CALIBRATION
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations1, 5:
Up to 25 mm 0.000 45 mm
Up to 1 in 180 µin Precision micrometer
Up to 25 mm 0.0015 mm Indicator
Up to 1 in 59 µin
AC Voltage3 – Generate
AC Voltage3 – Measure
AC Current3 – Generate
AC Current3 – Measure
AC Current3 – Clamp-On
Meters
Insulation Resistance3 –
Piston Operated
Volumetric Apparatus –
Piston Operated
Volumetric Apparatus –
Piston Operated
Volumetric Apparatus –
(cont)
VIII. Mechanical
Pressure Gages,
Calibrators3 –
Pressure Transmiters3 –
Pressure Safety Valve (-9 to -1) psi 0.4 % of reading Vacuum & pressure
(PSV´s) & Pressure (-62.1 to -1) kPa indicator
Switch3
(1 to 10 000) psi 0.1 % of reading
(1 to 68.95) MPa
(2 to 1000) kg 83 g
(2 to 2000) kg 0.17 kg
Mass –
Torque Tools & (1 to 10) Nꞏm (0.0005ꞏreading + 0.0038) Nꞏm AWS TT-QC-100I-
Torque Wrenches 1/4 torque transducer
and display
Torque Transducers³ Up to 1,13 Nꞏm (8.92 × 10-5X + 4.97 × 10-5) Nꞏm Comparison with
Torque Indicator³ torque arm and
(1.13 to 11.3) Nꞏm (5.27 × 10-4X – 1.65 × 10-4) Nꞏm OIML class F1, F2 &
M1 weights
(11.3 to 113) Nꞏm (6.62 × 10-4X – 1.21× 10-2) Nꞏm
X = reading value
(113 to 1016) Nꞏm (1.76 × 10-3X – 2.31 × 10-1) Nꞏm
Force – Tension & (44 to 1000) N 0.12 % of reading Precision load cells
Compression Testing
Machines3 (>1 to 5) kN 0.14 % of reading
Light Meters³ –
Light Visible (20 to 3000) lux (8.6 × 10-5X + 1.0) % of Reference standard
(Luxmeter) reading lamp
X = reading value
Spectrophotometers3 –
Absorbance:
λ: (235 to 350) nm (0.09 to 0.28) A 0.0037 A Potassium
(0.19 to 0.57) A 0.0045 A Dichromate
(0.29 to 0.87) A 0.0049 A quartz cells
(0.39 to 1.15) A 0.0057 A
(0.48 to 1.45) A 0.0067 A
Spectrophotometers3 –
(cont)
Absorbance:
Neutral
λ: (440 to 635) nm (0.52 to 0.56) A 0.0027 A density glass
(0.66 to 0.77) A 0.0027 A filters
(0.95 to 1.11) A 0.0027 A
Transmittance:
Wavelength:
Holmium glass
SBW: (0.1, 0.25, 0.5, (241 to 638) nm 0.12 nm filter
1, 1.5, 2, 3, 4, 5) nm
Didymium glass
SBW: (0.1, 0.25, 0.5, (440 to 880) nm 0.12 nm filter
1, 1.5, 2, 3, 4, 5) nm
X. Thermodynamics
Temperature3 – Measure
X = reading value
_______________________________________________
1
This laboratory offers commercial calibration service and field calibration service.
2
Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets the
R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
_______________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4150.01
Valid to December 31, 2022
For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.