Flow Calculation
Flow Calculation
Flow Calculation
Tag of Cooler Fan Diamter (D), m Area (A), m^2 Average Velocity Volumetric Flow Rate Mass Flow Rate Volumetric Flow Kg Air/kg Clinker
(m/s) (m^3/s) (kg/s) Rate (m^3/hr)
1 500 FN11 0.459 0.16543725525 17.84 2.95140063366 3.8073068174 10625.04228118 13706.304542717 0.2897861335092
2 500 FN12 0.687 0.37061365725 14.97 5.548086449033 7.1570315193 19973.11121652 25765.3134693069 0.5447442485794
3 500 FN13 0.588 0.271495476 16.36 4.44166598736 5.7297491237 15989.9975545 20627.0968452998 0.4361092825341
4 500 FN14 0.643 0.32466082725 18.1 5.876360973225 7.5805056555 21154.89950361 27289.8203596569 0.5769762011006
5 500 FN15 0.632 0.313647696 10.45 3.2776184232 4.2281277659 11799.42632352 15221.2599573408 0.3218161435439
6 500 FN16 0.634 0.315635949 5.19 1.63815057531 2.1132142421 5897.342071116 7607.57127173964 0.1608434029291
Total 23.73328304179 30.615935124 85439.81895044 110217.366446061 2.3302754121963
Tag of
Average Velocity Volumetric Flow
S. No. Cooler Diamter (D), m Area (A), m^2
Fan (m/s) Rate (m^3/s)
Cooler Air
Density 1.23 kg/m^3
m^3/hr 88072.465266
TPH 50
KgPH 50000
m^3/kg-Clinker 1.76144930532
kg-Air/kg-Clinker 1.43207260595122