachable when associated
with the re-direct action is not working – packets are still forwarded. (Q01597484)
Radius authentication fails disallowing users from connecting to the switch when an ERS8600 is
booted with a Mezzanine card. (Q01786612)
The amount of IPv6 ICMP errors that is allowed to be sent over the specified interval mentioned by
IPv6 icmp-error-interval is set to 50 by default. With 4.1.x code the user is not allowed to modify this
value as there is neither SW or JDM support for this. Rel 5.0.0.0 will allow user modification to this
value, via a new IPv6 icmp-error-quota parameter addition; this new parameter will also have JDM
support. (Q01348336-01)
Move or Rename operations done on a non-existent source file to an existing destination file causes
the destination file to be deleted. Be careful when using file management commands with existing
files. (Q01791386)
DDI SFPs are currently not recognized by ERS 8600, and will show a status of “unsupported” if
installed in an 8630GBR. Despite this, the SFPs should function fine. (Q01785224)
During an upgrade from 4.0.x release to 4.1.x release the usable flash memory can be upgraded from
16MB/40MB to 64MB. After the flash has been formatted the first command executed related to any
file operation generates Error messages on the console. However, the system recovers automatically
and this does not have any impact on functionality. (Q01681686)
When packets egress out of a mirror port which has diffserv enabled, the data portion of the mirrored
packet maybe corrupted for some interval of time. This situation does not affect the user packets. As
well, if diffserv is set to disabled on the mirror port, the issue is not seen, which is the recommended
choice. (Q01744991)
Multicast packets ingressing on pre-E modules with the multicast MAC set the same as that of the
enabled protocols like RIP, OSPF, VRRP or PIM will cause the CPU utilization to go high.
Workaround for this issue would be to not use the same MAC address which the well-known
protocols use when the switch has any pre-E modules installed. (Q01718994)
When an ERS8600 has learnt more than 2000 FDB and ARP entries and all the entries age out at the
same time, some stale ARP entries may continue to exist in the ARP table. To clear the stale entries
a clear ip arp for all ports or all VLANs command can be used. (Q01732608)
Static routes CAN be configured with VRRP IP address as the next hop IP address. There are no
known limitations with this configuration. The Rev 1 Readme stated that this configuration was not
supported, which was wrong. The actual issue turned out to be a mis-configuration, which caused
traffic to incorrectly hit the CPU, causing high CPU utilization, but no network issues. (Q01735135)
When copying a file from one CPU to another, if the target file already exists user is not prompted if
they would like to overwrite the file or not. This is however the same behavior when a file is copied to
the remote TFTP server from the Switch and the remote CPU is equivalent to a remote TFTP server.
Care should be taken when performing copies so that incorrectly overwriting an existing file does not
occur. (Q01764845)
When LACP is configured on SMLT MLT ports and on rebooting one of the aggregation switches, the
remaining MLT ports on the edge switch can go through STP state transitions which lead to traffic
loss for 30 secs. In order to prevent this it advised to configure smlt-system-id globally, or else to
correctly configure STP disabled at the edge switch. When LACP is used with any SMLT or RSMLT
configuration the use of the smlt-system-id is now always recommended to be used as a best practice
for best results. (Q01692648)
When using ByIPSubnet based VLANs for use with G.729 voice traffic, packet loss has been seen.
Choices are to either change the voice format to G.711 or not to use a ByIPSubnet based VLAN
configuration and instead tag both the port and the user traffic. (Q01745558/Q01759995)
When SMLT is configured with LACP, on booting one of the aggregate switches LACP re-converges
on the other aggregate switch which might cause the Vlan interface to go down for a brief period of
time. In an RSMLT environment, this will cause the RSMLT peer to go down and start the hold-down
timer instead of backing up for the peer. In order to avoid RSMLT re-convergence in such a scenario,
the smlt-system-id needs to be configured. When LACP is used with any SMLT or RSMLT
configuration the use of the smlt-system-id is now always recommended to be used as a best practice
for best results. (Q01764323)
The designated port in a LAG (or MLT) is the one which runs STP. A change to the port status of this
port will cause STP to be re-run, and with default values always, which will cause a traffic loss of 30
seconds. (Q01770793)
For an 8630GBR if a 1000BaseT SFP is inserted, and auto-neg is set to disabled, the port will
always show up (operational status up) even if there is no physical connection. Configuration
of an 1000BaseT port with auto-neg disabled is not a supported configuration per the IEEE
802.3ab standard, but for the 8630GBR and the use of a 1000BaseT SFP we do not guardrail
against this setting, therefore it is up to the user to not use such a configuration. (Q01755512)
The CLI command “config log logToPCMCIA <true/false>” was introduced to stop logging to PCMCIA
gracefully only at runtime/boot. Hence modifications to this command will not be saved across a
reboot. (Q01761564)
Please also see Known Limitations Section of the Release Notes for Ethernet Routing Switch 8600
Software Release 4.1.1.0.
When PIM is enabled on the SMLT IST peer, then on booting the a switch, the switch comes up with
a default static route added with the next-hop as IST peer for first 60 seconds for faster IPMC
forwarding. Therefore as now recommended in the best practice guides, the IST VLAN should have
PIM-SM enabled for any SMLT/R-SMLT configuration that supports L3 IPMC with PIM-SM.
(Q01694222)
For any mention of LX SFP specifications in any documentation, the correct launch power is -9.5 to -
3.0 dBm.
Enabling/Disabling tagging on a port re-enables STP on the port; this is the way the product has
functioned since 3.0 code. (Q01771405)
Layer 3 IPv6 is not supported on IST and [R]SMLT, only L2 IPv6 is supported.
The following documentation is corrected in “Network Design Guidelines - Ethernet Routing Switch
8600 Software - Release 4.1” (313197-E Rev 00) under section “VRRP and other routing protocols”
for “Figure 48 Sharing the same IP address”
In the figure, Router 1’s IP address should be 30.30.30.2 and Router 2’s IP 30.30.30.1 (Q01691202)
A VLAN having both IPv4 and IPv6 address can be associated with more than one Ingress ACL and
Egress ACL. (Q01775850)
rcChasForceTopologyIpFlagEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to enable/disable flag which is used to
set the CLIP-ip as topology ip"
DEFVAL { false }
::= { rcChassis 53 }
rcChasCircuitlessIpId OBJECT-TYPE
SYNTAX INTEGER(1..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Clip-Id set by the user to be used as Topology-ip"
::= { rcChassis 54 }
rcnMcInRecMoreThanThreshold NOTIFICATION-TYPE
STATUS current
DESCRIPTION "An rcnMcInRecMoreThanThreshold signifies that
number of MC Ingress records has exceeded the
configured ingress-threshold."
rcnMcEgRecMoreThanThreshold NOTIFICATION-TYPE
STATUS current
DESCRIPTION "An rcnMcEgRecMoreThanThreshold signifies that
number of MC Egress records has exceeded the
configured Egress-threshold."
Copyright © 2007 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: August 1st, 2007
Purpose: Software maintenance release to address customer found software issues.
Please reference the new version of the 4.1.x.x Upgrade Guide, P/N NN46205-400, for upgrade
instructions.
Please reference the below chart for inter-product SMLT operational support guidelines for any 4.1.x.x
release:
Topologies 8600
Triangle L2 YES
Triangle VRRP YES
Triangle RSMLT YES
Triangle Multicast YES (IGMP at the edge)
3. Platforms Supported
Ethernet Routing Switch 8600 modules in 8003, 8006, 8010, and 8010co chassis.
Please refer to the following documents for details on the Platforms Supported:
Note: R-series modules are now supported in the 8010co chassis with a High Performance Backplane. Please
see ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
p80a4140.mib MIB
3327018
p80a4140.mib.zip MIB (zip file)
532817
p80a4140.md5 md5 checksum file
1489
p80p4140.dld 8600 POS module image
701771
p80t4140.dld 8600 ATM module image
906024
8600 image for the SuperMezz
8850961
p80m4140.img card
Firmware images
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR (only applies to
2284578
8630GBR modules)
SSL Images
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.6.0
RSMLT L2 edge support for Dual IST Core switch failure situation (ER 1277216)
RSMLT implementation does not use a Virtual IP address but instead uses Physical IP addresses for redundancy.
At the same time, RSMLT can be deployed in either L3/routed configurations, or L2/edge configurations, where
previously one might have used VRRP (and back-up master). Now previously, if there was a power outage or
shutdown of both switches within a Dual Core IST pair and for some reason only one switch came back-up,
clients using the powered-off switch’s IP/MAC as their default gateway would lose connectivity to the network. In
such a scenario, even through RSMLT is enabled on the switch it was unable to backup for the Peer as it was
unaware of the Peer’s IP/MAC address. With this new feature, the RSMLT Peer’s IP and MAC addresses are
stored in the config file and will be used upon next reboot, if the IST link does not become active and operational.
Otherwise, the switches will learn from their Peer as normal; see below for additional information.
When the configuration file is saved, if the rsmlt-edge-support flag is enabled and RSMLT peer is UP, the peer IP
address and MAC address is also automatically saved.
NOTE: if the peer information is cleared the switch could stop forwarding for the peer.
After both the Dual Core IST switches have come back-up, and if the IST comes up and is operational, if a
RSMLT Peer enabled message is received from the peer, then normal RSMLT operation is followed. If the peer
has either an IP or MAC change, then a new save config must be performed in order for the new information to be
saved, and RSMLT L2 Edge support to operate correctly.
However, if the IST Peer up message is not received (for example RSMLT is not enabled properly) and the rsmlt-
edge-forward flag is enabled, then first the RSMLT Hold down timer is started to allow routing protocols to
converge; during this time user operation could be affected. Once the hold down timer expires, saved peer
information is picked up and Switch starts to backup for the Peer by adding the previously saved MAC and ARP
records. The Holdup timer is then started and once this timer expires the previously added MAC and ARP records
are deleted and the switch stops backing up for the Peer, as the Peer is not running proper RSMLT for the VLAN.
It should be noted that RSMLT is a per VLAN parameter, and therefore all affects are on a per VLAN basis, not
necessarily per switch.
In L2 Edge support mode the Local values of the HoldDown timer (default value of 60 seconds) and HoldUp timer
(default value of 180 seconds) will be used.
NOTE: this feature is supported only for IP RSMLT Vlan’s and not for IPX RSMLT Vlan’s.
A new command "ip-header-type", had been added under config sys syslog tree. This command can be used to
set the IP header in the Syslog packets to default or circuitless-ip or management-virtual-ip and one of these
choices will be used in the packet.
If the ip-header-type is set to default, then for syslog packets that are transmitted inBand via I/O ports the IP
address of the VLAN will be used. For syslog packets that are transmitted out-of-Band via the management port
the physical IP of the master is used in the IP header. If the ip-header-type is set to management-virtual-ip then
for syslog packets that are transmitted out-of-Band only via the management port the virtual management IP
address of the switch is used in IP header. If the ip-header-type is set to circuitless-ip then for all syslog
messages (inBand or out-of-Band) the circuitless IP address is used in the IP header. If a user has configured
multiple CLIPs, the first CLIP configured will be used.
This enhancement aims at improving the existing SMLT behavior so that better redundancy and resiliency is
achieved in some specific fail-over [actually recovery] cases. Until now, when a Core IST switch boots up, the
closet switch could detect a link up event before SMLT could converge. If the edge started to send data over the
link before the convergence had completed this could lead to some amount of unnecessary traffic loss.
Now, while the switch is coming up all the SMLT ports are kept down until the SMLT protocol converges. The
MAC and PHY are enabled once the SMLT protocol has converged. Proper forwarding records are now
programmed in the I/O hardware before a closet switch starts sending traffic over the link, thereby ensuring sub-
second to no traffic loss. This could cause a complete power cycle of both switches within a DUAL (or larger) IST
Core to take a little longer to pass traffic, but previously any traffic sent from the edge was probably being lost
anyway. In the case of a single switch power-cycle or switch re-boot within the Dual IST Core pair, the other
switch is operational, and therefore the longer time to start forwarding has no user traffic impact.
Switch management
General
The message of the day string now accepts up to 1024 characters which are inclusive of End of Line
characters. (Q01614724)
Any CLI session is now terminated upon link loss on both console and modem serial ports. This includes
if the cable is removed or disconnected. The user would need to reconnect and re-login. (Q01544526-01)
The value of Last Time Sent for RMON events is now displayed correctly via CLI. (Q01617831)
Platform
General
CWDM SFPs are now correctly displayed via CLI or Device Manager. (Q01579140)
Normal software informational log messages will now display the name of the task and some additional
information regarding the task that has been killed. This applies mainly to SF/CPU switchovers in non-HA
configurations, where killing specific tasks is normal operation. (Q01559759)
Egress queue stats are no longer lost upon hot swapping of I/O modules. (Q01587379)
ERS 8600 will no longer be reset when upgrading R-module with any firmware image, if the file name is
missing from the specified path. Instead, if the filename is not present the error message "No such file
exist in flash or pcmcia /flash" would be displayed
If an improper file name is given the following error message will be displayed
[04/11/07 00:31:31] COP-SW ERROR Code=0x10101010 Slot 3: foqUpdate Failed ERROR at or near
XSVF command #1. See line #1 in the XSVF ASCII file"
(Q01583614)
The Temperature alarm LED now changes color on Master and Slave SF/CPU at the same temperature
(now 50 degrees Celsius for both). (Q01596103)
The IST will no longer become unstable when the IP Flow Information Exchange (IPFix) collector
becomes unreachable. (Q01541086)
For classic module hardware port configuration registers could get corrupted in conjunction with SF/CPU
abnormalities, and thereby cause traffic loss. There is now a software check to correct the situation
should it occur. Previously a switch re-boot was required to correct the situation. (Q01585007)
Layer 2 switching
General
Port(s) added to a SVLAN will not get removed from that VLAN after switch reset. (Q01656588)
VLAN 4093 can now be configured only when a WSM module is not present in the chassis, and the
configuration is now saved across a switch reboot. From prior configurations, VLAN 4093 must be deleted
before a WSM module is inserted in the chassis, for the WSM to get properly initialized. (Q01590210)
An IST which is configured in association with an R-module port previously could go down for few
seconds when a gratuitous ARP for a multicast MAC was received. This was seen mainly in NLB
environments, but is now resolved. However in this case the multicast MAC is learnt on IST port on one of
the aggregation switches. Hence that switch will not be able to connect to the server. (Q01547987)
When multiple Access Control List ACEs are simultaneously disabled from Device Manager, multiple
COP software error messages are no longer seen on the console or in the log file. (Q01581660),
Q01581699)
Multiple COP software error messages are no longer seen on the console or in the log file, in association
with NLB configuration. (Q01589048)
When multiple SrcMac based VLAN are created, the information about SrcMac VLAN with lower VlanId
will now be displayed properly. However, the RSP memory limitation still exists. Please refer to known
limitation section for more information. (Q01577517)
When configuring VLACP, the ethertype value is only accepted in hex format. In the configuration file the
ethertype values are now also saved in hex format. For pre-4.1.4.0 code releases the ethertype values
were added in hex format but saved in the configuration file improperly in decimal format. This would
IP Unicast
General
In an RSMLT set-up when one of the Dual Core IST pair switches is reset, all non-local default static
routes, whose next-hop is not reachable, now stays inactive even after a user does an “apply” to a route
policy from Device Manager or CLI. (Q01521914)
OSPF
When OSPF traps are enabled on ERS 8600, the trap messages will now contain the new improved 4.1.x
based information about state transition between OSPF neighbors. This new information was previously
contain in log messages, but was missing from trap messages. (Q01559787)
OSPF MD5 authentication keys now are saved in a non-config type file based on VLAN ID rather than
IfIndex. Prior OSPF MD5 keys will be lost upon an upgrade to 4.1.4.0. Users therefore must reconfigure
their OSPF MD5 keys after an upgrade to 4.1.4.0, and then save the configuration. Please see the newer
version of the Upgrade Guide for proper steps. (Q01596219)
Multicast
The CLI command "show ip igmp snoop" now displays all the Vlans which have IGMP snoop enabled
correctly. Also multicast records for the sender which has stopped sending multicast data will be removed
properly. (Q01658847-01)
On an ERS 8600 NLB packets configured for multicast mode [only] which are to be routed are no longer
dropped by an R module port if the ingress and egress port is the same. (Q01565360)
Radius passwords greater than 20 characters can not be configured or forwarded to RADIUS server.
Future release will add support for 32 character password length. (Q01587270)
MSTP traffic is not forwarded over an interface with forceportstate set to enable, upon a switch reboot.
(Q01673927)
With Device Manager version 6.0.5.0, or any SNMP Manager, a user can delete the default SNMP-v3
username configuration. This action will not be allowed in a future code release. (Q01669001)
There is no explicit message logged when a user makes unsuccessful log-in attempt to an ERS 8600
using SSH. A log message will be added in a future release. (Q01638642)
If RSTP flag is enabled globally, when an SLT link is broken the SMLT status is incorrectly displayed as
SMLT on both aggregation switches. (Q01666744)
The designated port of an IST MLT can be incorrectly displayed as “Null” on one of the aggregation
switches. However this does not have any functional impact. The designated port in an MLT is the port
that would run STP calculations, if required. (Q01671049)
Traps which are sent out for unknown MAC violation do not include the MAC address of the offending
device, when violation-downport and violation-sendAuthenticationTrap are enabled. (Q01644511)
In association with NLB operation, when a static ARP entry associated with a Multicast MAC is created
the packets associated with this IP address may go out on ports that are not configured for the ARP entry.
This will create extra flooding, but should not affect the application being used, but this operation will be
changed in a future release. (Q01645944)
In association with NLB operation, when IP ARP multicast-mac-flooding is enabled and the number of
ports where a multicast MAC packet should be sent out is limited via configuration of static-mcastmac
addresses, the multicast MAC packet received on an IST is not forwarded on other ports. This can
negatively affect NLB operation, and therefore this combination should not currently be used in NLB
environments. (Q01637863)
If the management port is disabled, its IP address is still used for topology advertisement. A configuration
option for topology advertisements will be added in a future release. (Q01654904)
If there is an additional MLT in parallel to an IST between a pair of Dual Core IST switches, the MAC
hardware records may not get removed once the fdb entry ages out. (Q01667281)
ERS 8600 allows configuration of Brouter IP on an untagged port which is already a member of an IP
enabled VLAN. This configuration option should not be allowed. (Q01666045)
ERS 8600 does not allow configuration of IP address on a VLAN which has tagged Brouter port as a
member. This operation should be allowed. (Q01666040)
The CLI command "show ip rsmlt info" does not display the SLT id correctly when more than 8 SLT are
assigned to a RSMLT enabled VLAN. (Q01675726)
ACE filters configured using JDM for egress queue assignments are lost after a switch reset. Current
workaround is to configure via CLI, but do not specify the optional NNSC egress-queue parameter.
(Q01673091)
ERS8600 is not able to dynamically learn additional, or the removal of, NLB servers into a NLB server
cluster, when nlb-multicast mode is set. To properly learn, the nlb-multicast mode must be disable and
then re-enabled. This would be required if NLB servers are either added or deleted from the NLB server
cluster. (Q01671933)
The CLI command “show ip rsmlt info” incorrectly shows RSMLT as UP when all SMLT IDs associated
with the RSMLT VLAN are deleted and switch is reset. (Q01651440)
The CLI command “show ip rsmlt info” incorrectly shows RSMLT as UP even though no SMLT ID is
associated to the RSMLT enabled VLAN. (Q01652193)
User is able to create filters with an unsupported mask length of less than 8 bits. This situation is
associated only with legacy cards. (Q01628617)
ACL associated with a DSCP attribute does not work if any other attribute is configured along with it.
(Q01691761)
The CLI command “config ip ospf interface <ip address> disable” will disable OSPF globally. In order to
disable OSPF on an interface please execute the following CLI command “config ip ospf interface
<ipaddress> admin-status disable”. (Q01647814)
In the case of Source Mac based VLAN associated with R-module ports the number of MAC addresses
configured for a VLAN multiplied by the number of ports of an I/O module belonging to that VLAN can not
exceed 75000. (Q01577517)
On ERS 8600 when filters are created with copytoprimarycp enabled, the packets would be sent to
primary CPU and CPU utilization would be high. When copytosecondarycp flag is enabled the packets
are sent to secondary CPU but the CPU utilization will not be high. With both copytoprimarycp and
copytosecondarycp enabled the packets will be sent to primary CPU but not to secondary CPU. The CPU
utilization of only primary CPU would be high. Use of the copytoprimarycp option in any form is not
recommended for any normal customer usage. (Q01541639)
For radius accounting of SNMP, while sending the start/Interim/stop request, the packets will not contain
the SNMP community string value. (Q01576692)
If STG is enabled, there will be 30 second delay in forwarding for the whole MLT, when a new port is
added or deleted from MLT. When a port is added or removed from an MLT, STG protocol is run over all
the ports and it takes 30 seconds for Spanning Tree to put the ports in forwarding mode. (Q01674414)
When SSH port is set to 65535, user is unable to make SSH connection to the switch. Do not use this
port number for SSH connections. (Q01663948)
MIB value for ifSpeed is not correct with 10 Gigabit interface. Currently, the MIB value 1410065408
represents a 10 Gigabit interface. (Q01174158-01)
Please also see Known Limitations Section of the Release Notes for Ethernet Routing Switch 8600 Software
Release 4.1.1.0.
The following documentation is added in “Upgrading to Ethernet Routing Switch 8600 Software Release
4.1” (Part Number -316674-C Rev00) under “reformatting the flash from 16 MB to 64 MB”:
The proper steps for remote telnet operation are now outlined in the newly updated 4.1.x.x Upgrade
Guide, P/N NN46205-400. (Q01611394)
The following documentation is corrected in “Release Notes for the Ethernet Routing Switch 8600 Series
Switch Software Release 4.1.1.0 (Part No. 317177-E) under “CR’s fixed in this release 4.1.1.0” for CR
Q01307380.
The "DirectedBroadcastEnable" feature is no longer enabled by default, and the 8600 does NOT forward
Directed Broadcasts on a given IP Interface/VLAN by default. All new configurations contain the default
value of "disabled." This change complies with RFC 2644.
While configuring a static multicast MAC, the user has to create the static multicast MAC address before
adding ports or an MLT to it or else add the ports or MLT along with the MAC address itself via the
following CLI command:
Config vlan<vlanid> static-mcastmac add mac <value> [port <value>] [mlt <value>]
When the user adds an MAC address in the range 01:00:5e:xx:xx:xx a warning message is displayed,
but the MAC address still gets properly added. (Q01567667)
The CLI banner can be set to a customized value which can be as long as 1896 characters (inclusive of
End of line chars). (Q01645319)
The following documentation is corrected in Network Design Guidelines, Ethernet Routing Switch 8600
software Release 4.1” (Part number 313197-E) under “Hardware and supporting software compatibility”
The correct part number for 256MB CPU upgrade kit is DS1411016, not DS1404016 as listed on page
430. (Q01621944)
Copyright © 2007 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: 13-Apr-2007
Purpose: Software maintenance release to address customer found software issues.
3. Platforms Supported
Ethernet Routing Switch 8600 modules in 8003, 8006, 8010, and 8010co chassis.
Please refer to the following documents for details on the Platforms Supported:
Release Notes for the Ethernet Routing Switch 8600 Series Switch Software Release 4.1.1.0 (Part No.
317177-E)
Installing Ethernet Routing Switch 8600 Switch Modules (Part No. 312749-K Rev 01)
Managing Platform Operations Ethernet Routing Switch 8000 Series Software Release 4.1 (Part No.
315545-E Rev 00)
Installing and Maintaining the Ethernet Routing Switch 8000 Series Chassis (Part No. 316314-F Rev 01)
Note: R-series modules are now supported in the 8010co chassis with a High Performance Backplane. Please
see ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
p80a4130.mib MIB
3321305
p80a4130.mib.zip MIB (zip file)
531934
p80a4130.md5 md5 checksum file
1489
p80p4130.dld 8600 POS module image
701771
p80t4130.dld 8600 ATM module image
906024
8600 image for the SuperMezz
8833826
p80m4130.img card
Firmware images
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR (only applies to
2284578
8630GBR modules)
SSL Images
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.3.0
This software release supports the Web Switching Module (WSM) running version WebOS 10.0.34.0
For MSTP the log messages are added for following events:-
a) Whenever a new VLAN or MSTI is created or the Region Name, Selector, or RevLevel is changed
g) When the port transitions to STP BPDUs from MSTP BPDUs or to MSTP BPDUs from STP BPDUs
h) When the port where edge-port was admin enabled, received a BPDU and reverted to OperEdge false
operation
For MSTP the SNMP traps are generated for following events:-
For RSTP log messages traps are added for following events:-
c) When the port transitions to STP BPDUs from RSTP BPDUs or to RSTP BPDUs from STP BPDUs
d) The event occurs when the port where edge-port was admin enabled, received a BPDU and reverted to
OperEdge false operation
For RSTP the SNMP traps are generated for following events:-
After the introduction of SNMP-v3 implementation in 3.7 and subsequently 4.1, RADIUS authentication and
accounting for SNMP required modifications. This enhancement aims at providing RADIUS accounting for SNMP.
The accounting will be done based on per SNMP Session which will record the duration of that particular session
and the number of packets/octets received for this session. Accounting is done for every session. The user for
any SNMP session has to be added as “snmp_user”. At the beginning of any session, a start accounting message
is sent to the RADIUS server. A stop accounting message is sent a period of time (based on the value configured
for abort-session-timer) after the session is terminated. If the abort-session-timer is configured as 30 seconds
(default value is 180 seconds) then a stop message is sent 30 seconds after the session is closed. The stop
accounting message contains the duration for which the session was maintained and the number of
packets/octets received for this session. If the session continues for a long period, then periodically (after every
config/radius/server#
Sub-Context:
Current Context:
create <ipaddr> secret <value> [usedby <value>] [port <value>] [priority
<value>] [retry <value>] [timeout <value>] [enable <value>] [acct-port
<value>] [acct-enable <value>]
delete <ipaddr> usedby <value>
info
set <ipaddr> usedby <value> [secret <value>] [port <value>] [priority
<value>] [retry <value>] [timeout <value>] [enable <value>] [acct-port
<value>] [acct-enable <value>]
Under: /config/radius/snmp#
Sub-Context:
Current Context:
abort-session-timer <value> {30..65535}
acct-enable <true|false>
enable <true|false>
info
For the accounting to happen, the user will have to make true both the enable as well as the acct-enable
parameters.
Accounting is done based on the IP Address of the SNMP Client and the Community String used for accessing
the switch. The following statistics are used for Accounting:
The Input-packets/octets, & Output packets/octets are calculated only for authorized users, i.e only for the users
to which switch has granted access. This data is calculated irrespective of the views associated to the community
string, for e.g.: Input-packets is incremented of all authorized users irrespective of whether that user has access
to a particular MIB or not.
Radius accounting for SNMP-v3 is same as V1 & V2 except that accounting is done based on per user name & IP
address.
Please note the following which apply to both SNMP-v3 and SNMPv1/v2:
a) Maximum number of Sessions that can run at a given time is limited to 100.
b) If from a server multiple sessions are run with same community string then all those sessions will be
treated as single session as they will have same IP/Community string.
c) Accounting-On message will not be sent if the user has not configured a valid radius server before
enabling radius accounting on the switch.
d) Even after logging off from a session & re-logging in, previous session’s data persists for some time
based on abort-session-timer value.
e) Traps are not accounted as a separate session cannot be created for traps.
f) We do not support IPv6 Currently for RADIUS.
g) When we open a session from JDM with SNMP v1/v2 login, two sessions are opened for the first time, but
one of them is closed after N seconds, N again being the value configured for abort-session-timer,
because Initially Both V1 & V2 packets are sent for authentication, then all the other info is sent are V2
packets. The session which was opened in the beginning for V1 is then closed.
The existing CLI command “config sys set hash-calc getmltindex” has been modified to allow src-port and dst-port
as optional parameters. This parameter will provide the transmit or egress MLT index/port for R-module port
ingress traffic.
Now, in some rare cases for TCP based traffic, the port displayed via the above CLI command and the actual port
through which the traffic flows may be different. This is an outstanding issue (Q01581700) which will be resolved
in a future release. Also the new hash algorithm is not applied to IPv6 traffic, just IPv4.
Note that the new hashing for IP traffic between a given source and destination IP address will be different for
TCP/UDP packets and ICMP packets. Therefore the use of ping, in conjunction with the 8600 ping-snoop feature,
is no longer always reliable to determine the hashed path taken by IP TCP/UDP traffic, if that hashing is
performed by an R-module ingress port. If the hashing is performed by a legacy module, then ping-snoop
functions just as before with other code releases.
Switch management
General
While configuring Day light saving time (DST) the date can now be entered in the Mm.n.d/hhmm or
MMddhhmm format. However, DST will not work if start date and end date are configured in the same
month or if the start and end date formats are different. (Q01531634)
ERS 8600 no longer pads the OID of RFC 3418 traps with a value of zero. (Q01461504-01)
In a system with and 8692SF/CPU with Mezz option installed and enabled, file system issue, which
previously required a re-boot to clear, will no longer be seen. In the above type of configuration, rlogin
boot flag should still be set to enable. (Q01475831)
With Device Manger version 6.0.4.0, creation of a graph for filter statistics now works properly.
(Q01529304)
ERS 8600 now return proper value of MIB 2 structures for a 10GB card. However the value of ifspeed is
incorrectly displayed as zero, as the counters for this interface are using 64 bit counters, while standard
MIB 2 structures are based on 32 bit counters. There are no plans to change the ifspeed OID operation.
(Q01540174)
After a FTP session is initiated on an ERS 8600 switch, the RWA password is no longer saved in the
clilog.txt file. (Q01274075)
In an HA configuration with the ERS8600 unable to load the dld image for R module cards, the system
will no longer pick up an incorrect config file if the system also needs to load the backup-configuration-file.
(Q01536179-01)
Platform
General
ERS8600 Enterprise code now works properly with the 8692omSF/CPU. (Q01526505)
CLI Command “clear port stats slot/port” now clears statistics for 10GE port. (Q01529652)
On an ERS 8600 switch to load a Mezz image whose version is different from boot image version the
Mezz image name has to be configured via the following CLI command
However in this case all the functionality might not work as expected. The following warning message
would be generated upon boot time.
"Warning: The Mezz CPU was booted with Image Version: <version number>Incompatible with Boot
Monitor Image Version <version number> .Not all functionalities might work as expected. Please either
re-boot with proper Boot Monitor Image or load the proper Mezz/Runtime Image”
In this scenario for R-modules, the DLD version must to be the same as Mezz image version, or else the
R-module will not come up. (Q01522508)
8630GBR ports will no longer flap or show errors, upon a disable of the port with certain SFP types in the
connected device. (Q01498022)
The Egress Queue Set for queue id 0 is now displayed properly in DM. (Q01490598-01)
The CLI prompt will no longer be returned to the user until the actual FPGA update has completed, for
either a direct console login session or a remote telnet/ssh/rlogin session. A spinning wheel has been
added to inform the user that the FPGA update is still in progress. This new process will prevent the user
from rebooting a switch too early in a FPGA upgrade situation, which previously might have made the R-
module inoperable, and requiring an RMA. (Q01509339)
The port statistics are now properly displayed for all 10GE modules. (Q01547182)
Layer 2 switching
General
When both port state and VLACP are toggled on an SMLT edge port, the SMLT port now always comes
back up properly and there are no connectivity issues, such as loss of OSPF adjacency across the IST
MLT. (Q01525733)
In a specific SMLT configuration where a combination of both SMLT and S-SMLT configurations are
present, when a SMLT link is disabled there are no longer connectivity issues with the S-SMLT ports. A
prior work-around to this situation was to configure the IST MLT with an MLT ID of 32, but that is no
longer a requirement. (Q01538184)
In an SMLT set-up with HA-CPU mode enabled and all IST connections running on R modules, when the
SMLT Core Switch with the lower IP address associated with the IST VLAN is fully rebooted, the IST now
come up properly. (Q01533253)
If multiple SRC MAC based VLANs were configured the information of all the SRC MAC VLANs with
lower VLAN IDs was not properly displayed. This situation is now resolved. (Q01534001)
In a system which has multiple STGs, the STG port states are now displayed properly after an R-module
is reset or upon an HA failover. (Q01479548-02)
If an ACL with redirect-next-hop is configured on an ingress port of the switch and the specified next-hop
is not available and global-action is set to mirror-count, the port no longer shuts down because of CP-
Limit being invoked, and traffic will now flow as expected. (Q01493502)
On an ERS 8600 switch which has dual CPU running in non HA mode, SMLT-on-SingleCP can now be
enabled. (Q01512389)
In a square RSMLT set-up which has OSPF enabled, when the DR or BDR switch is reset the IST will
come back-up properly. (Q01594982)
IP Unicast
General
On an ERS 8600 unicast packets which are to be routed are no longer dropped by R modules if the
ingress and egress port is the same; this requires the port to be tagged. (Q01511596)
In an RSMLT set-up when one of IST peer is reset, a non-local default static route whose next-hop is not
reachable will now stay inactive. However the problem might be seen if the user does an “apply” to a
route policy from Device manager or CLI. It is recommended that users do not create default static routes
on both the OSPF neighbors pointing to each other, along with static to OSPF redistribute flag enabled,
as this will create a potential route loop situation. (Q01521914/1522816)
OSPF
In an SMLT set-up with HA mode enabled, when one of the other switches in the network is power cycled
OSPF sync error messages are no longer seen on standby CPU of that switch. The same messages
were never seen on master to start with. (Q01535376)
ERS 8600 switch now handles OSPF Opaque LSA types 9, 10 and 11 properly. (Q01509489)
On ERS 8600 IST can becomes unstable when IP Flow Information Exchange (IPFix) collector becomes
unreachable. To not see this issue, disable IPFix globally or make sure some collector is reachable when
using IPfix. (Q01541086)
For an 8630 GBR, the CWDM SFP is incorrectly displayed by CLI or JDM as type equals LX, but the SFP
operates correctly – this is a display issue only, with no operational affect. (Q01579140)
On an ERS 8600 switch when a port is part of a subnet based VLAN, this port may drop traffic for this
VLAN if filters are configured on any other port, as well traffic being of a frame size below 256 bytes and
sent with a minimum inter-frame gap, meanings packets must ingress one directly behind the other. It is
also believed this situation is only seen with certain E modules. (Q01557280)
When OSPF traps are enabled the extra information about the state transition of adjacencies does not
appear in the log messages. (Q01559787)
When multiple Access Control List ACEs are simultaneously disabled from Device Manager, multiple
COP software error messages are logged in the log file. Disable ACEs one at a time and the situation will
not be seen. (Q01581660), (Q01581699)
IP Flow Information Exchange (IPFix) feature may not work properly when configured on port 48 of slot
10. (Q01568603)
The port link errors stats are not cleared when counters are reset. (Q01578488)
On an ERS 8600 NLB packets configured for multicast mode [only] which are to be routed are dropped by
an R module port if the ingress and egress port is the same. This requires the port to be tagged and
connected to an L2 device. Moving the NLB device to either the same VLAN or different VLANs off of
different ports will workaround this current limitation. (Q01565360)
If you have a VLAN containing R-module ports configured to use VRRP Fast Advertisements, VRRP
transition may happen and ports may go down on associated MLTs when the backup 8692SF/CPU is
removed and then re-inserted in a dual 8692SF/CPU system, regardless of the HA-CPU setting.
(Q01468173)
In an HA configuration with the ERS8600 unable to load the dld image for R-modules, the system will
pick up an incorrect config file if the system also needs to load the backup-configuration-file.
(Q01536179-01)
If a MAC address is added to the Source MAC based VLAN via SNMP error messages may be seen.
Also information about the Source MAC based VLAN may not be correctly displayed by the CLI command
“show vlan info src mac”. (Q01577517)
While upgrading a R-module with any firmware image, if the file name is missing from the specified path,
it may cause the ERS 8600 to reset. Please make sure when updating R-module firmware images the
proper and exact procedure is currently followed. (Q01583614)
If a user configures a static multicast MAC address in the 01-00-5e-00-xx-xx range a proper warning
message is generated, but the multicast MAC is not properly associated with the VLAN, but instead with
just a port within the VLAN. (Q01567667)
On an ERS 8600 with HA mode enabled, if a VLAN with OSPF has both secondary and primary MD5
keys, when the primary key is changed and HA failover is done twice both the keys are displayed as the
primary key. (Q01593252)
If a packet matches the port ACE and VLAN ACE which have the same mode and overlapping actions,
the statistics of VLAN ACE are incorrectly incremented. (Q01592532)
In a square RSMLT set-up which has OSPF enabled, when the DR or BDR switch is reset sometimes the
IST may not come back-up properly. To resolve the situation toggle the IST status on the reset switch, to
disable and then enable. (Q01594982)
On a SMLT configured ERS 8600 the MD5 keys configured for OSPF authentication are not saved after
first reset, if configured prior to IST configuration. The situation is not seen after the MD5 keys are added
again and configuration file is saved. (Q01596219)
When ERS8600 switch is booted with a Mezz module installed, but no Mezz image in flash or
PCMCIA and the Mezz flag is set to true (by default Mezz flag is true) then the switch comes up with I/O
modules working as expected, but the user can no longer ping/telnet/ftp/tftp to the switch through
management port. If the Mezz image is available on flash or PCMCIA then there is no issue of
ping/telnet/ftp/tftp to that switch. Also if the steps outline in Section 2 of this Readme document, reference
CR 1617338, are followed the above situation will not be seen. (CR Q01617266)
When an ACL redirect-next-hop filter is created with action unreachable command to permit, and if the
next-hop is available but the ARP is not learnt on ERS 8600, packets would be forwarded, using a route
in the route table, versus the configured next-hop. Workaround and recommendation for these types of
configurations is to configure a static ARP entry for the next-hop. (Q01413767)
On an ERS 8000 series switch a MAC is not added to the FDB table of a port based VLAN if the same
MAC is added to a Source Mac VLAN. The problem happens only with Legacy cards. (Q01523549)
Although STP port priority values are in the range between 0-255, only the following values are actually
acceptable: 0,16,32,48,64,80,96,112,128,144,160,176,192,208,224,240. (Q01573415)
While configuring IP Flow Information Exchange (IPFix) feature it is recommended to only use the v9
format selection. ERS 8600 sends out data using Netflow version 9 formats only. (Q01568558)
When configuring VLACP the following standard ether-types should not be used. Also any well-known
MAC address should not be used when configuring VLACP. There is no check in the code for this
improper values, so care should be taken when configuring VLACP to use non-default values (CR
1583818):
Ethertype Protocol
0x0000- IEEE 802.3 length
0x05DC
0x0800 IP, Internet Protocol
0x0806 ARP, Address Resolution Protocol
0x8035 DRARP, Dynamic RARP. RARP,Reverse Address Resolution Protocol
0x80F3 AARP,AppleTalk Address Resolution Protocol
0x8100 EAPS,Ethernet Automatic Protection Switching
0x8137 IPX, Internet Packet Exchange
0x814C SNMP, Simple Network Management Protocol
0x86DD IPv6, Internet Protocol version 6
0x880B PPP, point-to-Point Protocol
0x880C GSMP, General Switch Management Protocol
0x8847 MPLS, Multi-Protocol label Switching(unicast)
0x8848 MPLS, Multi-Protocol label Switching(multicast)
On an ERS 8600 when an ACT has patterns for both ipv4 and ipv6, user will not be allowed to create
ACL with pktType as ipv6. (Q01583818)
If an ARP request is sent from an IP address with multicast Mac to ERS 8600, then it will not send out the
ARP reply. The corresponding FDB entry will not be learnt resulting in loss of connectivity. (Q01595163)
Please also see Known Limitations Section of the Release Notes for Ethernet Routing Switch 8600 Software
Release 4.1.1.0.
For the 8648GTR module or the 8648TX/TXE module, when we disable Auto-negotiation on a port and
even without any link connected, the port will be set to a particular speed and the speed LED of the port
glows in order to indicate the speed. The color of the Speed LED indicates the speed configured on the
port. (Q01511924)
On an ERS 8600 switch with RSMLT enabled when a user configures a default static route with an exact
preference value of 185, the static route is not saved in the configuration file. It is recommended not to
configure default static route with preference value of 185 when RSMLT is enabled on the switch.
(Q01587436)
When auto-negotiation is enabled/disabled on any of the ports of the MLT, it will be enabled/disabled on
all the ports of the MLT, and the MLT will go down and come back up. Since and IST is a special MLT,
this operation also affects IST MLTs. Since SMLT is dependent on IST, when IST flaps, SMLT links will
also flap. (Q01579329)
The following correction is done in document “configuring and managing security” (314724-E Rev-01)
under section configuring SNMPv3. (Q01588855)
To configure SNMPv3
The following documentation is corrected in “Release notes for the Ethernet Routing Switch 8600
Software Release 4.1.1” (NN46205-402, 317177-E Rev 01) under section “CRs fixed in release 4.1.1” for
CR Q01356928.
The issue with the remote link coming up before the 8630 GBR module is completely initialized has been
resolved in this release. However for the fix to work user has to upgrade the FPGA firmware image on
8630GBR module to PIM=769.
The mcast-mlt-distribution parameter and its operation is documented differently and inaccurately in
several different manuals. The correct operation is listed below, which will be incorporated as part of the
new re-write of the ERS8600 documentation set for the 5.0 Release in Dec., 2007. Please note that all
MLT distribution, be it for unicast or multicast traffic, is a decision made by the ingress port, and therefore
the port style make-up of the MLT itself has no affect on this operation. (Q01568460)
If the ingress port is a classic/legacy module port, and the parameter is enabled, distribution will always
occur for IPMC traffic, be it L2 (same VLAN) or L3 (inter-Vlan).
If the ingress port is a R-module port and the egress MLT is in the same VLAN (L2 flow) distribution will
occur only if IGMP snoop is enabled. For inter-VLAN or L3 flows, distribution will always occur for ingress
IPMC traffic for a R-module port. In this configuration an IPMC L3 routing protocol must be enabled, or
some static IPMC routing configured.
Distribution will never occur for a pure L2 multicast traffic (multicast destination MAC only), which has no
L3 IPMC address, only if the ingress port is a R module port.
If IGMP snoop is enable for particular VLAN/Brouter port, CLI/JDM doesn't allow to configure L3 multicast
protocol on that VLAN/Brouter port.
A new version of the Installing an AC Power Supply in an Ethernet Routing Switch 8000 Series Chassis
has been web post (P/N 312751-E, Rev 01), which contains the following change on various pages:
Nortel does not support 8001AC and 8002DC power supplies with R modules. R modules installed in the
8006, 8010, or 8010co chassis require the 8004AC, 8004DC, 8005AC, or 8005DC power supplies.
OVERVIEW
On Ethernet Routing Switch 8000 SNMPv3 Notification was introduced to replace traps. The older mechanism supported
a simple configuration consisting of a trap receiver (typically an NMS), the SNMP version (either v1 or v2c) supported, and
NOTE: This document is taking a clean start and reconfiguring the security names from scratch, i.e. not assuming
default security names. To perform such an SNMP-v3 reconfiguration from scratch and to start from a clean slate
(all snmp-v3 tables empty) one would need to execute:
If one chooses not to do the above (and hence keep the default entries in the snmp-v3 tables), the default usm
security name "initial" should be deleted as it is a security hole if left in place, as anyone can connect with full
rights without a password.
FUNDAMENTALS
Configuring Notification involves having knowledge of SNMPv3. While this document is not intended to cover SNMPv3
certain basic concepts will be touched upon.
How to build a “Notification” configuration that determines what an ERS switch sends out
Configure an SNMP notification trap type (since this is part of the default configuration, this command does not need to be
executed normally).
>> config snmp-v3 notify create Trap tag trapTag type trap
Define mib views as needed. In this example a default mib view is used (under normal conditions there’s no need to
execute this command).
>> config snmp-v3 mib-view create root 1 type include
Create group entries in the VACM. Associate mib views with each access entry.
Associate a target parameter entry with a security name (for mib access rights)
>> config snmp-v3 target-param
>> create parmList-1 mp-model snmpv1 sec-level noAuthNoPriv sec-name John
>> create parmList-2 mp-model usm sec-level noAuthNoPriv sec-name Amy
Associate target parameter info with target addresses. This calls out the snmp model, authentication/privacy (in the case
of v3), and the type of notification to be sent.
>> config snmp-v3 target-addr
>> create NMS-1 10.10.10.10:162 parmList-1 taglist trapTag
>> create NMS-2 10.10.10.20:162 parmList-1 taglist trapTag
>> create NMS-3 10.10.10.30:162 parmList-2 taglist trapTag
How to build a “Notification” configuration that filters what an ERS switch sends out
Make sure target parameter entries exist (using the previous configuration).
Make sure target address entries exist (using the previous configuration).
Associate a notification based filter with an entry in the target address table
>> config snmp-v3 ntfy-profile create parmList-1 profile noLinkDown
Example: To filter on OID “1.3.6.1.4.1.*.1” a mask of 0xfd (1111 1101) must be applied. When the mask set contains
fewer bits than the OID specified then the mask is extended with 1’s (i.e. no wildcards are used). In the case where no
mask is entered an exact match of the OID specified is the filter (mask would be 0xff:ff). By default OIDs are considered
“included”.
Fine point: When setting filters be sure to pay attention to what’s being done with the objects passed in trap OIDs. If the
OIDs of the passed objects get excluded the entire trap will be excluded (In other words a trap sent cannot filter one
passed object and not another).
Test Case#2:
Bring up an 8600 and force a data link in the system to go down. A link down trap should only be seen on NMS-3. Now,
let’s clear this condition by typing:
>> config snmp-v3 ntfy-profile delete parmList-1
This configures all standard traps and only the save config trap from the PP8600 proprietary set of supported traps on
NMS-1 & NMS-2. For NMS-3 all supported traps on PP8600 are configured with the exception of standard OSPF traps
(other than the OSPF IF state change trap).
Now, attempt to save your configuration. You should see a save config trap on NMS-1 and NMS-2. If you attempt to
generate a proprietary trap (say either a card up or down trap) you should see it on NMS-3 only. If you attempt to
generate standard OSPF traps supported by PP8600 you should see all of them on NMS-1 and NMS-2. On NMS-3 you
should only see the OSPF IF state change trap.
Additional Note: The SNMPv3 user configured here is not secure. Please review the document “Configuring and
Managing Security” for more information regarding how to setup secure users.
Copyright © 2007 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: Feb-5th, 2007
Purpose: Software maintenance release to address customer found software issues.
DST will not function properly when DST-Start and DST-End are configured in the same month, except (again) if
configured within the current month. Since DST-Start and DST-End are generally never configured in the same
month, this operation will not be changed. Therefore there should be no current issues with DST configuration,
with possible exception being related to CR 1531634 (see within this Readme), which will now be fixed as well in
a future release.
3. Platforms Supported
Ethernet Routing Switch 8600 modules in 8003, 8006, 8010, and 8010co chassis.
Please refer to the following documents for details on the Platforms Supported:
Release Notes for the Ethernet Routing Switch 8600 Series Switch Software Release 4.1.1.0 (Part No.
317177-E)
Installing Ethernet Routing Switch 8600 Switch Modules (Part No. 312749-K Rev 01)
Managing Platform Operations Ethernet Routing Switch 8000 Series Software Release 4.1 (Part No.
315545-E Rev 00)
Note: R-series modules are now supported in the 8010co chassis with a High Performance Backplane. Please
see ReadMe for Ethernet Routing Switch 8600 Software Release 4.0.2.0.
p80a4120.mib MIB
3319366
p80a4120.mib.zip MIB (zip file)
531719
p80a4120.md5 md5 checksum file
1489
p80p4120.dld 8600 POS module image
701771
p80t4120.dld 8600 ATM module image
906024
8600 image for the SuperMezz
8825131
p80m4120.img card
Firmware images
foq267.xsvf FOQ
5320469
bmc776.xsvf BMC
2640266
dpc184.xsvf DPC
2583454
PI_769.xsvf PIM8630GBR
2284578
SSL Images
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.3.0
This software release supports the Web Switching Module (WSM) running version WebOS 10.0.34.0
Switch management
General
When a save config command is executed, the saved config file is equal to the last runtime config used.
Now, if the primary configuration file in the bootconfig (/flash/boot.cfg) is different from last runtime
configuration file then the following warning message would be displayed on console, written to the log
file, but not displayed on telnet/ssh logged in sessions. This is a warning to the user that should the
switch boot, the config file that the switch will boot with, maybe different then the current running and
saved config file.
Where <file name> is the name of the primary configuration file. (Q01401503)
The PCAP global configuration parameter AutoSaveFileName no longer allows a zero character file name
to be configured. (Q01381856-02)
Users will now be able to login to an ERS8600 using SSH with Public Key Authentication.( Q01483948,
Q01483488)
The following RMON traps, last system change and Ethernet octet stats, are now properly recognized by
Device Manager. (Q01142068)
The System Configuration parameter "#! flags system-monitor false" will now be displayed as TRUE when
issuing the command “show config”. Previously the flag displayed a value of false, even though it was
operationally true. This parameter is not user settable as well. (Q01485344)
If repeated Telnet or FTP sessions are opened against any 8600 In Band and/or out of band IP
addresses with quick closures, over the course of time this could lead to system instability. This situation
is no longer present with this code release. (Q01462275)
Incompatibilities between Device Manager Version 6.0.3 and WSM modules running version 10.0.34.0
are no longer seen with this code release. (Q01491448)
RADIUS authentication will no longer fail when users repeatedly log out before the RADIUS server sends
the reply. (Q01406191)
RLOGIN sessions which are kept idle are now logged out after expiry of time out period. (Q01410171)
Platform
General
If the SuperMezz option is enabled and the switch is reset, ATM modules will no longer get disabled.
(Q01463279)
When multiple WSM cards are installed in the same chassis, upon a switch reboot all WSM cards will now
The total available power for the 8005AC RoHS compliant power supplies, DS1405012-E5, P/N 321411,
will now use a value of 1372W, which is correct for the supply running at 220 VAC, versus the prior usage
of the default value of 690W. This makes the 8005AC RoHS power supply function like the non-RoHS
version. This change will alleviate users from potentially seeing any erroneous warning messages
regarding insufficient power for the system. At the same time this functionality always assumes the
8005AC, both the RoHS and non-RoHS versions, is running at 220 VAC. For systems that are run at 110
VAC, the calculation will be incorrect and this field should be ignored. As well the calculation for Power
Usage is not 100% correct as well. Neither of the later two situations has been addressed in this code
release. (Q01495801)
The below warning message is displayed when configuration changes are being made to the egress
queue set:
WARNING: The egress-queue-set QoS change made will take effect only after the configuration is
saved and the chassis is rebooted.
(Q01450460-01)
The "show port info state" command will now reflect the time and date of the last state change for a port.
(Q01474469-01)
An ERS8600 with HA-CPU (hot standby) mode enabled, and containing an installed 8683XZR module,
will no longer have any 8683XZR ports become inactive after an HA failover has completed.
(Q01484430-01)
8630GBR when connected to SUN NIC with auto negotiation enabled no longer causes a connectivity
issue to the end station with the SUN NIC. (Q01434934-01)
For a dual SF/CPU non-HA mode (warm standby) configuration, with an 8683XZR card present, the
system will no longer have the 8683XZR module become inactive when the master SF/CPU is reset.
(Q01487003-01)
The warning message displayed when the FPGA update command is executed has been modified as
below to indicate to the user to wait for "FPGA UPDATE SUCESS" message before executing any other
command. In a future release of code, the CLI prompt will no longer be returned, until the actual FPGA
update has completed.
WARNING: Starting the FPGA update process. DO NOT reset the card or box during this process.
Please wait for FPGA UPDATE SUCCESS message.
(NOTE: Command prompt will be returned but update process can take up to several minutes)
(Q01501599-01)
RoHS compliant GBICs are no longer displayed as GbicOther in CLI and Device Manager. (Q01453100-
03)
8630GBR and 8683XZR cards will no longer become inactive when the master SF/CPU is failed on a
switch with HA-CPU (hot standby) mode enabled. (Q01493870-01, Q01525078,Q01521770)
An ERS8600 containing an installed 8683XZR module will now show proper configuration options for
clock source and framing options for its WAN ports under all conditions. (Q01494672-01, Q01493665-01)
For an 8683XZR module with a 10GBase LR/LW XFP running in WAN mode, the port will no longer go
down after the port state is toggled. (Q01512208-01)
On an ERS8600 switch having dual SF/CPUs with a large configuration file and CLI log enabled, there
are no longer any issues related to SF/CPU failover. (Q01525314)
General
Null Strings and Strings starting with a blank or a white space are no longer allowed to be configured
as MLT names. (Q01478418-02)
For Core IST switches in any SMLT configuration, ARP entries will now correctly point to SMLT ports
versus the IST ports. (Q01476117)
The configured STP state of a port in RSTP mode is now saved correctly in the configuration file.
(Q01422525)
IP Unicast
General
OSPF routes are now summarized properly when a Virtual link is present. (Q01444180-01)
When a dhcp-fwd entry is created with the same IP as the VRRP IP, changing the VRRP
configuration will no longer cause the CPU utilization to rise to 100%. (Q01473196-01)
For an ERS8600 running OSPF and having an OSPF route with 32 bit mask that overlaps another
OSPF route, the switch will no longer become unstable. (Q01491868)
ERS 8600 will now send a trap and display a warning message when any VRRP IP address is
assigned to any other device (duplicate IP) in the network. Previously duplicate IP warnings were
only generated for physical switch IP address; this now adds warning support for VRRP IP
addresses. (Q01352422-01)
For an ERS 8600 with the tagged-frame-discard parameter enabled on a port, IPv4/IPv6 bridging on
any protocol based VLANs associated with the port now works properly. (Q01427096)
Dynamically learned routes can now be deleted from CLI via the following command “config ip route
delete <ipaddr/mask> next-hop <value>” or from Device Manager via IP->IP-> Routes->delete.
If an OSPF route is deleted the route will not reappear in the database unless there is network state
change or if an SPF is run. (Q01475773)
On an ERS 8600 switch executing the CLI command “show log file tail” followed by “Q” will no
longer restart OSPF. (Q01506294)
When one switch, in an IST Core configuration, is power cycled there will no longer be the potential
for the IST to not form properly, especially in configurations where there are multiple OSPF adjancies
formed between the 2 IST Core switches. Additionally, there would no longer be unicast and multicast
traffic loss. (Q01535355, Q01505335)
BGP
Modifying the eBGP route preference to the recommended value of 15 no longer causes connectivity
issues. (Q01407546)
IP Multicast
When (S, G) RPT entry is present in the DR and a receiver joins the group, the multicast routing table
will now switch to the shortest path. (Q01464913-02)
On ERS 8600 tagged multicast traffic that ingress and egresses the same R-module port will now be
properly forwarded through R modules. (Q01478516)
Multicast traffic is now forwarded to the downstream port when diff-serv is enabled and access-
diffserv is set to TRUE on the ingress R module port. (Q01479569-01)
The monitor port stats command will not show correct values of IN_UTIL and OUT_UTIL when the
monitor interval is increased beyond the default value of 5 seconds. Currently do not change the monitor
interval for proper operation. (Q01522756-01)
On an ERS 8000 series switch a MAC is not added to the FDB table of a port based VLAN if the same
MAC is added to a Source Mac VLAN. (Q01523549)
Loopback testing commands are not working for R modules. Future support for the 8648GTR and
8683XLR and XZR is planned. Support on 8630GBR is not planned due to internal hardware restrictions.
(Q01498160)
On an ERS 8600 unicast packets which are to be routed are dropped by R modules if the ingress and
egress ports are same. (Q01511596)
ICMP packets with TTL of 1 are sent to the CPU as high priority packets, which under heavy usage could
cause other high priority packets to be lost. This can lead to system instability. This is improper handling
of these packets, which will be corrected in a future version of code. (Q01510545)
CLI Command “clear port stats slot/port” does not clear statistics for any 10GE port. (Q01529652)
When VLACP is toggled on an SMLT edge port, the SMLT port may not come back properly, which can
lead to traffic passing issues, such as OSPF adjacency loss (RSMLT configuration). To workaround this,
either do not toggle VLACP state, or not use VLACP on SMLT links. (Q01525733)
In an RSMLT set-up when one of IST peer is reset, a non-local default static route whose next-hop is not
reachable will becomes active. Do not currently configure non-local static routes in RSMLT configurations.
(Q01521914)
With Device Manger version 6.0.3.0, creation of graph for filter statistics does not work. This is a DM
limitation and requires a change in a future version of DM for resolution. (Q01529304)
With Device Manager Version 6.0.2.0 and 6.0.3.0 (6.0.1.0 worked properly) the settings for the duplex
parameter on a port cannot be changed. This is a DM limitation to be resolved in a future release.
(Q01531475)
ERS 8600 switch does not currently handle OSPF Opaque LSA types 9, 10 and 11 properly.
(Q01509489)
On an ERS 8600 switch the SNMPv3 group entries are not retained on switch reset if the group name
includes space character. Do not create SNMPv3 group entry names that include a space. (Q01539098)
ERS8600 Enterprise code will not currently work with the 8692omSF. (Q01526505)
During the 60 seconds lockout period on master for a failed telnet, ssh, or rlogin session, users are also
unable to make new telnet, ssh and rlogin connections to the slave, during the same 60 second lockout
period. (Q01540836)
On an ERS 8600 switch FTP, RLOGIN, TFTP are not supported for inbound IPv6 address. However
these will be supported in future development release. (Q01492490,Q01476296,Q01475131)
In an SMLT set-up with HA-CPU mode enabled and all IST connections running on R modules, when
SMLT aggregation switch with the lower IP address associated with the IST VLAN is fully rebooted, the
IST may not come up. Workaround is to disable and then enable the IST on the switch which has the
higher IP address associated with the IST VLAN. (Q01533253)
In an SMLT set-up with HA mode enabled, when one of the switch is power cycled OSPF sync error
messages are seen on standby CPU of other switches. Workaround is to currently disable HA-CPU
mode. (Q01535376)
In an SMLT configuration where both SMLT and SLT are present, in a specific scenario when SMLT link
is disabled the SMLT status on the Peer IST stays as “SMLT”; this can create connectivity issues.
Workaround is to configure the IST MLT using an MLT ID with a higher value than any other configured
MLT IDs, of which using an MLT ID value of 32 will always provide such a workaround. (Q01538184)
On an ERS 8600 switch with R modules, the Ctrl-Rec-optimization feature is not supported, and the
feature is recommended not to be used in a chassis with any R-modules present. (Q01292928-01)
Single Fiber Fault Detection is supported on the ERS 8600 but should a user run into any issues with its
operation, it is recommended that the user uses VLACP to achieve the same functionality.
(Q01464922),(Q01347146-01)
On an ERS 8600 switch with mezz flag enabled, it takes longer for the files to be copied from /PCMICA to
/FLASH. (Q01526038)
On the ERS8600 switch, the –f option cannot be used with SSH non interactive commands. (Q01393349-
01)
Duplicate IP Multicast traffic over the IST can be seen in specific SMLT configurations. To avoid this
situation, please reference the information contain in the Network Design Guide for Release 4.1 (Part No.
313197-E, Rev 00) page 305 – 309. (Q01539663, Q01270581)
Please also see Known Limitations Section of Ethernet Routing Switch 8600 Software Release 4.1.1.0.
Documentation Corrections
In Release notes for the Ethernet Routing Switch 8600 Release 4.1.0 under “Hot-swapping the SF/CPU
module or I/O modules”
When hot-swapping the active CPU/SF module in an Ethernet Routing Switch 8600 with dual SF/CPU
modules (HA mode enabled or disabled), wait until the previous standby SF/CPU module is stabilized
before inserting any other modules; this includes a replacement SF/CPU or reinserting the originally
removed SF/CPU. This stability can be noted by the SF/CPU module displaying a login prompt on the
console screen. If no console connection is available, wait for at least thirty seconds or until the previous
standby CPU becomes master, whichever is longer before inserting the replacement SF/CPU module or
before reinserting the originally removed SF/CPU module. (Q01489847-01)
The default IP address for the management port is 192.168.168.168/24 for slot 3 of a 3-slot chassis and
slot 5 of either an 8006, 8010, or 8010co chassis, and 192.168.168.169/24 for slot 6 of either an 8006,
8010, or 8010co chassis. The use of IP address 0.0.0.0 and subnet mask as 0 for management IP
address is not allowed; therefore the management IP addresses can never be set to no IP address. If the
192.168.168.0 subnet is required for use for the I/O ports, then the management port IP addresses must
be changed first. Once the IP addresses is changed, to change a second time, it maybe required to set
the IP address back to the default values, and changes are then allowed to any address. (Q01492184)
Configuring QoS and IP Filtering for Ethernet Routing Switch 8600 R Modules( Part No 318637-B Rev
00) under traffic shaping statistics, page 89, the following information regarding packets and memory
pages should be noted and will be added in the next revision of the manual:
Each memory page is 512 bytes in length except the first page which is 144 bytes in length. The number
of memory pages used for egress queuing will depend upon the packet size. A packet of size between
64-148 bytes requires 1 memory page, packet size between 149-632 bytes requires 2 memory pages,
packet size between 633- 1120 bytes requires 3 memory pages and packet size between 1121-1518
bytes requires 4 memory pages.
(Q01539128)
Configuring QoS and IP Filtering for Ethernet Routing Switch 8600 R Modules( Part No 318637-B Rev
00) under Updating Action parameters for an ACE following documentation needs to be added:
The optional parameter [mlt-index <index>] is not supported for multicast traffic, but only unicast traffic.
(Q01541824)
Starting with JDM 603, there are two runtime generated property files: dm.xml and dm_devices.xml. They
are placed in a hidden folder called "jdm" under user's profile. The first file holds the last opened device
list which has the same as dm.ini with different format. The second one holds device property sets, one
set per device. JDM uses the specific property set while communicating with the device. For example,
This new feature keeps property files for each JDM user, not for each JDM installation. For example, on
Window 2000, the files are located on d:\Profile\<user>\jdm directory.
The procedure to convert the dm.ini generated in JDM 59x to the property files used in new JDM 60x is
as follows:
Because the property files are per user base, not per JDM installation, the conversion needs to be done
only once, and the same files will be kept and reused for the subsequent JDM release
(Q01546524)
In some extremely rare cases, you will see the following error message "CPU [5|6] [[date] [time]] HW
INFO <module type> card on slot <slot number> bootup timeout. Related configuration will be lost". This
error message displays after a reboot, the side effect is that the ports of this module use the default
configuration. It situation can happen if the line card comes up but is offline during the duration when the
configuration is sourced. This situation causes the configuration to be lost on the ports of that card. If you
experience such conditions, please source the current configuration file to make the module operational.
(CR Q01395294)
While configuring Day light saving time(DST) please enter the day in the < Mm.n.d/hhmm> format which
is the n-th occurrence of day d in month m, along with hour and minute; only this format will work.
(Q01531634)
Precedence – If more than one policies are matched for an incoming request, the value of precedence
determines which one of them would be applied. Lower the precedence value, higher the priority.
o config sys access-policy policy 2 precedence 10
network – If configured for a policy, then the policy gets applied only in case the subnet of the source ip
address of the incoming access request matches the configured network address.
o config sys access-policy policy 2 network 198.202.188.0/24
host - If configured for a policy, then the policy gets applied only in case the source ip address of the
incoming access request matches the configured host ip address.
o config sys access-policy policy 2 host 198.202.188.174
accesslevel – Determines the access level which the user should have if he is to be granted access. If the
user’s access level is greater than the one configured for the policy, he would be granted access or not
depending upon whether access-strict is set to true or false.
o config sys access-policy policy 2 accesslevel rw
access-strict – Determines whether users with access levels greater than the one configured for the policy
should be allowed access or not.
o config sys access-policy policy 2 access-strict true
NOTE: With the above configuration for accesslevel and access-strict, only users with rw access would be
allowed access. Had the access-strict been set to false, both rw and rwa would have been given access.
The following parameters will be having default values when an access policy is created. User can change them if
required. Below is the explanation of the parameters with examples
Name -- Used to set the name of the access-policy
o config sys access-policy policy 2 name policyName
mode – Used to determine whether access be allowed or denied to an incoming request if it matches
the policy
o config sys access-policy policy 2 mode allow
Precedence – If more than one policies are matched for an incoming request, the value of
precedence determines which one of them would be applied. Lower the precedence value, higher the
priority.
o config sys access-policy policy 2 precedence 10
host - If configured for a policy ,then the policy gets applied only in case the source ip address of the
incoming access request matches the configured host ip address.
o config sys access-policy policy 2 host 198.202.188.174
accesslevel – Determines the access level which the user should have if he is to be granted access.
If the user’s access level is greater than the one configured for the policy, he would be granted
access or not depending upon whether access-strict is set to true or false. This parameter is not
applicable to snmp service in rel4.1.x
o config sys access-policy policy 2 accesslevel rw
access-strict – Determines whether users with access levels greater than the one configured for the
policy should be allowed access or not. This parameter is not applicable to SNMP service in rel4.1.x
o config sys access-policy policy 2 access-strict true
NOTE: Moving with the configuration example given above, only users with rw access would be allowed access.
Had the access-strict been set to false, both rw and rwa would have been given access.
4). Add the snmp-groups and the security model to the access policy. The default snmp-groups and the security
models for allowing access to private and public community strings are:
readgrp snmpv1
readgrp snmpv2c
v1v2group snmpv1
v1v2group snmpv2c
6). If a new community name is to be granted access through a policy, then the snmp-group corresponding to the
community string and the security model should be added to the access-policy.
In 4.0.x the default community strings public, private and secret are mapped to access levels ro, rw and rwa
respectively. The access policy check (if snmp service is enabled) is done against the configured policy’s allowed
access levels (access level & access-strict values).
(NOTE: these access levels would still hold the same significance as before for services other than snmp like ftp,
telnet, rlogin etc.). Each community string in 4.1.x would have a security name corresponding to it. This security
name would be associated to an snmp group name under the snmp-v3 group-member table, for different security
models. Access to a particular community string is granted based on the group name and the security model.
Please note that in 4.1.x , the
snmp service in access policy is disabled by default.
For the upgrade from 4.0.x to 4.1.x to happen smoothly, the user is expected to do a ‘save config verbose’ in
4.0.x before upgrading. During the upgrade from 4.0.x to 4.1.x, the snmp-groups get added to an access-policy
only in case the policy has snmp service enabled (which is the case by default). If the service is disabled, the
snmpv3 service gets disabled and no groups get added to the policy.
For default communities public and private in 4.0.x with access-policy configured, their access state would be the
same after upgrading to 4.1.x also. But for community secret, access would not be granted after upgradation. This
is because community secret comes up as a default entry in 4.0.x, but not in 4.1.x. In 4.1.x there are just two
default community entries created - public and private.
In 4.0.x the communities’ public and private have access levels ro and rw by default.
And in 4.1.x they have the security names readview and initialview respectively. Whenever a user upgrades from
4.0.x to 4.1.x, the command ‘config sys access-policy policy id service snmp enable’ would get executed through
the config file (saved in rel4.0.x in verbose mode) for the policy. Now this command would enable the snmpv3
service for the policy in rel4.1.x and also add a set of snmp-groups with security models to the access policy. The
snmp-groups would be added by default during the upgrade based on the access level to group mapping given
below:
TABLE 1
Now in 4.0.x, access is granted based on the community string to access level mapping. After upgrading to 4.1.x,
access would be granted if the group names and the security levels corresponding to the community string are
added to the policy. For the case where the access policy has rwa as its configured access level, we don’t add
any snmp-groups on upgrade because with this access level, only the community secret was being granted
access in 4.0.x which is not available in 4.1.x by default.
EXAMPLES: Following are screen captures of some example configurations before and after upgrading from
4.0.x to 4.1.x
EXAMPLE 1): Upgrade with access level configured as ro, access-strict as false and
snmp enabled in 4.0.x
©2009 Nortel (9-Feb-2009) Page 92 of 106
In 4.0.x(before upgrading)
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy2
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readOnly
access-strict : false
Sub-Context:
Current Context:
http : disable
rlogin : disable
snmp : enable
telnet : disable
ssh : disable
tftp : disable
ftp : disable
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy2
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
Sub-Context:
Current Context:
http : disable
rlogin : disable
telnet : disable
ssh : disable
snmpv3 : enable
tftp : disable
ftp : disable
------------------------------------------------------------------------------------------------------------
EXAMPLE 2): Upgrade with access level configured as ro, access-strict as true and snmp enabled
in 4.0.x
In 4.0.x:(before upgrading)
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy3
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readOnly
access-strict : true
Sub-Context:
Current Context:
http : disable
rlogin : disable
snmp : enable
telnet : disable
ssh : disable
tftp : disable
ftp : disable
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy3
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readOnly
access-strict : true
Sub-Context:
Current Context:
http : disable
rlogin : disable
telnet : disable
ssh : disable
snmpv3 : enable
tftp : disable
ftp : disable
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy4
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readWrite
access-strict : true
Sub-Context:
Current Context:
http : disable
rlogin : disable
snmp : enable
telnet : disable
ssh : disable
tftp : disable
ftp : disable
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy4
Sub-Context:
Current Context:
http : disable
rlogin : disable
telnet : disable
ssh : disable
snmpv3 : enable
tftp : disable
ftp : disable
------------------------------------------------------------------------------------------------------------
EXAMPLE 4): Upgrade with access level configured as rwa, access-strict as true and snmp
enabled in 4.0.x
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy5
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readWriteAll
Sub-Context:
Current Context:
http : disable
rlogin : disable
snmp : enable
telnet : disable
ssh : disable
tftp : disable
ftp : disable
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy5
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readWriteAll
access-strict : true
Sub-Context:
Current Context:
http : disable
rlogin : disable
telnet : disable
ssh : disable
snmpv3 : enable
tftp : disable
ftp : disable
Sub-Context: service
Current Context:
create :
delete : N/A
name : policy6
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readOnly
access-strict : false
Sub-Context:
Current Context:
http : disable
rlogin : disable
snmp : disable
telnet : disable
ssh : disable
tftp : enable
ftp : disable
Note: In 4.0.x users are not allowed to disable all the services available in the access policy. For example if five
out of the six services are already disabled in an access-policy, the user is not allowed to disable the last enabled
service.
create :
delete : N/A
name : policy6
policy enable : true
mode : allow
precedence : 10
network : 0.0.0.0/0.0.0.0
host : 0.0.0.0
username : none
accesslevel : readOnly
access-strict : false
Sub-Context:
Current Context:
http : disable
rlogin : disable
telnet : disable
ssh : disable
snmpv3 : disable
tftp : enable
ftp : disable
Copyright © 2007 Nortel Networks Limited - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing
Switch 8100/8300/8600 are trademarks of Nortel Networks Limited.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support
1. Release Summary
Release Date: 19-Dec-2006
Purpose: Software patch release to address customer found software issues.
3. Platforms Supported
Ethernet Routing Switch 8600 modules in 8006, 8010, and 8010 co chassis.
Please refer to the following documents for details on the Platforms Supported:
Release Notes for the Ethernet Routing Switch 8600 Series Switch Software Release 4.1.1.0 (Part No. 317177-
E)
6. Compatibility
This software release is managed with Java Device Manager (JDM) release 6.0.0.0
This software release supports the Web Switching Module (WSM) running version WebOS 10.0.34.0
Users will now be able to login to an ERS8600 using SSH with Public Key Authentication. (Q01483488-01)
An ERS8600 running OSPF and having an OSPF route with 32 bit mask that overlaps another OSPF route, will
no longer become unstable. (Q01491868-02)
If repeated Telnet or FTP sessions are opened against an 8600 In Band and/or out of band IP addresses with
quick closures, over the course of time this could lead to system instability. This situation is no longer present
with this code release. (Q01462275-01)
The ERS8600 will no longer have any traffic loss when MLT ports with an 'OCP Vendor' GBIC are bounced.
(Q01495927)
ERS8600 in a DUAL CPU non-HA mode (warm standby) configuration, with an 8683XZR card present will no
longer have the 8683XZR module become inactive when the master CPU is reset. (Q01487003)
When any fdb-filter is configured on an ERS8600, the MAC address record will now be shown within the
forwarding table with type as ‘mgmt’. Note that these filters still only apply to legacy/classic module ports, but can
be used in a mixed chassis configuration. (Q01497977)
8630GBR and 8683XZR cards will no longer become inactive when the master CPU is failed on a switch in HA-
CPU (hot standby) mode. (Q01493870).
An ERS8600 switch configured with an 8692 with the SuperMezz CPU option, will no longer become unstable
when SSH is disabled. (Q01497587-01)
An ERS8600 will no longer become unstable while R-login sessions are active. (Q01465058-03)
For an ERS8600 in HA mode and having installed an 8683XZR, the value of clock source parameter will no
longer get defaulted after having an HA failover. However there is a limitation to this problem which is listed in the
“Known Limitations” section of this doc. (Q01520484)
For an ERS8600 running OSPF and having OSPF routes based on type 3 summary LSA, when the destination
network of these routes is removed, the routes will get purged out of the routing table in much less time. This
problem was resolved in release 4.1.1.0. (Q01409753)
8. Outstanding Issues
If the allow-more-specific-route parameter is enabled and the configuration is saved, the value of the parameter is
lost after switch reboot. (Q01491654)
During an FPGA firmware upgrade, if the switch or an R-module is reset, the R-module may not get initialized.
During these upgrades, the user MUST wait for the returned CLI output, “FPGA UPDATE SUCCESS”, and then
wait an additional 30 seconds or so, before rebooting or resetting the switch to make the FPGA firmware change
active. (Q01501599-01)
In any RSMLT design running L3 IP Multicast, the traffic can stop flowing across the setup upon the re-boot and
recovery of a failed switch. (Q01505335)
RMON traps “Last System Change” & “Ethernet Octets stats” are not recognized by DM and Enterprise Switch
Manager (ESM). (Q01142068)
An ERS8600 using OSPF may have the following problems with opaque LSA:
1. When an opaque aware and a non-opaque aware router are mixed, opaque aware should become DR
(Designated Router) but in such a case, the ERS8600 will become DR instead.
2. A router should not respond to a LSA type 9 packet if it's 'O' bit is not set but the ERS8600 does.
3. The ERS8600 includes the LSA into its DD packet, which makes it an invalid packet. (Q01509489)
On a switch running cp-limit feature, if redirect-next-hop is configured using an ACL filter and global-action is set
to count or mirror-count the port having ingress traffic is shut down if the specified next-hop is unreachable. Do
not configure ACL redirect filters, with additional optional action of count or mirror-count (Q01493502,
Q01492644)
R-module ports currently do not properly handle tagged multicast traffic which must egress on the same physical
port that the traffic ingresses on. This affects any and all multicast based traffic or applications, of which Microsoft
NLB is one example. To workaround this issue, make sure that the client and server are connected to the
ERS8600 by different physical ports – different L2 switches in a SMLT environment, for example. Additionally, this
configuration on legacy module ports will provide a working environment. (Q01511596)
On an ERS8600 installed with 8630 GBR card, if an egress queue template is dynamically applied without a
switch reboot, the 8630GBR ports can get into a condition whereby individual port egress queues seize up and
the port is no longer able to transmit any frames. If changes to an egress queue are required, the user MUST re-
boot or reset the switch after the changes are made. In a future code release, a warning message will be
generated to the user for this activity. (Q01450460-01)
For an ERS8600 connected to an ES470 with SFFD being used on the connection, and if the connection is
multiple links to an 8630GBR module, failure or pulling out of one of the links, may cause the remaining links to
flap. Instead configure the connection between the ERS8600 and ES470 to use VLACP instead of SFFD, which
may require a code change on the ES470. (Q01464922).
For an ERS8600 configured with VRRP, the show config or save config commands will fail and CPU utilization will
increase to 100% on removing the VRRP IP address if the VRRP IP is also being used as a DHCP agent. VRRP
addresses should not be used as DHCP relay agents. Instead the physical IP interface address associated with
the VLAN should be used. (Q01473196-01)
Trying to accessing a switch with an installed WSM, running with version 10.0.34.0, from JDM with version 6.0.3,
the following error message is displayed:
ERROR: Cards in slots: slot# is running WebOS versions that incompatible with this version of Device Manager.
Please upgrade these cards to a later patch version." The message is erroneous, and can be ignored.
(Q01491448)
In any SMLT design for the ERS8600, ARP entries on clients connected to the SMLT client L2 switch may be
learned on the IST instead of the SMLT links after the MAC ages out. This can lead to intermittent user
connectivity issues. If seen, a flush of the ARP table (config ip arp flush), will correct the situation, at least
temporarily. Additionally setting the per VLAN FDB age out timer for all affect VLANs, to 21601 (1 second higher
than default system ARP age out timer), may assist as well. (Q01476117)
On an ERS8600 installed with ROHS compliant 8005AC power supplies DS1405012-E5, P/N 321411, the total
available power is not calculated correctly. Due to this the power supplies are not utilized fully. (Q01495801)
Upon issuing the command “show port info state” on an ERS8600, current time/date is displayed for a port in a
down state. The correct behavior should be to display the date/time of the last state change. (Q01474469-01)
An ERS8600 installed with R-modules, enabling the Tagged-Frames-Discard on any port of the R-module will
stop the IPV4/IPV6 bridging function of any protocol based VLANs associated with the port. Do not use this
configuration option with ports associated with any protocol based VLAN. (Q01427096)
On an ERS8600 with Dual SF/CPU modules installed, the switch fabric utilization LED behavior may not always
be shown correctly. (Q01497340)
On an ERS8600 with multiple WSM modules installed, and with a large configuration on the WSM modules, when
the switch is booted, some of the WSM cards might not be manageable except by the direct console connection,
but the module will pass traffic as normal. (Q01473364-01)
When an ERS8600 running VRRP is connected to a client through a layer 2 forwarding switch, under certain
conditions the 8600 may not reply for the ARPs sent for the VRRP IP address by the client. A ping of the end-
station client from the 8600, will resolve the situation. (Q01502287)
When setting dst-end to desired date and time, DST (Daylight Savings Time) does not take effect, as changes do
not take effect once the time is reached. (Q01501308)
When the switch CPU utilization reaches near constant 100% on an ERS8600, the SF/CPU module may hang
and will not fail-over for 1 to 2 minutes. Any sustained and constant high CPU utilization situations should always
be investigated, prior to the event causing any network disruption. (Q01374277)
Under certain situations, for an ERS8600 with HA-CPU mode (hot standby) enabled, and with having multiple
STGs, entries in the STG topology table may be lost after an HA-CPU failover. (Q01479548-02)
An ERS8600 with R-module installed, JDM does not display Egress Queue Set Queue 0. (Q01490598-01)
On a switch running PIM-SM, changing of activity-chk-interval parameter should not be allowed. Currently, the
ERS8600 allows it. Users should use just the default value of 210 for this parameter. (Q01464950-01;
Q01441360-01)
9. Known Limitations
Please refer to the “Known Limitations” section of the Ethernet Routing Switch 8600 Software Release 4.1.1.0
(Part Number 317177-E).
In certain cases, but only with 8692 and SuperMezz SF/CPU and with the Mezz option enabled, upon a power
cycle the chassis may come with slot 6 as the master, versus slot 5, even when master configuration option is set
to slot 5. To make slot 5 the master, a reset or re-boot on slot 6 must take place. (Q01522492)
When using the SuperMezz option, the mezz image (p80mxxxx.img) must match the previously load boot image
(p80bxxxx.img) or else the SuperMezz will not load/boot. (Q01522508)
1. When replacing or re-inserting any module with an ERS8600 chassis, the user MUST wait at least 30 seconds,
before putting in the replacement module, or for reseating the existing module. This requirement applies equally
to the SF/CPU, as it does to I/O modules. (Q01489847)
The most recommended L3 IPMC implementation with PIM-SM on and ERS8600 is to configure a candidate RP
with a multicast group address and mask that is as close to the multicast source as possible. The candidate BSR
should be configured on a router that is central to the entire candidate RP's. (Q01510496)
As well, a candidate RP can provide service to all potential multicast groups (224.0.0.0 – 239.255.255.255) if its
GroupAddress value is set to 224.0.0.0 with an associated GroupMask of 240.0.0.0 (see page 240 of the above
noted manual).
4. In the release notes for Ethernet Routing Switch 8600 Software Release 4.1.1. 0, the file sizes of
p80c4110.img (3DES image) and p80c4110.aes (AES image) are given wrongly (sizes are swapped). The correct
sizes in bytes are:
p80c4110.img: 55928
p80c4110.aes: 26112
5. When setting multiple ports of the 8683XZR module to WAN-mode, the frame Type and ClkMode have to be
set the same for all the ports configured for WAN-mode. Mixed settings for multiple WAN-mode enabled ports is
not allowed.
6. When upgrading FPGA firmware images, the user should (current Upgrade Guide does not call this out
exactly; next revision will):
a. Never download an image or multiple images to different modules at the same time. Only download
one image to one module at a time. FPGA firmware images can be downloaded with no impact on
system operation. The only action that affects system operation is the switch reboot which is required to
make all FPGA firmware updates take affect.
b. The user should always wait 30 seconds after the return to the telnet or console screen of the message
“FPGA UPDATE SUCCESS”, before issuing a system reboot for the FGPA upgrade(s) to take affect.
A more detailed log message will be added into a future code release to warn users of this required
action. (Q01509339)
Copyright © 2006 Nortel Networks - All Rights Reserved. Nortel, Nortel Networks, the Nortel logo, Globe mark, and Ethernet Routing Switch
8100/8300/8600 are trademarks of Nortel Networks.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in
this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full
responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel.
To access more technical documentation, search our knowledge base, or open a service request online, please visit Nortel Technical Support
on the web at: http://www.nortel.com/support