62 SERIES
Power relays 16 A
62
SERIES
Dielectric strength
between open contacts V AC 1500 3000
Ambient temperature range °C –40…+70 –40…+50
Environmental protection RT I RT I
Approvals (according to type)
3
62
SERIES
62 SERIES
Power relays 16 A
Dielectric strength
between open contacts V AC 1500 3000
Ambient temperature range °C –40…+70 –40…+50
Environmental protection RT I RT I
Approvals (according to type)
4
62 SERIES
Power relays 16 A
62
SERIES
Dielectric strength
between open contacts V AC 1500 3000
Ambient temperature range °C –40…+70 –40…+50
Environmental protection RT I RT I
5
62
SERIES
62 SERIES
Power relays 16 A
Dielectric strength
between open contacts V AC 3000 2000
Ambient temperature range °C –40…+70 –40…+70
Environmental protection RT I RT I
Approvals (according to type)
6
62 SERIES
Power relays 16 A
62
SERIES
Ordering information
Example: 62 series power relay + Faston 250 (6.3 x 0.8 mm), rear flange mount, 2 NO (DPST-NO), 12 V DC coil.
A B C D
6 2 . 8 2 . 9 . 0 1 2 . 0 3 0 0 A
T
E N
Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074) P A T
EUR
O
PEAN
The dual-purpose Finder test button can be used in two ways:
1 3 Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when
the test button is pushed, the contacts operate. When the test button is released the contacts return
to their former state.
X-2021, www.findernet.com
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition
to the above function), when the test button is pushed and rotated, the contacts are latched in
the operating state, and remain so until the test button is rotated back to its former position.
2 In both cases ensure that the test button actuation is swift and decisive.
7
62
SERIES
62 SERIES
Power relays 16 A
Technical data
Insulation according to EN 61810-1
A 2 CO - 3 CO 2 NO - 3 NO 1 NO* 2 NO*
Nominal voltage of supply system V AC 230/400 230/400 230/400 230/400
Rated insulation voltage V AC 400 400 400 400
Pollution degree 3 3 3 3
Insulation between coil and contact set
Type of insulation Reinforced Reinforced Reinforced Reinforced
Overvoltage category III III III III
Rated impulse voltage kV (1.2/50 µs) 6 6 6 6
Dielectric strength V AC 4000 4000 4000 4000
Insulation between adjacent contacts
Type of insulation Basic Basic — Basic
Overvoltage category III III — III
Rated impulse voltage kV (1.2/50 µs) 4 4 — 4
Dielectric strength V AC 2500 2500 — 2500
Insulation between open contacts
Micro-
Type of disconnection Full-disconnection Full-disconnection Full-disconnection**
disconnection
Overvoltage category — III III II
Rated impulse voltage kV (1.2/50 µs) — 4 4 2.5
Dielectric strength V AC/kV (1.2/50 µs) 1500/2 3000/4 3000/4 2000/2.5
Insulation between coil terminals
Rated impulse voltage (surge) differential mode
(according to EN 61000-4-5) kV (1.2/50 µs) 4
Other data
Bounce time: NO/NC ms 1/5 3/— 3/— 3/—
(changeover) (normally open) (normally open) (normally open)
Vibration resistance (10…150)Hz: NO/NC g 20/8
Shock resistance g 15
Power lost to the environment 2 pole (CO) 3 pole (CO) 2 pole (NO) 3 pole (NO) 1 pole (NO)* 2 pole (NO)*
without contact current W 1.3 1.3 3 3 1.3 1.3
with rated current W 3.3 4.3 5 6 3 3.3
Recommended distance between relays mounted on PCB mm ≥ 5 —
8
62 SERIES
Power relays 16 A
62
SERIES
Contact specification
F 62 - Electrical life (AC) v contact current
• When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time of the load will be increased.
50 50
DC breeaking current (A)
DC1 DC1
DC breaking current (A)
10 10
DC13
1 L/R = 40 ms 1 DC13
L/R = 40 ms
0.1 0.1
20 60 100 140 180 220 260 20 60 100 140 180 220 260
(V) (V)
Voltage DC (V) Voltage DC (V)
• When switching a resistive load (DC1), or a DC13 load with a diode in parallel to the load, having voltage and current values under the DC1 curve, an
electrical life of ≥ 100 · 103 can be expected. Note: the release time for the load will be increased.
• When switching a DC13 load without a diode in parallel to the load, the DC13 curve applies and an electrical life of ≥ 80 · 103 can be expected.
X-2021, www.findernet.com
9
62
SERIES
62 SERIES
Power relays 16 A
Coil specifications
DC version data AC version data
A Nominal
voltage
Coil
code
Operating range
Rated coil
Resistance consumption
Nominal
voltage
Coil
code
Operating range
Rated coil
Resistance consumption
UN Umin Umax R I at UN UN Umin Umax R I at UN (50Hz)
V V V Ω mA V V V Ω mA
6 9.006 4.8 6.6 28 214 6 8.006 4.8 6.6 4.6 367
12 9.012 9.6 13.2 110 109 12 8.012 9.6 13.2 19 183
24 9.024 19.2 26.4 445 54 24 8.024 19.2 26.4 74 90
48 9.048 38.4 52.8 1770 27 48 8.048 38.4 52.8 290 47
60 9.060 48 66 2760 21.7 60 8.060 48 66 450 37
110 9.110 88 121 9420 11.7 110 8.110 88 121 1600 20
125 9.125 100 138 12000 10.4 120 8.120 96 132 1940 18.6
220 9.220 176 242 37300 5.8 230 8.230 184 253 7250 10.5
240 8.240 192 264 8500 9.2
400 8.400 320 440 19800 6
10
62 SERIES
Power relays 16 A
62
SERIES
Coil specifications
R 62 - DC coil operating range v ambient temperature R 62 - AC coil operating range v ambient temperature
Changeover contacts Changeover contacts
A
R 62 - DC coil operating range v ambient temperature R 62 - AC coil operating range v ambient temperature
Normally open contacts Normally open contacts
11
62
SERIES
62 SERIES
Power relays 16 A
Outline drawings
Type 62.22 Type 62.23 Type 62.2x Type 62.2x-0300
62.22-0300 62.23-0300
A
Type 62.31-4800
Type 62.32-4800
X-2021, www.findernet.com
12
62 SERIES
Power relays 16 A
62
SERIES
Accessories
Mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 (M4) 062.10
A
062.10
062.60
062.05
Top 35 mm rail (EN 60715) mount for types 62.3x and 62.8x.xxxx.xxx9 062.07
062.07
Rear 35 mm rail (EN 60715) mount for types 62.3x and 62.8x.xxxx.xxx9 062.08
062.08
Sheet of marker tags (CEMBRE Thermal transfer printers) for 62 series relays,
plastic, 48 tags, 6 x 12 mm 060.48
060.48
13
62
SERIES
92 SERIES
Sockets and accessories for 62 series relays
86.30
99.02 coil indication and EMC suppression modules for 92.03 socket
Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00
LED(6...24)V DC/AC 99.02.0.024.59
LED (28...60)V DC/AC 99.02.0.060.59
LED (110...240)V DC/AC 99.02.0.230.59
LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99
99.02
LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99
Approvals
(according to type): LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99
LED + Varistor (6...24)V DC/AC 99.02.0.024.98
LED + Varistor (28...60)V DC/AC 99.02.0.060.98
LED + Varistor (110...240)V DC/AC 99.02.0.230.98
X-2021, www.findernet.com
14
92 SERIES
Sockets and accessories for 62 series relays
62
SERIES
Packaging codes
How to code and identify retaining clip and packaging options for sockets.
Example:
9 2 . 0 3 S M A
A Standard packaging